Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.2 LAccepted-AOC | L1 | Accepted-AOC Accepted due to lowest rate quoted | |
| 2 | L2₹30.4 L+₹1.0 L (3.52%)Rejected-Finance | L2 | Rejected-Finance Rejected due to highest rate quoted. | |
| 3 | L3₹36.5 L+₹7.2 L (24.4%)Rejected-Finance 20 8 EWS PREETAM NAGAR COLONY ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | 211001 | L3 | Rejected-Finance Rejected due to highest rate quoted. |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
18 Jul 2024, 6:00 pmClosed
GE (AF) GURGAON
GE (AF) GURGAON
REPAIR/REPLACEMENT OF ROOF TREATMENT CHAJJAS PARAPET WALL TANK CLEANING ROOF SHEETS PERIODICAL SERVICES INCL INTERNAL ELECTRICAL WORKS IN DOMESTIC AND TECHNICAL AREA AND SEWAGE LINES MANHOLES SEPTIK TANK BRICK DRAIN ETC AT AF STN NERELA UNDER GE AF G
2024_MES_660926_1
GE/GUR-/NIT-10/2024-25
Open Tender
Civil Works
Item Rate
240 days
GE (AF) GURGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) GURGAON
₹99,000
4 Sept 2024
20 Jun 2024
20 Jul 2024
20 Jun 2024
18 Jul 2024
4 Jul 2024
Amount
Demolition of Mud in roofs, any thickness including plastering and leeping, (whether full thickness removed etc including roof tiles complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) of any description & in any position not specifically provided complete including dismantling of floor tiles etc complete all as specified and as directed.
M&L for 50 mm thick PCC (1:2:4) type B-0 (Using 12.50mm graded stone aggregate) as in roof padding complete all as specified and as directed.
M&L for 15 mm thick plaster in cement mortar (1:4) mixed with water proofing compound on roof slabs finished even and smooth (without using extra cement) after cleaning of roof surfaces with wire brushes complete all as specified and as directed. Notes : WPC shall be measured and paid seperately.
M&L for water proofing treatment with APP (Atactic Polypropylene) modified polymeric prefabricated five layer membrane over roof consisting of cleaning of concrete or plaster surface of roof & parapet walls and applying evenly a bitumen primer confirming to IS 3488 @ 0.40 Kg per sqm laid using buten torch and sealing all joints of APP modified polymeric water proofing membrane minimum weight 3.6 kg/sqm reinforced with non woven polyester fabric (weight not less than 160 grams per sqm) unrolled and bonded to substrata with logitudinal and end laps 100 mm and 150 mm respectively as per manufacturer's instructions complete all as specified and as directed.
M&L for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed.
M&L for providing plain cement concrete (1:2:4) type B0 (using 12.5 mm graded crushed stone aggregate) as in coping in chajjas or roof kerbs on roof chamfered on edge including trowelling slightly complete all as specified and as directed.
M&L for Cement concrete tiles 25cm x 25cm x 22 mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors, and cut and polished, set with grey cement and pigments over 15mm thick cement screed bed in cement mortar 1:4 complete all as specified and as directed.
Supply only intergral water proofing compound ISI Marked complete all as specified and as directed.
Removing bldgs demolished materials / debries exc. 1.50 km but n exc. 5 km and depositing where directed complete all as specified and as directed.
M&L for preparation of plastered or unplastered old decorated surfaces by complete removal of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7"/9" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible , filling of holes and cracks with with suitable material like cement or plaster of paris etc and thereafter applying two coat of oil bound distemper over a coat of primer on walls complete all as specified and as directed. Note : (a) Each stage of complete removal of existing treatment and preparation of surfaces after applying putty shall be got approved from Engg-In-Charge in stage passing register before applying the finishes coat. (b) Material shall be procured from manufacturer and work shall be got executed through authorised applicators of manufacturer. (c) Wall care putty shall be measured and paid seperately.
All as per item No.11 here-in-before but on surfaces of ceiling complete all as specified and as directed.
M&L for preparation(complete removal of existing treatment) of old decorated external wall/ceiling surface of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7"/9" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying Two coats of wheather proofing exterior acrylic emulsion paint over a coat of primer premium quality on wall/ceiling surface including applying 1-2mm thick wall care putty over disturbed surface during preparation of any reason, sand papering thus make surface smooth upto 4th storey buildings complete all as specified and as directed. Note : (a) Each stage of complete removal of existing treatment and preparation of surfaces after applying putty shall be got approved from Engg-In-Charge in stage passing register before applying the finishes coat. (b) Material shall be procured from manufacturer and work shall be got executed through authorised applicators of manufacturer.
M&L for preparation(complete removal of existing treatment) of old decorated external wall/ceiling/roof sheet surface of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7"/9" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying Two coats of wheather proofing exterior acrylic emulsion paint ( Camouflage Pattern) over priming coat premium quality on wall/ceiling surface including applying 1-2mm thick wall care putty over disturbed surface during preparation of any reason, sand papering thus make surface smooth upto 4th storey buildings complete all as specified and as directed. Note : (a) Each stage of complete removal of existing treatment and preparation of surfaces after applying putty shall be got approved from Engg-In-Charge in stage passing register before applying the finishes coat. (b) Material shall be procured from manufacturer and work shall be got executed through authorised applicators of manufacturer.
M&L for preparation(complete removal of existing treatment) of old decorated external wall surface by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7"/9" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying two coat of cement base paint on walls complete all as specified and as directed. Note : Stage for Preparation of surfaces shall be got approved from Engg-In-charge in stage passing register before applying the finishes coat
M&L for providing 1-3mm thick wall care putty on wall before applying oil bound distemper and making the surface uniform complete all as specified and as directed. Note: OBD to be measured and paid saperately.
M&L for providing 1-3mm thick wall care putty on ceiling before applying oil bound distemper and making the surface uniform complete all as specified and as directed. Note: OBD to be measured and paid saperately.
M&L for preparation of old treated plastered or unplastered surfaces of walls including cornices by brooming down or steel wire brushing, scraping down, smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spot, filling cracks/holes with putty and applying one coat of distemper oil emulsion on walls complete all as specified and as directed.
M&L for preparation of old treated plastered or unplastered surfaces of ceiling including cornices by brooming down or steel wire brushing, scraping down, smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spot, filling cracks/holes with putty and applying one coat of distemper oil emulsion on ceiling complete all as specified and as directed.
M&L for preparation of old painted surfaces of wood and wood based material of any description over 10cm width or girth by cleaning, sand papering,brushing etc , filling in cavities and cracks etc with approved filler and applying one coat of synthetic enamel paint to give an even and smooth surface having no sign of brush marks complete all as specified and as directed.
M&L for preparing old painted surfaces of steel and iron surfaces over 10 cm in width or girth by cleaning, sand papering, brushing with wire brushes, scrapping by steel scrappers etc and applying one coat of synthetic enamel paint to give an even and smooth surface having no sign of brush marks complete all as specified and as directed.
M&L for preparation of old painted concrete surface plain/kerb stone moulded over 10cm width or girth by cleaning, brushing etc and applying one coat of synthetic enamel paint complete all as specified and as directed.
Demolition of brick work or rubbled stone masonry including all quoins arches , pillars etc built in cement mortar and including removal from the site complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc and including removal of debris and rubbish from the site complete all as specified and as directed.
M&L for brick work with sub class 'B' old size brick, straight or curved on plan exc 6.0 mtr mean radius built in cement mortar 1:6 etc complete all as specified and as directed.
M&L for half brick work with sub class 'B' old size brick, straight or curved on plan exc 6.0 mtr mean radius built in cement mortar 1:4 etc complete all as specified and as directed.
M&L for 5 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar 1:3 in ceiling including finishing surface even and smooth without using extra cement complete all as specified and as directed.
M&L for 10 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar 1:6 on walls including finishing surface even and smooth without using extra cement complete all as specified and as directed.
M&L for 15 mm thick plaster in cement mortar (1:4) on brick or concrete surfaces including rendering on fins, fascias, chajja, parapets etc and finishing the surfaces even and fair (without using extra cement) complete all as specified and as directed.
M&L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of primer complete all as specified and as directed.
M&L for preparation of newly plastered surface of ceiling and applying two coats of oil bound distemper over one coat of primer complete all as specified and as directed.
M&L for preparation of newly plastered surface of wall and applying Two coats of wheather proofing exterior acrylic emulsion paint over a coat of primer premium quality complete all as specified and as directed.
M&L for preparation of newly plastered surface of wall and applying Two coats of wheather proofing exterior acrylic emulsion paint ( Camouflage Pattern) over a coat of primer premium quality complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint on walls complete all as specified and as directed.
Disconnecting existing PVC water tank of capacity exc. 250 ltr but not exc. 500 ltr, setting aside for lowering down if required for repairs,hoisting if required reconnecting and refixing in position on roof including cleaning of Overhead tank & removing the sludge washing down with detergent/ bleaching powder and writing the date of cleaning with suitable paint complete all as specified and as directed.
Disconnecting existing PVC water tank of capacity exc.500 ltr but not exc. 1000 ltr, setting aside for lowering down if required for repairs,hoisting if required reconnecting and refixing in position on roof including cleaning of Overhead tank & removing the sludge washing down with detergent/ bleaching powder and writing the date of cleaning with suitable paint complete all as specified and as directed.
Dismantling of existing water tanks of steel/PVC/AC of capacity exceeding 250 liters but not exceeding 500 litres complete all as specified and as directed.
Dismantling of existing water tanks of steel/PVC/AC of capacity exceeding 500 liters but not exceeding 1000 litres complete all as specified and as directed.
S&F for rotational moulded polyethylene water storage tanks 500 ltrs capacity (cylinderical vertical with closed top triple layered) hoisted and fixed in position all as per SSR Part I complete all as specified and as directed.
S&F for rotational moulded polyethylene water storage tanks 1000 ltrs capacity (cylinderical vertical with closed top triple layered) hoisted and fixed in position all as per SSR Part I complete all as specified and as directed.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
M&L for Cutting chases, pinning in. making good to facings where required andpointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in brick wall etc complete all as specified and as directed.
S&F medium grade galvanized steel tubing with all fittings & fixed complete to walls & ceiling or laid in floors 15 mm dia bore pipe (including in short length) complete all as specified and as directed.
S&F tubes medium grade galvanized with all fittings & fixed complete to walls & ceiling or laid in floors 20 mm dia bore pipe (including in short length) complete all as specified and as directed.
S&F in repair 20 mm dia Gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description complete all as specified and as directed.
S&F rolled mild steel in framed work as in doors or steel gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing conforming to Fe- 290.Gde-E-165 complete all as specified and as directed.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and as directed.
M&L for prepration of new Steel surfaces of any description, not otherwise described, over 10cm width or girth & applying two coats of synthetic enamel paint complete all as specified and as directed.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with selftapping screws complete all as specified and as directed.
S&F in repair steel rolling shutter of thickness 1.25 mm without ball bearing as specified including top cover , anchoring rod , hasp and staple and one shop coat of primer erected in position, gear operated type with bevel gear box and crank handle complete all as specified and as directed.
M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregates) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified and as directed.
M&L for 75 mm thick cement concrete type D-2 1:4:8 with )using 40 mm graded stone aggregates) as in sub base of flooring etc complete all as specified and as directed.
M&L for sand filling under interlocking tiles for cushioning including watering and consolidation complete all as specified and as directed.
M&L for machine presssd pre-cast coloured concrete interlocking paver block any shape confirming to IS-15658-2006 of 60mm thick , M-35 Grade with grey cement and pigment as approved complete all as specified and as directed.
M&L for screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and as directed.
M&L for chequered cement concrete coloured tiles 30cm x 30 cm x 25mm, set jointed and pointed in neat cement slurry in floors with grey cement and pigment complete all as specified and as directed.
M&L for cement concrete type B0 1:2:4 (using 12.50 mm graded stone aggregate) as in coping benching, gola, slightly rounded and similar items complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for cement concrete (1:2:4) type B-0 (using 12.5 mm graded stone aggregates) 25 mm thick as in sub base of flooring/tiles etc complete all as specified and as directed.
M&L for screed bed or bedding layer of mortar 20 mm thick in cement mortar (1:4) for bedding of tiles complete all as specified and as directed.
M&L for screed bed or bedding layer of mortar 15 mm thick in cement mortar (1:6) for bedding of tiles complete all as specified and as directed.
M&L for 10 mm thick rendering in cement mortar (1:4) on vertical surfaces for backing of tiles complete all as specified and as directed.
M&L for Coloured Vitrified Ceramic tiles 9-10 mm thick (Square/rectangular) of light Shade , polished, area of each tile not exceeding 0.36 sqm, fixed in floor/skirting etc over set and jointed in neat cement slurry and pointed in coloured cement to match with coloured tiles complete all as specified and as directed.
M&L for Machine cut kota stone slab flooring/skirting 20-25mm thick overcement screed base laid and jointed with grey cement slurrymixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and as directed.
Taking down wall panelling and similar work complete all as specified and as directed.
S&F for solid colour wood grain printed PVC sheets 5mm thick as in wall panelling inclusive of solvent cement incl necesssary PVC frame work for fixing on brick or concrete wall as per specification and drawing complete all as specified and as directed.
Dismantling ceiling board (fiber, pulp insulation) or insulation board/slabs etc including grid work/wooden or aluminium frame works, cover fillet etc complete all as specified and as directed.
M & L for clip in type armed strong metallic powder coated 0.5mm thick ceiling with GI framework made of standard Tee , Angle or any other section as in grid type ceiling framework as approved by GE . Ceiling shall be hanged to roof trusses / purlin rafters with the help of GI wire not less than 4mm dia at an interval n. exc 1m , the size of the metallic powder coated ceiling tiles 600 mm x 600 mm complete all as specified and as directed.
M&L for guniting work to RCC work in column, flooring, side walls, beam, slab, etc by removing loose concrete cover etc, cleaning of surface with wire brush and applying epoxy paint to rusted reinforcement and S&F welded wire mesh fabric or wire net less than 95 X 95X 3 mm adhesive, plaster grade for concrete admixture 1 part of cement and 3.5 part of sand and average thickness 40 mm and making the surface even including 15mm thick plastering in cement mortar (1:4) on brick or concrete surfaces including finishing the surfaces even and smooth, without using extra cement plumb and making surface true to geometry in line and including necessary form work to be carried at upto double storey building Note.- Where ever reinforcement required will be measured and paid seperatly etc complete all as specified and as directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.5 sqm each complete all as specified and as directed.
All as per item No.73 here-in-before but exc 1.5 Sqm and not exc 4 Sqm each complete all as specified and as directed.
Taking down chowkhats or frames not exc. 1.5 sq. m each complete all as specified and as directed.
All as per item No.75 here-in-before but exc 1.5 Sqm and not exc 4 Sqm each complete all as specified and as directed.
Taking down shutter of any description exc 1 Sqm and n exc 2 Sqm and removing from site complete all as specified and as directed.
S&F for Pressed steel frames 125X60mm (made out of 1.25mm thick MS Sheet) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and as directed.
S&F for Pressed steel frames 105X60mm (made out of 1.25mm thick MS Sheet) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and as directed.
S&F factory made 35mm thick flush shutters , solid core construction with block board core and plywood face pannel commercial type on both faces complete all as specified and as directed.
S&F factory made 35mm thick 2nd class hardwood glazed and skelton door shutters, open rebated and prepared to receive glass, gauze, (without sash bars) edges for framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc, sizes of members of shutters as specified in SSR Part-1 section 8 clause 8.24 (a) fitted to chowkats complete all as specified and as directed.
S&F solid PVC door frame of size 50mm X47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube supplying and fixing in opening as per specification and drawing complete all as specified and as directed.
S&F factory made PVC shelter panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement , supplying and fixing in the frame at site as per specification & drawing complete all as specified and as directed.
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple including necessary beading complete all as specified and as directed.
S&F in repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple including necessary beading complete all as specified and as directed.
M&L for preparation of new or previously untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed.
S&F 100 mm Butt hinges, Stainless steel and fixed complete all as specified and as directed.
S&F 200mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed.
S&F 150 mm size extruded aluminium alloy handles fabricated type anodised and fixed complete all as specified and as directed.
S&F 250 mm long aluminium alloy anodised sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast sections or cast aluminium alloy complete all as specified and as directed.
S&F in repair 200mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed.
S&F in repair 150 mm size extruded aluminium alloy handles fabricated type anodised and fixed complete all as specified and as directed.
S&F in repair 250 mm long aluminium alloy anodised sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast sections or cast aluminium alloy complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or escription) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed.
S&F sheet glass 4 mm thick ordinary quality and glazing with oil putty or wooden beads complete all as specified and as directed.
S&F Powder coated Aluminium frame for doors, windows, ventilators with or more rebates incl. jointing cleat for fixing etc. complete all as specified and as directed.
S&F powder coated anodized aluminum door shutters, aluminum section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing handles 2 Nos in each door,100 mm long hinges (3 Nos), anodized aluminum snap beading screws etc. complete all as specified and as directed.
S&F powder coated Anodised aluminium window and ventilator shutters, fixed/side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed.
S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as specified and as directed.
M&L for 5.5 mm thick sheet glass ordinary quality and glazing each pane fixed with including neopune rubber gasket in aluminium frame work complete all as specified and as directed.
S&F window or ventilators section of frame 72x55mm fixed to wall or concrete surface with rowl plugs made of galvanised steel powder coated and section of shutter 47x20mm mulion section 72x50mm (Based steel as per IS 513 "D" quality galanised as per IS 277 with zinc of 120 gms/sqm) glazed or gauged and wire gauge shutter prepare to receive wire mesh to the shutter (Double door shutter) with total coated thickness of 0.6mm including grills/guard bars made of square bars powder coated fixed to window frame with screws including necessary fittings and all builders hardware such as handles, tower bolts and stays etc complete all as specified and as directed. Make : NCL type-4000 Series (Note : Glass and wiremesh shall be measured and paid separately under respective items)
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition ) of any description in any position not specifically provided complete complete all as specified and as directed.
Dismantling posts or struts (wood, steel, or RCC) any section, including taking out embedded portion and making good disturbed ground posts embedded in concrete brick work masonry etc complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
S&F rolled mild steel in framed work as in doors or steel gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing conforming to Fe- 290.Gde-E-165 complete all as specified and as directed.
S&F Mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes for notching of wire, etc, flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and as directed.
M&L for excavating in post holes (or similar holes) each n.exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in soft and loose soil complete all as specified and as directed.
M&L for cement concrete type B-2, 1:2:4 (40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
Taking down barbed wire fencing of any description and in any position fixed to RCC/steel posts complete all as specified and as directed. (each row shall be measured separately).
S&F Galvanised, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins etc complete all as specified and as directed. (each line wire to be measured).
S&F in repair re-inforced punched concertina coil of 900 mm dia (chrome razer or blade wire) with barbed tape of 0.50 mm thick galvanised steel steel sheet or core wire of dia 2.5mm of high tensile steel wire including galvanised mild steel staple/clips for tying at crossing etc complete all as specified and as directed.
S&F in repair re-inforced punched concertina coil of 600 mm dia (chrome razer or blade wire) with barbed tape of 0.50 mm thick galvanised steel steel sheet or core wire of dia 2.5mm of high tensile steel wire including galvanised mild steel staple/clips for tying at crossing etc complete all as specified and as directed.
Dismantling fencing wire mesh, any type complete all as specified and as directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and as directed.
Supply only Chain link MS galvanised fencing, any size or type complete all as specified and as directed.
S&F 11 to 15 mm dia of shank mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other end,or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut but length exc 5 cm and n exc 10 cm long complete all as specified and as directed.
S&F Mild Steel round bar 10 dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips for Gd.I, Fe-432 (Part I) complete all as specified and as directed.
M&L for Providing precast cement concrete louvres and jallies, 25 mm thick type B-0 1:2:4 (using 12.50 mm graded stone aggregate (measured solid), including all mouldings but excluding frame , set in cement mortar (1:6) complete all as specified and as directed.
Desludging of manholes mechanically by removing all loose materials and sludge and cleaning the same with water by Jet Machine and removal of sludge/silt/liquid/mud and sand (in foul position) etc outside the MOD land ,depth of manholes not exc 1.00 mtr complete all as specified and as directed.
All as per item No. 120 here-in- before,but depth of manholes exc 1.00mtr and n.exc 2.00 mtr complete all as specified and as directed.
Cleaning and desludging of existing sewage line of 100 mm to 200 mm bore and depth up to 2.00 mtr from manhole to manhole complete desludging by means of mechanically (Jet Machine) and removal of sludge/silt/liquid/mud and sand (in foul position) etc out side the MOD land including testing of drains by filling the pipes with water complete all as specified and as directed.
Dewatering of soak well by means mechanically 2.4 mtr dia and 6 mtr depth complete all as specified and as directed.
Desludging of septic tanks (200 users) mechanically by removing all loose materials and sludge and cleaning the same with water by Jet Machine and removal of sludge/silt/liquid/mud and sand (in foul position) etc outside the MOD land complete all as specified and as directed.
All as per item No. 124 here-in-before but septic tanks (100 users).
All as per item No. 124 here-in-before but septic tanks (50 users).
All as per item No. 124 here-in-before but septic tanks (25 users).
Demolition and breaking up drain pipes of dia 200mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and as directed.
Demolition and breaking up drain pipes of dia 150mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and as directed.
M&L for cutting into existing manholes for connecting new drains , making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching so required 150 m dia complete all as specified and as directed.
Excavating in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation etc for for shafts, wells cesspits, manholes, piers holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in loose/soft soil etc complete all as specified and as directed.
Excavation over areas n.exc 1.50 m deep and getting out in soft/loose soil complete all as specified and as directed.
Excavation over areas exc 1.5 mtr but n exc 3 mtr deep and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick with soil etc complete all as specified and as directed.
Removing excavated soil to a distance exc 250 m but n.exc 500 m and depositing where directed complete all as specified and as directed.
M&L for reinforced concrete pipes 200 mm dia, class NP-2, laid and jointed complete with collars complete all as specified and as directed.
M&L for reinforced concrete pipes 150 mm dia, class NP-2, laid and jointed complete with collars complete all as specified and as directed.
M&L for cement concrete 1:3:6 type C-2 for 200 mm dia in bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested etc complete all as specified and as directed.
M&L for cement concrete 1:3:6 type C-2 for 150 mm dia in bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested etc complete all as specified and as directed.
M&L for brickwork with sub class ‘B’ bricks in one brick thick honey comb walling, built in cement mortar (1:4) complete all as specified and as directed.
M&L for plain cement concrete type D-2 1:4:8 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete, sub base complete all as specified and as directed.
M&L for providing reinforced cement concrete (nominal mix) type A1 (1:1.5:3) using 20 mm graded stone aggregates as in slabs supported on walls,beams and columns in floors,roofs, complete all as specified and as directed.
M&L for providing reinforced cement concrete (nominal mix) type A1 1:1.5:3 (20 mm graded stone aggregates) as in beams, cantilever, lintels over 1.5m span etc complete all as specified and as directed.
Use and waste formwork to soffits of suspended slabs such as roof slabs, floorslabs, landings and similar work not exceeding 200 mm thick rough finished in flat surface complete all as specified and as directed.
Use and waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed.
M&L for mild steel TMT bars 10mm dia and over. Cut to length, bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for mild steel TMT bars 5 mm dia and over, upto and including 10 mm dia as in stirrups, cut to length, bent to shape required including cranking, bending for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and as directed
S&F SFRC manhole cover 75 mm thick factory made with plain surface as per requirement including 75 X1.5 mm flat iron frame all around the cover complete all as specified and as directed.
S&F in repair 75mm PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and as directed.
S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 75mm bore complete all as specified and as directed.
S&F in repair PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 110 mm bore complete all as specified and as directed.
S&F in repair 110mm dia PVC (SWR) pipe and single socketed in any length with rubber ring joint fixed to wall complete all as specified and as directed.
S&F in repair PVC (SWR) bends any radius 110 mm bore complete all as specified and as directed.
S&F in repair PVC (SWR) junction single, (single T) equal or unequal 110mm bore with access door complete all as specified and as directed.
S&F in repair PVC (SWR) bends any radius 75mm bore complete all as specified and as directed.
S&F in repair steel rolling shutter of thickness 1.25 mm without ball bearing as specified including top cover , anchoring rod , hasp and staple and one shop coat of primer erected in position, gear operated type with bevel gear box and crank handle complete all as specified and as directed.
M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregates) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified and as directed.
M&L for cement concrete type C-1 1:3:6 (using 20 mm graded stone aggregate) as in surface channel and drains etc complete all as specified and as directed.
M&L for 100 mm thick cement concrete (1:2:4) type B-1 with using (20 mm graded crushed stone aggregates) as in Hardstanding including spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green etc complete all as specified and as directed.
M&L for Forming contraction (Dummy) joints 65 mm deep x 10mm wide, filled with sealing compound grade 'A' complete all as specified and as directed.
M&L for loose filling with aggregates (broken bricks) of gauge 80 to 150 mm in soakage pits, soakage wells complete all as specified and as directed.
Taking down carefully copper/aluminium point wiring (light, Fan, Socket or power) fitting such as switches, ceiling roses, pendents, regulators, sockets etc complete removing material to store for keeping in safe custody for reuse or taking in schedule of credit and making good disturbed surfaces of walls, floors etc complete all as specified as directed.
Dismantling and taking down fluorescent tube light SI-ngle/double of any wattage or SI-ze street light fittings for repair or replacement of burnt/worn out accessories or carrying to MES store for reuse or taking in schedule of credit complete all as specified as directed.
Taking down unserviceable sub main wiring of any type/SI-ze including wires, conduits,bends,tees/battens etc complete all as specified as directed.
Taking down unserviceable MCB, MCCB DB's/AC's box with MCB/MCCB to depoSI-t in store for keeping in safe custody for reuse or taking in schedule of credit of any SI-ze/rating complete all as specified as directed.
M&L for point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of SI-ze 1.5 sqmm drawn through in and including concealed PVC conduit size of not less than 20mm concecled in wall / surface including provn of pressed steel terminal box of suitable size with 3mm thick plastic laminated sheet cover / modular white cover plate with frame as required module & modular metal flush box as required module for mounting switch, socket and fan regulator along with earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded copper conductor of SI-ze 1.5 sqmm and making good, disturb surface as it is, complete all as specified as directed. for the following. Note :- Colour coding of cable should be Phase- Red, Neutral- Black and Earth- Green
One light point controlled by one,one way switch complete all as specified as directed.
One ceiling fan/exhaust fan/Air ciculator /bell point controlled by one way switch complete all as specified as directed.
One light point controlled by 2, 2 way switch complete all as specified as directed.
Socket 3 pin 5 Amps on the same board, complete all as specified as directed.
Socket 3 pin 5 Amps on independent board , complete all as specified and as directed.
M&L for point wiring with two runs of FRLS PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of SI-ze 2.5 sqmm drawn through in and including concealed PVC conduit SI-ze of not less than 20mm concecled in wall / surface including provn of pressed steel terminal box of suitable SI-ze with 3mm thick plastic laminated sheet cover / modular white cover plate with frame as required module & modular metal flush box as required module for mounting switch, socket and fan regulator along with earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded copper conductor of SI-ze 2.5 sqmm and making good, disturb surface as it is, complete all as specified as directed. Note :- Colour coding of cable should be Phase- Red, Neutral- Black and Earth- Green
M&L in replacement for sub main wiring with two SI-ngle core 2.5sqmm stranded copper conductor PVC insulated and unsheathed cable ISI- marked in 25 mm dia, medium grade, PVC conduit concealed in wall for sub main connection including 2.5 Sqmm PVC insulated unsheathed copper conductor ISI- marked as earth wire complete all as specified as directed.
All as per item No 168 herein befoe but submain wiring with 2x4Sqmm and 1x4 Sqmm as earth wire complete all as specified as directed.
All as per item No 168 herein befoe but submain wiring with 2x6Sqmm and 1x6 Sqmm as earth wire complete all as specified as directed.
All as per item No 168 herein befoe but submain wiring with 2x10Sqmm and 1x10 Sqmm as earth wire complete all as specified as directed.
S&F for switch socket outlet 5 Amps, 5 pin flush type, 240 volts. with polycarbonate body complete all as specified as directed.
S&F for switch socket out let, 6 pin 5/15 Amps multi purpose 2 in 1 flush type, 230 volts with polycarbonate body complete all as specified as directed.
S&F for switch piano flush type SI-ngle pole one way 5 Amps 240 volts with polycarbonate body complete all as specified as directed.
S&F switch piano flush type SI-ngle pole two way 15 Amps 240 volts with polycarbonate body complete all as specified as directed.
S&F bell push flush type SI-ngle pole one way 5 Amps 240 volts with polycarbonate body complete all as specified and as directed.
S&F bell electric heavy duty Ding Dong type 230 volts SI-ngle pole complete all as specified and as directed.
S&F For ceiling fan regulator stepped electronic type 300 watt rating, 230 volts with polycarbonate body complete all as specified as directed.
S&F Modular switch 1 way 6A, 1 module complete all as specified as directed.
S&F Modular switch 1 way 16A, 1 module complete all as specified as directed.
S&F Modular switch 2 way 6A, 1 module complete all as specified as directed.
S&F for modular socket outlet 6A 2/3pin combined 2 module complete all as specified as directed.
S&F for modular socket 6A /16A 2/3pin combined 2 module complete all as specified as directed.
S&F Modular fan step regulator, 120W 2 module complete all as specified as directed.
M&L for ceiling rose 3phase/PVC polycarbonate isolated body complete all as specified and directed
S&F modular bell push 6A, 1 module complete all as specified as directed.
S&F LED decorative Garden light for 360 degree indirect light IP-65 grade of protection ISI mark with high power LED of 10 watt with resistant to impact and corrison.Glare free and better uniformity warm yellow including fixing material PCC 1:2:3 B-2 , exca. and earth work after taking down old existing garden light complete all as specified as directed.
S&F in replaceent of MCB DB sheet enclosure SI-ngle pole and neutral 240V with 200 Amp suitable SI-ze plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete confirming to IP 43 with enclosure blank plates for unused way suitable for 2 way complete all as specified and as directed.
S&F in replaceent of MCB DB sheet enclosure SI-ngle pole and neutral 240V with 200 Amp suitable SI-ze plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated Acrylic double door complete confirming to IP 43 with enclosure blank plates for unused way suitable for 12 way complete all as specified as directed.
S&F in replaceent of MCB DB sheet enclosure load line Vertical Triple pole and neutral 415V with 200 Amp suitable SI-ze plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated Acrylic double door complete confirming to IP 43 with enclosure blank plates for unused way suitable for 12 way complete all as specified as directed.
S&F MCCB DB TPN 4 Way vertical tupe factory made IP 43 protection class metal double door with Shrouded Neutral Bar & Pan assembly with connecting link complete including provision for one MCCB upto 125A after dismantling old one complete all as specified as directed.
S&F MCCB 125 Amp 16 Ka for fixing in DB complete all as specified as directed.
S&F in replacement ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with BEE star rated with brushless direct current motor complete all as specified as directed.
S&F in replacement electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified as directed.
S&F LED building light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection and L shape GI pipe bracket of 40 mm dia. complete all as specified as directed.
S&F MCB C curve SPN 40 to 63 Amps 240/415 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete all as specified as directed.
S&F MCB B curve SP 5 to 40 Amps 240/415 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete all as specified as directed.
S&F LED lights fitting 1x 22W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable SI-ze from ceiling rose complete all as specified as directed.
S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified as directed.
S & F Lamp holder insulated body with back plate for batten fittings.with polycarbonate body complete all as specified and as directed.
S&F in replacement of sheet metal enclosure with socket plug top and MCB single pole and neutral with two pin and earth plug with one SP MCB 20 Amp 240 volt complete all as specified and as directed.
M&L for earthing complete with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI wire 4 mm Dia as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 uSI-ng 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 uSI-ng 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including proviSI-on 20 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified as directed. NOTE: (i) The concrete pit shall be PCC 1:3:6 type C-140 mm thick pre cast cover slab of RCC(1:2:4) type B-1 uSI-ng 20 mm graded stone aggregate reinforced with 8 mm TMT bars @ 10 cm C/C on both SI-des with suitable cast iron handle shall be provided in lieu of cost iron cover shown in the electrical plate No.3 of MES SSR Part -1 (ii) item includes the cost of 7.5 m GI pipe for protection of GI wire. (iii) PCC pits extra cost of addtional length of watering pipe,bends elbows etc.shall be deemed to be included in the quioted rate. (iv) Item includes the cost of 7.5 mtr length Galvised wire 4 mm dia.
Shiv Shakti Builders
MOHIT ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .