| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹32.9 L+₹5.4 L (19.8%)Rejected-Finance | L2 | Rejected-Finance Other Than First Lowest |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
9 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Jaipur
GE Jaipur
REPAIR/MAINT OF CEILING, CHAJJA, PARAPET, STAIRCASE AND CONNECTED ITEMS IN MD ACCN IN ZONE-II AREA UNDER AGE B/R-II OF GE JAIPUR
2023_MES_607464_1
GE/J-41/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE Jaipur
As per tender document
5 documents required · 5 mandatory
₹500
Jaipur
₹70,000
Yes
5 Dec 2023
30 Jun 2023
11 Sept 2023
30 Jun 2023
9 Sept 2023
26 Aug 2023
Amount
Dismantling of loose reinforced cement concrete any description by chieseling , wedging etc. cutting the unserviceable reinforcement as in chajjas, projections slab, similar suspended slabs complete all as specified and directed incl removal of all rubbish material where directed complete all as specified and as directed by Engineer-in-charge.
M&L cleaning the rusted reinforcement and exposed surface by wire brush, mechanical device or any other established method and applying the rust removing solution of approved make and quality with cotton swab to reinforcement and allowing to dry the same for 24 hrs, brushing of loose particles and applying 1st coat of rust preventive coating of polymer and cement slurry in 1:1.5 proportion with soft brush without adding water including applying another coat of rust preventing after 4 hrs allowing air curing for 48 hrs etc. complete all as specified and as directed by Engineer-in-charge.
S&F MS TMT bars 6 mm to 8 mm dia cut to length bent to shape reqd incl cranking, bending spirally for hooping for cols, hooking ends and binding with steel MS wire (annealed) not less than 0.9 mm dia complete all as specified and as directed by Engineer-in-charge.
,--ditto--- all as per srl item No 3 above but 10 mm dia & over complete all as specified and as directed by Engineer-in-charge.
Material and labour for shear key connectors: Drilling holes in concrete surface of columns of suitable diameter, providing and fixing 8 mm diameter High Yield Steel reinforcing bars at on the RCC surface at 300 mm c/c or as per site requirement. Shear keys shall be 75mm long with embedment length of 40mm and projecting out of the concrete surface with a horizontal bend of about 25mm including material and labour for fixing with anchor fix to fill the hole completely complete all as specified and as directed by Engineer-in-charge.
Providing and applying a non shrink, polymer modified cementitious micro-concrete having compressive strength (BS 4551-80)-50 Mpa at 28 Days, Tensile strength- 2 Mpa @ 28 Days, Flexural Strength(BS 4551-80)-5 Mpa at 28 Days. product shall have A1 Class Fire Rating confirming to EN1504 cl 5.5, Thermal conductivity of 1.5W/m degree C. Pouring the same into the formwork using suitable arrangement or if required using pumping device for uniform flow of micro concrete. Rate is inclusive of preparatory works from item 1 to item 5 above rates also includes cost of materials labour, tools and plants, cost of shuttering & scaffolding, safety arrangement quality control and testing etc. complete as per specification and as directed by Engineer.-in-charge.
Carefully chipping, removing existing loose/ damaged concrete with plaster from Roof slab, Ceiling, floors (including ground floor), beams, staircase and similar items by low impact high frequency hammer/ chipper without damaging the existing sound concrete and exposing old reinforcement upto 10mm beyond corroded reinforcement bars using electrically operated diamond concrete saw blade, making the edges straight and even and cleaning it by wire brush and then by air blower and removing/ disposal of rubbish to a distance exceeding 1.5 Km but not exceeding 5.0 Km complete all as specified and as directed by Engineer-in-charge.
Cleaning all existing reinforcement bars in Roof slab, Ceiling, Chajja, Fascia, Fins, Drops and similar items with wire brush/rotary wire brush to make entire circumference surface of bars free from rust scales, loose material, dirt etc., complete and applying alkaline rust converting primer on the existing rebar and allowing it to react with rust for 6 hrs and form a corrosion resistant, insoluble and adherent protective layer including cleaning the reinforcement, wire brushing to remove the rust spalls, complete as per manufacturers instructions, complete all as specified and as directed by Engineer-in-charge. Note :- Mode of measurement : per sqm of breaking area of concrete only. Make: Sika- Rustoff 100/Fosroc- Reebaklens RR /OM AGRO- DERUSTER / Pidilite Dr Fixit Rust Remover, Asian Paints Apcorep Rust Rem or Techno commercial equivalent make approved by GE in writing from E-in-C's Br approved list.
Providing and application of Zinc rich epoxy anti-corrosive protective coating for reinforcement bars as corrosion protection system in 2 coats to the entire circumference surface of bars (consumption Qty as per manufacturers instructions but min 0.4 kg/Sqm approx) in Roof slab, Ceiling, Chajja, Fascia, Fins, Drops and similar items. The product should confirm carbonation resistance of 2 mm and bond strength > 1N/sqmm according to ASTM C 882-78 complete all as specified and as directed by Engineer-in-charge Note :- Mode of measurement: per sqm of application area of concrete. Make: Sika- Friazinc R/ Fosroc- Nitozinc Primer/ Pidilite Dr Fixit Zinc Rich Primer, Asian Paints Apcorep Rust coat RB or Techno commercial equivalent make approved by GE in writing from E-in-C's Br approved list.
Apply Epoxy based bonding agent to the entire concrete surface prior to building up of concrete with Polymer modified mortar or any other treatment , including cleaning the surface to remove dirt, dust or any other impurities on the surface of Roof slab, Ceiling, Chajja, Fascia, Fins, Drops and similar items complete all as specified and as directed by Engineer-in-charge Make: Sika - SikaDur 32 LP / Fosroc - Nitobond SBR (EP)/ Pidilite Dr Fixit Super Latex (EP), Asian Paints Repair ploymer or Techno commercial equivalent make approved by GE in writing from E-in-C's Br approved list.
Rebuilding the section of structural damaged RCC/PCC elements on the surface of Roof slab, Ceiling, Chajja, Fascia, Fins, Drops and similar items Drops repair to spalling concrete to its original size and shape in 1st layers of 10 mm average thickness in 1st layer by providing and applying with pre-batched, one component fiber based repair mortar having compressive strength >= 50 N/sqmm (28 days) according to ASTM C 109; flexural strength >= 5N/ sqmm (7 days) according to ASTM C 293-79 complete all as specified and as directed by Engineer-in-charge. Make: Sika - Monotop 122 F/ Fosroc - Renderoc S2/ Pidilite Dr Fixit Polymer Mortar HB or Techno commercial equivalent make approved by GE in writing from E-in-C's Br approved list.
,--ditto--- all as per srl item No 11 above but for each addl 10mm uniform thickness for subsequent layers complete all as specified and as directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in floors, roof surface not exceeding 15cm thickness and removal of same from outside MOD land complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing hard drawn steel wire fabric cut to lengths, bent to shape as required and tying with suitable nut and fastener and including mild steel wire (annealed) not less than 0.9 mm in dia complete all as specified and as directed.
M & L for drilling and fixing teflon perforated nozzles in RCC members including drilling 14mm dia 50 to 100 mm deep holes in structural members at the intervals of 600 mm in staggered manner all as directed including cleaning the holes by air blowers prior to fixing nozzles and fixed nozzles in cleaned holes . External ends of nozzles to be machined to receive outlet of grouting gun. nozzle is fixed by mean of epoxy to ensure complete sealing and cure the system for min 12 hrs under supervision of qualified supervisor all as specified and directed.
M & L for injecting high performance non shrink, free from high strength antiwash polymer cement grout of approved make by addition of water as per manufacturers instructions and specification into honeycombing area/porous concrete including drilling of holes minimum 50 mm in concrete, fixing nipples, injecting grout by suitable pump at pressure of 2.0 Kg/cm2 and subsequently cutting/ removing of nipples and sealing of holes with epoxy putty EPW 1010 etc. complete all as directed by engr in charge.
M&L form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick finish with rough finish flat surface. The shuttering shall be of min 12 mm plywood sheets placed in position to receive flowable microconcrete.
M&L form work to chullah hoods, chajjas, troughs and similar items including edges finish with finish flat surface.
M & L Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work n exc 20cm wide with rough finished surfaces and staging upto 21 m from GL complete all as specified and
Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles and removal all rubbish material outside of MD Land complete all as specified and directed.
M & L brick work using Subclass B bricks in exc. 6 m mean radius on plan built in cement mortar 1:6 complete all as specified and directed.
Taking down cement plaster any description, on brick or stone walls, etc. including raking out joints, hacking for key & scrubbing down with water, etc. & removing rubbish outside MD land complete all as directed.
M&L rendering 15 mm thick in CM 1:4 on brick masonry surfaces or concrete surface finished even and smooth without using extra cement complete all as specified and directed..
M&L rendering 15 mm thick in CM 1:6 on stone masonry surfaces or on other than fair faces of brick masonry finished even and smooth witout using extra cement complete all as specified and directed.
M&L 15mm thick rendering in cement mortar 1:4 to stone masonry wall surfaces or on other than fair faces of brick wall surfaces finished fair & even etc complete all as specified and directed.
M&L rendering 5 mm thick in CM 1:3 including as on concerete surface on ceilings finished even and smooth without using extra cement complete all as specified and directed .
M&L rendering 5 mm thick in CM 1:3 in patches in ceilling, each patch n exc 3.00 sqm finished even and smooth without using extra cement complete all as specified and directed
M&L for thourughly wetted surface to ensure better sticking including sand paper gentle rubbing to obtain smooth surfaces, including all necessary arrangement for execution of work ,preparation of existing old surface with putty that applying (priming seal -o- prime ) on plastered surface and two coat of weather proof exterior emulsion paint (weather coat smooth) using hand roller on external Wall Surface, complete all as specified and as directed by Engineer-in-Charge.
M&L for thourughly wetted surface to ensure better sticking including sand paper gentle rubbing to obtain smooth surfaces, including all necessary arrangement for execution of work ,preparation of new plaster surface with putty that applying (priming seal -o- prime ) on platered surface and two coat of weather proof exterior emulsion paint (weather coat smooth) using hand roller on external Wall Surface, complete all as specified and as directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed by Engineer-in-Charge.
S&F Roof trusses (Framed), trussed, purlins, crane gantries, rails and fastenings and heavy brackets framing (Beam, tee, angle, channel or flat sections),including distance pieces, cleats etc conforming to Fe 410-W Gde E-250 quality A including fabrication, erraction and fixing complete all as specified.
M&L for complete removal of existing treatment on walls, including cleaning of any mortar drops, fungus efflorescent salts etc and preparation of old plastered surfaces and applying two coats of distemper with distemper oil emulsion white or tinted by mechanical means over a coat of primer over two coat of wall care putty to make smooth the undulated surfaces complete all as specified and directed.
M&L for complete removal of existing treatment on ceiling, including cleaning of any mortar drops, fungus efflorescent salts etc and preparation of old plastered surfaces and applying two coats of distemper with distemper oil emulsion white or tinted by mechanical means over a coat of primer over two coat of wall care putty to make smooth the undulated surfaces complete all as specified and directed.
M&L for preparing newly plastered surfaces and applying two coats of distemper with distemper oil emulsion white or tinted by mechanical means over a coat of primer over two coat of wall care putty to make smooth the undulated surfaces complete all as specified and directed. (Make : For wall putty- Birla white/Bison wall putty of Berger/Narolac wall putty/Asian paint powder putty /Acro wall guard.)
M&L for preparing newly plastered surfaces of ceiling and applying two coats of distemper with distemper oil emulsion white or tinted by mechanical means over a coat of primer over one coat of wall care putty to make smooth the undulated surfaces complete all as specified and directed.
Preparing new plastered surfaces of wall and applying two coats of Exterior acylic emulsion weather proof paint over and including a coat of alkali resistant primer (by mechanical means) complete all as specified and directed.
S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging also fastening and fixing complete all as specified and as directed by Engineer-in-Charge.
M&L preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-Charge.
M&L preparation of new steel surface of any description n. exc 10cm in width or girth when un connecting to other painting surface and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge.
M&L for Sand Stone slab 75 mm thick dressed true and square, in one length not less than 60cm and n. exc 120cm in copings, window cills, chajjas, sunshades,etc., punched dressed onexposed faces and self facedon the embedded unexposed beds and joints; exposed edges rounded or chamfered as directed, set, jointed and pointed in cement mortar complete
Taking down existing treatment complete including PCC and properly clean the surface to remove loose particles with wire brushes and removing the debris out side of MoD Land complete all as specified and directed by Engr-In-Charge
M&L for screed plaster 15 mm thick in CM 1:4 on roof surface complete and finished the surface even and smooth without using extra cement etc. .incl water proofing compound @2% by weight complete all as specified and directed
M&L for 25 mm thick cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregates ) as in RCC roof surface to horizantal surface etc complete all as specified and directed
The surface shall be painted with one coat of polymeric primer @ 0.30 Kg per sqm, conforming to IS: 3384. A layer of APP based polymeric membrane, 3 mm thick (min), weighing not less than 3.5 Kg/m2 reinforced with polyster non woven fabric ( weighing not less than 150 gms/ Sqm). Application of polymeric membrane shall be by torch application all as per manufacturer instructions. and finally applying one coat of bitumen @ 1.2 kg/sqm on APP membrane including two coats of aluminium paint complete all as specified and directed by Engr-in-Charge. Note : Roof treatment to be done through authorised applicator only
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
UNIVERSAL INFRAPROJECT PVT LTD
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .