Loading…
Loading…
Tender Value
₹2.0 Cr
EMD Value
₹4.1 L
Closing Date
14 Jul 2026, 3:00 pm
Similar tender results from the same govt authority in the past 3 years.
S&T works in connection with Manmad - Mudkhed - FS+TWS+ WCMSC - 74 sets, CS+CMSC - 3 sets, SEJ 42 Sets in Nanded Division
N-SG-36-2026-27-TWS-74-17
N-SG-36-2026-27-TWS-74-17
Open
12 Months
Nanded, Maharashtra
₹0
₹4.1 L
22 Jun 2026
22 Jun 2026
30 Jun 2026
Supply of 50V, 10000µF electrolytic condenser of reputed brands like Philips / Keltron or similar. Inspection by CONSIGNEE.
Supply of Electric Track Drilling machine shall be suitable for operating on 110V, 02 50Hz AC / DC fully insulated and no-load RPM shall be 1900 / 1000 and the power input is 550W. Machine with suitable inter changeable track mounting stand and drilling to be designed with adjustable facility and along with a set of 20 nos of 7.2 mm dia Bosch MSS drill bit, Drill check dia. 13 mm and drilling dia in steel 8 mm/13 mm along with packing accessories. Inspection by CONSIGNEE.
Supply of Various Tools for S&T installation
Supply of Insulations for Ground connections
Supply o f High Availability Single Section Digital Axle Counter (HASSDAC) system complete as per RDSO specification RDSO/SPN/ 177/2012 Ver. 3.0 or latest. The system shall consist of the following: a) Track side high availability digital axle counter unit - 2 Nos. b) Axle detectors 09 (Each set consists of web mounting type 2 Nos Tx coils and 2 numbers Rx coils) - 2 sets c) Vital relay box - 2 numbers. Each box shall be wired with following relays. d) Vital Relay QNA1K, 24V, 6F/6B - 2 Nos. e) Reset Relay QNA1K, 24V, 6F/6B - 1 No. f) Preparatory PR Relay QNN1, 24V, 6F/2B (Dual) - 1 No. g) Clamp with deflector plates and hardware - 4 Nos. h) Reset box Model No.259A - 2 Nos. i) Surge Voltage Protection Device Mounted on DIN 35 Rail - 2 Nos. Inspection by RDSO.
Supply of GKP type Location Boxes
Supply of Etype lock of specified ward as per requirement with one key E-type lock to DRG. No.SA3376/M or latest and specification IRS: S30-64 or latest. Inspection by RDSO.
Supply of relay fixing frame for full location box. The frame shall be of approximate size 940mmx150mm and made with powder coated MS angle of 25mmx25mmx 3mm. The frame shall have suitable holes to fix in full location box. Inspection by CONSIGNEE.
Supply of relay fixing frame for half location box. The frame should be of approximate size 470mmx150mm and made out with powder coated MS angle of 25mmx25mmx3mm. The frame should have suitable holes to fix in half location box. Inspection by CONSIGNEE.
Supply of Track feed battery charger to work on 110V AC for charging1or 2 or 3 or 4 lead acid cell of 80AH (10Amps) used in track circuit as per RDSO Specn. No. IRS.S.89/2013 Ver 1.0 latest. Inspection by RDSO.
Supply of Track lead junction boxes fibre glass as per DRG.No.CWM-00597 of F.R.P 17 material to and specification IRS:S 23 along with fixtures i.e., one MS angle 50mmx50mmx5mm, 0.9m long, two numbers of G.I pipes of 25 mm dia, 500 mm long along with nuts and bolts and 500 mm long (grommet bushes, 60 mm ARA terminals-2 Nos). Inspection by RITES.
Supply of Galvanised Wire rope 6/19 steel, 6 mm dia with fibre core as per specification IS 3459/2004 or latest. Inspection by CONSIGNEE.
Supply of B type chokes to as per specification IRS: S65- 83 Amd.1 or latest. Inspection by RDSO.
Supply of Ethernet to E1 Converter (Ethernet port to G.703) with four Ethernet ports to one E1. The converter shall have the provision of dual AC / DC power supply. Inspection by Consignee.
Supply of Double Walled Corrugated (DWC) HDPE duct of various diameter of length 26 of 6m as per specification RDSO/SPN/204/2011 Ver. 1.1 Amd. 1 or latest. The duct shall be supplied along with push-fit type O-ring coupler or end cap. DWC of outer Diameter 63mm and inner Diameter 50mm. Inspection by RITES.
Supply of Stationary low maintenance secondary lead acid cells as per RDSO specification IRS: S88-2004 or latest. This includes supply of inter cell connectors, bolts, nuts, acid level indicating floats and vent plugs. 2V, 300AH. Inspection by RDSO. Above/
A2-Supply Portion (Non-SOR Items) 3106499.00 Below/P
Supply of double wire signalling rope (galvanised) 6X19 as epr spec. No. IRS S11/62 01 with latest ammendements. The galvanised wires to be used for making rope with jute core. The tensile breaking strength 140/160 Kg/m2 and nominal dimetre of the wire shall be 6mm. Inspection by CONSIGNEE.
On-Line UPS with isolation transformer suitable for single phase AC input & single phase AC output, Floor Mounted Type: Rating of UPS: 1.0 KVA, Indicative Back-up time: 30 Minutes. Inspection by RITES.
Standard Maintenance Free Battery 12V -42AH Exide make or similar accepted make: Exide. Inspection by CONSIGNEE.
Supply of sealed maintanance free battery rechargable VRLA battery of 12v/100AH make amaraja , exide & panasonic.Inspection by CONSIGNEE.
Supply of paper Roll for Plotter Machines (36" x 50 Mtrs, 80 GSM). Inspection by CONSIGNEE.
Inkjet mat film Roll 75 micron double matte size 915 X 20 mtrs. Double mattee No-2 inches spool. Inspection by CONSIGNEE.
Servo controlled voltage stabilizer. Capacity: 3KVA 1Ph SCVS; Model :PS 5k 1PH; Type Air cooled; Input Voltage 140-270 V AC; Output Voltage 230V AC+/- 1. Inspection by CONSIGNEE.
Supply of sealed maintanance free battery rechargable VRLA battery of 12v/75 AH make amaraja , exide & panasonic. Inspection by CONSIGNEE.
Maintenance free 12v/7AH battery packs (rechargable) make-amaraja , exide & panasonic. Inspection by CONSIGNEE.
supply of sealed maintenance free battery rechargable VRLA battery of 12v/65AH make amaraja , exide & panasonic. Inspection by CONSIGNEE.
Supply of power supply unit cum battery charger 12V 10Amps (liner type) As per specification enclosed. (BM 100 or similar). Inspection by CONSIGNEE.
Supply of LAN Extender, IP65 Brand: TEAMLINK 3002 SHDSL or similar or better. Inspection by CONSIGNEE.
Supply of Switch Plate lubricant - Cenolube 100 or better NLGI 00 GRADE Black colored which should be non asphaltic Non bituminous blend of very heavy oils, inert thickeners and lubricating solids coupled with molybdenum disulfide and graphite with no traces of chlorinated solvent such as 1,1,1 trichloroethane which are flammable and harmful to the environment. Should have a blend of select high viscosity index solvent refined severely hydrofinished paraffin base oils and synthetic base fluids. It should incorporate solid lubricants & organo molybdenum disulphide to fill & lubricate micronized asperities to provide & form many films on the contact surfaces to prevent metal-tometal contact. It shall be designed to be hand applied providing a tough adherent Lubricant 13 film with Tacky semi-dry finish reducing contaminant adhesion. The grease Should Not form a difficult to remove thick DRY film which requires scrapping & solvent cleaning of Switch Plate specially before reapplication The grease should Not need Cleaning or scrapping before Reapplication. The Grease should be formulated for tropical climates and should not contain pour point depressants and should Not be too thin. The grease shall be Resistant to water wash off & dilution, water insoluble, non-melt and chemically resistant to exposed environment. The grease shall be formulated with Extreme Pressure additives, rust and corrosion inhibitors, anti-wear additives to protect external surfaces against the harsh elements in severe climates, thus reducing rust binding and adhesive wear on switch plates Four Ball Weld LOAD (ASTM- D2596) >600 Kg, Copper corrosion 24 hrs @ 100c (ASTM D 4048) 1a -2e packing Size 20 kg /25kg Drum. Inspection by RITES. Above/
Digging of cable trench to a depth of not less than 30 cm in rocky terrain/difficult terrain Concreting the trench with 150mm thick concrete with 1 cement: 2 sand: 4 graded stone aggregate 20mm nominal size. All the material is to be arranged by contractor.
Jungle Cutting Clearing jungle including uprooting of rank vegetation, grass, brush 05 wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of cleared jungle to a distance of 50 m outside the periphery of the area cleared (Measurement is to be done as per area cleaned).
Track crossing/ Road Crossing by Horizontal Boring method at culverts / track / pucca road as per SCR Drg. No. 5770. This also includes insertion of HDPE pipe of 110 mm/G.I Pipe of 100 mm in the bore drilled (HDPE pipe/ GI pipe is to be supplied by Railway).
Supply and laying of split DWC pipe in already dug cable trenches a s per Drawing No.SK.9/11 .The unit of RMT means two split pipes of 1 Mtr each.
Strengthening of foundations of signals, Full/Half location boxes up to a height of 30 09 cm, by carrying out the earth work around the foundation, ramming of the earth, carry out masonry work from bottom of earth work using country stones and cement masonry to prevent the earth from slipping down the bank. Per
Cable termination including fixing terminals, fuses, LDs, Meggering of cables and recording the readings.
Fixing o f universal point machines a n d wiring on PSC/Wooden sleepers as per 11 standard drawing. Wiring as per circuitry includes fixing & wiring of point contactor unit frames and controlling relays, fixing and wiring o f point termination box, fixing of crank handle ward plate of required configuration and Ground connections, P-clamp insulations, setting, stretcher bars etc., [All miscellaneous material required such as nuts, bolts, washers are to be arranged by contractor] Per Point
Fabrication of Keys and Plate configuration for points
Fixing relay bases, wiring in location boxes, bunching, fixing of relays as per circuit diagram. This includes fixing of condensers, resistance, 6 way / 1 way terminals/ WAGO, N D type fuses, LED indicators for fuses as per type fuses.
Fixing of Track lead junction box on angles (50 x 50 x 6 mm size), drilling one hole on either side of the box of suitable size and fixing track lead junction box by the side of the track, 15 drilling 4 holes of 7.2 mm dia. on Rail, connecting double track leads with bond pins, running track lead wire, termination of track lead wire on ARA terminals duly fixing the same inside the TLJB Teak wood board bolted inside the track lead junction box. (Fixing angles, bolts, nuts and teak wood boards to be supplied by the contractor).
Drilling of four no's of 7.2mm holes, per rail joint on web of the rail , providing bond wires with wire rope. (Bond pins single groves are to be supplied by contractor - Wire rope for bonding will be supplied by Railways). number=per rail joint
Earthing and soldering of the cable armour and connecting to the earth bus bar .as per the Instruction of SSE/SE at Site number=per cable
Transportation of materials from any Stores to Site and vice- versa including loading and unloading. Lead above 50 Kms number=ptpk Above/
B2-Labour Portion (Non-SOR Items) 1719200.00 Below/P
Engagement of Semi skilled labour as per Railway Board Yard stick Ltr No. 01 E(MPP)2021/1/16 dated 28.12.2022 in S&T department for Maintenance of S&T gears like cleaning of batteries, cleaning of ballast & grass near Location box, Signals, Axle counters, Track circuits and point machines ctc. and helping the technician in regular maintenance, Preventive checks and break down maintenance - B area)
Engagement of Semi skilled labour as per Railway Board Yard stick Ltr No. 02 E(MPP)2021/1/16 dated 28.12.2022 in S&T department for Maintenance of S&T gears like cleaning of batteries, cleaning of ballast & grass near Location box, Signals, Axle counters, Track circuits and point machines ctc. and helping the technician in regular maintenance, Preventive checks and break down maintenance -C area)
Engagement of Skilled labour as per Railway Board Yard stick Ltr No. E(MPP)2021/1/16 dated 28.12.2022 in S&T department for Maintenance of S&T gears along with 03 Railway Technician as per schedule to maintain S&T gears like Track circuits, Points, Axle counters, LC gates, Electnonic Interlocking, Panel Interlocking,EC socket testing, Cable path joint survey with RCIL, IB phone, PA system, Surveilance Cameras, FOIS/COIS/TMS, UTS/PRS, IPIS, Control phone, VHF sets, Electronics exhanges, Railnet, OFC Huts battery maintenance, STM & Mux etc. - B area)
Engagement of Skilled labour as per Railway Board Yard stick Ltr No. E(MPP)2021/1/16 dated 28.12.2022 in S&T department for Maintenance of S&T gears along with 04 Railway Technician as per schedule to maintain S&T gears like Track circuits, Points, Axle counters, LC gates, Electnonic Interlocking, Panel Interlocking,EC socket testing, Cable path joint survey with RCIL, IB phone, PA system, Surveilance Cameras, FOIS/COIS/TMS, UTS/PRS, IPIS, Control phone, VHF sets, Electronics exhanges, Railnet, OFC Huts battery maintenance, STM & Mux etc. - C area)
Providing the services of Computer oriented technical manpower to carryout works like drawing, computation, write up etc., using computer, using software like AUTOCAD, MS Office 05 etc., between 08.00 Hrs and 0.00 Hrs of the day with all expenses of transportation, accomodation, food, consumables etc., with all ascents, descents, taxes, octroi, cess, fees, duties with contractors cost etc., as per special conditions/specifications/regulations and as directed by ENgineer-incharge. NOte: the person engaged for providing the services shall be convergent with computer working knowledge in above softwares.
Installation of cenolube 100 Grease. Afetr cleaning of old oil and greece and re- lubrication of switch chair plate at point machine at interval of 15 days per point machine. 06 Tightening of nuts check nuts and bolts lock nuts holding the detector slides lock slides with lugs. Workers are required to check for the tightness of the switch plates and points and clean the rust and dust apply Cenolube 100 grease on slide chaires & assembly up to 3 sleepers from the toe of switch. Rate per person for 3 persons to be deployed for 210 days time, so number of mandays is 3*210=630 days.
Item Breakup - A1-Supply Portion (SOR Items)
8640-4no for LH lock slide. 11. Insulating Plate LH as per DRG.No.S 3404 RDSO/S 3593- 1no. 12. Insulating Plate RH as per DRG.No.S 3404 RDSO/S 3592- 1no. 13. Bush as per DRG.No.S 23199-4no and washer as per DRG.No.S 8640- 4no for RH lock slide. Inspection by RITES." Total 91844.00 Item- 11 Supply of Various Telephones and Telephone Power Supply unit S No. Item Description of Item Unit Qty Rate Amount No
4 wire train traffic control equipment with Numbers DTMF signalling way station equipment and way station control telephone as per specification IRS : TC 60-2007 Amd. 1 or latest. Inspection by CONSIGNEE.
"Desk type 2 wire, 12 way DTMF selective Numbers calling group telephone (Selective Calling / Group Telephone) complete as per specification IRS: TC 80-2000 Amd. 1 or latest with suitable power supply unit. Inspection by CONSIGNEE." 3 1002(c) Push button corded auto telephone with Caller Numbers 10.00 1495.00 14950.00 I D facility of Beetel, Panasonic or Binatone make. Inspection by CONSIGNEE. 4 1002(d) "Supply o f P o w e r Supply U n i t f o r telecom Numbers 5.00 4265.00 21325.00 installations o f 2A output capacity as per specification IRS: TC 72-97 Amd. 1 or latest with 12V / 7AH maintenance free battery. Inspection by CONSIGNEE." Total 95770.00 Item- 12 Supply of GKP type Location Boxes S No. Item Description of Item Unit Qty Rate Amount No 1 201(a) Full size as per drg. No. S&T/MFT/T.2378. Numbers 15.00 16216.00 243240.00 Inspection by RITES. 2 201(b) Half size drg. No. S&T/MFT/T.2378. Inspection Numbers 5.00 8083.00 40415.00 by RITES. Total 283655.00 Item- 21 Supply of OFC Related items S No. Item Description of Item Unit Qty Rate Amount No NANDED DIVISION-S AND T/SOUTH CENTRAL RLY 1 1009(a) Supply o f Permanently lubricated HDPE Duct Kilometre 2.00 66223.00 132446.00 w i t h outer diameter o f 4 0 m m a n d inner d i a m e t e r o f 3 3 m m a s per specification RDSO/SPN/TC/45/2013 Revision 2.0. The length of the duct shall be 1km. Two end plugs shall be provided along with the drum. Inspection by RITES. 2 1009(b) Supply of Plastic couplers - Slip fit / push type Numbers 10.00 85.00 850.00 for permanently lubricated HDPE duct. Inspection by RITES. 3 1009(c) Supply of End plug for permanently lubricated Numbers 10.00 34.00 340.00 HDPE duct. Inspection by RITES. 4 1009(d) Supply of Cable sealing plugs for permanently Numbers 10.00 43.00 430.00 lubricated HDPE duct. Inspection by RITES. 5 1009(e) "Supply of Rotary duct cutter suitable for Numbers 2.00 1046.00 2092.00 cutting HDPE ducts of diameter 20mm to 42mm. The duct cutter shall have a facility of replaceable blades. The blades shall be of high carbon steel." Inspection by CONSIGNEE. Total 136158.00
Item Breakup - B1-Labour Portion (SOR Items)
Laying different type of cables in the trench. RMT Termination covered elsewhere. 2 2509(B) Meggering o f c a b l e l a i d , b e f o r e a n d after Numbers 200.00 319.00 63800.00 laying (before closing of trench). number=per cable 3 2509(C) Meggering of cable already terminated. Numbers 200.00 85.00 17000.00 number=per cable Total 255800.00 Supply and laying of split DWC pipe in already dug cable trenches as per Drawing No.SK.9/11 .The Item- 08 unit of RMT means two split pipes of 1 Mtr each. S No. Item Description of Item Unit Qty Rate Amount No
120/103 CONSIGNEE.
250/217 CONSIGNEE. Total 122500.00 Item- 13 Fabrication of Keys and Plate configuration for points S No. Item Description of Item Unit Qty Rate Amount No 1 3221(A) Fabrication, fixing of required configuration of Numbers 74.00 319.00 23606.00 key for point machine for grouping of crank handle. NANDED DIVISION-S AND T/SOUTH CENTRAL RLY 2 3221(B) Fabrication, fixing of required configuration of Numbers 74.00 563.00 41662.00 grouping plate in point machine for grouping of crank handle. Total 65268.00
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Drawings.pdf
ATTACHMENT
2026_06_22_Tender_Document_2025_MMR_MUE_TRR_74_Sets.pdf Tender Document
ATTACHMENT
2026_06_22_Tender_Document_2025_MMR_MUE_TRR_74_Sets.pdf
ATTACHMENT
Download all tender documents and submit your bid