GE Army Jaisalmer
GE Army Jaisalmer - 345001
SPECIAL REPAIRS TO BLDG NO. P-101, P-109, P-110, ROLLING SHUTTER IN BLDG NO. P-1757 AND P-1758 AND ADDITIONAL AND ALTERNATION TO CERTAIN BLDGS AT MIL STN JAISALMER
2022_MES_562445_1
8243/22-23/E8
Open Tender
Civil Works
Item Rate
180 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹86,000
Yes
28 Feb 2023
11 Nov 2022
21 Dec 2022
11 Nov 2022
19 Dec 2022
28 Nov 2022
Amount
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Removing excavated soft/ disintegrated rock to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by the Engineer-in-Charge.
Taking down chowkats or frames (without taking off shutters from the frames) area not exceeding 1.5 Sqm each complete all as specified & directed by Engineer-in-charge.
Taking down chowkats or frames (without taking off shutters from the frames) area exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified & directed by Engineer-in-charge.
S&F pressed steel door frame for doors made out of 1.2 mm thick sheet with one or more rebates incl necessary fixing lugs, hinges ,lock strike plate, etc size 125x60 mm complete all as specified & directed by Engineer-in-Charge.
S&F solid PVC door frame of size 50x47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S. Square tube suppling and fixing in opening as per specification and drawing complete all as specified & directed by Engineer-in-charge.
S & F for Plain, framed, panelled shutters 35 mm thick in second class hard wood (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified & directed by Engineer-in-Charge.
S&F Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified & directed by Engineer-in-Charge.
S&F Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.). hinges type B-21 100mm long (2 No.) suitable handle (1 No.) complete all as specified & directed by Engineer-in-Charge.
S&F for 35 mm thick Glazed and skeleton shutters in second class hardwood, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified & directed by Engineer-in-Charge.
S&F 30mm thick of Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, uppling & fixing in the frame at site as per specification & drawing etc complete all as specified & directed by Engineer-in-Charge.
S&F mild steel butt hinges, medium weight cold rolled 100mm size complete all as specified & directed by Engineer-in-Charge.
S&F 150mm long aluminium anodized, barrel tower bolt of extruded section complete all as specified & directed by Engineer-in-Charge.
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy all as specified & directed by Engineer-in-charge.
S&F aluminium (Die cast) door closer hydraulically regulated designation No. 3, universal type, suitable for door shutter of 851 mm to 1000mm in width and of weight between 61 to 80 Kg complete all as specified & directed by Engineer-in-charge.
S&F Plain sheet glass of 3 mm thick ordinary quality and glazing with oil putty and clips in squares not exceeding 0.50 Sqm in each pane complete all as directed by Engr-in-charge.
S&F for Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.00mm and fixed with tinned tacks, or galvanised wire staples all as directed by Engr-in-charge.
M&L for figured glass 4mm thick, pin head type and glazing with oil putty in squares n exc 0.5 sqm in each pane complete all as specified & directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified & directed by Engineer-in-Charge.
Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified & directed by Engineer-in-Charge.
M&L for 25mm thick PCC (1:2:4) type B-0 (using 12.5mm graded stone aggregate) as in subbase of floors & finishing the surface even & fair without using extra cement complete all as specified & directed by Engineer-in-Charge.
M&L for roughening existing concrete surface, apply 1.3 Kg/Sqm cement slurry, 15mm thick cement screed bed or bedding layer of cement mortar (1:4) for laying and including floor finishes non skid ceramic tiles exterior grade 300x300x10mm thick heavy duty, set and jointed in neat slurry and pointed in coloured cement to match the colour of tiles complete all as specified and directed by Engineer-in-charge. Note :- Rate quoted by the tenderer shall be deemed to inclusive of roughening of flooring, cement slurry, screed bed and tiling complete
M&L light shade, vitrified tiles, 10mm thick (minimum), (square/ rectangular polished, area of each tiles not exceeding 0.36 Sqm in flooring set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed or bedding in CM (1:4) complete all as specified & directed by Engineer-in-charge.
M&L light shade, vitrified tiles, 10mm thick (minimum), (square/ rectangular polished, area of each tiles exceeding 0.36 Sqm but not exceeding 0.42 Sqm in flooring set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed or bedding in CM (1:4) complete all as specified & directed by Engineer-in-charge.
M&L for Glazed ceramic coloured tiles 350x250x7mm/450x350x7mm thick in vertical surfaces etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 10mm thick backing coat in CM (1:4) complete all as specified and directed by the Engineer in Charge.
M&L non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed by the Engineer in Charge.
M&L for Granite 20mm thick table rubbed and polished in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixure of pigment to match with marble shade of Makrana white complete all as specified and directed by the Engineer in Charge.
Taking down cement plaster of any description on stone or brick walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by the Engineer in Charge.
M&L for rendering 15mm thick on brickwork or concrete on wall surfaces in cement mortar 1:6, finished even and smooth without using extra cement complete all as specified and directed by the Engineer in Charge.
M&L for rendering 15mm thick on brickwork or concrete on wall surfaces in cement mortar 1:4, mixed with WPC finished fair and even complete all as specified and directed by Engr-in-Charge. Note :- Supply only WPC will be measured & paid seperately).
M&L for rendering 5 mm thick in CM (1:3) on fair faces of concrete surfaces as in ceiling finished even and smooth without using extra cement all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surfaces of walls and apply two coats of distempering oil emulsion over a coat of primer complete all as specified & directed by Engineer-in-charge.
M&L for preparing new plastered or unplastered surfaces and apply three coats of white wash on ceiling complete all as specified & directed by Engineer-in-charge.
M&L for preparation of new plastered or unplastered surfaces of walls and apply two coats of cement base paint over a coat of putty for uniform smooth surface complete all as specified & directed by Engineer-in-charge.
M&L for complete removal of the existing treatment on walls by scraping and washing down with water including making good the surfaces and applying one coat of alkali resistant primer and treating with two coats of oil emulsion distemper complete all as specified & directed by Engineer-in-charge.
M&L for preparation of old decorated plastered surfaces of walls and applying one coat of cement base paint complete all as specified & directed by Engineer-in-charge.
M&L for preparing old plastered/ concrete surfaces ceiling by brooming down or steel wire brushing, scrapping down smoke soof, moulds, moss and efflorescent salts and trading oil and greasing spots and applying one coats of white wash all as specified & directed by Engineer-in-charge.
M&L for prepartion of old painted wood or wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified & directed by Engineer-in-charge.
M&L for preparation of old painted steel surfaces of any description over 10 cm width girth and applying one coat of synthetic enamel paint complete all as specified & directed by Engineer-in-charge.
M&L for 100mm thick plain cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in hard standing finished even & smooth without using extra cement complete all as specified & directed by Engineer-in-Charge.
M&L 75 mm thick PCC (1:3:6) type C1 (using 20mm graded stone aggregate) in plinth protection and path laid in alternative bays finished even and smooth without using extra cement and complete all as specified & directed by Engineer-in-Charge.
S&F in repair, cast iron, nahani trap with CP grating including jointing to waste pipe in cement mortar, diameter of out let 75mm bore fixed in cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) complete all as specified & directed by Engineer-in-Charge.
S&F in repair, cast iron, nahani trap with CP grating including jointing to waste pipe in cement mortar, diameter of out let 100mm bore fixed in cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) complete all as specified & directed by Engineer-in-Charge.
S&F cast iron, nahani trap with CP grating including jointing to waste pipe in cement mortar, diameter of out let 100mm bore fixed in cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) complete all as specified & directed by Engineer-in-Charge.
S&F cast iron, nahani trap with CP grating including jointing to waste pipe in cement mortar, diameter of out let 75mm bore fixed in cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) complete all as specified & directed by Engineer-in-Charge.
M&L in repair, 125mm/110mm dia PVC (SWR) gully trap, setting & jointing with solvent cement complete all as specified & directed by Engineer-in-charge.
S&F in repairs of curtain rails, mild steel, chromium plated with fixing brackets, stops, rollers etc and complete all as specified & directed by Engineer-in-Charge.
S&F in repairs 75 mm long aluminium anodised hasp and staple safety type complete all as specified & directed by Engineer-in-Charge.
S&F in repairs tubular towel rail brass chromium plated 20mm dia D type 60cm long complete all as specified & directed by Engineer-in-Charge.
M&L for 12mm thick prelaminated particle board exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work and including dismantling existing boarding of any description complete all as specified & directed by Engineer-in-Charge.
M&L for 2nd class hardwood Plain fillets. square, rectangular or triangular in section, clean sawn, secured with nails or brads area not exc 3Sqcm complete all as specified & directed by Engineer-in-Charge.
S& F in repair floor door stopper of aluminium alloy body with steel spring 150 mm fixed to door complete all as specified & directed by Engineer-in-Charge.
S&F in repair continiuos (piano) hinges of flap width 30mm , mild steel, bright finish or electogalvanised complete all as specified & directed by Engineer-in-Charge.
M&L for preparing new or previously untreated wood and wood based surfaces of any description otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint (Ordinary tint) over a coat of pink primer complete all as specified & directed by Engineer-in-charge.
M&L for preparation of new or previously untreated steel surface of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red- oxide, zinc chrome primer complete all as specified & directed by Engineer-in-Charge.
Taking down GI tubing 15 mm dia with all fitting fixed to wall and ceiling,concelled in walls/ floor etc complete all as specified & directed by Engineer-in-Charge.
Taking down GI tubing 20 mm dia with all fitting fixed to wall concelled in walls/ floor and ceiling etc complete all as specified & directed by Engineer-in-Charge.
S&F 15mm bore dia steel water tubing (ISI marked) medium grade galvanised with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F 20mm bore dia steel water tubing (ISI marked) medium grade galvanised with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F in repairs 15mm dia bib taps, cast copper alloy chromium plated with crown or capstan head, screwed down, high pressure screwed for iron pipe complete all as specified & directed by Engineer-in-Charge.
S&F in repairs 15mm dia pillar taps cast copper alloy with capstan head chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified & directed by Engineer-in-Charge.
S&F in repairs 15mm dia stop valves fancy type cast copper alloy chromium plated screwed down high pressure with crown or capstan head screwed both ends for iron pipe complete all as specified & directed by Engineer-in-Charge.
S&F in repairs brass chromium plated shower rose with swivel joints 125mm dia with 18mm dia chromium plated pipe complete all as directed by Engr-in-charge.
S&F in repairs gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe, 20mm bore complete all as directed by Engr-in-Charge.
S&F in repair kitchen steel sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as directed by Engineer-in-charge.
S&F rotational moulded polyethylene water storage tanks 1000 litres capacity triple layered (White) cylindrical vertical with closed top hoisted and 20mm ball valves high pressure with polythene float and flynut complete fixed in position including dismantling water tank and removing to store of any description complete all as directed by Engr-in-charge.
S&F in repairs 10 ltrs capacity PVC low level flushing cistern with inlet, ball valve, float, handle including fitting and fixtures complete all as all as directed by Engr-in-Charge.
S&F in repair vitreous china wash down water closet pedestal pattern including connecting to flush tank complete all as specified & directed by Engineer-in-Charge.
S&F in repair for pressure jet for western type water closet with PVC connection 600 to 900 mm long including brass head screw and suitable washer complete all as specified & directed by Engineer-in-Charge.
S&F in repair 600 mm long PVC connection pipe of 15mm bore with PTMT nut at both ends complete all as specified & directed by Engineer-in-Charge.
S&F in repair plastic water closet seat cover, coloured closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified & directed by Engineer-in-Charge. (Make :- Cera Model Cat Part No. 2308 or equivalent from the list of makes.)
S&F in repairs vitreous china wash hand basin, white, flat back, size 550 X 400 mm excluding taps, chain and plug and porcelain stopper but including CP waste coupling & brackets and fixed complete all as specified & directed by Engineer-in-Charge.
S&F Plate racks made of stainless steel 1mm thick with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and overall size 750mmx 600mm complete all as specified & directed by Engineer-in-Charge.
S&F in repair 15 mm Brass CP mixer for mixing hot & coldwater screwed down for iron pipe and fixed complete all as specified & directed by Engineer-in-Charge.
S&F Pre painted Galvalume aluminium zinc coating GI based corrugated steel sheet/ semi corrugated 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws and including dismantling existing roof sheeting complete all as specified & directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified & directed by Engineer-in-Charge.
S & F Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe-410- W(Gde- E-250) quality-B complete all as specified & directed by Engineer-in-Charge.
S&F sand Cast iron soil, waste and vent pipes 100mm dia in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified & directed by Engineer-in-Charge.
S&F sand Cast iron soil, waste and vent pipes 75 mm dia in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified & directed by Engineer-in-Charge.
S&F sand Cast iron soil, waste and vent pipes 100mm dia in any length with or without ears, with cement joints, Fixed to wall complete all as specified & directed by Engineer-in-Charge.
S&F sand Cast iron soil, waste and vent pipes 75 mm dia in any length with or without ears, with cement joints, Fixed to wall complete all as specified & directed by Engineer-in-Charge.
S&F CI Bends 100 mm dia (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified & directed by Engineer-in-Charge.
S&F cast iron 100 mm dia P or S trap complete all as specified & directed by Engineer-in-Charge.
S& F Cast iron 75 mm cowl complete all as specified & directed by Engineer-in-Charge.
Dismantling of 100 mm dia cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required of any size complete all as specified & directed by Engineer-in-Charge.
S&F soap dish brass chrome plated fancy type complete all as specified & directed by Engineer-in-Charge.
S&F Shelf of PTMT shelf fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) complete all as specified & directed by Engineer-in-Charge.
S & F grating Square type 150mm of PTMT (Minimum weight 100gms) complete all as specified & directed by Engineer-in-Charge.
M&L for Renforcement cement concrete nominal mix (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) for chajja, roof projection, facies and similar works and including demolition of existing reinforcement concrete complete all as specified & directed by Engineer-in-Charge.
Formwork to chajjas, roof projection and similar work including edges with rough finished surfaces of concrete including height upto 6 mtr complete all as specified & directed by Engineer-in-Charge.
S&F for mild steel TMT bars 6mm to 8mm dia cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed by Engineer-in-Charge.
M&L for Flush cutting of RCC chajjas, fins with reinforcement up to 150 mm depth by norms of Rcc mechanical cutting machine, complete all as specified & directed by Engineer-in-Charge.
M&L for providing APP based polymeric memrane weighing 3Kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric ( wt not less than 150 gm/sqm) laid over primed surface by forced application including bituminous primer confirming of IS 3384 applied @ 0.30 ltr/sqm and the APP membrane will be laid over CM 1:3 with water proofing compound as per manufacturer's instructions also the APP will be laid by torch application method over lap shall be 75mm on length of 100 mm width side complete all as specified & directed by Engineer-in-Charge. Four course roof treatment consist of as under - (i) Applying 10mm thick 1:3 CM with water proofing treatment (ii) Applying one coat of bituminous primer coating to IS 3384 @0.3 ltr/sqm (iii) Laying of APP membrane as specified per sqm thickness (iv) applying one coat of bitumen grade 85/25 @1.25 Kg/Sqm
S&F Steel rolling shutter (thickness of lath 1.25mm thick) without ball bearing as specified including top hood cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated complete gear operated type with chain wheel and hand chain complete all as specified & directed by Engineer-in-charge.
S&F in repair aluminum power coated partition wall of aluminum section 100mm x 44mm x 2mm thick frame rectangular section and panel 12mm thick prelaminated board in bottom panel and 5.5mm thick sheet glass in top panel with rubber lining and aluminum beading around length including necessary fixing arrangement for bottom and top member of aluminum frame in floor/PCC/Brick work as per site requirement with rawl plug etc, including chromium plated steel screws 60cm centre to centre complete all as specified & directed by Engineer-in-charge. (Note :- Rate quoted by the Contactor shall deemed to inclusive of 12mm thick prelaminated board and 5.5mm thick sheet glass).
Supply fabricating and fixing in repair of aluminium door powder coated of extrusion aluminium section including frame work complete, consisting of frame vertical and horizontal members, of size 104mmx44.45mmx 1.8mm thick. Vertical style of door shutter of size 85mmx44.45mmx 1.8mm thick. Top, middle and bottom rial of size 85mmx44.45x1.8mm thick and partially 5 mm thick plain/tinted sheet glass of partially prelaminated particle board 9 to 10mm thick with aluminium bedding and rubber gasket/beading including frosted film as desired fixing of hydraulic floor spring one in single leaf or two nos in double leaf door. One mortice lock for aluminium door (each) and two aluminium tower bolts for each door. Fixed with rawl plug including rectification of floor/wall to match the existing surfaces all as specified and as directed by Engineer-in-Charge at site. Note :- Rate quoted shall deemed to inclusive of partially 5 mm thick sheet glass with sun control film and partially 12mm thick prelaminated particle board.
S&F in repair Soap dish, chromium plated as per sample approved by Engineer-in-Charge.
S & F 75mm dia PVC pipe with all fitting and fixed to wall, ceiling or laid in floors etc complete all as specified & directed by Engineer-in-charge.
S & F Table top Wash hand basin white, including cutting for and pinning ends of brackets or erecting stand.((Model : Jaquar Cat No: JDS-WHT- 25909 or equivalent in Appx 'C'list of makes.
Taking down carefully surface aluminium or copper point wiring with PVC casing-caping (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc and making good disturbed surfaces complete all as specified & directed by Engineer-in-charge.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including MCBs any type and capacity making good the disturbed surfaces to match with the existing finishes complete all as specified & directed by Engineer-in-charge.
Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified & directed by Engineer-in-charge.
Taking down old unsv building security light fittings complete all as specified & directed by Engineer-in-charge.
Taking down old unsv /rusted GI braket suitable for security light fittings complete all as specified & directed by Engineer-in-charge.
Taking down of old unsv tubelight fitting /surface panel light / flood light of any description light fitting any type any watt complete all as specified & directed by Engineer-in-charge.
Taking out carefully copper/GI earthing complete including GI pipe with copper orGI strip and removing materials and making good disturbed surface complete all as specified & directed by Engineer-in-charge.
Taking down Old unsv single pole and neutral enclosure with a two pin and earth plug and socket with 20 Amps MCB SP complete all as specified & directed by Engineer-in-charge.
M&L Point wiring used approved colour coding as per IS (Red, Black and Green) for single phase circuits), with multi-stranded copper conductor 1.5 sqmm nominal cross -sectional area, single core, PVC insulated and unsheated FRLS cable 1100 volts grade, ISI 694 marked with valid CML No. in and including medium grade, PVC concealed conduit, ISI marked of dia not less than 20 mm and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No. (IS-9537 - 1983 for condits and IS : 3419 - 1976 for conduit accessories) with terminated to new pressed flush metal boxes readily available cover with outer plates inner plates et, suitable for mounting modular type switches, socket fan regulator etc PVC insulated multistanded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :- Note : Modular switch and socket shall be measured and paid separately.
a) One light point controlled by one switch
b) One ceiling/exhaust fan point controlled by one switch
(c) One socket outlet 6 amp controlled by one switch on the same board with other switches.
(d) One 2/3 pin socket outlet 5Amps on independent board.
All as per item No 110.00 above but pint wiring with 4.00 sqmm single core multi stranded copper conductor PVC insulated and unsheathed (FRLS) cable 1100 volts grade and 4.00 Sqmm PVC insulated and unsheated (FRLS) cable 1100 volts grade with multi stranded copper conductor as earth wire for 15/16 Amps multi porpose socket combination point on independent board. Note : Modular switch and socket shall be measured and paid separately.
S&F modular switch one way 6A, 1 module complete all as specified & directed by Engineer-in-charge.
S&F modular socket 6A-2/3 pin combined 2 module complete all as specified & directed by Engineer-in-charge.
S&F modular switch socket combined 6A/16A, 6 pin, 3 module complete all as specified & directed by Engineer-in-charge.
S&F step type modular fan regulator 120W -2 module ISI Marked with valid CML No complete all as specified & directed by Engineer-in-charge.
S&F Ceiling rose, three terminals PVC/polycorbonate, isolated body complete all as specified & directed by Engineer-in-charge.
M& L Point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.2 mm with 3 mm thick phenolic laminated white sheet cover for mounting of Piano Type switches, sockets, fan regulators complete for the following :-
(a) One light point controlled by one switch.
(b) One Ceiling /Exaust fan point controlled by one switch.
(c) One socket outlet 6 amp controlled by one switch on the same board with other switches.
(d) One socket outlet 6 amp controlled by one switch on indepdendent board.
All as above item No 117.00 but M& L Point wiring with 1100 volts grade PVC insulated FR multistranded copper conductor cable 4.0 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4.0 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1.2 mm covered with 3 mm thick phenolic laminated white sheet cover for one 16 amp socket outlet controlled by one switch on independent board complete all as specified & directed by Engineer-in-charge.
S&F switch piano flush button single pole one way 5/6 amp complete all as specified & directed by Engineer-in-charge.
S&F switch piano flush button single pole one way 16 amp complete all as specified & directed by Engineer-in-charge.
S&F socket outlet 2 in 1, 3 pin 6 & 16 amp flush type complete all as specified & directed by Engineer-in-charge.
S&F socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type complete all as specified & directed by Engineer-in-charge.
S&F hum free electronic step fan regulator 120 - 280 volts of 100 watt capacity (socket type) including connecting up complete all as specified & directed by Engineer-in-charge.
S&F vertical DBs TPN 4 way 415 V double door powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 250 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required, suitable for TP/FP MCCB as incomer including MCCB 160A , and with SP/TP MCCB's as incoming MCCB FP 160A , 25 KA complete all as specified & directed by Engineer-in-charge.
S & F for MCB DB TPN 4 way double door IP 43 complete prewired including Bus Bar etc suitable for operation on 415 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified & directed by Engineer-in-charge.
S & F for sheet metal double door IP protection 43 enclosure MCB DB TPN 4 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system complete all as specified & directed by Engineer-in-charge.
S & F for MCB DB SPN 8 way double door IP 43 complete prewired including Bus Bar etc suitable for operation on 240 volt 50 Hz AC including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good the distrubed surface to match with existing specification complete all as specified & directed by Engineer-in-charge.
S & F for MCB DB SPN 12 way double door IP 43 complete prewired including Bus Bar etc suitable for operation on 240 volt 50 Hz AC including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good the distrubed surface to match with existing specification complete all as specified & directed by Engineer-in-charge.
Supply and fixing 415V 10 KA 'C" curve MCB's TPN 63 to 100 Amps four pole and current carrying capacity in the DB with necessary connections and comissioning complete all as specified & directed by Engineer-in-charge.
Supply and fixing MCB's single pole and neutral 32 Amps, 240 Volts,10 KA rapturing capacity, 'C' curve complete all as specified & directed by Engineer-in-charge.
Supply and fixing MCB's single pole 10 Amps to 32 Amps, 240 Volts,10 KA rapturing capacity, 'C' curve complete all as specified & directed by Engineer-in-charge.
M & L for submain wiring with approved colour code/as per IS (Red,black & green for single phase) concealed conduit circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.00 Sqmm (FRLS) in conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 6.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified and directed by Engr-In-Charge. (Note :- Two runsof 6.00 Sqmm cable & one run of 6.00 Sqmm cable as earth wire and one run of PVC conduit shall be measured and paid as one unit length)
M & L for submain wiring with approved colour code/as per IS (Red,black & green for three phase) conduit circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 10.00 Sqmm (FRLS) in conduit pipe size 25 mm or above including two run of PVC insulated multistranded copper conductor nominal cross sectinal area of 10.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified and directed by Engr-In-Charge. (Note :- Four runs of 10.00 Sqmm cable & one run of 10.00 Sqmm cable shall be paid as one unit length).
S&F sheet metal enclosure MCB SP 20 Amp as Gyser/AC Box complete all as specified & directed by Engineer-in-charge.
Supply and fixing of building security light fitting LED 35 Watt IP 66 IK 07 pressure dia cast aluminium housing with high efficient LED and PC cover having TOP opening sepreate drive compartment etc and connecting complete all as specified & directed by Engineer-in-charge.
S&F bracket of GI pipe light grade of 40mm bore dia, 1.2 meter in length, MS clamps made of FI 40 mm x 6mm incl nuts, bolts & washers including two coats of synthetic enamel paint over a coat of zink chrome primer complete all as specified & directed by Engineer-in-charge.
Supply and fixing of LED box type Integrated Batten, 40 watt having Aluminum Extruded housing in white powder coated finish with high translucent PC Cover, Elegant Design, IP 20 Protection. Size of fitting shall 1200 mm x 40 mmx 63 mm luminous output of the fitting shall not less then 4000 lm, CCT 5700 – 6500K, Surge Protector 4 KV, PF>= 0.95 , Separate detachable type Electronic constant current drivers for easy replacement and maintenance, THD < 10%, Necessary mounting arrangements. The Manufacturer of the fixture shall have in house NABL Accredited Lab and must produce certificate of the same along with LM-79 / LM80 / Test Report. Make PHILIPS CAT PART NO. BN100C LED40S-6500 PSU L120 GR S4 or equivalent in Appx 'C' list of makes.
Supply and fixing of recessed/ceiling mounted down lighter with CRCA housing with high bright LED, idealy suited for low ceiling areas Brilliance 36watt LED, size 2ft x 2ft The product features color tuning from 3000 K to 6500 K, necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with white color flexible pipe complete complete all as specified & directed by Engineer-in-charge.
S&F LED tube light fitting 10 watt tube LED Neutral white in colour, 600 mm in length wall mounted LED batten, extruded aluminium heat shink provided for efficient heat dissipation & integrated electronic driver, optic diffused type ENDURA LINER NEO including all electric connection with and including white flexible cord 1.50 Sqmm 3 core as required complete all as specified & directed by Engineer-in-charge.
S&F LED post top lantern/gate Light 40 watt light fitting made of cast aluminium spigot housing with decarative opal acrylic diffuser with IP 65 protection with all accessories including taking down existing unserviceable complete all as specified and directed. Make-Havells Cat part No CORALPT35WLED830PSYMTOPC or equavalent in Appx ''C" list of makes.
Taking down ceiling fan/exhaust fan of any sweep, dismanting blade and including preparation, filling cavity applying one coat of synthetic enamel paint by spraying with machine, re-assembling the fan body to fan and re-fixing in its original position or any other position as directed complete all as specified & directed by Engineer-in-charge. Note :- Rate quoted by the contractor shall deemed to inclusive of replacing of quarter pin, nut bolt with check nut, rubber real etc.
Taking down storage geyser of any capacity after disconnecting electrical connection from existing socket, removing the bolts and nuts from wall and disconnected inlet and outlet water connection including preparation of surface and apply synthetic enamel paint by spraying with machine including filling cavity with filler one coat and including refixing the geyser it's original location after repair/replacing the unsv items like heating element, thermostat, PVC connection pipe of hot & cold type changing of outer body with its inner tank if found unservicable, making Geyer serviceable in all respect complete all as specified and directed by Engineer -in-Charge. (Note :- Rate Quated by Contractor shall be inclusive for replacing all unsv item like Sefty valve, Heating element, Thermostat, PVC Connection pipe of hot & cold type, Changing of outer body with its inner tank ete).
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in pipe or fixed to DBs or any other indicated situation for loop earthing with GI strip of 25X3 mm size complete all as specified and directed Engg-in-Charge.
M&L for sand cushioning to under ground cable using tibba sand and gently punning to cushioning to cable complete all as directed by Engineer-in-Charge. (Note :- Punned thickness of sand cushioning shall only measured for the purpose of payment).
Supply & laying 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and not exc 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 40 mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors in trench on pole for protection of cable etc complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 80 mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors in trench on pole for protection of cable etc complete all as specified & directed by Engineer-in-charge.
M& road cutting in trenches for laying cable protection pipe including making good the surface with top 200mm thick shall filled with PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) complete all as specified & directed by Engineer-in-charge.
M&L for LT XLPE insulated, armoured heavy duty, electric cable, with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm 4 Core and including taking down existing unserviceable cable complete all as specified & directed by Engineer-in-charge.
M&L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 50 Sqmm 3½ core and including taking down old existing cable complete all as specified & directed by Engineer-in-charge.
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground levl connected to galvanized iron strip 25x4 mm as earthing lead up to 7.5 mtr by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection and testing complete all as specified & directed by Engineer-in-charge.
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate & salt up to ground levl connected to galvanized iron strip 32 x6 mm as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection all necessury earth work ,excavation ,earth chamber with PCC 1:3:6 type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20 mm dia GI watering pipe with funnel and wire mesh etc and testing complete all as specified & directed by Engineer-in-charge.
NOTE FOR ITEM No. 151 & 152.00 [i]. Excavation & earth work in any type of soil including removing of surplus material upto 100M [ii]. PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways. [iii]. Main earthing strip from earth electrode to test point upto 7.5 mtr. [iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd. [v]. GI protection pipe of size 40 mm bore light grade 7.5m.
Supply, installing testing and commissioning out door type CPRI approved LT cubical panel suitable for 3 phase 4 wire 415 Volts, 50 HZ and factory made in an approved factory made of 3.15mm thick CRCA sheet & MS angle section 50x50x6mm frame with front & back openable double door system lockable / openable by keys having busbar capacity 400 Amp compring of following :- (For FPB-3 &4)
Supply,fix, commissioning and testing air cooled split unit air conditioner electric driven, single phase of capacity of 2.0TR BEE 3 star rating copper pipe condensor, remote control, including mounting of inner and outer unit on wall and making hole in wall for refrigerant copper pipes, flexible cable mounting bracket for out door unit complete all as specified & directed by Engineer-in-charge.
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indooor type & designed for input variation between 170 V to 250 V with output volatge stabilized at 230 V with accuracy of + - 2.5 % and of capacity 4 KVA complete all as specified & directed by Engineer-in-charge.
S K TRADER
Bhawani Constructions
M/s Shri Inder Construction Company
Leelashah Enterprises
M/S MAYA CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .