Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.0 LAccepted-AOC NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹34.4 L+₹2.1 L (6.43%)Rejected-AOC | L2 | Rejected-AOC AS PER BOQ | |
| 3 | L3₹34.9 L+₹2.6 L (8.18%)Rejected-AOC MAIN ROAD KANDOLI NAGROTA JAMMU J K 181221 | JAMMU | JAMMU AND KASHMIR | 181221 | L3 | Rejected-AOC AS PER BOQ |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
25 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Army Dhar Road Udhampur
GE Army Dhar Road Udhampur
REPAIR OF ROOFS OF BLDG IN ADM AND DEPOT AREA AT JINDRAH UNDER GE (ARMY) DHAR ROAD
2021_MES_479013_1
8067/NIT-50/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
Jindrah under GE Army Dhar Road Udhampur
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE Army Dhar Road Udhampur
₹70,000
Yes
5 Nov 2021
1 Oct 2021
27 Oct 2021
1 Oct 2021
25 Oct 2021
12 Oct 2021
1 Oct 2021 - 11 Oct 2021
60 days
Amount
Taking down existing roof treatment of water proofing of any description including plaster and cleaning top surfaces with wire brushes complete all as specified and directed.
10mm thick plaster in cement mortar 1:3 mixed with and incl water proofing compound @ 3% by weight of cement applied over roof slab. After the plaster is cured the roof will be tested for water tightening by ponding with water for seven days for any seepage/leakage etc. if any seepage is observed the rectfication shall be carried out by high pressure grouting under the pressure of 5 Kg/Sqm using cement grout. After the surface is repaired the slab is tested for water tightness again before processing further treatement complete all as specified and directed
Sel adhesive elastomeric SBS bitumen based water proofing membrane 1.5mm thick with coarse laminated polythene film surface. The upper side and easily removable silicon film on the underside, laid on roofs and sealing all joints and including applying bitumen primer @ 0.30 ltrs/Sqm over clean RCC roof surface complete all as specified and directed. Note : The work shall only be executed through authorised approved applicator by the manufacturer of membrane) Make : Hyplas of IWL India ltd Chennai/Texas India Ltd Gurgaon and its equivalent
M & L for 6 mm thick asbestos cement serrated ridge for corrugated or semi corrugated sheets fixed with L type or J type or cranked hook bolts complete all as specified and directed
M & L for 6 mm thick asbestos cement, corrugated or semi corrugated sheets in roofs, walls etc., fixed with L type of J type or cranked hook bolts complete all as specified and directed
M & L for 6 mm thick asbestos cement, corrugated or semi corrugated sheets in roofs, walls etc., fixed with L type of J type or cranked hook bolts (except sheets) (serviceable sheets obtained from dismantling items shall be used) complete all as specified and directed
Dismantling AC Sheets of any description in roof covering including ridge, wind tie etc complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed
S & F rolled mild steel work in tubular trusses, purlins etc. including special shaped etc complete using ERW or induction butt welded tubes conforming to Gde St-240 and painted one shop coat of zinc chromate primer paint (including preparation of surface) at contractor's workshop before fabrication complete all as specified and directed.
Refixing and fabrication only rolled mild steel work in tubular trusses, purlins etc. including special shaped etc complete using ERW or induction butt welded tubes conforming to Gde St-240 and painted with one coat of zinc chromate primer paint (including preparation of surface) at contractor's workshop before fabrication complete all as specified and directed.
S & F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
S & F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws (for Ridge) complete all as specified and directed
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stoneswork and precast concrete articles complete all as specified and directed
M & L brick work with sub class 'B' bricks, straight or curved on plan exc. 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L brick work with sub class 'B' bricks, straight or curved on plan exc. 6 mtr mean radius built in cement mortar 1:6 but (except bricks) complete all as specified and directed.
Dismantling of existing water proofing treatment (unreinforced cement concrete polymeric water proofing membrane and cement mortar) not exceeding 15 cm thickness above the ground level complete all as specified and directed.
25mm thick plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate and finishing the surface even and smooth as in padding concrete/roof slab including mixing of Water proofing compound complete all as specified and directed.
Rendering 10mm thick on fair faces of brick work or concrete surfaces finished even and fair on walls in cement mortar(1:4) , using water proofing compound complete all as specified and directed. (Note : WPC will be measured and paid for separately)
Supply only integral water proofing compound, ISI marked, complete all as specified and directed.
M & L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per square metre including cleaning surfaces complete all as specified and directed.
M & L for fixing APP based polymeric membrane minimum weighing not less than 3kg/sqm and minimum 3mm thick reinforced with polyester non-woven fabric (weight not less than 150 gm/Sqm) laid on primed surface of roofs using butane torch, and sealing all joints after and including applying bituminous primer @ 0.40 litre per square metre over clean RCC roof surfaces, complete all as specified and directed.
Taking down cement or cement lime plaster, any description on brick or stone or cement concrete walls etc. including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster in CM 1:6 on fair faces of brick work or concrete surfaces finished finished even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick in CM 1:4 on other than fair faces of brick work or cement concrete surfaces finished fair and even without using extra cement complete all as specified and directed
M & L for rendering 5 mm thick in CM 1:4 on fair faces of bricks or concrete as in ceiling finished even and smooth without using extra cement complete all as specified and directed
M & L for preparation of new plastered surface of walls, priming plastered and other surfaces with a coat of alkali resistant priming paint and applying two coats of cement base paint white or tinted compelete all as specified and directed
M & L for preparation of new plastered surfaces on walls, priming plastered and other surfaces with alkali resistant priming paint and applying two coats with distemper oil emulsion, white or tinted complete all as specified and directed.
M & L for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified and directed.
M & L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a priming coat of red oxide zinc chrome primer complete all as specified and directed.
M & L for preparation of old painted steel surfaces of any description, over 10 cm width or girth, not other wise described and applying one coat of synthetic enamel paint complete all as specified and directed.
Dismantling timber scantlings under 40 sqcm and over in section, as in fillets, rails, rafters, purlins etc unframed work complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, gypsum, POP, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
4mm thick Asbestos Cement plain building boards fixed to MS work/timber framework with screws complete all as specified and directed.
Providing and fixing of designer ceiling board of size 600 x 600x4mm thick pre-painted ceiling board tiles of approved texture at all height laid on hot dipped galvanised iron imposed grid system with 24mm wide T-section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33mm thick GS sheet and of size 24x32x3000mm and spaced at 1200mm centres securely fixed to the structural soffits by approved hangers at 1200mm maxiumum centres. Hangers of GI wire 4mm dia to be fixed by approved rawl plug, level and justers and screws etc. The last hanger at the end of feach main runner shall not be greater than 450mm from adjacent wall. Flush fitting of 1200 mm long cross tee (with double stitching) to be interlocked between main renders at 600mm to be supoorted independently. 600x600mm modules to be formed by fitting 600mm long cross tee centrally between the 1200mm cross tee. Tee, Permimeter wall angle shall be of 0.45mm thick GS sheet, complete all as specified and directed. (Make : Saint Gobain, Everest)
Disconnecting existing tanks exc 250 and not exc 500 ltrs, including cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes etc and setting aside (or lowering if required) for repairs, cleaning etc., and hoisting if required reconnecting and refixing in position complete all as specified and directed.
Disconnecting existing tanks exc 500 and not exc 1000 ltrs, including cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes etc and setting aside (or lowering if required) for repairs, cleaning etc., and hoisting if required reconnecting and refixing in position complete all as specified and directed.
M & L for taking up or down steel tubing and connections 15 mm bore incl cleaning for refixing or removal to store complete all as specified and directed.
M & L for taking up or down steel tubing and connections 20 mm bore incl cleaning for refixing or removal to store complete all as specified and directed.
S&F GI water tubing 15 mm bore medium grade galvanised with all fittings and fixed to wall & ceiling or laid in floors, bore of pipe 15mm complete all as specified and directed
S&F GI water tubing 20 mm bore medium grade galvanised with all fittings and fixed to wall & ceiling or laid in floors, bore of pipe 20mm complete all as specified and directed
M & L for 100mm thick plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate and finishing the surface even and smooth as in padding concrete/roof slab for water tank complete all as specified and directed.
Demolition of cement concrete ( reinforced) other than ground floors, beams stair cases, landings, chajjas and similar suspended work not exc. 15 cm thick (reinforcement cut as required to facilitate demolition) complete, all as specified.
Use and waste form work to sides and soffits of floor or roof beams, beams haunching, girders, bressummers, lintels, cantilevers, shelves including supports, over hangs, etc. also splays between floors and beams etc for flat rough finished surfaces of concrete complete all as specified and directed.
Use of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete walls, floor and roofs not exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but not exc 20 cm wide for rough finished surfaces of concrete complete all as specified and directed
M & L mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L mild steel TMT bars 6 mm to 8 mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for providing RCC 1 : 2 : 4 Type B1 (20 mm graded aggregate) for slabs supported on walls, beams and column in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed
M/S PAWAN KUMAR ANAND
M/S SANJAY STEEL WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .