Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹27.6 LAccepted-AOC A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | 1 | Accepted-AOC Accepted being L1 Contractor | |
| 2 | 2₹31.0 L+₹1.8 L (6.27%)Rejected-AOC | 2 | Rejected-AOC Rejected being not L1 | |
| 3 | 3₹33.8 L+₹4.6 L (15.8%)Rejected-AOC | 3 | Rejected-AOC Rejected being not L1 | |
| 4 | 4₹34.6 L+₹5.4 L (18.6%)Rejected-AOC | 4 | Rejected-AOC Rejected being not L1 | |
| 5 | 5₹36.2 L+₹7.0 L (23.9%)Rejected-AOC | 5 | Rejected-AOC Rejected being not L1 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
23 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY ELEC SUPPLY
GE UTILITY ELEC SUPPLY DELHI CANTT
Repair and maintenance of 11 .415 KV electrical breakdown incl fault detection localization and rectification in Underground network at Dhaula Kuan Part 1 Dhaula Kuan Part2 Nodel Pump House 2 Shooting Range 8711 Cermonial Battery Nicholson Ran
2024_MES_663308_1
GE ELECT/D-28/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE UTILITY ELEC SUPPLY
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE UTILITY ELEC SUPPLY
₹84,000
Yes
20 Sept 2024
2 Jul 2024
25 Jul 2024
2 Jul 2024
23 Jul 2024
16 Jul 2024
Amount
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft/loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level complete all as specified and directed by Engr- in- Charge.
Returning filling in,. Including spreading, levelling,. Watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by Engr- in- Charge.
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed by Engr- in- Charge.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified and directed by Engr- in- Charge. Note : Measurement shall be taken after punning down.
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as specified and directed by Engr- in- Charge.
All as per srl item No 5 here-in-before but using old bricks complete all as specified and directed by Engr- in- Charge.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mm complete all as specified and directed by Engr- in- Charge.
All as per srl item No 7 here-in-before but using old un-reinforced precast concrete cable cover complete all as specified and directed by Engr- in- Charge.
Supply, laying, jointing, testing and commissioning in replacment LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-1554 marked, laid in trenches complete all as specified and directed by Engr- in- Charge. Cables of the following sizes:- Note Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately.
16 Sqmm 4 core
25 Sqmm 4 core
35 Sq mm 3.5 core.
50 Sq mm 3.5 core.
70 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
300 Sqmm 3.5 core
Supply, laying, jointing, testing and commissioning in replacment LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-1554 marked, laid in trenches complete all as specified and directed by Engr- in- Charge. Cables of the following sizes:- Note Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately.
95 sqmm 3 core.
120 sqmm 3 core.
150 sqmm 3 core.
185 sqmm 3 core
240 sqmm 3 core
300 sqmm 3 core
400 Sqmm 3 core
Testing the cables with high voltage DC testing machine and locating the fault in the cables by fault locating machine to pin point exact position of fault, disconnecting faulty 11 KV HT cables of different sizes from both ends, removal of Fault, Re-connections and testing of cables after removal of fault complete all as specified and directed by Engr- in- Charge. Note: (a) 11 KV HT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable cable cover/bricks will be laid in trenches for cable protection. If extra PCC cover/bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
All as per item Ser No 11 above but 1100 Volt LT cables complete all as specified and directed by Engr- in- Charge.
Taking out faulty underground 1100 Volt LT cable of different sizes by excavation and removing bricks of any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks as required complete all as specified and directed by Engr- in- Charge. Note: (a) 1100 Volt LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable bricks will be laid in trenches for cable protection. If extra bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
All as per item Ser No 13 above but 11000 Volt HT cables complete all as specified and directed by Engr- in- Charge.
Material and labour disconnecting faulty /burnt end or portion of cable by removing the cable from loop including necessary excavation & earth work , suitable size of thimble LT tap , relaying and reconnecting the cable by removing faulty/burnt portion of cable and preparing fresh terminals for 25 Sqmm 3.5/4 core to 240 Sqmm 3.5 core of LT cable to LT Panel/pole/main switch complete all as specified and directed by Engr- in- Charge.
Supply, fixing and testing LT straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade complete all as specified and directed by Engr- in- Charge, for the following sizes :-
16-25 Sqmm x 3.5 core/ 4 core
35-50 Sqmm x 3.5 core
70-95 Sqmm x 3.5 core
120-150 Sqmm x 3.5 core
185 -300 Sqmm x 3.5 core
Supply, fixing and testing jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor complete all as specified and directed by Engr- in- Charge, cable of following size :-
95 Sqmm,3 core.
120 Sqmm to 185 Sqmm, 3 core.
240 Sqmm to 300 Sqmm 3 core
Supply, fixing and testing Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor complete all as specified and directed by Engr- in- Charge, cable of following size :-
95 Sqmm 3 core.
120 Sqmm to 185 Sqmm, 3 core.
240 Sqmm to 300 Sqmm, 3 core.
Supply, fixing and testing Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor complete all as specified and directed by Engr- in- Charge, cable of following size :-
95 Sqmm 3 core.
120 Sqmm to 185 Sqmm, 3 core.
240 Sqmm to 300 Sqmm 3 core
Boring of hole under road/pavement/hard standing or any other situation by mannual means and including GI pipe 100 mm bore (medium grade) and making good both ends complete all as specified and directed by Engr- in- Charge.
Supply and lay GI pipe light grade as in cable protection laid on trench/floor, fixed on pole/wall or laid in nallah/culvert etc complete all as specified and directed by Engr- in- Charge, of following sizes all as specified of size:-
100 mm dia
80 mm dia
50 mm dia
40 mm dia
Supply and laying as replacement in sub station fixing 3.3 KV to 11 KV insulating mat of size 5mtr x 1 mtr x 2.5 mm thick specification as per IS-15652 2006 complete all as specified and directed by Engr- in- Charge.
Earthing in replacement complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.10 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized iron strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as directed. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
S&F in replacement of UNSV /Burnt MCCBs of capacity 630 Amps, FP, 50 KA, 415 Volts 50 Hz, AC, with thermal and magnetic release fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable MCCB from panels etc complete all as specified and directed by Engr- in- Charge.
Description all as per sel item No 24 above but rating of MCCB 400 Amp, 35 KA complete all as specified and directed by Engr- in- Charge.
S&F in replacement MCCB 4 pole, 100 Amp, 16 kA, 415 Volt AC, 50 Hz with MCCB Sheet metal encloser mounted on wall with fastner and suitable size of nut and volts after taking down old existing UNSC MCCB/SFU complete all as specified and directed by Engr- in- Charge.
M&L for spreading of stone aggregate of nominal size not more than 25mm under 4/6 pole HT structure /surrounding area of outdoor RMU manually without damaging any equipments, cable or parts , spreading & leveling of finished gravel uniformly in layers n. ecc. 15 cm thick watered and rammed to true surface complete all as specified and directed by Engr- in- Charge.
Supplying & fixing of LED street light Fitting 60 watt LED, IP-66 protection, single peice pressure die cast aluminium housing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and control gear compartment with high voltage surge protection device up to 4.5 KV, prewired conductor to fitting with 3 core 1.5 sqmm pvc insulated cable along with GI pipe bracket for street light fitting complete with 2.2 mtr long 50mm dia GI pipe medium grade and including necessary mild steel clamp , nuts,bolts and wahsers and painting on steel surfaces with two coats of aluminium paint complete as as specified and directed.
Supplying & fixing of LED street light Fitting 45 watt LED, IP-66 protection, single peice pressure die cast aluminium housing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and control gear compartment with high voltage surge protection device up to 4.5 KV, prewired conductor to fitting with 3 core 1.5 sqmm pvc insulated cable along with GI pipe bracket for street light fitting complete with 2.2 mtr long 50mm dia GI pipe medium grade and including necessary mild steel clamp , nuts,bolts and wahsers and painting on steel surfaces with two coats of aluminium paint complete as as specified and directed.
Supply, drawing, connecting & testing of 3 core, 1.5 Sqmm PVC insulated and PVC rounded sheathed, copper conductor (flexible) industrial cable 1100 Volts grade conforming to IS-694 in steel tubular pole from KIOSK box to light fittings including PVC conduit of size 20mm bore with clamping(Wherever required) and providing suitable copper lugs complete all as specified and directed by Engr- in- Charge. Note : Steel tubular pole shall be measured and paid separetely.
S&F in replacement of LED Flood light fittings of capacity 120 Watt with IP-66 Protection complete all as specified and directed by Engr-in-Charge.
S&F in replacement of LED Flood light fittings of capacity 200 Watt with IP66 Protection complete all as specified and directed by Engr-in-Charge.
Taking down unservicable RCC/ steel tubular poles of any type and supply & installing steel tubular swaged poles type 410 SP-31 (9 mtr long) of approx wt.147 kg conforming to IS 2713 (Part-II), complete with cast iron/MS plate 6mm thick and of size 300x300mm, final taper, pole cap, bolts, nuts, washers & screw etc including excavation, earth work, PCC foundation,PCC coping,GI pipe for cable protection etc. and GI bracket for fitting mounting, complete all as per manufacturer's instructions and as specified and as directed by E-in-charge. NOTE:- The unit rate in this item is deemed to be included the cost of exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole and GI bracket made of GI pipe medium grade 40 mm bore, 1.5 mtr long for fixing of street light fitings along with clamps. The steel pole shall be painted by bituminious paint total length inside and up to planting depth outside and remaining portion of pole painted with two coat of aluminium paint over a coat of red oxide complete all as specified and directed by Engr-in-Charge.
M&L for re-painting of LT Steel tubular poles of any sizes with apply of 2 coats of aluminium paint including rubbing with wire brush/emery paper & writing pole Nos in appropriate size of letters including making yellow and black strips upto height of 1.5 mtr above from ground level complete all as specified and directed by Engr-in-Charge.
Supply and fixing mild steel chequered plates Fe410-10-W(Gde-E-250) qualityon cable pit sizes as required on site 6mm to 10 mm thick including taking out old unsv RCC duct cover complete all as specified and directed by Engr-in-Charge.
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge
Rajindera Enterprises (BID ID -3072461)
DS CONSTRUCTION (BID ID -3071634)
KISHORE ENTERPRISES (BID ID -3071202)
Microsys Controls India (BID ID -3068552)
Commercial Traders (BID ID -3072401)
MV Engineers And Contractors (BID ID -3067778)
M/s JAIMAA ASSOCIATES (BID ID -3072064)
mayur enterprises (BID ID -3070245)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .