| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹81.2 LAccepted-AOC RCP GURUDWARA ROAD WARD NO 29 SURATGARH SRI GANGANAGAR 335804 | SURATGARH | SRI GANGANAGAR | RAJASTHAN | 335804 | L1 | Accepted-AOC Bidder fulfills requisite criteria and being lowest | |
| 2 | L2₹83.5 L+₹1.6 L (1.96%)Rejected-Finance | L2 | Rejected-Finance Bidder fulfills requisite criteria but not being lowest. | |
| 3 | L3₹84.3 L+₹2.4 L (2.90%)Rejected-Finance H 8 NO 15 SCHOOL KE SAMNE OUTSIDE JASSUSAR GATE BIKANER | BIKANER | BIKANER | RAJASTHAN | L3 | Rejected-Finance Bidder fulfills requisite criteria but not being lowest. | |
| 4 | L4₹86.5 L+₹4.6 L (5.63%)Rejected-Finance NEW ABADI KISHANPURA SURATGARH 335804 DISTT SRIGANGANGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L4 | Rejected-Finance Bidder fulfills requisite criteria but not being lowest. | |
| 5 | L5₹92.2 L+₹10.3 L (12.6%)Rejected-Finance BHAGAT SINGH CHOWK SURATGARH 335804 DISTT SRIGANGANAGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L5 | Rejected-Finance Bidder fulfills requisite criteria but not being lowest. |
Tender Value
₹84.8 L
EMD Value
₹1.5 L
Closing Date
18 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF BIKANER
HQ CWE AF BIKANER
PROVN OF OTM ACCN FOR PAR AT AF STN SURATGARH
2022_MES_501449_2
81467/E8
Open Tender
Civil Works
Lump-sum
270 days
GE AF SURATGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE AF SURATGARH
₹1.5 L
Yes
25 Apr 2022
25 Mar 2022
20 Apr 2022
25 Mar 2022
18 Apr 2022
4 Apr 2022
25 Mar 2022 - 1 Apr 2022
60 days
Amount
Schedule 'A' Part-I (BUILDING WORK)
Construction of OTM Accn for PAR at AF Stn Suratgarh complete all as specified and as shown on drawing.
Schedule 'A' Part-II (DEMOLITION AND DISMANTLING )
Lump sum price worked out by contractor for "DEMOLITION AND DISMANTLING ” as listed in Schedule ‘A’ Part- II.
Schedule 'A' Part - III (INTERNAL WATER SUPPLY)
Lump sum price worked out by contractor for "INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part- III.
Schedule 'A' Part- IV (INTERNAL ELECTRIC SUPPLY)
Lump sum price worked out by contractor for "INTERNAL ELECTRIC SUPPLY" as listed in Schedule 'A' Part- IV.
Schedule 'A' Part- V (EXTERNAL ELECTRIC SUPPLY)
Lump sum price worked out by contractor for "EXTERNAL ELECTRIC SUPPLY " as listed in Schedule 'A' Part- V.
Schedule 'A' Part- VI (ROAD/ PATH )
Lump sum price worked out by contractor for "(ROAD/ PATH " as listed in Schedule 'A' Part- VI.
Schedule 'A' Part-VII (SEWAGE DISPOSAL)
Lump sum price worked out by contractor for "SEWAGE DISPOSAL" as listed in Schedule 'A' Part-VII.
Schedule 'A' Part-VIII (FIRE SENSOR )
Lump sum price worked out by contractor for "FIRE SENSOR " as listed in Schedule 'A' Part-VIII.
Schedule 'A' Part-IX (ANTENNA PEDESTAL PLATFORM)
Lump sum price worked out by contractor for "ANTENNA PEDESTAL PLATFORM " as listed in Schedule 'A' Part-IX.
Schedule 'A' Part - X (EXCAVATION, EARTHWORK & SITE CLEARANCE )
Lump sum price worked out by contractor for " EXCAVATION, EARTHWORK & SITE CLEARANCE ” as listed in Schedule ‘A’ Part- X.
Schedule 'A' Part -XI (MISCELLANEOUS ITEMS)
Supply and fixed LED tube light fitting 18 to 20W with batten luman maintenance>70% at 50,000hrs,colr temperature of 5000-6500K,> color rendering and LM80 test compliance.The driver must be integral APFC and constant current type having THD<15% and power factor>0.95 with short circuit protection,open protection,rverse polarity protection,high voltage protection complete with all accessories all as specified and as directed
Supply and fixed LED mirror tube light fitting 10W with batten luman maintenance>70% at 50,000hrs,colr temperature of 5000-6500K,> color rendering and LM80 test compliance.The driver must be integral APFC and constant current type having THD<15% and power factor>0.95 with short circuit protection,open protection,rverse polarity protection,high voltage protection complete with all accessories all as specified and as directed
Supply and fixed Vertical TPN DB 4 way double door having ,IP : 43 Protection, Shrouded Neutral Bar & Pan assembly with flexible connecting link, Cement Spill Protector, Door Earthing with provision of MCCB upto 100 Amps and replastering the damaged area all as specified and directed by engr-in-charge
Supply and fixed MCCB four poles,63 Amps, breaking capacity 25 KA with adjustable thermal and magnetic setting confirming to IS-8828, 415 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc.
Supply and fixed MCB SPN.32 amps 'C' series, breaking capacity 10 Ka, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc.
Supply and fixed MCB SP, 6 to 32 Amps, C series, breaking capacity 10 KA, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc.
Supply and fixed ceiling fan 1400mm 230V ,50Hz all as specified and directed by engr-in-charge.
Supply and fixed exhaust fan 300mm sweep,900 RPM 230 volts single phase AC supply with louvers complete with bolts,nuts and washers,suitably embedded in the wall making suitable opening and provisioning of flexible copper cord three core PVC sheathed of size 23/0.0076 from ceiling rose to exhaust fan all as specified and directed by engr-in-charge.
Supply and fixed wall mounted fans 450mm 230V, 50Hz alongwith all necessary connections upto ceiling rose all as specified and directed by engr-in-charge.
Supply and fixed LED street light 45W with IP 43 protection ,50Hz single phase with support clamp fixed on wall and with flexible wire upto ceiling rose all as specified and directed by engr-in-charge
Supply and fixed LED flood light 80W with IP 43 protection ,50Hz single phase with support clamp fixed on wall and with flexible wire upto ceiling rose all as specified and directed by engr-in-charge
Material and labour for providing Fazilka river sand as in sand cushioning to under ground cable including punning down of sand in layers as specified and as directed
Make bore to road width for providing GI pipe medium grade both end socketed for passing armoured cable complete all as specified.
Supply, installing, testing and commissioning factory made LT feeder pillar box outdoor type platform mounted, suitable for 415 volts 3.5 phase 4 wire, 50 Hz AC supply system all as specified and directed having bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.5.15 mm CRCA MS sheet with front and rear opening type with double door shutter and locking arrangement (including provn of lock with 2 keys), powder coated finish (over a coat of red oxide), primer on outside and two coats of red oxide primer on inside surface. The panel is including platform with PCC 1:4:8 type D-2 with 40mm crushed stone aggregate 20cm in thick in foundation and of height upto 0.5 mtr all as directed at site . All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN copper bus bar of rating not less than 1.5 times rated capacity of individual MCCB and should be insulated with shrinkable PVC sleeves. The MCCB should be adjustable type. The scope of work includes provision of following. Note: All MCCBs should have adjustable thermal and magnetic settings (i) MCCB 4 pole 35 kA 250 Amp with thermal settiing 80-100% - 01 No (For incoming). (ii) MCCB TPN 32 Amp- 03 Nos . (iii)MCCB 4 pole 125 Amps 25kA-02 Nos. (iv) MCCB 4 pole 63 A 25kA-01 Nos. (v) MCCB 4 pole 40A 25ka-02 Nos(Spare) (vi) Internal wiring with PVC insulated, multi stranded copper conductor cable, 1100 V grade, IS 694 marked of appropriate size but not less than 2.5 sqmm. (vii ) Digital Voltmeter & Ammeter with necessary CT's.Make : AE/Conserve/Rishabh (viii) Phase indiacting lamps (R-Y-B) - 01 set.
Supply and fixed onload changeover switch 160 Amp 4 pole having staggered terminals suitable for AI links in sheet steel enclosure for switching to main and DG complete all as specified and as diredted.
Material and labour for commissioning, installation and testing of maintenance free UL approved copper bonded earth rod of 10 feet length, 17.2 mm dia. (as per drg) made of high tensile low carbon steel rod , molecularly bonded with 99.9% electrolytic grade copper on outer surface ( minimum copper bonding thickness - 250 microns) with exothermally jointed copper bus bar of 50 X 6 X 200 mm for connection. The rod and exothermic joint together successfully tested at 25 KA fault current by CPRI with 50 Kg eco friendly earth enhancing compound with each earth rod. The earth pit should be 125 mm dia. the compound should comply to IEC:62561-7 having passed leaching, corrossion, sulphur and resistivity test as per IEC: 62651-7 by NABL accredit Lab with FRP earth pit cover of top size lockable Lid. It includes GI Protection pipe light grade of size 40 mm dia. with GI strip of size 32X6 mm upto test point complete all as specified and directed by Engr-in-charge. Make JMV LPS Ltd/ OBO/ENNOV Infra solutions Pvt. Ltd/ erico /powerbolt Note:- Copper Strip connecting between two earthing will be measured and paid seperately in respective item. (a) The test result of each unit of earthing is less than 1 Ohm. All earthing test will be carried out in presence of Engr-in-Charge, manufacturer Rep, user rep and officer detailed by Accepting officer and test result will be recorded in a register with sign of all present. (b) 2 Year guarantee certificate from company for maintaining earth result less than 1 Ohm will be submitted by contractor. (c) 1425 RTC SS universal clamp of size 175 x 50 x 3mm (d) Earth enhancing compound (PROCEM) ECS GB 25 tested as per IEC 62561-7-25Kg (e) Chemical earthing will be installed by manufacturer Rep and purchase voucher of earthing will be produced before payment. Payment shall be made only after getting satisfactory result.
Supply, installing, testing and commissioning of 4c x 2.5 sq. mm, PVC insulated FRLS Armoured copper cable for SLC Loop & Power Supply, confirming to IS standards and specifications complete as required as per technical specification.
Network Repeater Panel with 6 inch or 640-characters; The LCD shall Display all events / detectors, devices status of complete systems in the networked, The NRP shall be equipped with QWERTY Keypad. Mounting options include an annunciator box, and blank modules are required for mounting.
Supply and fixed air cooled split unit air conditioner electric driven single phase of capacity of 1.5TR BEE 5 star rated all as specified and directed by engr-in-charge
Supply and fixed air cooled split unit air conditioner electric driven single phase of capacity of 2TR BEE 5 star rated all as specified and directed by engr-in-charge
Supply and install voltage stabliser for automatic operation single phase air cooled indoor type input variation between 170V to 280V with output voltage stablized at 230V wall mounting of capacity 5 kva all as specified and directed by engr-in-charge
Supply and fix single pole and neutral enclosures with two pin, earth plug and socket complete with one MCB SP 20 Amp capacity complete all as specified and as directed.
H S BUILDERS
M/S GODARA CONSTRUCTION CO.
M/s JUGAL KISHORE MISHRA AND SONS
M/S Shree Ram Enterprises
M/S BUDHRAM BISHNOI
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .