RequiredExperience with Government Non Invasive Cardiac Support Pump With Defibrillator ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Product Specifications
RequiredCertifications and Warranty Cardiopulmonary resuscitation (CPR) Device
Requiredable to generate chest compression & provide consistent compression with on interruptions Yes * Easy to use in both Hospital and Emergency set up mainly during Yes * 1/5 transportation with facility to provide chest compression to patient while carrying to staircase and even on 45 degree elevation Yes * Battery operated and with extremely simple user interface Yes * Ability to achieve uniform load distribution by squeezing entire chest Yes * Ability to do the high quality compression in CPR using: Chest compression band * Should have small LCD backlit screen to show compression modes Yes * Display: Small LCD backlit screen to show compression modes * Ability to automatically size the patient by calculating size
Requiredshape and compliance of every patient: Yes * Capability to provide compression just by pressing buttons: 30:2 (30 compression and 2 ventilation pause ) compressions
RequiredContinu ous compression 30:2 (30 compression and 2 ventilation pause ) compressions
RequiredContinuous compression Accessories Set (each unit of the equipment shall be supplied with 3 load distribution bands
Required1 battery charger unit and 3 batteries: Yes * Equipment unit should be according to AHA guidelines and can have capability to be upgradeable to any amendments in 2020 AHA guidelines onsite through IR Port or other facility available in unit Yes * Equipment has Defibrillator or providing synchronised shock while the device is working(imparting Yes * 2/5 CPR to patient): Should be rugged and have easy to read three mode displays to be rugged and should have easy to read three mode displays to be readable in any environment Yes * Should have facility for ECG Monitoring
Requireddefibrillation
Requiredexternal pacing (transcutaneous) & recorder: Yes * Type of technology used in Defibrillator: Biphasic * Energy selection range of Defibrillator 1 to 200 joules * Charging time of defibrillator unit: < 7 seconds to attain maximum energy * Defibrillator should have ability to measure chest compression rate and depth in real time and both visual and optional audible feedback is provided Yes * Ability that all CPR data can be recorded and reviewed by using software specially designed for doing this (if needed) Yes * Ability to filter out CPR artifacts and allowing person to see organized rhythms without interrupting chest compression Yes * Availability of voice and visual prompts and have GPS clock: Yes * Provision of Clock in defibrillator: GPS clock to provide complete time. * Unit have option to upgrade to Et CO2 Yes Yes Unit have option to upgrade to Sp CO2 Yes Yes Unit have option to Yes Yes 3/5 upgrade to NIBP: Unit have option to upgrade to 12 leads: Yes Yes Certifications: US FDA * Warranty period: 5 years 5 years * Bold specifications are the golden parameters.