Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.6 CrAccepted-AOC DAM ROAD TALWARA TOWNSHIP DISTT HOSHIARPUR PB | ₹19.6 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹21.5 CrRejected-AOC | ₹21.5 Cr | L2 | Rejected-AOC higher bid |
| 3 | L3₹22.0 CrRejected-AOC | ₹22.0 Cr | L3 | Rejected-AOC higher bid |
| 4 | L4₹23.1 CrRejected-AOC | ₹23.1 Cr | L4 | Rejected-AOC higher bid |
Tender Value
₹19.8 Cr
EMD Value
₹20.1 L
Closing Date
21 Apr 2023, 11:00 amClosed
Executive Engineer
Executive Engineer Jal Shakti Division Suni
Augmentation of WSS Sunni in NAC Sunni Tehsil Suni Distt Shimla HP Under AMRUT 2.0
2023_HPIPH_72184_1
SNN-SML-03-740-Tender/23-92-97 dt 11/04/23
Open Tender
Civil Works - Water Works
730 days
Suni
Please refer Tender documents.
12 documents required · 12 mandatory
₹2,500
EE JSV Suni
₹20.1 L
Shimla
24 Jul 2023
12 Apr 2023
21 Apr 2023
12 Apr 2023
21 Apr 2023
12 Apr 2023
12 Apr 2023 - 21 Apr 2023
18 Apr 2023
Amount
Description of items
Cutting in Earth work and disposal of excavated earth upto a lead of 20 meters . Spade Work , Pick Work , & Jumper Work
Excavation in foundation trenches etc.in earth work upto all depths in all kinds of soil such as pick work,jumper work,blasting and chiselling soft/hard rocks where blasting is prohibited in all leads and lifts including trimming and dressing of side levelling of bed to correct grade and returning the stacked soil in trenches in 15cm.layers by ramming and watrering and then disposing of all surplus excavated soil as directed in all leads and lifts and soring strutting/timbering and dewatering where ever required including restoration of un metalled/metalled paved surfaces to its original conditions including caution boards in all respect and to the entire satisfaction of the Engineer-in-Charge.
For Site Development , Tanks , Pump House Etc.
For Pipe Line
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Providing and laying cement concrete 1:2:4 (1cement :2 sand:4 graded crushed stone aggregate and 20mm nominal size) and curing complete excluding the cost of form work in foundation and plinth in all leads and lifts.
Fo Fencing Post
Suspended floors roofs, landings and shelves and their supports, balconies, beams, girders, bressumers and cantilever up to floor two levels.
Column
Plinth & Foundation
Walls (any thickness but not less than 0.1 m thickness) attached pilasters, buttresses, plinth and string courses etc. from top of foundation level up to floor two level.
Providing and laying cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in:-
Foundation and Plinth.
Providing and laying cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of form work in:-
Foundation and Plinth.
Brick Work using common burnt clay building bricks in foundation and plinth in cement mortar 1:4 (1 cement : 4 sand) First class bricks.
1.20 mtr. High fencing with 1.65 mtr. M.S. Angle iron post of size 50 x50x 5 mm (min) including cutting & hosting and welding including painting complete in all respect
1.20 mtr. High fencing with 1.65 mtr. M.S. Angle iron post of size 50 x50x 5 mm (min) 2.50 mtr. Center to center with 6 horizonal lines Galvanised steel barbed wire (IS-278-1962 Type-I) weighing 9.38 Kg./-per 100 mtr.(Minium) strained and fixed to posts with 6.1 stples linclulding with painting of M.S. angle iron comploete. ( Angle 50x50x5 mmm)
Providing and laying cement concrete 1:5:10 (1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) with 15 % plum and curing complete excluding cost of form in retaining Walls / breast walls, the size of plums shall usually be 150 mm to 300 mm as per H.P.P.W.D. Specification
Providing form work with steel plates 3.15 mm thick welded with angle iron in frames 30x30x5 mm so as to give fair finish i/c centring shuttering strutting and propping etc. with woodan batton and ballies, ht. of propping and centring below supporting floor to ceiling not exceeding 4 mtrs. and removal of the same for insitu-reinfornced concrete work in
Vertical surfaces such as walls ( any thickness ) partitions and the like including attached pilasters , buttresses, plinth and string courses and the like .
Flat surfaces such as soffits and suspended floors, roofs , landing and the like:-
Providing form work of ordinary timber planking's so as to give a fair finish including centering, shuttering, propping etc. height of propping & centring below supporting floor to ceiling & removal of the same for-in-situ reinforced concrete & concrete work in arches exceeding 6 mtrs. span (dome) as per direction & to the entire satisfaction of Er.-in-Charge.
Providing & Fixing of Hollow Pipe Gate with locking arrangement complete including Steel primering Coat
Main Gate (Weight :- 256.07 Kg)
Side Entrance Gate (Weight :- 27.13 Kg)
Painting two costs (excluding priming cost on new steel and other metal surfaces eith enamel paint brushin to give an even shade including cleaning the surface of all dirt,dust and other foregin matters :-- Enamel paint other than white.
Writing letters or figures on any surfaces with readymixed paint (stops, comas, hyphens and the like not to be measured and paid separately) Block letters/figures, Roman letters/figures, Italic letters/figures. Text Height 15 cm
Providing mild steel/tor Steel reinforcement for R.C.C work including bending , binding and placing in position complete up to floor two level.
Providing and laying cement concrete 1:4:8 (1 cement : 4 sand : 8 graded stone aggregate 40 mm nominal size) and curing complete excluding cost of centering & shuttering in foundation and plinth.
R/R stone masonry/ Polygonal rubble masonry (uncoursed/brought to courses) with hard stone of approved quality in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 sand : 12 graded stone aggregate 20 mm nominal size) at plinth level in cement mortar 1:6 (1Cement : 6 Sand).
Providing and laying cement concrete 1:1.5:3 ( 1 cement : 1.5 sand : 3 graded stone aggregate 20mm nominal size) and curing complete excluding cost of form work & reinforcement for reinforced concrete work in:-
Foundation and Plinth.
Walls (any thickness but not less than 0.1 m thickness) attached pilasters, buttresses, plinth and string courses etc. from top of foundation level up to floor two level.
Column
Suspended floors roofs, landings and shelves and their supports, balconies, beams, girders, bressumers and cantilever up to floor two levels.
Half brick masonry in common burnt clay building bricks in : cement mortar 1:4 (1 cement : 4 sand) first class brick in super-structure.
Supplying and fixing of rolling shutters of approved make made of 80mmX1.25mm M.S lathes inter locked together through their entire length and jointed together at the end by end locks sepecially desigened pipe shaft with bracket side guides and arrengements for inside and outside locking with push pull complete but excluding the cost ot top cover and spring. including all fiting Complete.
Providing wood work in frames of doors, windows, clearstory, windows and other frames wrought, framed and fixed in position: 2nd class deodar wood
Providing and fixing panelled glazed or panelled and glazed shutters for doors windows & clearestory windows i/c black enamelled iron butt hinges with necessary screws: 40 mm thick 2nd class deodar wood
Providing and fixing Wire gauge shutters using galvanized M.S Wire gauge of I.S Gauge designation 85 G with wire of dia 0.56 m.m for door windows and clearstory windows i/c black enamelled iron butt hinges with necessary screws: 40 m.m thick 2nd class deodar wood.
Providing and fixing MS grills of required pattern in wooden frames of windows etc. with MS flats, square or rounded bars with round headed bolts and nuts or by screws.
20 mm cement plaster in single coat on the rough side of stone masonry for interior plastering up to floor to level i/c arises, internal rounded angles, chamfers and/or rounded angles not exceeding 80 mm in girth and finished even and smooth in c:m 1:6 (1 cement : 6 sand).
15 mm cement plaster in single coat on the rough side of brick/concrete/stone walls for interior plastering up to floor to level i/c arises, internal rounded angles, chamfers and/or rounded angles not exceeding 80 mm in girth and finished even and smooth in c:m 1:6 (1 cement : 6 sand).
Applying priming coat over new wood and wood based surface after and including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign sand papering and knotting. Ready mixed paint brushing with white wood primer pink.
Painting two coats ( Excluding priming coat) on new wood and wood based surface with ready mixed paint, brushing to give an even shade including cleaning oil, grease, dirt, dust and other foreign matter sand papering and stopping:- Ready mixed paint other than white.
Applying Birla White wall care Putty over plaster surface after throughly brushing the surface free from mortar drops , dust , loose , materails and other to give matters sand parpered smooth to give final matter finish to the surface complete.
Providing 40X3 Flat iron hold fast 40cm long i/c fixing to frame with 10m.m dia bolts nut and wooden pugs and embedded in cement conc. Block 30x10x15 (1 cement: 3 sand:6 graded stone aggregate 20mm nominal size).
P/F anodized aluminium sliding door bolts and nuts screws etc. complete
P/F anodized aluminium tower bolt anodized transparent or dyed to required shade and colour with screws etc. complete
P/F anodized aluminium Handles anodized transparent or dyed to required shade and colour with screws etc. complete.
P/F Oxidized M.S. hooks and eyes
Boulder filling dry hand packed tightly under floors.
Disposal incuding loading unloading and staking of surplus excavated soil/material with in a lead of 2 km by M.T. & 500 mtrs Head Load at the disposal site.
40 mm thick cement conc. Flooring 1:2:4 ( 1 cement : 2 sand : 4 graded stone agg. 20 m.m nominal size) laid in one layer finished with a floating coat of neat cement.
Providing Plinth Protection 50 mm thick in cement concrete1:3:6 (1 cement: 3 sand:6 graded stone aggregate 20mm nominal size) including finishing the top surface of concrete smooth.
White Glazed tiles 6 mm thick in flooring , treads of steps and landing laid on a bed of 12 mm thick cement mortar 1:3 finished with flush pointing in white cement.
Relaying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Providing & Fixing of Nut Bolts 20mm Dia 450 mm Long
Providing & Fixing of MS Plate 10 mm thick including cutting , hosting & Fixing in position
Providing & Fixing of ISMB ,ISMC for Truss including cutting , hosting & Fixing in position & Apply a priming Coat of Red paint
Providing and fixing stand post of angle iron 50x50x5mm
Providing prepex sheet roofing fixed with G.I. or J and L hooks , bolts and nuts 8mm Dia metre with Bitumen and G.I. limpet washers filled with white lead complete excluding cost of purlins , rafter and trusses. 2 mm thick sheet
Manfacturing MS Manhole Cover 600x450mm with Frame of MS Angle 50x50x6mm and cover of black sheet 2.00mm thick complete with angle frames, flates etc including welding with locking arrangemets(Locks) (excluding Cement Concrete)
Providing in R.C.C work smooth finishing of the exposed surfaces with cement mortar 1 : 3
Steel Work in single section including cutting , hoisting , fixing in position and applying a priming coat of lead paint .
Providing and fixing Sand cast Iron/Cast Iron spun spigot and sacketed soil waste and ventilating pipe (lead lanlked jointe to be measured & paid for seprately)-100 mm dia
Laying & Jopinting in trenches to be leveled to grades,IS marked GI pipes GMS (Medium grade) of following diameters conforming to IS 1239-1991 ( PartII ) latest with up to date amendments ) having minimum wall thickness as for class of pipe specified below jointed with pipe conforming to tables as specified below of BIS 6392-1971 ( Lautest with up to date amendments ) butt. welded at Both ends according to relevant BISstandards & detailed specifications complete in all respect of technical specifications as per site conditions including flushingt,cleaning & hydraulic testing complete to the best satisfaction of Engineer in charge.
150 mm Dia
125 mm Dia
100 mm Dia
80 mm Dia
Laying & Jointing in trenches, GMS Tubes (Light Grade), Tube fittings (earth work in trenches to be measured and paid for separately).
15 mm Dia
20 mm Dia
25 mm Dia
32 mm Dia
100 mm Dia
150 mm Dia
Providing and Fixing CI Sluice Valve with wheel.
150 mm Dia
125 mm Dia
100 mm Dia
80 mm Dia
250 mm Dia With Flange ( Table No. 5)
Providing and Fixing Brass Full way wheel valve with wheel.
15 mm Dia
20 mm Dia
25 mm Dia
32 mm Dia
Making connection of galvanised steel distribution branch with galvanised mild steel main 20mm to 40mm nominal bore by providing and fixing tee including cutting and threading the pipes complete.
Making connection of galvanised steel distribution branch with galvanised mild steel main 50mm to 100mm nominal bore by providing and fixing tee including cutting and threading the pipes complete.
Providing & Fixing of Steel Chamber 600 X 600 x450 mm with locking arrangements make by 1 mm thick MS Sheet 40 X 40 x 5 mm thick Angle welded fitting complete including applying a priming coat of red lead Paint.
Providing and Fixing FIRE Hydrant valve of Leader 80 mm Dia.
Providing & Fixing of Water Meter for house water connection .
Rising Main
Providing, laying, testing & commissioning at site in trenches bevelled ended BIS marked API confirming to ISO-3183-2007 relevent codes & specification its equivalent latest with up to date ammendments of following dia with steel grade API having wall thickness & per Rmt weight as mentioned below & capable of withstanding required test pressure as prescribed in BIS code, in random lengths of 5.5 to 6.5 mtr. The pipe's ends shall be bevelled suitable for butt welding, including the cost of jointing with butt welding confirming to IS 816-1969 or latest as applicable ends with up to date ammendments (leak proof) in three layers at site of work with welding rods of standard make & all allied accessories whatever required for welding at site, tail pieces, tees, bends & other specials manufactured from parent pipes as applicable to the particular reach & of approved specification as per site conditions. and cutting of pipes wherever required as per site requirement i/c carriage in all leads & lifts and as directed by Engineer-Incharge. The pipe shall have's zinc coating inside & outside confirming to IS-4736-1986 or latest with up to date ammendments & shall be engraved with API X-52, API X-60 . The laying shall confirm to BIS 5822-1970 or latest with up to date ammendments to the entire satisfaction of Engineer-Incharge (Earth work & cost of MS flanges after 100 meter length shall be measured & paid for seperately).
Sr.No. RD Length Dia Class Thick
B/Stage 0 - 90 90 250 mm L 210 4.80mm
1st Stage 0 - 300 300 250 mm API X 60 4.80mm
300 - 900 600 250 mm API X 56 4.80 mm
900 - 1500 600 250 mm L 210 4.80mm
For Tanks
250 mm Da API X 60 , 4.80 mm Thick
Providing , Welding and Fixing of M.S. Flanges ISI marked conforming to IS : 6392-1971 capable of with standing the test pressure of 1.60 N/mm2 welded on both sides with the pipe complete with nut & 3 mm thcik ferrado gasket . The welding is conforming to IS : 3183-1986. including hydraulic testing at site and painting with anticorreshive pasint in side and outside confirming to relevant specfication . the work shell be done including all leads and lifts as per entire satisfaction of Engineer - in - Charge.
Sr.No. RD Length Dia Class Table
B/Stage 0 - 90 90 250 mm L 210 5
1st Stage 0 - 600 600 250 mm API X 60 28
600 - 900 600 250 mm API X 56 23
Providing & Fixing of Kiloskar / Leader/ KSB / Pelicon/Fouress make of cast steel Double Flanged automated / self actuated sluice Valve having size one size higher than the nominal delivery size of pump and capable of withstanding nominal seat pressure & confroming to API X 60 standards with up to date ammendments for delivery line of pump (including one No. for common header).) NOTE :- the sluice valve shell conform to BIS 780-1984 latest with up to date ammendments how ever , if the seat prusser exceeds the limits prescribe in BIS 780 then the Sluice valves shall be of cast steel conforming to class ASA 150 (Seat prusser 21 kg /Cm2 ) as per BS 1414 (API 60 ) compatible with the automations system , including all lead & lift & as per entire satisfaction of Engineer - in - Charge.
Providing & fixing Cast Steel Double acting air valves working pressure 11.22Kg/cm2with isolating cock, hexnipple for air vent, abonite & rubble ball for large & small orifice resp. mounted on moulded rubber dexin with forged bronze or high tensile extruded brass rod spindle, flange drilled as per IS: 1538 : 1967 table no. 4 & 5 tested complete with bolts and nuts etc. including all leads and lifts and as per entire satisfaction of Engineer - in - charge
80 mm Dia
Providing & fixing Cast Iron Double Flanged automated / self actuated Reflux Valve for rising main
Pumping Machinery
Booster Stage
Supply of submersible pumping set of reputed make such as KSB/CALAMA/SU/johnston conforming to latest relevent BIS code to be placed in 125mm drill bore.The pump should be fitted with free flow impellers of bronze/suitable alloy as per BIS5659-1970 latest suitable for raw water having greased packed bearings & shaft with wound stator on motor side & with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to a submersible squirrel cage electric induction motor of Kirloskar/NGEF/Jyoti Crompton make conforming to relevent BIS code latest with up to date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber & grease packed lubricated bearing & provided with stainless steel thrust bearing plate to with stand non vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump set should include water level guard, errection clamps, cable clips & depth gauge etc. suitable for operation on data given below:-
(I) Discharge (Q) 55.58 LPS (55.58 LPS for each pump set ) (ii) Total Dynamic Head: 49.16Meters. (a) LWL in sump well(h) : Meters.(b)_ Shaft level :- 635.00. Meters. © Level at discharge point : 680 Meters.(d) Suction lift :- 3 Meters. (e) Residual head:- 3.00 Meters. (f) Static head:- 45.00 Meters. (iii) Rising main (a) Length. 90 Meters. (b) Dia :- 300 mm. (iv) Pumping hours. 16 hours. (v) Altitude of Installation above MSL - Meters. (vi) Characteristics of water (a) Temperature oC (b) Abient Temperature oC © Turbidity Clear water JTU (d) Alkalanity Mg/CA CO3 (e) Size of the solids. Mm. (f) Other
. (b) Motors I) Make ii) Model iii) Motor rating (KW). iv) Speed.(ii)Discharge(Q ) (iii)BHP absorbed (iv)Efficiency(n) (v) NPSH(K) (v) Insulation ©
(c.) Coupling ]
(d) Base Plate ]
Providing ICTP Main switch with HRC fuses of Kilburn/L&T/Siemens/Crompton/ Standard/Havells make and having Capacity 30% extra of the Operational rating as per IS:4064-1978 with upto date ammendments immediately after the power meter of HPSEB all internal connections:ICTP SWITCHES ((i) Make (ii) Type (iii) Capacity
Providing MS .sheet,steel fabricated floor mounted closed(Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm,duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories withPanel/Switch Board (I) Drawing (ii) Layout plan
A.C.B./Oil circuit breaker of Kilburn/L&T/MEI/GEC make & of suitable capacity on incoming feeder with or without oil filling as the case may be with neutral linked under voltageinitial releases as per IS: 2516-1985 with upto date ammendments with A.C.B/O.C.B (I) Make (ii) Type (iii) Range iv) Capacity
Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/ GEC) as per 2516-1977 with upto date ammendment and of suitable range which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring conditionof the circuit breaker for over current protection. The circuit shouldshould also be fitted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end.E.L.C.B.I)Makeii) Type(iii) Range…
The voltage monitor relay three phase with all protection and usual indicator and electric siren against single phasing low voltage,high voltagereverse phasing,over loading and phase voltage difference as per IS:3842(latest edition).VOLTAGE MONITO RRELAY. (I) Make (ii)Type (iii) Range
Power factor meter of standard make as per relevant IS code with uptoPower factor meter of standard make as per relevant IS code with uptoPower factor meter of standard make as per relevant IS code with upto POWER FACTORMETER (I)Type (ii) Make
Frequency meter of standard make as per relevant IS code with upto dateammendments of suitable rating.FREQUENCY METER ( i ) Type (ii) Make (iii)Range.
Bus bar chamber having three bars of suitablerating for full length equal to the width of the board for three liverating of full length for neutral phase as per IS:8084-1976 and IS:11353-1985 read with BIS 5578-1985 with upto date ammendments BUS BAR CHAMBER (I) Type (ii) Make (iii_ Rating…
ICTP switches with HRC fuses of L&T/Crompton/Kilburn/Siemens/standard/Havells make and of suitable capacity as per IS 4064-1978 with upto dateammendments.ICTP SWITCHES(I) Type(ii) Make(iii)_Capacity
Three phase Indicator lamps complete with toggle switches for individual motors as per IS 3452(P-I&II) with upto date ammendments.THREE PHASEINDICATOR (I) Type (ii) Make (iii) Capacity
Capacitor of Mechneil/Bhel/GEC/ L&T/ make as per IS:2834-1986with upto date ammendments to raise the power factor at site to0.95 for direct connections to induction motor individually of requiredKVA rating according to HP offered including cablesas per relevant ISI code(of Siemens/Glocter/IEC make) from bus barchamber to capacitor and also including ICTP switches of appropriaterange as per IS: 4064-1978 with upto date ammendments.CAPACITOR (I)Type (ii) Make (iii) Range…
Providing suitable Oil immersed star delta/direct on line /auto -tran former/starter rotor starter of MEI/Kilburn/Jyoti/L&T/Siemens make as per IS 8544-1979 with upto date ammendments for squirrel cage/slip ring motor mounted on pannel board with magnetic type overload releaseand dashpot, time lag,under voltage release with or without initialoil filling as the case may be with single phase preventor as perIS 1248(P-V)- 1983 with upto date ammendments.STARTER (I) Type (ii) MakeSINGLE
PHASEPREVENTOR (I) Type ii) Make
Providing Hour run meter of recommended make of suitable capacity as per IS:722(Latest edition).HOUR RUN METER(I)Type(ii) Make(iii)Capacity
Prov. Antivibration pads under the pumps and motors of suitable size for theabove pumping machinery as per IS; 6337-1971 Antivibration Pad; 1) Size (ii) Make iii)Material
Prov…………..volts battery with battery charger for tripping of motor control.i)Size .ii)Make :iii)Material.
Prov. Cast iron flanged/screw type foot valves with strainer as per IS: 4098-1986 with upto date ammendments of Kirloskar/Mechneil/Kilburn / GLED/Fouress make 150 mm dia .FOOT VALVE :I) Make :ii)Class iii)Test working head .iv) Material
Providing double flanged cast Steel sluice valve of Class ...........Leader/Bhel/Kirloskar/Kilburn/GLED/Fouress make and of 300 mm dia. for the suction Pipe and capable of with standing the normal seat pressure and as per BS-1414 with upto date ammendments.SLUICE VALVE (I)Make (ii) Class (iii)Seat pressure (iv) Material
Providing double flanged cast Steel reflux valve of Class ........ Leader/Bhel/Kirloskar/Kilburn/GLED/Fouress make and of 300 mm dia. for the delivery line of pump and capable of with standing the normal seat pressure and as per BS-1414 with upto dateammendments.REFLUX VALVE(I)Make(ii) Class (iii)Seat pressure(iv) Material
Providing double flanged Cast Steel Refluxvalve of Class ...........Leader/Bhel/Kirloskar/Kilburn/GLED/Fouress/Kartar make and of 250 mm dia having bye pass arrangement for Rising Main and capable of with standing normal seat pressure as per BS:1868 (P.I) with upto date ammendments.REFLUX VALVE(I) Make(ii) Class (iii)Seat pressure(iv) Material.
Providing 250mm dia circular dia pressure gauge of Fiebing/Bourden Prega/precision make complete with all accessories such as stop cock,copper tubing etc. as per IS 3624-1987 with upto date ammendments.PRESSURE GAUGE (I)Make (ii)Range
Providing 250mm dia circular dia vaccume gauge of Fiebing/ Bourden/Prega/Precision make complete with all accessories such as stop cock,coppertubing etc. as per IS 3624-1987 with upto date ammendments VACCUME GAUGE (I)Make (ii)Range:
Prov.discharge meter standard make to be tiked on the rising main near thestorage tank as per the directions of the Engineer-in-charge as per IS-2373-1981 with upto date ammendments.Discharge Mete r i)Make :ii)Type :iii) Range
Installation of all the items appearing at Serial No. 64 to 88 as per the systematic drawing attached with the tender documents(Drg. No.1).
Providing and fixing double flanged MS piping work layout tobe approved by the Engineer-in-Charge for suction and deliverypipes suitable to pump(s) offered and common header as per thethe rising main respectively complete with all specials such as bends,tees reducers/increasers with companion flanges matching with therelevant specifications of the accessores as indicated in thedrawing No 2 including rubber/asbestos gasket of minimum 3mmthickness as per IS 2712-1979 and required number of nuts and volts as per IS 1364-1983. The pipes shall be as per relevant IS codeand to withstand 1.5 times total head stipulated under item No.1he size of the various components to be as under:- (I) Suction pipe… 250 mm dia (ii)Delivery pipe… 250 mm dia. (iii)Common Header 250 mm dia. and will extended upto 5 mtrs from the outer wall of the pump SUCTION PIPE (I)Make(ii)Grade (iii)Thickness (iv) Pressure rating.
DELIVERY PIPE AND COMMON HEADER .(materia l. (ii)Grade (iii)Thickness (iv) Pressure rating.
Providing and laying copper PVC insulated armoured powercable(one cable carrying all the three phases)of suitable sizeand capacity to and all other electrical equipments as per IS:1554(P-I)1988 or latest with upto date ammendments of Siemens//Gloster/ JEC/ICC/EICO National/Grandlay make including all otheraccessores such as thimbles, flexible,pipes solder,nuts and bolts,accessores such as thimbles, flexible,pipes solder,nuts and bolts,ARMOURED POWERCABLE(A)Motor side(fromswitch to starter andstarter to motor.)(I)Size (ii)Make(iii)Type(iv)Capacity(v) Core.(B)SUPPLY SIDE(FROM METER OFHPSEB TO BUS BAR AND SWITCH) (I) Size(ii) Make(iii)Type(iv) Capacity(iv)Core.
Providing and fixing double loop earthing with copper plate600mmx600mmx3mm thick electrode complete with material suchas thimbles, nuts and bolts,charcoal and common salt,25mmx3mm copper strips/as per IS: 3043-1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc,.complete in all respect.
1st Stage
Providing horizontal spindle horizontal/radial split casing/end section (back pull out arragement) single/double/multistages centrifugal pump or combination of pumps, in series/parallel of recommended make such as Mather and Platt/KSB//Becon weir/Kirloskar/ BE/Jyoti WASP/ASPEE as per BIS-1520-1980 with upto date ammendments, read with IS -9137-1978 or latest edition suitable for lifting Clear water for under mentioned characterstics with bronze impellers/priming funnels casing ring and shaft sleaves of bronze, shaft of steel grade- with cast iron casing coupled directly through a flexible coupling on a common C.I/Cast steel base plate(base plate to be from the manufacturers of the pumping unit only) to Slip/Ring/ Squarrel cage screen protected drip proof induction motor of standard make such as Kiloksar/Crompton/Bhel/NGEF/ GEC/SIEMEN/ JAYOTI/ABB suitable for operation on 415(+)/-5% volts, 50 cycles/second, 3 phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the opeation range of (+)10% and(-) 15 % of the duty point head. The motor should be as per IS: 325-1978 with upto date ammendments read with IS 900-1972. It should include cost of bearing nuts,bolts and pointing etc. and should meet the following requirements:- (2 Working + 1 Standbye) Scheme :-Shakrori Side 1) Discharge (Q) LPS- 21.96, LWL in sump well (h)-650.00 mtr, Suction lift 3.00 mtr, Residual Head-03 mtrs., Static Head- 400.00 mtrs. , Total Head - 412.21 Rising main Length- 1500.00 mtrs., Dia- 250 mm, Pumping hours- 16, Altitude of Installation above MSL:-- mtrs., Characterstic of Water Temperature 0C, Abient Temp 0C, Turbidity Clear water JTU, Alkalanity Mg/CA CO3, Size of the solids Mm, Other
Providing ICTP Main switch of Kilburn/LandT/Siemens/ Crompton/Standard/Havells make and having Capacity 30% extra of the Operational rating as per IS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.
Providing MS .sheet,steel fabricated floor mounted closed(Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm,duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:
A.C.B./Oil circuit breaker of Kilburn/L&T/MEI/GEC make & of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516-1985 with upto date ammendments with.
Earth leakage circuit breaker of recommended make (Kilburn/L&T/MEI/GEC) as per 2516-1977 with upto date ammendment and of suitable range which should have control box operating handle and trip/ reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be fitted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end.
The voltage monitor relay three phase with all protection and usual indicator and electric siren against single phasing low voltage,high voltage reverse phasing,over loading and phase voltage difference as per IS:3842(latest edition).
Power factor meter of standard make as per relevant IS code with upto date ammendments of suitable rating.
Frequency meter of standard make as per relevant IS code with upto date ammendments of suitable rating.
Bus bar chamber having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current,one copper bar of half the rating of full length for neutral phase as per IS:8084-1976 and IS: 11353-1985 read with BIS 5578-1985 with upto date ammendments
ICTP switches with HRC fuses of L&T/Crompton/Kilburn/Siemens/standard/Havells make and of suitable capacity as per IS 4064-1978 with upto date ammendments.
Three phase Indicator lamps complete with toggle switches for individual motors as per IS 3452(P-I&II) with upto date ammendments.
Capacitor of Mechneil/Bhel/GEC/ L&T/ make as per IS:2834-1986 with upto date ammendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of required KVA rating according to HP offered including cables chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064-1978 with upto date ammendments.
Providing suitable Oil immersed star delta/direct on line /auto -tran former/starter rotor starter of MEI/Kilburn/Jyoti/L&T/Siemens make as per IS 8544-1979 with upto date ammendments for squirrel cage/slip ring motor mounted on pannel board with magnetic type overload release and dashpot, time lag,under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248(P-V)- 1983 with upto date ammendments.
Providing Hour run meter of recommended make of suitable capacity as per IS:722(Latest edition).
Prov. Antivibration pads under the pumps and motors of suitable size for the above pumping machinery as per IS; 6337-1971
Prov. Cast iron flanged/screw type foot valves with strainer as per IS: 4098-1986 with upto date ammendments of Kirloskar/Mechneil/Kilburn/Leader/make 65 mm
Providing double flanged Cast Iron sluice valve of leader / Bhel/Kirloskar/Kilburn/GLED/Fouress/ make and of 250 mm dia for the delievery line of pump and capable of with standing normal seat pressure as per IS-780-1984 with upto date ammendments
Providing double flanged Cast Iron sluice valve of leader / Bhel/Kirloskar/Kilburn/GLED/Fouress/ make and of 250 mm dia for the delievery line of pump and capable of with standing normal seat pressure as per BS-1414 with upto date ammend
Providing double flanged(Swing type) Cast steel Reflux valve of Leader/Bhel/Kirloskar/Kilburn/GLED/Fouress make and of…250 mm dia..having bye pass arrangement on the delivery line of pump and capable of with standing normal seat pressure as per BS:1868 (P.I) with upto date ammendments
Providing double flanged Cast steel Reflux valve of Leader/Bhel/Kirloskar/Kilburn/GLED/Fouress make and of 250 mm dia. having bye pass arrangement for Rising Main and capable of with standing normal seat pressure as per BS:1868 (P.I) with upto date ammendments.
Providing 250mm dia circular dia pressure gauge of Fiebing/Bourden Prega/precision make complete with all accessories such as stop cock, copper tubing etc. as per IS 3624-1987 with upto date ammendments.
Precision make complete with all accessories such as stop cock,copper tubing etc. as per IS 3624-1987 with upto date ammendments
Prov.discharge meter standard make to be tiked on the rising main near the storage tank as per the directions of the Engineer-in-charge as per IS-2373-1981 with upto date ammendments.
Installation of all the items appearing at Serial No. 94 to 118…as per the systematic drawing attached with the tender documents
Providing and fixing double flanged MS/GI piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the the rising main respectively complete with all specials such as bends, tees reducers/increasers with companion flanges matching with the relevant specifications of the accessores as indicated in the drawing No 2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS 1364-1983. The pipes shall be as per relevant IS code and to withstand 1.5 times total head stipulated under item No.1 The size of the various components to be as under:-(I) Suction pipe…250 mm dia. (ii)Delivery pipe…250 mm dia.(iii)Common Header 250 mm dia. and will extended upto 5 mtrs from the outer wall of the pump house in the direction to be jointed. Providing and laying copper PVC insulated armoured power cable(one cable carrying all the three phases)of suitable size and capacity to and all other electrical equipments as per IS:1554(P-I)1988 or latest with upto date ammendments of Siemens/Gloster/ JEC/ICC/EICO National/Grandlay make including all other accessores such as thimbles, flexible,pipes solder,nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
Providing and fixing double loop earthing and copper plate 600mmx600mmx3mm thick electrode complete with material such as thimbles, nuts and bolts,charcoal and common salt,25mmx3mm copper strips/as per IS: 3043-1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc,complete in all respect.
Providing & Errection of power oprated over head travelling Crane Gantry 5 Tone
C/o Water Treatment Plant (WTP) of 2.53 MLD capacity, including design and drawings and all site development along with trial run and complete i/c clear water tank 1700000 ltrs. Construction and commissioning of Water Treatment Plant (WTP) of 2.53 MLD capacity with Rapid Sand Filtters, complete in all respect, including all components viz. civil works, machanical & electrical equipments, gassous chalorination chambers, inter-connecting arrangment (approaches and walk ways/path in the complex) and eleterification of the complex (yard lights), Fencing on boundary of the WTP including all site development works with in WTP area and all other allied work; along with trial run & Operation & Maintenance of the WTP for six months. The cost shall include hydraulic and structural design and drawings of the WTP, the construction of treatment units owing to scope of work, design parmeters, and all other works as per manual on Water Supply and Treatment by CPHEEO (latest with upto date ammendments), by Ministry of Urban Development, New Delhi.
Operation & Maintenance for 5 Year (Whole Scheme)
1st Year
2nd Year
3rd Year
4th Year
5th Year
Automation System
Providing, fixing & testing of micoprocessor based .Automation system / Starter of of reputed Make approved by I&PH Department suitable for operation in 360-440 VAC, 3 phase ambient temperature of 25 Deg Cen. Ram up time 0-20 second with all connections needed to make motor pump run sucessfully. The Automation system /Soft Starter should be offered with cabinet including panel board with accessories of reputed make aproved by I&PH Department with ammeter,volt meter, push button & single phase preventor and controller for automatic reset for all tripping ( like over voltage,under voltage,over load & short circuit etc.) with level sensors for tank up & down water level, complete in all respects. The automation system should make the motor and pump run automatically. as per parameters in ANNEX-1 attached for the pumping Machinery as under.
Pumping machinery Booster Stage 1st Stage
No. of stages = 2 Stages
Static head 45.00 Mtrs. 400.00 Mtrs.
HP 2 X 70 HP 3 X 150 HP
Prov.& Fixing buik meter on the delivery side of the main storage tank , WTP , Sector Storage Tank Etc. so as to measure total quanitity of water lifted per day in each stage.
Prov.& Fixing hour run meter to measure total runing hours of the pump/motors.
Construction of Road 2000 Sqm for WTP/ Pump House Etc.
Providing Fixing IOT enabled MULTIJET/ Turbine WOLTMANN type machanical bulk flow meter specification of reputed make confirming to ISO 9001 certification with removalbe mechanism, having dry dial, magnetically coupled, hermetically sealed totalized, Class ’B’ as per ISO 4064 (International standards). Meters must be pre-equipped for AMR (Automated Meter Reading)capable of resisting pressure up to PN16, PVC/Cast Iron strainer, fittings, cuttings, threading, plumbing and elecrical accessories engineering with all leads and lifts as per direction of Engineer In-Charge.
Bulk Flow meter Machanical Turbine Type
METAL BOX: Providing Fixing MS Metal Sheet minimum 1.0 mm thick metallic Box size [30x30x30 cm] bottom less with MS ANGLE [25x25x5mm ] legs of 150 mm height properly anchored/ grouted in ground with CC 1:2:4 (cement concrete) as per specifications with LOCKING arrangments duly redoxide and paint on all side inside outside to house Bulk Flow meter with all leads and lifts as per direction of Engioneer In-Charge.
TURBIDITY SENSOR: Providing Fixing NEPHELOMETRIC Turbidity sensor based NEPHELOMETRIC measuring principle 90°NIR [Near In-fra Red] scattered light according to ISO 7027: 1999, measurement at wavelength 860 ƞm with turbidity range [0-100 NTU] including all accessories like plumbing electrical, cabling, engineering with all leads and lifts as per direction of Engineer In-Charge.
Communication Devices:
LORA UNIT: Providing Fixing RTU [Remote Terminal Unit] operated with 5 V Li Ion battery for secured transfer of DATA from sensor/ Flowmeter with networking cellular LORA/ Wi-fi/NB Wi-fi ethernet RF range -400m-1000m (for LORA based RTU) Secured transmission of telemetry via MQTT/AMQP/HTTPS using TLS/DTLS/AES standards including memory card for storing DATA for a minimum of 30 days in case of power failures/loss of connectivity complete in all respect with certification with all leads and lifts as per direction of Engineer In-Charge.
LORA GATEWAY UNIT WITH NANO SIM: Providing Fixing DATA coommunication GATEWAY device with solar powered supply (shall be measured and paid seperatly) for DATA acquisition from RTU and Communication through secured transmission telemetry with standards protocol using LORA/Wi-Fi/NB Wi-Fi cellular /GPRS ethernet for connecting to Cloud server for at lease 2 months DATA back up as per detailed specifications with all leads and lifts as per direction of Enginmeer In-Charge.
Stop overflow loss [ESR level based pump automation]
Consumer Flow meter: Providing Fixing IOT enabled MULTIJET WOLTMANN type machanical bulk flow meter specification of reputed make confirming to ISO 9001 certification with removalbe mechanism, having dry dial, magnetically coupled, hermetically sealed totalized, Class ’B’ as per ISO 4064 (International standards). Meters must be pre-equipped for AMR (Automated Meter Reading)capable of resisting pressure up to PN16, PVC strainer, fittings, cuttings, threading, plumbing and elecrical accessories engineering with all leads and lifts as per direction of Engineer In-Charge.
Pressure Sensor:Providing Fixing Pressure sensor enable to transmit pressure having pressure range [0.1 to 60 bars] having minmium IP-67 protection from moist and harsh envirnment capable of transmitting analog digital output 4-20mA to RS485 Modbus RTU [Remote Terminal Unit] operating temperature range of [-40℃ to 125℃] with complete acessories in all respect calibration certificate with all leads lifts as per direction of Engineer In-Charge.
Residual Chlorine sensor: Providing Fixing Residual Chlorine Sensor based on AMPEROMETRIC PRINCIPLE according to ISO 7393-2:2017 with a range od 0 to 05 ppm complete in all respect with all acessories with all leads lifts as per direction of Engineer In-Charge.
TV DISPLAY UNIT in GP: Providing Fixing LED TV DISPLAY UNIT minimum 43" cm screen of reputed make/ BRAND [SAMSUNG, LG, SONI, PANNSONIC] approved from Himachal Pradesh State elctronic corporation [DISPLAY RESOLUTION]: 1920 X 1080 full HD brightness: 32" 240 cd/m2, responce time 12ms or less, connectivity : 2 X HDMI in , X USB 2.0.1 X Components , 1XR 145, IX RS 232 built in Wi-Fi, Screen mirroring audio output RMS: 10 Watt X 2 or Better Warranty 3 years mounted to the wall with fixing standscomplete set will all acessories wiring cables, elecrical fittings networking cable linking with networking devices with all leads lifts as per direction of Engineer In-Charge.
SOLAR PANEL with Lead Acid Battery: Providing Fixing Reputred make and MNER approved Solar Panel Power Supply System to pressure sensor/ Communication GATEWAY device wiith 12V-10Watt SOLAR PANEL with 7.5 Ah ACID BATTERY properly mounted on GI pipe not less than 40 mm dia[light class] minimum 2.0 m height. the battery shall be properly fixed and encaged in a metal BOX duly painted on all side [inside outside]having locking arrangments complete in all respect wiring to the nearest sensor/ communication GATEWAY device with all leads and lifts as per direction of Engineer In-Charge.
SIGNAL IMPROVING DEVICE
Providing Training to the departmental personnel on site in assembly startup,operation,maintenance an/or repair of supplied goods,course topics will include sensor calibration,datalogges cenfiguration data downloading,data retrieval collection,troubleshooting,processing maintenance requirements and procedures for equipments and procedures for equipment configuration,installation,site testing and commissioning including kit containing course material in soft & hard copies as per technical specification.
OPERATION & MAINTENANCE COST for 1st 2 yrs Warranty Period +5 Year complete in all respect by maintaing all the instruments during warrantee period and maintenance period of 5 years with replacement/ repair of all damaged or non functioning units/ components including acessories.
Ist Year
2nd Year
3rd Year
4th Year
5th Year
Add 6.25 % Electrical /Sanitary fitting
HILL CONSTRUCTION AND ENGINEERING CO. SOLAN
Unipro Techno Infrastructure Pvt Ltd
HYDRAULIC ENGINEERING COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf