Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC BALUMATH LATEHAR | ₹1.4 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.4 CrRejected-Finance ADD PAHARI TOLA NASRUDDIN LANE HILL SIDE RANCHI 834001 | RANCHI | JHARKHAND | 834001 | ₹1.4 Cr | L2 | Rejected-Finance L2 |
| 3 | Rejected-Technical 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | - | - | Rejected-Technical NON RESPONSIVE |
| Sl No | Description | Qty | Unit | MOHAMMAD IMRAN L2 | MD. ANWAR ANSARI L1 |
|---|---|---|---|---|---|
| 1.00 | RATE ANALYSIS OF SLDB | 4 | no | 9,888 ₹39,552 | 10,500 ₹42,000 |
| 2.00 | FIRE FIGHTING CYLINDER(MR) | 10 | Each | 6,250 ₹62,500 | 5,950 ₹59,500 |
Tender Value
₹1.4 Cr
EMD Value
₹2.8 L
Closing Date
11 Mar 2026, 5:00 pmClosed
EE RDSD LATEHAR
EE RDSD LATEHAR
Construction of Primary Health Centre at Busur in Block Latehar under Latehar Dist
2026_RDSPL_110575_1
EE/RDSD/LATEHAR/48/2025-26
Open Tender
Civil Works
210 days
LATEHAR
Please refer Tender documents.
3 documents required · 3 mandatory
₹10,000
₹2.8 L
Yes
11 Apr 2026
27 Feb 2026
13 Mar 2026
27 Feb 2026
11 Mar 2026
27 Feb 2026
RATE ANALYSIS OF SLDB
FIRE FIGHTING CYLINDER(MR)
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts. Leveling ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/I. Extra for earthwork in hard soil as per specification and direction of E/I. (vide classification of soil item
Filling in foundaton trenches and plinth in layers not exceeding 150 mm do-do-
Providing coarse clean sand in filling in foundation trenches or in plinth & floor including ramming & watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
Providing designation 75 B one brick flat soling do-do-do
Providing and laying in position cement concrete of specified grade |excluding the cost of centering and shutfering All work up to plinth level:1:2:4 (1 cement: 2 coarse sand (zone-1) :4 graded stone aggregate 20 mm nominal size)
Providing and laying in position cement concrete of specified grade|excluding the cost of centering and shutfering All work up to plinthlevel:1:3:6 (1 Cement: 3coarse sandzone-ll):6 graded stone aggregate 20
Providing designation 75B brick work in C.M.(1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm. Thick morter joints, cost of screening, materials, scaffolfing, raking out joints to 15mm. Depth curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 75B brick work in C.M.(1:6) in F OUNDATION with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm. Thick morter joints, cost of screening, materials, scaffolfing, raking out joints to 15mm. Depth curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 125 mm thick reinforcement designation 75 A brick work in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials, scaffolding raking out joints to 15 mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.
Providing designation 75A brick work in C.M (1:4) in foundation and plinth -do-
Providing and laying in positionspecified grade of reinforaed cement concrete, excluding the cost of centering, shutterhe. finishing and reinforcement- All work upto plinth level. 1.5:3 (1 cement: 1.5 course sand (zone-1): 3 graded stone geregate 20 mm nominal size)
Reinforded cement concrete work in beams suspended floors roofs having slope up to 15 landings balconies, shelves, chajas, lintels, bands, plain do-do-
Reinforced cement concrete work in wals do-do-
Centring and shuttering including strutting, propping etc. and removal of form for foundation, footings, bases of columns etc. for mass concrete.
Centring and shuttering including strutting propping etc and removal do-do-
Centring and shuttering including strutting, propping etc. and removal of form for lintel, beams, plinth beams, griders, bressumers and contilevers.
Centring and shuttering including strutting, propping etc. and removal of form for suspended floors, roofs, landings, balconies and access platform.
Reinforcement for RCC work including straightening, cutting, bending, placing in position and bonding all complete.TMTC-500 8mm dia
TMTC-500 10mm dia
TMTC-500 12mm dia
TMT-500 16mm dia
Providing two coates of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface do-do-
Supplying fitting and fixing callapsible gate of approved size and make properly fabricated do-do-do
Supplying fitting and fixing M.S grill made of 20x6mm m.S flate as per do-do
Providing two coats of synthetic enamel paint of approved shade and make over steel surface do -do-
Providing and fixing factory made uPVC door frame made of uPVC do-do-
24 mm thick factory made PVC door shutters made of styles and rails of a UPC do-do-do
s/f/f good quality wall dressed and well seasoned local wood do-do-
Sypplying fitting and fixing 30 mm thick solid core type do-do
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and laying Vitrified floor tiles in different size do- do-
Providing and laying ceramic glazed floor tiles 300x300 mm do-do-do
Providing and laying c Providing and fixing 1st quality ceramic glazed wall do-do-do-
Providing 12 mm , cement plaster (1:4)with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water ,scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 12mm thk. Cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I.
Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 19mm thk. Water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other water proofing compound including screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I.
Providing 6mm thk.cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per builing specification and direction of E/I.
Providing and applying white cement based putty 1 mm thickness over plastered surface to do-do-do
Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqmover and including one coat of Special primer applied @0.75 ltr /10 sqm
Providing and laying 25 mm. thick kotah stone tiles in risers of steps do-do-do
Providing 150mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
(i) C.I. cover and frame 300 x 300 mm inside
(ii) S.C.I. plain bend 100 mm dia
(iii) S.C.I. Tee 150 mm dia
With 10 lit. low level P.V.C Cistem
10 lit. low level P.V.C cistern
Supplying, fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S approved make supported on painted C.I. or R.S. brackets 32mm C.I. brass waste, 15mm dia C.I. body spindle stop cock of approved quality of weight not less than 350grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I.
Supplying fitting and fixing white glazed fire's clay sink of approved make with overflow arrangements supported on C.I. or R.S. painted brackets 40mm. dia C.P. brass waste with C.P. brass chain and rubber plug 40 mm dia P.V.C. waste pipe about 750mm long with brass coupling at one endand 15mm C.I. body brass spindle bib cock of approved quality of weight not less than 450grams. including cutting wall and making good the same etc. all complete as per specification and direction of E/IKitchen sink 600 mm x 450 mm x 250 mm
Supplying, fitting and fixing H.C.I. pipes with ear of approved make conforming to I.S.I. 1729 including supplying nails and bobins short pieces, cutting loose collars, lead and yarn for making lead caulked joints, cutting pipes to size including earth woek or scaffolding where necessary etc. all complete as per specification and direction of E/I.100mm dia
75mm dia
Supplying and fixing H.C.I. fittings of approved make confirming to I.S.S. 1729 including supplying nails and bobines lead and yarn from making lead caulked joints including earthwork or providing scaffolding as the case may be all complete as per specification and direction of E/I.H.C.I. Heal Rest bend100 mm dia (wt. 5.5 kg. app)
80 mm dia (wt. 4 kg. app)
100 mm dia (wt. 15.5 kg. app)
80 mm dia (wt. 15.5 kg. app)
100mm dia
100mm dia (wt. 3.25 Kg appx.)
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.110 mm
110 mm bend
110 mm Shoe
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 15 mm dia
20 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.25 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :100 mm diameter S.W. pipe
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :15 mm nominal bore
25 mm nominal bore
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI :12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size of GI box etc as required.Group C
Twin control Point Wiring in PVC Conduit, with Modular type Switch:- Wiring for twin control light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with 2 way modular type switch, modular plate, suitable size of GI box etc as required.
S/F Ceiling Rose :- Supplying and fixing 2pin 5 amp ceiling rose on the existing junction box/wooden block including connection as required etc.
S/F Modular type electronic fan regulator :- Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required.
Supply, fitting, fixing and testing of 1200mm Sweep, double ball-bearing, 2 canopy ceiling fan including connection with 1.5 sq mm copper wire, down rod all accessories as required.
S.I.T.C of following rating surface mounted LED tube lightfitting suitable for 230V 50Hz, single phase supply etc. compete as required.20w/22w LED tube
Bulk head fitting with 9/10 Watt LED
S.I.T.C of following rating LED post top lamp made in die cast aluminium housing with decorative claer/opal acrylic diffuser on existing pipe including connection with 1.5sq.mm. copper conductor etc all complete as required.45w LED Post top lamp opel
12" (300mm) Exhaust fan
Installation of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of he above fan making good the damage, connection, testing, commisionig etc as required.
S/F light plug point with modular type accessories :-Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc, as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing 20 amps 240V, SPN industrial socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP MCB insheet steel enclosure on surace or in recess with chained metal cover for the socket outlet and complete with connections, testing & commissioning etc.
Supplying and fixing modular blanking plate on the existing modular plate & switch box but excluding modular plate as required.
4 Way (4 + 12), Double Door, Horizontal type
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor single core cable in surfacce/ recessed medium class PVC conduit.4R X 10 sq. mm + 2R x 6 sq.mm Earth Wire
4R X 16 sq. mm + 2R x 6 sq.mm Earth Wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor single core cable in surfacce/ recessed medium class PVC conduit.2R X 4 sq. mm + 1R x 4 sq.mm Earth Wire (Sockets)
2R X 2.5 sq. mm + 1R x 2.5 sq.mm Earth Wire (Switch Boards)
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed armoured electrical cable with aluminium conductor for working voltage upto 1.1 KV etc as required. 3.5c x 95 sq.mm
Supplying all materials, labours and tools and equipment for drilling 200x150 x125mm dia bore well in any kind of soil and rock by using DTH Super Rig machine and ball hammer technology inclusive of mobilization, demobilization, demobilization of rigs air compressor all accessories of rigs tool and plant labour etc. all complete job including transportation charge.(a) 0.00 to 50.00 M below G.L.
(b) 50.00 to 125.00 M below G.L.
Supplying, assembling, lowering and fixing in vertical position in bore well, un-plasticized PVC medium well casing (CM) pipe of required dia, all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia.
Development of tube well in accordance with IS : 2800 (part I) and IS:11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, all as per requirement and direction of Engineer-incharge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe,Nremovable as per requirement, all complete for borewell of 150Nmm dia.
Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts required size complete. 150 mm clamp.
Supplying fitting and fixing of KSB/KIRLOSKER/CRI make 1.00/1.5HP Submersible pump set having head of 135 metre including all taxes, royalty, etc.all complete job as per direction of E/I.
Supplying of 3 core 4 sq. mm flat copper cable of Finolex make for pump set connection with panel board including labour cost and making conneting etc. all complete.
Cost of one of ISI marked extre deep indiaa mark -II hand pump confirming to IS 13287 :1992 with latest amendment no Is 1to 6 complete with all ......do....do......E/I.
Supply fitting and fixing lowering 40 mm dia G.L do-do-
LOCAL SAND
STONE CHIPS
CEMENT
STEEL
BRICKS
Add 18% GST
Add 1% Labour Cess
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
technical_149494.pdf
techsummary_149494.pdf
finance_149494.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
Sbd_48.pdf
Tender Documents • 1.45 MB
BOQ_149494.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid