| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹8.2 LQualified Make: FLUKE
Model: Fluke 437 Series II 400Hz Power Quality and Energy Analyzer 212 AGARAWAL CITY SQURE MANGALAM PALACE ROHINI SECTOR 3 NORTH WEST DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | Make: FLUKE
Model: Fluke 437 Series II 400Hz Power Quality and Energy Analyzer | L1 | Qualified | |
| 2 | Not yet disclosed by govt. Qualified Make: FLUKE
Model: FLUKE-437-II, 400Hz Power Quality and Energy Analyzer | Make: FLUKE
Model: FLUKE-437-II, 400Hz Power Quality and Energy Analyzer | - | Qualified | |
| 3 | Not yet disclosed by govt. Disqualified Make: HIOKI
Model: HIOKI & PW3198 | Make: HIOKI
Model: HIOKI & PW3198 | - | Disqualified | |
| 4 | Not yet disclosed by govt. Disqualified Make: Metrel
Model: Metrel Class A Power Quality Analyser MI 2892 Power Master | Make: Metrel
Model: Metrel Class A Power Quality Analyser MI 2892 Power Master | - | Disqualified | |
| 5 | Not yet disclosed by govt. Disqualified Make: FLUKE
Model: FLUKE 9062 | Make: FLUKE
Model: FLUKE 9062 | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
27 Jul 2018, 12:00 pmClosed
power quality analyzers Power Quality Analyzers ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values PERFORMANCE FEATURES Type of Power analyzer Three phase Single phase
Three phase Number of Current Channels (Nos.) 4 1
2
3
4 Number of Voltage Channels 4 1
4 Measurable voltage range 1000 600
1000 Measurable voltage accuracy 0.1 0.04
0.1
0.2
0.5
1 Measurable voltage resolution 0.1 1
0.1 Measurable current range (with clamp) 5000 5000
2000 Measurable current accuracy (%) ±0.5 ±0.04
±0.1
±0.2
±0.5
±1 Measurable current resolution 0.1 0.1
1
10 Maximum power that can be measured (KW) 400 4
40
400 Power Accuracy (%) ±1.5 ±1.5
±2
±2.5 Power resolution 1 1
5
50
500 1/7 MEASUREMENT FEATURES Facility to Measure Frequency Available - Frequency range that can be measured 40-65 Hz - Facility to Measure Inter harmonics Available - Order(n) to which Facility to Measure Harmonics available upto 50th - Facility to Measure Power Factor Available - Accuracy in measurement of Power Factor (%) 0.1 - Facility to Measure Distortion Factor Not-Available - Accuracy in measurement of Distortion Factor (%) NA - Facility to Measure Ripple Factor Not-Available - Accuracy in measurement of Ripple Factor (%) NA - Facility to Measure crest factor Not-Available - Measurable crest factor range 1 TO 10 - Measurable crest factor accuracy (%) 5 - Measurable crest factor resolution 0.01 - Facility to Measure sag(dips) and swell(surge) Available - Pattern of measurement of sag(dips) and swell(surge) Waveform - Facility to Measure Total Harmonic distortion Available - Accuracy in measurement of Total Harmonics distortion 2 - Facility to Measure voltage and current unbalance Available - 2/7 Facility to Measure inrush current Available - Facility to Measure flicker Available - DISPLAY Display type LCD - Display Mode Waveform
Meter Reading
Vector
digital reading - GENERAL FEATURES Facility to Measure RMS Voltage Available - Facility to Measure RMS Current Available - Facility to Measure Active
Reactive and Apparent Power Available - Facility to Measure Active
Reactive and Apparent Energy Available - GENERIC Data transfer software provided for analysis on PC Yes - Provision for external SD Card yes - Interface USB - Internal Memory (GB) 4 - Weight of the analyser 1.5 - other features The Fluke 437 Series II 400Hz Power Quality and Energy Analyzer is designed specifically for the defense and avionics industries. Capable of measuring up to 400 Hz
the 437 II is a must-have for those working in submarines
aircraft
it has a facility of 5 channels for Input voltage. - POWER SOURCE/BATTERY Power Supply 230 V AC +/- 10%
50Hz - If battery operated
chemistry of the rechargeable battery lithium ion - Voltage of rechargeable Battery 10.8 - capacity of rechargeable battery 2500 - 3/7 (milli AH) Suitable charger adaptor provided yes - Battery backup (hours) 8 - OPERATING CONDITION Minimum Operating Temperature 0 - Maximum Operating Temperature 40 - Operating Humidity (%) 70 - ACCESSORIES Details of All connecting Cables and accessories to be supplied along with the Analyser BC430 Power Adapter International plug adapter set BP290 (Single capacity Li-ion battery) 28 Wh (7 hours or more) TLS430 Test lead and Alligator clip set WC100 color coding clips and regional decals i430flex- TF
24 inch (61 cm) length
4 clamps 8 GB SD card PowerLog on CD (includes operator manuals in PDF format) USB cable A-Bmini - SAFETY Compliance to IEC 61000-4-30 Yes - Category of safety rating Category IV 600 V of IEC 61010 - TEST REPORT DETAILS & TESTS The equipment supplied with calibration certificate yes - conformity to Dry Heat for 16 hours at a specified maximum temp in accordance with IS:9000/part-3/sec tion-5/1977 latest Yes - conformity to Cold Test for 4 hours at a specified minimum temp in accordance with IS:9000/part-2/sec tion-4/1977 latest Yes - conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temperature of 40 degree C & 95% RH yes - Availability of Test Yes - 4/7 Reports from Central Govt/NABL approved/ILAC accredited lab to prove conformity to the specification Test Report Number and date 39553208 & 26/july/2017 - Name and address of the Lab Fluke Corporation USA - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 ARUN KUMAR 144102
AIR FORCE STATION ADAMPUR STATION LOGISTIC SECTION 1 15
351369
GEM/2018/B/49780
power quality analyzers
15 days
Punjab; Jalandhar
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| power quality analyzers Power Quality Analyzers ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values PERFORMANCE FEATURES Type of Power analyzer Three phase Single phase | - | - | - |
| Three phase Number of Current Channels (Nos.) 4 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 Number of Voltage Channels 4 1 | - | - | - |
| 4 Measurable voltage range 1000 600 | - | - | - |
| 1000 Measurable voltage accuracy 0.1 0.04 | - | - | - |
| 0.1 | - | - | - |
| 0.2 | - | - | - |
| 0.5 | - | - | - |
| 1 Measurable voltage resolution 0.1 1 | - | - | - |
| 0.1 Measurable current range (with clamp) 5000 5000 | - | - | - |
| 2000 Measurable current accuracy (%) ±0.5 ±0.04 | - | - | - |
| ±0.1 | - | - | - |
| ±0.2 | - | - | - |
| ±0.5 | - | - | - |
| ±1 Measurable current resolution 0.1 0.1 | - | - | - |
| 1 | - | - | - |
| 10 Maximum power that can be measured (KW) 400 4 | - | - | - |
| 40 | - | - | - |
| 400 Power Accuracy (%) ±1.5 ±1.5 | - | - | - |
| ±2 | - | - | - |
| ±2.5 Power resolution 1 1 | - | - | - |
| 5 | - | - | - |
| 50 | - | - | - |
| 500 1/7 MEASUREMENT FEATURES Facility to Measure Frequency Available - Frequency range that can be measured 40-65 Hz - Facility to Measure Inter harmonics Available - Order(n) to which Facility to Measure Harmonics available upto 50th - Facility to Measure Power Factor Available - Accuracy in measurement of Power Factor (%) 0.1 - Facility to Measure Distortion Factor Not-Available - Accuracy in measurement of Distortion Factor (%) NA - Facility to Measure Ripple Factor Not-Available - Accuracy in measurement of Ripple Factor (%) NA - Facility to Measure crest factor Not-Available - Measurable crest factor range 1 TO 10 - Measurable crest factor accuracy (%) 5 - Measurable crest factor resolution 0.01 - Facility to Measure sag(dips) and swell(surge) Available - Pattern of measurement of sag(dips) and swell(surge) Waveform - Facility to Measure Total Harmonic distortion Available - Accuracy in measurement of Total Harmonics distortion 2 - Facility to Measure voltage and current unbalance Available - 2/7 Facility to Measure inrush current Available - Facility to Measure flicker Available - DISPLAY Display type LCD - Display Mode Waveform | - | - | - |
| Meter Reading | - | - | - |
| Vector | - | - | - |
| digital reading - GENERAL FEATURES Facility to Measure RMS Voltage Available - Facility to Measure RMS Current Available - Facility to Measure Active | - | - | - |
| Reactive and Apparent Power Available - Facility to Measure Active | - | - | - |
| Reactive and Apparent Energy Available - GENERIC Data transfer software provided for analysis on PC Yes - Provision for external SD Card yes - Interface USB - Internal Memory (GB) 4 - Weight of the analyser 1.5 - other features The Fluke 437 Series II 400Hz Power Quality and Energy Analyzer is designed specifically for the defense and avionics industries. Capable of measuring up to 400 Hz | - | - | - |
| the 437 II is a must-have for those working in submarines | - | - | - |
| aircraft | - | - | - |
| it has a facility of 5 channels for Input voltage. - POWER SOURCE/BATTERY Power Supply 230 V AC +/- 10% | - | - | - |
| 50Hz - If battery operated | - | - | - |
| chemistry of the rechargeable battery lithium ion - Voltage of rechargeable Battery 10.8 - capacity of rechargeable battery 2500 - 3/7 (milli AH) Suitable charger adaptor provided yes - Battery backup (hours) 8 - OPERATING CONDITION Minimum Operating Temperature 0 - Maximum Operating Temperature 40 - Operating Humidity (%) 70 - ACCESSORIES Details of All connecting Cables and accessories to be supplied along with the Analyser BC430 Power Adapter International plug adapter set BP290 (Single capacity Li-ion battery) 28 Wh (7 hours or more) TLS430 Test lead and Alligator clip set WC100 color coding clips and regional decals i430flex- TF | - | - | - |
| 24 inch (61 cm) length | - | - | - |
| 4 clamps 8 GB SD card PowerLog on CD (includes operator manuals in PDF format) USB cable A-Bmini - SAFETY Compliance to IEC 61000-4-30 Yes - Category of safety rating Category IV 600 V of IEC 61010 - TEST REPORT DETAILS & TESTS The equipment supplied with calibration certificate yes - conformity to Dry Heat for 16 hours at a specified maximum temp in accordance with IS:9000/part-3/sec tion-5/1977 latest Yes - conformity to Cold Test for 4 hours at a specified minimum temp in accordance with IS:9000/part-2/sec tion-4/1977 latest Yes - conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temperature of 40 degree C & 95% RH yes - Availability of Test Yes - 4/7 Reports from Central Govt/NABL approved/ILAC accredited lab to prove conformity to the specification Test Report Number and date 39553208 & 26/july/2017 - Name and address of the Lab Fluke Corporation USA - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 ARUN KUMAR 144102 | - | - | - |
| AIR FORCE STATION ADAMPUR STATION LOGISTIC SECTION 1 15 | - | - | - |
Exempted
14 Aug 2018
18 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_351369.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .