Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr | L1 | Accepted-AOC EMD Refund Vender submitted FDR |
| 2 | L2₹1.5 Cr+₹15.6 L (11.6%)Rejected-Finance | ₹1.5 Cr+₹15.6 L (11.6%) | L2 | Rejected-Finance EMD Refund |
Tender Value
₹1.6 Cr
EMD Value
₹80,829
Closing Date
24 Jan 2023, 5:30 pmClosed
P K JAIN
ISBT, Electric Section
Shifting of HT LT Electrical lines, SITC of Street light infrastructure from Vidhya Sagar Institute Awadhpuri toAmarawat Khurd main road, Bhopal.
2022_UAD_240142_1
2020205764
Open Tender
Electrical Works
Fixed-rate
120 days
ISBT, Electric Section
AS PER TENDER DOCUMENT
14 documents required · 14 mandatory
₹12,500
₹80,829
19 Jul 2023
26 Dec 2022
25 Jan 2023
26 Dec 2022
24 Jan 2023
26 Dec 2022
Amount
Shifting of HT/LT Electrical lines, SITC of Street light infrastructure from Vidhya Sagar Institute Awadhpuri to Amarawat Khurd main road, Bhopal.
1000005515-Automatic timer panel 110A Supply and installation of automatic timer panel of powder coated sheet steel enclosuer surface mounted having astronomical time switch , contecter ,MCCB , MCB, required all materials including PVC cables etc complete in all respect of Indoasian, Havells, Schneider, L&T make only with 24 months guarrantee
3000012313-100 KVA Energy efficiency level -3 Supplying, installing, testing and commissioning of 11/0.4 KV 3 Phase 50 cycle oil immersed, naturally cooled, outdoor type transformer connected delta on H.T. side and star on L.T. side, dehydrating silica gel breather on eye level, rating and diagram plate, two earthing terminal, lifting lugs, oil level gauge, drain valve with plug, temperature not exceeding 50ºC on load, oil filling hole with plug, four unidirectional roller, arcing horns, explosion vent, terminal arrangement bushing on H.V. side and cable box on LV side, first filling of oil upto desired level and transformer installing on existing structure with all required materials arrangement as required ISI marked & as per IS specification, hand operated off load tap changer switch above 100 KVA, oil conservator with drain valve, plug 63 KVA and above. 100 KVA Energy efficiency level -3 Aluminium wound (AS PER PWD SOR 2022)
3000012314-200 KVA Energy efficiency level -3 Supplying, installing, testing and commissioning of 11/0.4 KV 3 Phase 50 cycle oil immersed, naturally cooled, outdoor type transformer connected delta on H.T. side and star on L.T. side, dehydrating silica gel breather on eye level, rating and diagram plate, two earthing terminal, lifting lugs, oil level gauge, drain valve with plug, temperature not exceeding 50ºC on load, oil filling hole with plug, four unidirectional roller, arcing horns, explosion vent, terminal arrangement bushing on H.V. side and cable box on LV side, first filling of oil upto desired level and transformer installing on existing structure with all required materials arrangement as required ISI marked & as per IS specification, hand operated off load tap changer switch above 100 KVA, oil conservator with drain valve, plug 63 KVA and above. 200 KVA Energy efficiency level -3 Copper wound Aluminium wound (AS PER PWD SOR 2022)
3000012319-Fencing of chain 12 SWG GI Supply & fixing fencing of chain link mesh 100 x 100 mm, 12 SWG GI wire for for D.P. structure electric sub-station switch yard including single post of angle iron size 50x50x5mm, 2.5 mt long should be provided upto 2.00 mt. apart or as required. The panel frame with required angle iron/ flat iron members/cross members including mesh welded in frame panel shall be erected between the posts. The angle iron post shall be erected in cement concrete M-15 (1:2:4) (20 mm graded metal) foundation, including excavation of pit and refilling the same. The fencing shall be provided with one entrance gate including locking arrangement as required as per specification. The height of fencing shall be 2 mt. above ground level. Fencing shall be painted with required shade. Fencing of chain link mesh 100x100 mm, 12 SWG GI wire (AS PER PWD SOR 2022)
3000012322-Spreading of metal dust, murum Collection and spreading of metal dust, murum and 40mm graded hard metal in sub-station yard or as required as mentioned below - Metal dust Spreading of metal dust, murum (AS PER PWD SOR 2022)
4000000785-Shifting, erection, & commissioning Shifting, erection, & commissioning of 100/200/315/500 KVA (11/0.433 KV) distribution transformer on existing structure including Bi-metallic clamp, ACSR/AAAC Conductor i/c colour code sleeve, for connection from H.T. Line to transformer as required as per s pecification. Shifting, erection, & commissioning of 100/200/315/500 KVA (11/0.433 KV) distribution transformer (AS PER PWD SOR 2022)
3000012335-3x95 sq.mm, 1x16(st. light), 1x50 Supplying & drawing/laying of PVC insulated XLPE aerial bunch power cable conductor H2/H4 grade aluminium solid/stranded conforming to IS-14255- 1995, alu. alloy insulated messenger 1100 volts grade cable of approved make in air with necessary material as per specification of required size as mentioned below – 3x95 sq.mm, 1x16(st. light), 1x50(insulated neutral Single core cable (AS PER PWD SOR 2022)
3000012336-3x120 sq.mm, 1x16(st. light), 1x70 Supplying & drawing/laying of PVC insulated XLPE aerial bunch power cable conductor H2/H4 grade aluminium solid/stranded conforming to IS-14255- 1995, alu. alloy insulated messenger 1100 volts grade cable of approved make in air with necessary material as per specification of required size as mentioned below – 3x120 sq.mm, 1x16(st. light), 1x70(insulated neutral Single core cable (AS PER PWD SOR 2022)
3000012337-3x150 sq.mm, 1x35(st. light), 1x95 Supplying & drawing/laying of PVC insulated XLPE aerial bunch power cable conductor H2/H4 grade aluminium solid/stranded conforming to IS-14255- 1995, alu. alloy insulated messenger 1100 volts grade cable of approved make in air with necessary material as per specification of required size as mentioned below – 3x150 sq.mm, 1x35(st. light), 1x95(insulated neutral Single core cable (AS PER PWD SOR 2022)
3000012353-Spring loaded busbar 3Ph, 1In+6Out Supplying &fixing of spring loaded busbar screwless connector with enclosure of approved make including required clamp, nut, bolt, connection, testing as per specification to complete the job. Spring loaded busbar Three Phase 3Ph, 1In+6Out (AS PER PWD SOR 2022)
3000012338-LT trivector energy meter Supply, installation, testing & commissioning of LT trivector energy meter, DLMS compliant category-A (for substation/feeder metering) , 3 phase 4 wire, 440 Volts, 5 Amp, accuracy class 0.5S with GSM(GPRS compatible) modem suitable for required C.T. 5A duly tested from electricity board with uPVC box .LT trivector energy meter (AS PER PWD SOR 2022)
4000000784-Covered conductor 70 Sq. Mm. XLPE insula Covered conductor 70 Sq. Mm. XLPE insulation for 11 KV
3000013647-Covered conductor 99 Sq. Mm. XLPE insula Covered conductor 99 Sq. Mm. XLPE insulation for 11 KV
3000012274-AAAC conductors Dog Supplying and drawing all aluminium alloy conductor (AAAC) of approved make conforming to IS 398-1979 Pt. IV, including binding at existing insulator, jointing, jumpering, tearing off, connecting etc. as required including clearing of obstacles (if any) AAAC 0.1 sq inch (100 sq.mm Al. EQ.)- AAAC conductors Dog ( AS PER PWD SOR 2022)
3000012351-Spring loaded busbar 1Ph, 1In+4Out Supplying &fixing of spring loaded busbar screwless connector with enclosure of approved make including required clamp, nut, bolt, connection, testing as per specification to complete the job. 1Ph,1In+4Out (AS PER PWD SOR 2022)
3000015040-ACSR 0.1 sq inch (100 sq.mm Al. EQ.)Dog Supplying and drawing of stranded aluminium conductor steel reinforced (ACSR) conforming to IS:398-1976 of approved make, stringing, making off complete with binding at existing insulator, jointing, jumpering, tearing off, connecting etc. as required and clearing of obstacles (if any) etc. ACSR 0.1 sq inch (100 sq.mm Al. EQ.)- (Dog) ( AS PER PWD SOR 2022)
4000000940-150 watt LED Supply and installation of high efficiency LED street light luminaries with high pressure die cast aluminum body (make embossing on body) with toughened glass cover on existing electric pole. The fitting should be IP66, IK-08, with power factor >0.95 The color temp of the LED should be 5000 K - 5700 K with color rendering index >70. THD less then 10%. The total system output should be not less than 110 lumens/ watt & total wattage should be 150 w ± 5W. The LED fitting should have L70 life of more than 50000 burning hours at 35 degree ambient temp. Surge protection should be more than 4 KV internal and 10KVexternal. The LED should have individual optic lenses and bat wing photometry suitable for street light. The LED fitting should be provided with 5 years guarantee for free repairing/maintenance or replacement of LED light fitting, LED, driver, surge protector, toughened glass cover etc. on stamp paper with service center details. LM79-80 report with batch no. of supply must be supply at the time of delivery, BIS certificate is must be submitted with catalogue/model no. Spare part list of driver, cover and LED must be submitted before.including Providing and fixing of sword canopy type double arm GI bracket upto 2 Mtr. Long for street light pole.
Bidder Name
Amount
JAGDAMBA FOUNDATION(GSTN-23ALQPR4323N1ZM)
SHRI HARI ELECTRICALS(GSTN-23BWYPS4386Q1Z5)
SHRI HARI ELECTRICALS
SHRI HARI ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .