Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹44.7 L+₹83,896.80 (1.91%)Rejected-AOC NO 133 RASHTRAPATHI ROAD SECUNDERABAD 500 003 | SECUNDERABAD | HYDERABAD | TELANGANA | 500003 | L2 | Rejected-AOC L2 | |
| 3 | L3₹44.9 L+₹1.0 L (2.37%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹45.2 L+₹1.3 L (2.86%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹45.2 L+₹1.3 L (3.01%)Rejected-AOC 704 SILVER DEAL DAFFODIL WING 1 B T KAWADE ROAD PUNE 411 001 | PUNE | PUNE | MAHARASHTRA | 411001 | L5 | Rejected-AOC L5 |
Tender Value
₹48.9 L
EMD Value
₹97,720
Closing Date
9 Dec 2022, 6:00 pmClosed
GE (AF) Hakimpet
Secunderabad
SPECIAL REPAIRS TO BUS BAR CHAMBAR, LT PANEL BOARDS, AND CONNECTED FIXTURES AT BEGUMPET AND CERTAIN REVENUE AND MINOR WORKS AT AFS BEGUMPET UNDER GE (AF) HAKIMPET
2022_MES_561481_1
8454/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BEGUMPET
As per NIT
6 documents required · 6 mandatory
₹500
GE (AF) HAKIMPET
₹97,720
Yes
21 Dec 2022
4 Nov 2022
12 Dec 2022
4 Nov 2022
9 Dec 2022
25 Nov 2022
Amount
Supply, installation, testing & commissioning of Feeder Pillar Box cubical type, CPRI approved, factory made, totally enclosed dust and vermin proof, IP 54, free standing, fully compartmentalized in design suitable for 3 phase, 4 wire, 415 volts, 50 Hz system, with 500 Amps capacity, aluminium bus bar, outdoor type, 3 mm thick CRCA sheet with double doors at front & rear side inclusive of necessary locking arrangement, suitable glands, opening for vent and cable entry, with angle Iron of size 40mm thick including internal wiring with PVC insulated copper cable, grouted in floor complete with the following accessories, duly pre-treated and powder coated finish including taking down old unserviceable panel:-
(Location -CWE OFFICE SUB STN ) (a) MCCB, 4 pole 315A, 36 KA -01 No (Thermal magnetic release) - Incomer (b) MCCB, 3 pole 125A, 16KA -01 Nos (Thermal magnetic release). (c) MCCB, 3 pole 100A, 16 KA -02 Nos (Thermal magnetic release). (d) MCCB 3 Pole 63 A, 16 KA - 05 Nos (Thermal magnetic release) (Two Spare ) (e) Digital display VAF Panel meter - 01 No. (f) LED Indicator RYB - 01 set of 3
Supply, installation, testing & commissioning of Feeder Pillar Box CPRI approved, cubical type, factory made, totally enclosed dust and vermin proof, IP 54, free standing, fully compartmentalized in design suitable for 3 phase, 4 wire, 415 volts, 50 Hz system, with 300 Amps capacity, aluminium bus bar, outdoor type, 3mm thick CRCA sheet with double doors at front & rear side inclusive of necessary locking arrangement, suitable glands, opening for vent and cable entry, with angle Iron of size 40mm thick including internal wiring with PVC insulated copper cable, grouted in floor complete with the following accessories, duly pre-treated and powder coated finish including taking down old unserviceable panel:-
(Location :Range area hump house Key Qtr, NTS,12 ASC, Welessely, FCM Officr Mess ) (a) MCCB, 4 pole 200 A, 36 KA -01 No (Thermal magnetic release)- Incomer (b) MCCB, 3 pole 100A, 16 KA -01 Nos (Thermal magnetic release). (c) MCCB, 3 pole 63A, 16 KA -04 No (Thermal magnetic release). (d) Spare compartment for MCCB -01 No. (e) Digital display VAF Panel meter - 01 No. (f) LED Indicator RYB - 01 set of 3 (g) Din rail suitable to fix 8 MCBs
Repairs and Maint of LT Feeder pillar Boxes , replacing the unserviceable door hinges, locks , cutting the burnt portion of cable / lugs and crimping with new lugs of suitable size and connecting . Painting the Feeder Pillar Box with approved colour and all as shown and directed.
Excavation in trenches not exceeding 1.5 m in wide and not exceeding 1.5m in depth for laying of cables / stay assembly / pipe lines and getting out in the any type of soil complete all as specified and as directed.
Ditto all as per item above, but depth exc 1.5 m and n.exc 3 m complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and as directed.
Supply and spreading clean, fine, dry river sand in trenches for cushioning of under ground cable / inside transformer yard complete all as specified and directed by Engineer-in-Charge. Note: Only punned thickness shall be measured for payment purpose.
Supply and lay common burnt clay building bricks sub class 'B' of designation 75 laid in trenches as protection to cables complete all as specified and as directed.
M & L for Road cutting / hard standing for taking up or laying of LT UG cable upto a depth of 15 cm, after laying of cable, well ramming to the excavated soil and repair the exvcavated portion of road as existing or by providing suitable mixture of PCC all as specified and as directed.
M&L for new galvanized steel tubing, light grade, with all fittings for protection of cable complete all as specified and as directed of the following sizes :-
a) 100mm bore
b) 80mm bore
c) 50mm bore
d) 40 mm bore
Taking down UNSV LT UG cables of following sizes Note :- Earth work Excavation measured and paid seperately.
(a) 10Sqmm, 2 Core
(b) 25Sqmm, 3.5/4 Core
(c) 50 Sqmm, 3.5 Core
(d) 70 to 120 Sqmm, 3.5 Core
(e) 150 to 185 Sqmm, 3.5 core
Supply &Laying LT UG Cables , XLPE insulated heavy duty electric cables with aluminium conductor, 1100 volts grade, of following cross-sectional area complete all as specified and as directed.
(a) 10Sqmm, 2 Core
(b) 25Sqmm, 3.5 Core
(c) 50 Sqmm, 3.5 Core
(d) 70 Sqmm, 3.5 core
(e) 95 Sqmm, 3.5 Core
(f) 120 Sqmm, 3.5 core
(g) 150 Sqmm, 3.5 core
(h) 185 Sqmm, 3.5 core
M&L for earthing complete with galvanized steel earth plate electrode of size 600mm x 600mm x 6mm thick, buried directly in ground vertically to a depth not less than 2.25 Mtr below ground with top edge of the earth plate not less than 1.5 mtr below normal ground level, Earth plate shall be connected with double bolts, nuts, check nuts & washers, to & including 32x6 mm galvanized iron strip as earth lead, extended upto 7.5 m 'or' upto test terminal point, drawn through 40mm dia light grade GI pipe for protection of galvanized iron strip in the ground, further connecting with suitable size of earth strip to LT Panel, Transformer, DBs etc., including excavation, earth work, magnesium sulphate-50 Kg and charcoal in alternate layers on all sides sorrounding the earth plate, bentonite-25 Kg clay mixed with water and loomy soil sorrounding the plate on all sides, all as specified with
PCC chamber, RCC cover slab, watering pipe 20mm dia bore med. grade, wire net, funnel etc. & testing on completion all as specified in plate No.3 of SSR Pt-I, including breaking and removing the old unsv earth materials complete all as specified and as directed.incl taking out unserviceble Earthing from Sub stns Note :- Excavation earth work and GI strip upto 7.5 mtr incl in the rate quoted
M & L for Earth Continuity conductor or Main Earth lead fixed to wall or butten or recess or chasses or burried in ground or drawn in conduit /pipe or fixed to poles or any any other indicated satution for loop earthing etc of size 32x6 galvased iron strip.
S&F new MCCBs, 3 pole, 415 volts, to suit in the panel as existing type and model, including modification to the panel as required, of capacity from 25 to 100 Amps, breaking capacity 25 KA including taking down old MCCBs, complete all as specified and as directed. Make: Siemens / L&T / Schneider / GE Controls/Havells.
S&F new MCCBs, 3 pole, 415 volts, to suit in the panel as existing type and model, including modification to the panel as required, of capacity 125 Amps, breaking capacity 25 KA including taking down old MCCBs complete all as specified and as directed. Make: Siemens / L&T / Schneider / GE Controls/Havells.
S&F new thermal adjustable MCCBs, 3 pole, 415 volts, as existing type and model, including modification to the panel as required, of capacity 160 Amps, breaking capacity 36 KA including taking down old MCCBs complete all as specified and as directed. Make: Siemens / L&T / Schneider / GE Controls/Havells.
S&F new thermal adjustable MCCBs, 3 pole, 415 volts, to suit in the panel as existing type and model, including modification to the panel as required, of capacity 200 Amps with breaking capacity 36 KA including taking down old MCCBs complete all as specified and as directed. Make: Siemens / L&T / Schneider / GE Controls/Havells.
S&F new thermal adjustable MCCBs, 3 pole, 415 volts, to suit in the panel as existing type and model, including modification to the panel as required, of capacity 250 Amps, breaking capacity 36 KA including taking down old MCCBs complete all as specified and as directed. Make: Siemens/L&T/Schneider/GE Controls/Havells..
S&F new MCCBs, 3 pole, 415 volts, of existing type and model suitable for panel mounting of capacity 320 Amps, breaking capacity 36 KA including taking down old MCCBs complete all as specified and as directed. Make: Siemens / L&T / Schneider / GE Controls/Havells..
S&F new MCCBs, 3 pole, 415 volts, of existing type and model suitable for panel mounting of capacity 400 Amps, breaking capacity 36 KA including taking down old MCCBs complete all as specified and as directed. Make: Siemens / L&T / Schneider / GE Controls/Havells..
Cutting and removing the damaged portion of the cable, Supply, prepare and connect cable jointing kit for 1.1 KV grade cable for heat shrink type straight through joint complete with jointing material and accessories suitable for XLPE, armoured aluminium conductor for following sizes:-
(a) 10/16 Sqmm, 2 Core
(b) 25 to 50 Sqmm, 3.5/4 Core
(c) 70 to 95 Sqmm, 3.5 Core
(d) 120 to 240 Sqmm, 3.5 Core
Supply and laying LT UG XLPE insulated of size16 Sq mm 4 core 1100 volt grade heavy duty cable multi stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel strip wire or tape and connecting up to the electrical system with suitable size of aluminium lugs complete all as specified and directed.
Supply, Installation, Testing and Commissioning of Integral LED Focus light luminarie 240 Watt LED streetlight made up of pressure die cast aluminium housing with integrated polycarbonate lens, high powerCeramic LEDs with IP66 protection. 10KV SPD included.Efficiancy : 110LM/W Heat resistant toughened glass is provided with die cast aluminium frame provided with a mounting bracket for aiming adjustment and power factor 0.90 all as specified and directed by Engr-in-Charge. Make : - CG -ORION -2.0/240W or equivalant.
Supply & erect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 metres long) including painting of poles with two coats of aluminium paint over a coat of red oxide primer on all exposed surfaces and black bituminous paint on embedded portion complete all as specified and directed. Make : Shubham Poles /India Tube/Indian Electric pole/Bajaj / Crompton Greaves
Supply and Fixng Pole mounting Junction Box(Loopimg Box ) For street Light for 3 phase 4 wire system with internal size 230x170x105 mm comprising of PVC connection and one MCB 6Amp including Mounting arrengement Make : SINTEX /Havells/ Spelsbary
Supply and fix 3 core 1.5 sqmm PVC insulated PVC sheathed weather proof multistranded copper conductor cable 1100 volts grade drawn through in GI conduit, pole etc from junction box to street light fitting all as specified and directed.
Supply and fixing GI pipe light grade with necessary fittings in floor /piller/fixed on pole of size 40 mm dia complete all as specified
M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed .
M&L for writing pole No. with letters of size 50 mm height on pole/ plate with Black synthetic enamelled paint complete all as specified and as directed by engineer in charge.
M&L for PCC 1:4;8 D2(Using 40 mm graded crushed aggregate)as in Mass concrete for foundation filling of stay and coping including necessary form work all as specified and directed
M&L for PCC 1:3:6 C2(Using 40 mm graded crushed aggregate)as in Mass concrete for foundation filling of stay and coping including necessary form work all as specified and directed
M&L for PCC 1:2:4 B1 (Using 20 mm graded crushed aggregate)as in Mass concrete for foundation filling of stay and coping including necessary form work all as specified and directed
M&L for rendering 10mm thick on fair face of brick work or concrete surface in cement plaster 1:4
Supply & Fix GI tube galvanised light grade 15mm size with alll fitting complete to wall/ceiling or laid on floor and suitable size of clamps minimum 2 Nos per pole with nut bolts all as specified and directed.
Supply and installation CPRI approved LT Electric control panel, cubical type, for Out door use floor mounted made out of CRCA outer sheet of 3 mm thick and inner sheet of 2 mm thick and angle iron legs of size 40mmx40mmx5mm having front and rear open hinged doors with front openable shutters for each MCCB/Timer with spreader compartment with fully enclosed bus bar chamber, having insulated bas bar made but of aluminium strips of rating 150 amps for 3 phase, 415 volts, 50 C/S 4 wire system, with cable entry provision, with suitable lugs gland, voltmeter , Ammeter,CTs and phase indicator complete, duly painted with two coats of stove enameled powder coated paint over as coat of red oxide primer complete and nut,bolt,washers for connection of cable, including necessary PCC work of height 45 cm from ground level and white washing to the platform all as specified and equipped and including S&F with the following items :- (Loc :Perimeter). Make of MCCB : Legrand, Siemens, Schneider.
M & L for earthing complete with galvanised steel plate earth electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25 meter below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to GI wire 4mm at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard/dense soil, returning filling in and removal of surplus soil to a distance up to 50metres, PCC pit in 1:3:6 type CI (using 20mm grade stone aggregate) RCC 1:2:4 type B-1 (using 20mm grade stone aggregate ) 50mm thick pit cover, reinforced with 8mm dia TMT bars 75mm c/c, both ways MS handle 12mm dia, GI funnel, wire mesh and GI watering pipe of 20mm bore GI (light grade) and earth lead protection pipe 20mm bore (light grade) all as specified, directed and shown in electrical plate No 3 of SSR Part-I including testing complete. .
Note : GI strip and protection pipes 20 mm GI light grade up to 7.5 metre is included in unit rate and beyond that the same will be measured separately
Supply & fixing for GI wire 4 mm on wall/batten or recessed or buried in ground all as directed
Supply and Fix Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint
S&F Smoke detector addressable type heat detector with base with rate of rise cum fixed temperature as per IS. 2175 all as directed and as specified. Make: RE 317D SL or as approved by GE.
S&F detector complying with and type certified to EN-45 addressable type multi sensor detector with heat and smoke combination with base with self intelligence as per IS 11360 all as directed and as specified. Make: RE 317D SL or as approved by GE.
S&F Fault isolator(short circuit isolator). Make : RE 717 MI
S&F Manual call point addressable, resetable type all as specified and as directed.. Make : - RE 716
S&F addressable electronic sounder cum strobe all as specified and as directed.. Make : RE 25 SS
S&F addressable Control module all as specified and directed. Make : RE 717 MC
M&L for configuring existing Fire Alarm Control Panel (Make-Ravel AVANI) and linking additional detectors, manual call points, Sounders etc
Supply, laying, testing and commissioning of cabling for fire detection and alarm sysrem with 1.5Sq.mm 2 core annealed tinned multi strand copper conductor PVC Insulated flexible FRLS wire in MS conduit as required. (Cost of MS conduit is deemed to be included) Make :- Polycab / Havalls/ Finolex/ RR kabel /KEI)
M&L for point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable with multistranded copper conductors 1100 volt grade drawn through and including non metallic medium grade rigid PVC conduit accessories including provision of1.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor including fabricated steel terminal box made of GI Sheet concealed in walls of suitable size for fixing switches/sockets etc all specifed for:
a) One exhaust fan point controlled by one, one way 5W 6 Amps
Supply and fix switch piano flush type 5 Amps, one way complete all as specified and directed.
Supply & Fix ceiling rose 65x50 mm Bakelite type,50Hz,230v
Supply & Fix Exhaust fan, AC single phase,230V,50HZ,300 mm sweep with flyguard/louver shutters including suitable size of flexible cable from ceiling rose or connector to exhaust fan and anchoring arrangement in provided space to fix fan all as directed by Eng-in -charge
M&L for providing hole suitable for exhaust fan of 300 mm sweep in stone/brick masonry and making good completely all as specified and directed
Relaying the repaired and serviceable part of the cable in the same trench or new trench as per site conditions, of the following cross-sectional area complete all as specified and as directed. (Note: Excavation, jointing and relaying shall be measured separately under relevant items).
3.5core x 50 sqmm
3.5core x 70sqmm to 3.5core x 120Sqmm
3.5core x 150 sqmm to 3.5core x 185 Sqmm
Taking down the failed cable joint, supply, prepare and connect cable jointing kit for 1.1KV (Earthed) grade cable for outdoor end termination, heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE, armoured aluminium conductor cable of size 50 sqmm complete all as specified and as directed. Make:3M/Reychem/ Dension.
Taking down the failed cable joint, supply, prepare and connect cable jointing kit for 1.1KV (Earthed) grade cable for outdoor end termination, heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE, armoured aluminium conductor cable of size 70 Sqmm to 120 sqmm complete all as specified and as directed. Make:3M/Reychem/ Dension.
Taking down the failed cable joint, supply, prepare and connect cable jointing kit for 1.1KV (Earthed) grade cable for outdoor end termination, heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE, armoured aluminium conductor cable of size 120 Sqmm to 185 sqmm complete all as specified and as directed. Make: 3M/Reychem/ Dension.
Cutting and removing the damaged portion of the LT cable, supply, prepare and connect cable jointing kit for 1.1KV grade cable for heat shrink type straight through joint complete with jointing material and accessories suitable for 3.5 core XLPE, armoured aluminium conductor cable of size 50 Sqmm complete all as specified and as directed. Make:3M/Reychem/Dension. Note: Earth work will measured and paid seperately under relevant items.
Cutting and removing the damaged portion of the LT cable, supply, prepare and connect cable jointing kit for 1.1KV grade cable for heat shrink type straight through joint complete with jointing material and accessories suitable for 3.5 core XLPE, armoured aluminium conductor cable of size 70 Sqmm to 120 sqmm complete all as specified and as directed. Make:3M/Reychem/Dension. Note: Earth work will measured and paid seperately under relevant items.
Cutting and removing the damaged portion of the LT cable, supply, prepare and connect cable jointing kit for 1.1KV grade cable for heat shrink type straight through joint complete with jointing material and accessories suitable for 3.5 core XLPE, armoured aluminium conductor cable of size 120 Sqmm to 185 sqmm complete all as specified and as directed. Make:3M/Reychem/Dension. Note: Earth work will measured and paid seperately under relevant items.
M&L for Chemical Earthing complete with copper earth plate of size 900mm x 600mm x 5mm thick burried in ground vertically to a deapth not less than 5 meter below normal ground level with top edge of plate at a depth not less than 4.25 meter below normal ground level with a bottom layer MG SO4 of 150 mm thick, earth plate surrounded with graphite powder, vegetable soil mxture mixed with bentonite in equal proportion, charcoal and common salt in equal proportion around and 150 mm above the plate and 150 mm thick MG SO4 as top layer and the remaining portion filled with compacted black cotton/ loomy soil and connected with copper strip 32mm x 6mm duly brazed and by means of bolts, nut and washers up to 7.5 meter length and connected to earthing test point, GI pipe light grade 40 mm bore for earth lead protection and GI pipe medium grade 20 mm bore for watering with funnel and wire mesh all as shown in electrical plate No-3 of MES SSR part-I 2009 and specified and testing on completion
including provision of earth pit with necessary earth work, RCC 1:2:4 cover slab 50 mm thick with re-inforcement of 8 mm TMT bars @ 100mm c/c both directions and PCC chamber with PCC 1:3:6 type C2 including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 M complete all as specified and as directed by Engineer-in- charge.
Notes: (i) The length of the copper strip beyond 7.5 meter will be measured and paid seperately . (ii) All joint of copper Strip shall be of brazing only. (iii) Earthing is to be done in front of the Engineer-in-charge (iv) Test result of earthing to be submitted by the contractor for all earthing pits. (v) The contractor shall give guarantee for maintenance earth resistance of less than 1 ohm for a period of 05 (Five) years after certified date of completion and shall deposit security deposit of Rs 2000/- per earthing pit for a period of five years. (vi) Failing to maintain earthing pit result less than 1 Ohm, New earthing pit to be provided by the contractor with out any extra cost. (vii) Necessary earth work excavation in any type of strata, returning filling and making good the surrounding area complete.
Supply and fix or lay in trenches/ wall aluminium copper strip of size 25 mm x 3 mm as earth continuity conductor drawn through rigid non metallic PVC conduit of size 32 mm dia bore and accessories for protection of earthing strip complete all as specified and as directed. Note: Conduit pipe shall me measured and paid seperately under relevant items.
M&L for brass nut, bolts and washers for jointing of copper strip 25 x 3 mm complete all as specified and as directed.
M&L for Porcelain insulator with complete fixing arrangement fixing on wall to protect earthing strip complete all as specified and directed by Engineer in-charge.
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw.
Supply, installing, testing and commissioning of CPRI approved LT distribution panel board Factory Made, cubical, out door type, powder coated with fabricated 3.15 mm thick skelton with angle iron / flat iron frame work , bus Bar chamber,front openable hinged door with locking arrangement and common openable hinged door from rear side, floor mouting type, IP-65 protection and as per IS, comprising the following accessories ,including connecting with the incoming / out going feeders by providing cable glands and cable lugs complete, all as specified and directed.
M&L earthing complete with galvanised steel earth plate electrode 60cmx 60cm x6mm thick burried directly in ground ( earth pit not less than 2.25 mtr below normal ground level ) with top edge of the earth plate not less then 1.5 mtr deep below normal ground level connected to and including galvanised iron strip 25x4 mm as earthing le by means of bolts nuts check nuts and washers of steel after welding of GI tubing light grade protection pipe upto test point. 20 mm dia GI watering pipe with funnel and wire mesh ,PCC pit 1:3:6 with pit cover of size 40mm x 40mm x 4mm ,adquite qty of charcoal dust and salt layers all around the earth plate , removal of surplus soil and returining filling in all as required at site including test point made out of steel plate of Size 75x75x6mm fixed to wall or pole all as specified in plate No 3 of SSR Part-I and directed by Engr- in- Charge.
Notes: On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.
Dismantling ACSR Conductor as directed by Engr in Charge.
THE DECAN ENGINEERING AND REFRIGERATION COMPANY
SRI SAI RAM ENTERPRISES
Srinivash Engineers
M/S - KRUPA ELECTRICALS
POWER CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .