Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹3.5 L
Closing Date
1 Dec 2026, 5:30 pm4d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
MR Kamlesh Thakur(DFLT)
MUNICIPAL CORPORATION, DHAMTARI
Rejuvenation of Water body including ecological restoration and public amenities with five (05) years Operation and Maintenance in Makai Talab, Dhamtari, Chhattisgarh under AMRUT 2.0
202556
17/23.10.2026
RESTRICTED TENDER
WORKS
PERCENTAGE
12 days
MUNICIPAL CORPORATION
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
14 documents required · 14 mandatory
Urban Administration and Development Department (UADD)
WORKS
MR Kamlesh Thakur(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B
MUNICIPAL CORPORATION, DHAMTARI
TENDER SECTION
COMMISSINOR, MUNICIPAL CORPORATION, DHAMTARI
365
12
No
0
202556
19 Nov, 2026 5:30:00 PM IST
26 Nov, 2026 11:00:00 AM IST
24 Oct, 2026 5:30:00 PM IST
17/23.10.2026
Rejuvenation of Water body including ecological restoration and public amenities with five (05) years Operation and Maintenance in Makai Talab, Dhamtari, Chhattisgarh under AMRUT 2.0
347000.00 INR
Fixed Deposit Receipt (OFFLINE)
2
25 Nov, 2026 5:30:00 PM IST
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
26d 1h 31m
14 documents required · 14 mandatory
₹0
₹3.5 L
1 Dec 2026
24 Oct 2026
7 Dec 2026
24 Oct 2026
4 Dec 2026
365 days
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
All rates are as per Schedule of rate in C.G. P.W.D. in forced from 10.06.26 Building Sor, Road SOR 15.06.26, Ele. Sor 10.06.2026 & CG P.H.E.D -U.S.O.R 2020, AMENDMENT NO-07/2022-23, 09/2023-24 & CG WRD SOR 2025 up to date amendments.
S.NO. PARTICULARS AMOUNT PAC
As Per Sor Non Sor
1 BUND PREPARATION WORK 1457295.87 1457295.87
2 CONSTRUCTION WORK OF STONE TOE WALL 4231267.78 4231267.78
3 CONSTRUCTION WORK OF RCC RETAINING WALL 1053950.00 1053950.00
4 CONSTRUCTION WORK OF STONE PITCHING 3555932.12 3555932.12
5 CONSTRUCTION WORK OF GHAT (4 NOS.) 5053829.22 5053829.22
6 CONSTRUCTION OF PATHWAY 2995197.16 2995197.16
7 CONSTRUCTION OF PARKING 1269575.98 1269575.98
8 LANDSCAPING WORK 506983.83 506983.83
9 CONSTRUCTION OF MS GRILL BOUNDARY WALL 4445434.41 4445434.41
10 CONSTRUCTION OF BRICK BOUNDARY WALL 1517875.68 1517875.68
11 CONSTRUCTION OF FRONT MS GRILL BOUNDARY WALL 280348.30 280348.30
12 PAINTING WORK ON EXISTING MS GRILL (AROUND ISLAND) 45972.86 45972.86
13 HUME PIPE WORK FOR INLET 477166.65 477166.65
14 HUME PIPE WORK FOR OUTLET 477166.65 477166.65
15 WATER SUPPLY WORK FOR LANDSCAPE 192501.00 192501.00
16 CONSTRUCTION WORK OF RCC DRAIN 3855664.30 3855664.30
17 CONSTRUCTION WORK OF MAIN ENTRANCE GATE & GLOW SIGN BOARD (GATE -01) 310968.51 310968.51
18 CONSTRUCTION WORK OF SIDE SMALL ENTRANCE GATE & GLOW SIGN BOARD (GATE 02 & 03 ) 271954.66 271954.66
19 CONSTRUCTION WORK OF BOREWELL 264568.00 264568.00
20 CONSTRUCTION WORK OF TOILET 492373.71 492373.71
21 CONSTRUCTION WORK OF SEPTIC TANK 91307.74 91307.74
22 SOLAR LIGHTS ALONG PATHWAYS 3361792.24 3361792.24
23 CONSTRUCTION OF YOGA CHABUTARA 517096.86 517096.86
24 SOLAR PANELS FOR OTHER POWER REQUIREMENTS- TOILETS, SHOPS, ETC. 287925.00 287925.00
25 CC. TV. CAMERA ( SOR ITEMS) 363172.00 363172.00
26 WATER COOLER (2 NOS.) 121299.00 121299.00
27 REHABILITATION OF COMMERCIAL SPACE FOR SHOP 518652.37 518652.37
28 DIRECTION & PLACE SIGNAGE 27330.84 27330.84
30 CONSTRUCTION WORK OF TEMPLE 420728.30 420728.30
31 SLUICE GATES AT INLET & OUTLET 549904.00 549904.00
B WATER REMEDIATION SOLUTION
32 DESILTING & POND CLEARANCE 8628848.52 8628848.52
32(A) CONSTRUCTION WORK OF STP MBBR PACKAGED TECHNOLOGY (200 KLD) (AS PER MP PWD BUILDING SOR VOL. II, 01.01.2024) 6354750.00 6354750.00 1143855.00
32(B) CONSTRUCTION WORK OF STP MBBR PACKAGED TECHNOLOGY (10 KLD) (AS PER MP PWD BUILDING SOR VOL. II, 01.01.2024) 1968323.00 1968323.00
33 BATHYMETRY SURVEY 229405.00 229405.00
34 VETIVER PLANTS 836910.00 709245.76
35 FLOATING WETLAND 5060000.00 4288135.59
TOTAL (B) 8858253.52
36 3D ARTISTIC PAINTING 481595.4 408131.69
37 KIDS PLAY EQUIPMENT & GYM EQUIPMENT 461473.74 391079.44
38 SEATING BENCH 224000.00 189830.51
39 OUTDOOR DUSTBIN 104000.00 88135.59
40 FLOTING AERATORS 1485000.00 1258474.58
42 CC. TV. CAMERA (NON SOR ITEMS) 154934.00 131300.00
43 SOLAR PANEL AMENITIES 137470.00 116500.00
TOTAL NON SOR (C) 19141256.14
E 18% GST FOR SOR ITMES (A + B + S.NO. 32 ) 10143765.64
F Total Construction Cost incl. GST (D + E) 77316202.34
G CONTINGENCY & CONSULTANCY FEE @ 2.50% OF (D) 1343448.73
H Total CAPEX (F + G) 78659651.07
I 5-year OPERATIONS & MAINTENANCE 3874905.00 3874905.00
In Word : Eight Crore Twenty-Five Lakh Thirty-Four Thousand Only (35.73)
S. No. Component Amount with 18 % GST Weightage
1 Rejuvenation 53554490.05 69.27%
2 Beautification 11541750.16 14.93%
3 Public Amenities 12219962.13 15.81%
CONTINGENCY & CONSULTANCY FEE @ 2.50% 1343448.73 277.59
Grand Total 78659651.07
S.no. Component Name Amount
1 Construction Cost 65522205.37
E.E. A.E. SUB .E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REPORT AND SPECIFICATION
Name of Work : REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
Estimated cost : Rs.82534000 : [Rs. Eight Crore Twenty Five Lakh Thirty Four Thousand Only ]
Administrative Approval :
Necessity to Construct & Renovate :
Provision : Following provision have been made in this Building.
1 Foundation : (i) As foundation PCC 1:3:6 are provided below column footing & in sub-base.
(ii) R.C.C. nominal mix 1:11/2: 3 as required.
2 Structure : (i) Stone Toe Wall
(ii) Stone Pitching
3 Under Floor : (i) Stuff, Sand/ Crusher dust & hard Moorum filling has been taken in estimate.
4 Flooring : (i) Kota, Vitrified tiles,Ceramic has been taken in Respective floors
5 Steel Work : (i) MS Grills has been taken for Boundary wall
6 Windows : (i) Aluminium Windows has been taken.
7 Doors : (i) Laminated Flush door has been taken with all fittings.
8 Roofing : (i) For roofing Sheet galvalume sheet has been taken.
9 Plastering : (i) 12mm thick plaster for smooth side, 15mm thick plaster for rough side, 15mm thick plaster for outer walls.
10 Painting : (i) Outer and Inner paints has been taken as suitable.
11 Rate : All rates are as per Schedule of rate in C.G. P.W.D. in forced from 10.06.26 Building Sor, Road SOR 15.06.26, Ele. Sor 10.06.2026 & CG P.H.E.D -U.S.O.R 2020, AMENDMENT NO-07/2022-23, 09/2023-24 & CG WRD SOR 2025 up to date amendments.
E.E. A.E. Sub.E. ARCHITECT
AR. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
All rates are as per Schedule of rate in C.G. P.W.D. in forced from 10.06.26 Building Sor, Road SOR 15.06.26, Ele. Sor 10.06.2026 & CG P.H.E.D -U.S.O.R 2020, AMENDMENT NO-07/2022-23, 09/2023-24 & CG WRD SOR 2025 up to date amendments.
S.NO. PARTICULARS AMOUNT
As Per Sor Non Sor
1 BUND PREPARATION WORK 1457295.87
2 CONSTRUCTION WORK OF STONE TOE WALL 4231267.78
3 CONSTRUCTION WORK OF RCC RETAINING WALL 1053950.00
4 CONSTRUCTION WORK OF STONE PITCHING 3555932.12
5 CONSTRUCTION WORK OF GHAT (4 NOS.) 5053829.22
6 CONSTRUCTION OF PATHWAY 2995197.16
7 CONSTRUCTION OF PARKING 1269575.98
8 LANDSCAPING WORK 506983.83
9 CONSTRUCTION OF MS GRILL BOUNDARY WALL 4445434.41
10 CONSTRUCTION OF BRICK BOUNDARY WALL 1517875.68
11 CONSTRUCTION OF FRONT MS GRILL BOUNDARY WALL 280348.30
12 PAINTING WORK ON EXISTING MS GRILL (AROUND ISLAND) 45972.86
13 HUME PIPE WORK FOR INLET 477166.65
14 HUME PIPE WORK FOR OUTLET 477166.65
15 WATER SUPPLY WORK FOR LANDSCAPE 192501.00
16 CONSTRUCTION WORK OF RCC DRAIN 3855664.30
17 CONSTRUCTION WORK OF MAIN ENTRANCE GATE & GLOW SIGN BOARD (GATE -01) 310968.51
18 CONSTRUCTION WORK OF SIDE SMALL ENTRANCE GATE & GLOW SIGN BOARD (GATE 02 & 03 ) 271954.66
19 CONSTRUCTION WORK OF BOREWELL 264568.00
20 CONSTRUCTION WORK OF TOILET 492373.71
21 CONSTRUCTION WORK OF SEPTIC TANK 91307.74
22 SOLAR LIGHTS ALONG PATHWAYS 3361792.24
23 CONSTRUCTION OF YOGA CHABUTARA 517096.86
24 SOLAR PANELS FOR OTHER POWER REQUIREMENTS- TOILETS, SHOPS, ETC. 287925.00
25 CC. TV. CAMERA ( SOR ITEMS) 363172.00
26 WATER COOLER (2 NOS.) 121299.00
27 REHABILITATION OF COMMERCIAL SPACE FOR SHOP 518652.37
28 DIRECTION & PLACE SIGNAGE 27330.84
29 TREE GUARD 157692.00
30 CONSTRUCTION WORK OF TEMPLE 420728.30
31 SLUICE GATES AT INLET & OUTLET 549904.00
B WATER REMEDIATION SOLUTION
32 DESILTING & POND CLEARANCE 8628848.52
32(A) CONSTRUCTION WORK OF STP MBBR PACKAGED TECHNOLOGY (200 KLD) (AS PER MP PWD BUILDING SOR VOL. II, 01.01.2024) 6354750.00 1143855.00
32(B) CONSTRUCTION WORK OF STP MBBR PACKAGED TECHNOLOGY (10 KLD) (AS PER MP PWD BUILDING SOR VOL. II, 01.01.2024) 1968323.00
33 BATHYMETRY SURVEY 229405.00
34 VETIVER PLANTS 836910.00
35 FLOATING WETLAND 5060000.00
TOTAL (B) 8858253.52
36 3D ARTISTIC PAINTING 481595.4
37 KIDS PLAY EQUIPMENT & GYM EQUIPMENT 461473.74
38 SEATING BENCH 224000.00
39 OUTDOOR DUSTBIN 104000.00
40 FLOTING AERATORS 1485000.00
41 VENDOR SHOP 1872800.00
42 CC. TV. CAMERA (NON SOR ITEMS) 154934.00
43 SOLAR PANEL AMENITIES 137470.00
TOTAL NON SOR (C) 19141256.14
D SUB TOTAL (A+B+C) 67172436.70
E 18% GST FOR SOR ITMES (A + B + S.NO. 32 ) 10143765.64
F Total Construction Cost incl. GST (D + E) 77316202.34
G CONTINGENCY & CONSULTANCY FEE @ 2.50% OF (D) 1343448.73
H Total CAPEX (F + G) 78659651.07
I 5-year OPERATIONS & MAINTENANCE 3874905.00
In Word : Eight Crore Twenty Five Lakh Thirty Four Thousand Only (35.73)
S. No. Component Amount with 18 % GST Weightage
1 Rejuvenation 53554490.05 69.27%
2 Beautification 11541750.16 14.93%
3 Public Amenities 12219962.13 15.81%
CONTINGENCY & CONSULTANCY FEE @ 2.50% 1343448.73
Grand Total 78659651.07
E.E. A.E. SUB .E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
BUND PREPARATION WORK
AS PER ROAD S.O.R. 15.06.26
SN REF ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
1 3.14 road sor Construction of Embankment with Material Deposited from Roadway Cutting (Construction of embankment with approved materials having C.B.R.>5 (unless specified otherwise in the contract) deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-2)
Pond Excavated 70% Soil Used In Bund Prepration Work
Pond Excavated Qty. 29740.73 x 70% = 20818.51 cum 20818.51
TOTAL 1457295.87
E.E. A.E. SUB.E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
CONSTRUCTION WORK OF STONE TOE WALL
AS PER BUILDING S.O.R. 10.06.26
SN REF ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
1 1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.
1.1.1 In all types of soil
( i ) Inner Side Toe wall
2 1.17 Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M.
( i ) Inner Side Toe wall
Qty Same As Excavation- 1253.77
PCC below G.L. 1 X 156.72 156.72
Stone masonry below G.L. 1 X 783.61 783.61
3 3.1 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
( i ) Inner Side Toe wall
4 6.1 Random rubble masonry with hard stone in foundation and plinth in Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand: 12 stone aggregate 20mm nominal size) upto plinth level.
Stone Masonry Below G.L.-
5 6.1 + 6.2 Extra for random rubble masonry with hard stone in superstructure above plinth level for every floor or part hereof in addition to rate for foundation and plinth: 2138 + 173 = 2311 /-
Above ground lvl
6 3.1 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.1.5 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
7 2.1 Providing and fixing form work including centring, shuttering, strutting,staging, propping bracing etc. complete and including its removal at all levels, for:
2.1.8 Beams, lintels, cantilevers & walls
PCC Work Above Toe Wall (1 x 2)
8 11.38 Providing and making pointing on stone work with cement Mortar 1:3 (1cement : 3 fine sand)
11.38.3 Raised and cut pointing
TOTAL 4231267.78
E.E. A.E. Sub E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
CONSTRUCTION WORK OF RCC RETAINING WALL
AS PER BUILDING S.O.R. 10.06.26
SN REF ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
1 1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.
1.1.1 In all types of soil
i) For RCC Retaining wall Footing 1 83.25 2.10 1.00 174.83
2 1.17 Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M.
Qty Same As Excavation- 174.83
Pcc below G.L. 17.48
Rcc below G.L. 57.44
Total A-B 99.90 CUM 55.00 5494.50
Remaining Earth after Retaining Wall filling 74.93 CUM
3 3.1 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
i) Below Footing 1 83.25 2.10 0.10 17.48
4 3.2 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. (Note :Excess/ less cement used as per design mix is payable/ recoverable separately)
3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
For RCC Retaining Wall - Footing To G.L. 1 83.25 0.25 0.60 12.49
RCC Retaining Wall Top = 0.20 m. Th.
RCC Retaining Wall Bottom = 0.30 m. Th.
Avg Thk. Of RCC Retaining Wall = (0.20 + 0.30) / 2 = 0.25 m.
Retaining Wall Above G.L. 1 83.25 0.25 2.40 49.95
5 3.12 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending etc. complete as per drawing including cost of binding wire. All complete.
3.12.2 Thermo-Mechanically treated bars FE 500D
assuming 100 kg per cum of Concrete 1 107.39 x 100.00 10739.25 Kg 46.00 494005.50
6 2.1 Providing and fixing form work including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for:
2.1.1 Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.
7 2.1.2 Wall of any thickness including attached pilasters, buttresses etc. in super structure.
RCC Retaining Wall ( Abow Footing ) 2 83.25 3.00 499.50
Total 1053950.00
E.E. A.E. Sub E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
CONSTRUCTION & REPAIRING WORK OF STONE PITCHING
AS PER BUILDING 10.06.26 & ROAD S.O.R. 15.06.26
SN REF ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
1 9.10 ROAD SOR Providing and laying Pitching Stone/Boulder on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications as per clause 2504.
Stone Pitching - 1 1 75.32 4.50 0.30 101.68
Stone Pitching - 2 1 91.25 4.50 0.30 123.19
Stone Pitching - 4 1 84.02 4.50 0.30 113.43
Stone Pitching - 5 1 81.71 4.50 0.30 110.31
Deduction of separator beam 199 0.20 4.50 0.30 53.73
2 9.11 ROAD SOR Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification including trimming of slopes to proper profile and preparation of bed and as per clause 2504.
Stone Pitching - 1 1 75.32 4.50 0.15 50.84
Stone Pitching - 2 1 91.25 4.50 0.15 61.59
Stone Pitching - 4 1 84.02 4.50 0.15 56.71
Stone Pitching - 5 1 81.71 4.50 0.15 55.15
Stone Pitching - 6 1 138.79 4.50 0.15 93.68
Stone Pitching - 7 1 116.38 4.50 0.15 78.56
Deduction of separator beam 199 0.20 4.50 0.15 26.87
3 3.1 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.1 3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
Pcc Base Below Beam
Beam For Pitching in every 4.00 m.
Stone Pitching - 1
Stone Pitching - 2
Stone Pitching - 3
Stone Pitching - 4
Stone Pitching - 5
Stone Pitching - 6
Stone Pitching - 7
4 3.2 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. (Note :Excess/ less cement used as per design mix is payable/ recoverable separately)
3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
Beam For Pitching in every 4.00 m.
Stone Pitching - 1
Stone Pitching - 2
Stone Pitching - 3
Stone Pitching - 4
Stone Pitching - 5
Stone Pitching - 6
Stone Pitching - 7
5 3.12 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending etc. complete as per drawing including cost of binding wire. All complete.
3.12.2 Thermo-Mechanically treated bars FE 500D
Qty. same as RCC of Beam 1 x 53.73 53.73
5 2.1 Providing and fixing form work including centring, shuttering, strutting,staging, propping bracing etc. complete and including its removal at all levels, for:
2.1.8 Beams, lintels, cantilevers & walls
Form Work for Pitching Beam
Beam For Pitching in every 4.00 m.
Stone Pitching - 1
Stone Pitching - 2
Stone Pitching - 3
Stone Pitching - 4
Stone Pitching - 5
Stone Pitching - 6
Stone Pitching - 7
TOTAL 3555932.12
E.E. A.E. Sub E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
CONSTRUCTION OF GHAT
AS PER BUILDING S.O.R. 10.06.26
SN REF ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
1 1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.
1.1.1 In all types of soils.
Toe wall in front of ghat 1 30.40 1.10 0.70 23.41
2 1.18 Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete.
Filling Below Steps 1 area 2.61 28.80 75.17
Filling for toe wall 1 30.40 1.10 0.70 23.41
Stoe Toe Wall 27.00
Toe wall pcc base 3.34
3 3.1 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.1 3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
Pcc Base for steps 5 28.80 0.90 0.10 12.96
Pcc Base for side stone walls, 7 x 2 14 0.80 0.90 0.10 1.01
Pcc Base for toe wall 1 30.40 1.10 0.10 3.34
3.2 3.1.4 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size).
Pcc Coping on both side stone wall top 7 X 2 14 0.90 0.60 0.10 0.76
3.3 3.1.5 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
4 2.1 Providing and fixing form work including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for:
2.1.1 Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.
For PCC Steps both side 7 X 2 14 28.80 0.20 80.64
Pcc Coping on stone wall top (both side both wall) 2 x 7 x 2 28 0.90 0.10 2.52
Pcc Coping on srone wall top (Front side both wall) 2 x 7 X 1 14 0.60 0.10 0.84
5 6.1 Random rubble masonry with hard stone in foundation and plinth in Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand: 12 stone aggregate 20mm nominal size) upto plinth level.
stone masonry side wall
both side of steps 7 X 2 14 0.90 0.60 1.50 11.34
6 9.57 Providing stainless steel railing/ grill made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design fixing in stair case, balcony or other places with metal fasteners and stainless steel bolts etc complete.
9.57.2 SS Grade 304
Both Side & Mide 3 6.85 0.90 18.50
asuming 10.50 kg per sqm. 10.50 x 18.50 194.20
7 11.38 Providing and making pointing on stone work with cement Mortar 1:3 (1 cement : 3 fine sand)
11.38.3 Raised and cut pointing
stone masonry side walls
Inner side (both side Walls) 7 X 2 14 0.90 0.60 7.56
Outer side (both side Walls) 7 X 2 14 0.90 1.15 14.49
front side (both side Walls) 7 X 2 14 0.60 0.60 5.04
8 12.57 25mm thick Local RAJIM/ Red Flag stone slab in riser of steps, skirting, dado and pillars laid on 12mm (Average) thick cement mortar 1:4 (1 cement : 4 coarse sand) and joint with grey cement slurry mixed with pigments to match the shade of the slab i/c grinding, rubbing and polishing.
Cost For 1 Ghat Total ( A ) 614350.71
B SHED COVERING
9 1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.
1.1.1 In all types of soils.
10 3.1 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
11 3.2 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. (Note :Excess/ less cement used as per design mix is payable/ recoverable separately)
3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
Column up to G.L.
Column Above GL. 14 0.30 0.30 0.60 0.76
12 3.12 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire all complete:
3.12.2 Thermo-Mechanically treated bars FE 500D
13 2.1 Providing and fixing form work including centering, shuttering, strutting,staging, propping bracing etc. complete and including its removal at all levels, for:
13.1 2.1.1 Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.
Column up to G.L.
Column Above GL.
14 9.3 Steel work in tubular (round, square or rectangular hollow tubes etc.) structure in built-up sections, trusses and frame work including cutting, hoisting, fixing in position upto a height of 5m above plinth level, consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer.
9.3.2 Electric resistance or induction butt welded tubes Grade-300
Vertical main Rafte NB - 100 (H) @ 14.50 kg/m 7 6.00 x 14.50 609.00
MAIN RAFTER NB - 80 (H) @9.9 kg/m
TRUSS MEMBER NB - 50 (H) @6.19 kg/m
Add 10 % For base plate, gusset plate, nut - bolts & other fitting items 462.73
15 10.12 Supply and fixing of polymer precoated galvalume profile sheets (PPGL) of approved size, shape and pitch of corrugation, total coated thickness (TCT) 0.60 mm +/- 5%, epoxy primer on both side of the sheet and colour polyester top coat 18-20 microns and 6-7 microns on bottom. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal or with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Truss Roof 1 31.20 7.82 243.98
16 14.72 Providing and applying Glossy finish Enamel paint mimimum 2 coats in all surface applying @ 0.75 lit/ 10 Sqm up to required finish as per relevent I.S. code 2932 : 2013 of (Product such as Asian Apcolite Premium Enamel , Dulux Promise Premium Enamel , Nerolac Synthatic Enamel, Opus Prime enamel ) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackle and labour etc. complete for the work.
Vertical main Rafte NB - 100 (H) @ 14.50 kg/m 7 6.00 0.314 13.19
MAIN RAFTER NB - 80 (H) @9.9 kg/m
TRUSS MEMBER NB - 50 (H) @6.19 kg/m 7 16.42 0.157 18.05
Cost For 1 Ghat Total ( B ) 649106.59
Cost For 4 Ghat G. TOTAL 5053829.22 5053831.572
E.E. A.E. Sub.E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
CONSTRUCTION OF PATHWAY
AS PER BUILDING S.O.R. 10.06.26
SN REF NO. ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
1 16.36 Dismantling terrazzo or mosaic or glazed vitreous or patent cement or tiled flooring or dado skirting of any thickness without sub base.
Entrance Lobby 1 Area 131.88 131.88
Pond Island Paver 1 120.00 3.40 408.00
Circular Area 1 Area 887.37 887.37
2 3.1 Providing and laying nominal mix cement concrete with crushed stone aggregate using concrete mixer in foundation, plinth and at ground level excluding cost of form work.
3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
Pcc Base For Paver
Entrance Lobby 1 Area 131.88 0.10 13.19
Circular Area 1 Area 887.37 0.10 88.74
Open Gym Area 1 Area 242.46 0.10 24.25
Yoga Chabutra Area 1 Area 71.67 0.10 7.17
Around temple 1 Area 261.70 0.10 26.17
Toilet Area 1 Area 35.37 0.10 3.54
3 1.18 Providing and filling in plinth with sand / Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc.complete.
Sand In Kid's Play Area
Kid's Play 01 1 Area= 383.28 0.30 114.98
Kid's Play 02 1 Area= 463.59 0.30 139.08
Kid's Play 03 1 Area= 167.75 0.30 50.33
4 12.37 Chequered precast cement concrete tiles 22mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tile including cleaning of joint etc complete on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) :
12.37.1 Light shade using white cement
Open Gym Area 1 Area 242.46 242.46
Yoga Chabutra Area 1 Area 71.67 71.67
5 12.65 Providing & laying 60mm thick precast interlocking concrete blocks of approved size (approx 305 sqcm) and shape/ pattern, over 40 mm thick average complete coarse sand bed with joints of 3mm thick filled by fine sand including leveling with surface vibrator, temping and sweeping etc. complete of minimum compressive strength of 250 kg/sq.cm
12.65.2 Pigment Coloured (rubber mould) precast interlock concrete blocks
Entrance Lobby 1 Area 131.88 131.88
Pond Island Paver
Circular Area 1 Area 887.37 887.37
Around temple 1 Area 118.08 118.08
Around temple 1 Area 261.70 261.70
Toilet Area 1 Area 35.57 35.57
Path 02 1 Area 40.71 40.71
6 3.1 Providing and laying nominal mix cement concrete with crushed stone aggregate using concrete mixer in foundation, plinth and at ground level excluding cost of form work.
6.1 3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
Pcc Base Below RCC Edge
Both side of central path
Around Cricular Path
Inner Kids play
Between Temple area & Kids play Area
Kids Play Area to Plantation 02
7 3.2 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. (Note :Excess/ less cement used as per design mix is payable/ recoverable separately)
3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
Both side of central path
Inner Kids play
8 3.12 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete:
3.12.2 Thermo-Mechanically treated bars FE 500D
Qty. same as RCC of Beam 1 x 59.73 59.73
8 2.1 Providing and fixing form work including centring, shuttering, strutting,staging, propping bracing etc. complete and including its removal at all levels, for:
2.1.8 Beams, lintels, cantilevers & walls
Both side of central path
Inner Kids play
TOTAL (A+B) 2995197.16
E.E. A.E. Sub E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
CONSTRUCTION OF PARKING
AS PER ROAD S.O.R. 15.06.26
SN REF NO. ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
1 3.13 Construction of sub-grade with Material Obtained from Borrow Pits/Borrow Area Construction of sub-grade with approved material/selected soil having C.B.R. > 8 (unless specified otherwise in the contract) obtained from borrow pits/borrow area with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2
Pcc Base For Paver
Parking 01 1 Area 469.17 0.30 140.75
Parking 02 1 Area 332.57 0.30 99.77
2 6.3 Providing and laying cement concrete for plain concrete/ reinforced concrete i/c form work, shuttering complete in as per drawings and specifications.( For Village roads )
(i) P.C.C. M-10
Parking 01 1 Area 469.17 0.10 46.92
Parking 02 1 Area 332.57 0.10 33.26
3 6.4 Providing and laying Un-reinforced Cement Concrete without Dowel bars including formwork and expansion, contraction & longitudinal joints as per design and as per IRC-62, over a prepared base a per approved mix design and finising to lines and grade as per Drawing for Pavement thickness less than 200mm in Low Volume Roads. With Cement concrete grade M-30 and minimum cement content @ 375 kg/cum
Parking 01 1 Area 469.17 0.30 140.75
Parking 02 1 Area 332.57 0.30 99.77
4 4.18 Providing and fixing guard stones 200 x 200 x 900 mm made of precast RCC M20 grade fixed at 300 mm into the ground in P.C.C. 1:3:6 blocks of size 400 x 400 x 400 mm and given two coats of paint with white and black bands including excavation.
RCC Guard Stone 20 20.00
TOTAL 1269575.98
E.E. A.E. Sub E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
LANDSCAPING WORK
AS PER BUILDING S.O.R. 10.06.26 & ROAD S.O.R. 15.06.26
SN REF NO. ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
1 22.2 Supplying and stacking of good earth at site including royalty, loading, unloading and carriage upto 5 km (earth measured in stacks will be reduced by 20% for payment).
Plantation 02 1 Area 133.10 0.45 59.90
Along Island path
Hedge Around Inner Kids play
Hedge Around Island GYM Area
Hedge Around Yoga Chabutra
2 22.3 Supplying and stacking sludge at site including royalty, loading, unloading and carriage upto 5 km (sludge measured in stacks will be reduced by 8% for payment).
3 22.4 Supplying and stacking at site well decayed cow dung manure from approved source, including loading, unloading and carriage upto 5 km (manure measured in stacks will be reduced by 8% for payment).
4 22.5 Rough dressing the trenched ground including breaking clods.
5 22.8 Spreading of sludge, dump manure or/and good earth in required thickness (Cost of sludge, dump manure or/ and good earth to be paid separately).
Pocket landscapings
6 22.9 Mixing earth and sludge or manure in proportion specified or directed.
Landscapings in Pockets
7 22.13 Preparation of beds for hedging and shrubbery by excavating 60cm deep and trenching the excavated base to a further depth of 30cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50m lift upto 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately).
Plantation 02 1 Area 133.10 0.45 59.90 133.10
Along Island path
Hedge Around Inner Kids play
Hedge Around Island GYM Area
Hedge Around Yoga Chabutra
8 22.25 Providing and planting following herbs in garden including preparation of soil, base plantation, providing and spreading different fertilizers, soil and sand:
8.1 22.25.1 Hedges like Alife, Dorenta, Tikoma etc 1 9067.00 9067.00 Each 12.00 108804.00
8.2 22.25.2 Furn like Arica, China etc (3 year old) 1 250.00 250.00 Each 106.00 26500.00
8.3 22.25.3 Hibiscus (Flower)/ Rose 1 500.00 500.00 Each 23.00 11500.00
9 22.10 Grassing with ‘Doob’ grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for mowing including supplying good earth if needed (the good earth shall be paid for separately).
22.10.3 In rows 5 cm apart in either direction.
9 RS. 12.6 Providing and planting of 3’0” to 4’0” heighted wasingtonia, filipheria/bismarkia novelist plam plants with 1’6” x 1’6” depth pit formation and soil preparation, (Mixing organic manure and plant’s protection insecticide). Up to 4 month maintenance. 34 Each 755.00 25670.00
10 RS. 12.7 Providing and planting of 4’0” to 5’0” heighted Ficus prestige/Blackiana plants with 1’6” x 1’6” depth pit formation and soil preparation, (Mixing organic manure and plant’s protection insecticide). Up to 4 month maintenance. 34 Each 533.00 18122.00
Total 506983.83
E.E. A.E. Sub E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
CONSTRUCTION OF MS GRILL BOUNDARY WALL
AS PER BUILDING S.O.R. 10.06.26
SN REF ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
1 15.5 Boring, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in cement concrete 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size), to carry a safe working load, excluding the cost of steel reinforcement but including the cost of boring with auger by manual means and making one bulb using suitable bulb enlarging tool by MANUAL MEANS with all instruments and arrangements required for boring true to vertical line etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap):
15.5.2 300 mm dia piles.
Pile For Fencing Boundary wall
Pile in Every 3.00 M.
2 1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.
1.1.1 In all types of soils.
3 3.1 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
Pcc Base For Pile Cap 274 0.90 0.90 0.10 22.19
4 3.2 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. (Note :Excess/ less cement used as per design mix is payable/ recoverable separately)
3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
Columm - Pile Cap To Bund Lvl 274 0.20 0.30 0.90 14.80
Pile Cap in Ground Beam 274 0.60 0.20 0.30 9.86
5 3.2.1 + 3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 3539.00 + 83.00
Column Above Bund Lvl. 274 0.20 0.30 1.50 24.66
Deduct Column Area In Tie Beam 274 0.20 0.30 0.15 2.47
5 3.12 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete:
3.12.2 Thermo-Mechanically treated bars FE 500D
Qty beam Rcc 130.52
qty = 90 kg/cum of conc. 15408.88 kg 46.00 708808.36
6 2.1 Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for:
6.1 2.1.1 Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.
Ground Beam 1 820.01 0.30 246.00
Pile Cap in Ground Beam 274 0.60 0.30 49.32
6.2 2.1.5 Columns, Pillars, Piers and likes- rectangular or square in shape
6.3 2.1.8 Beams, lintels, cantilevers & walls
Multiplying x2 for sides
Deduct Column Area In Beam 274 0.30 0.15 12.33
7 7.5 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in:
7.5.4 Cement Mortar 1:6 (1 cement : 6 coarse sand)
Brick work Below Ground Beam 1 820.01 0.20 0.10 16.40
Pile Cap in Ground Beam 274 0.60 0.20 0.10 3.29
8 7.5 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in:
7.5.4 Cement Mortar 1:6 (1 cement : 6 coarse sand)
7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 2774.00 +103.00
Column in Brick Work 274 0.20 0.30 0.75 12.33
8 9.6 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer.
9.6.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Ms Grill Boundary Wall 1 820.01 1.50 1230.02
Deduct Column Area 274 0.30 1.50 123.30
9 11.3 Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix:
11.3.4 In Cement Mortar 1:6 (1 cement : 6 fine sand)
Boundary Wall Outer Side 1 820.01 1.20 984.01
Boundary Wall Inner Side 1 820.01 0.90 738.01
10 14.56 Providing and applying 2mm thick white cement based polymeric Exterior grade Putty with minimum 3 coats applied @ 5.4 kg/ 10Sqm as per relevant IS code 17545 :2021 (Product such as Birla wall care, Asian trucare, JK wall putty, Berger Bison wall putty) to make the surface smooth and even with all tools tackles and labour etc. complete for the work.
Qty. same as 15 mm plaster 1 2297.02 2297.02
11 14.68 Providing and applying on exterior surface with PREMIUM Exterior emulsion paint of required shade to give protective and water proof finish minimum 3 coats applied @ 1.40 lit / 10Sqm up to final finish as per relevant I.S. Code 15489 :2013 Type -2 Class D , C (Glossy /Semi Glossy finish ) (Product such as Asian Apex , Dulux Weather Shield Prima E900 , Berger Weathercoat Antidust , Nerolac Everlas Excel , Nippon Sumo Etra, Opus True flex) inclusive of providing abro tape on edges and articleand cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work.(With 3Year Warranty.)
Same as 15mm plaster 1 2297.02 2297.02
12 14.72 Providing and applying Glossy finish Enamel paint mimimum 2 coats in all surface applying @ 0.75 lit/ 10 Sqm up to required finish as per relevent I.S. code 2932: 2013 of (Product such as Asian Apcolite Premium Enamel , Dulux Promise Premium Enamel , Nerolac Synthatic Enamel, Opus Prime enamel ) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackle and labour etc. complete for the work.
Ms Grill Boundary Wall 1 820.01 1.50 1230.02
Deduct Column Area 274 0.30 1.50 123.30
TOTAL 4445434.41
E.E. A.E. Sub E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
Construction of Brick Boundary wall
AS PER BUILDING S.O.R. 10.06.26
S.N. S.O.R. NO. PARTICULAR OF ITEMS NO. L B H/D Qty. Unit Rate Amount
A CONSTRUCTION BRICK BOUNDARY WALL
Left side of main entrance - 224.52 m.
Right side of Main entrance gate - 99.76 m.
Total Length = 224.52 + 99.76 m. 324.28
Column in Every 4.00 m.
Total No. Of Column = 324.58 / 4.00 + 2 = 83 Nos 83
Add Extra Column For Expantion In Every 12.00 m.
No. Of Extra Column = 324.58 / 12 = 27 Nos 27
Total = 56 + 27 = 83 nos
1 1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.
1.1.1 In all types of soils.
C1/F2 ( Footing For Expantion column ) 27 1.80 1.50 1.50 109.35
2 1.17 Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M.
Same as qty of excavation 1 298.35
Qty of pcc BELOW GL 1 19.89
Qty of Rcc up to G.L. 1 46.03
Remaining Earth after foundation filling 65.92
3 3.1 Providing and laying nominal mix cement concrete with crushed stone aggregate using concrete mixer in foundation, plinth and at ground level excluding cost of form work.
3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
4 3.2 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work (Note :Excess/ less cement used as per design mix is payable/ recoverable separately)
3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
Column up to G.L.
Column G.L. To Ground beam Lvl.
Column Above Ground Beam Lvl.
Top Tie Beam In
Total ( A+B ), C 91.06
Column Area in Ground Beam 110 0.30 0.20 0.30 1.98
Column Area In Top Tie Beam 110 0.30 0.20 0.15 0.99
5 3.12 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire all complete :
3.12.2 Thermo-Mechanically treated bars FE 500D
6 2.1 Providing and fixing form work including centering, shuttering, strutting,staging, propping bracing etc. complete and including its removal at all levels, for:
6.1 2.1.1 Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.
Column up to G.L.
Column G.L. To Ground beam Lvl.
Column Above Ground Beam Lvl.
Column Area in Ground Beam, GB1 110 0.30 0.30 9.90
Column Area In Tie Beam, TB1 110 0.30 0.15 4.95
7 7.5 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in:
7.5.4 Cement Mortar 1:6 (1 cement : 6 coarse sand)
Brick work Above Ground Beam 1 324.28 0.20 1.95 126.47
Column In Brick Work 110 0.30 0.20 1.95 12.87
8 11.3 Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix:
11.3.4 In Cement Mortar 1:6 (1 cement : 6 fine sand)
Boundary Wall Both Side 2 324.28 2.10 1361.98
9 14.56 Providing and applying 2mm thick white cement based polymeric Exterior grade Putty with minimum 3 coats applied @ 5.4 kg/ 10Sqm as per relevant IS code 17545:2021 (Product such as Birla wall care, Asian trucare,JK wall putty, Berger Bison wall putty) to make the surface smooth and even with all tools tackles and labour etc. complete for the work.
Qty. same as 15 mm plaster 1361.98
10 14.68 Providing and applying on exterior surface with PREMIUM Exterior emulsion paint of required shade to give protective and water proof finish minimum 3 coats applied @ 1.40 lit / 10Sqm up to final finish as per relevant I.S. Code 15489:2013 Type -2 Class D , C (Glossy /Semi Glossy finish ) (Product such as Asian Apex , Dulux Weather Shield Prima E900 , Berger Weathercoat Antidust , Nerolac Everlas Excel , Nippon Sumo Etra, Opus True flex) inclusive of providing abro tape on edges and articleand cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work.(With 3Year Warranty.)
Qty Same as Putty 1361.98
TOTAL 1517875.68
C.M.O. Sub E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
CONSTRUCTION OF MS GRILL BOUNDARY WALL
AS PER BUILDING S.O.R. 10.06.26
SN REF ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
1 15.5 Boring, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in cement concrete 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size), to carry a safe working load, excluding the cost of steel reinforcement but including the cost of boring with auger by manual means and making one bulb using suitable bulb enlarging tool by MANUAL MEANS with all instruments and arrangements required for boring true to vertical line etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap):
15.5.2 300 mm dia piles.
Pile For Fencing Boundary wall
Pile in Every 3.00 M.
2 1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.
1.1.1 In all types of soils.
3 3.1 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
Pcc Base For Pile Cap 18 0.90 0.90 0.10 1.46
4 3.2 Providing and laying nominal mix reinforcement cement concrete with crushed stone aggregate using concrete mixer in all works upto floor five level excluding cost of reinforcement and form work.
3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
Columm - Pile Cap To 0.90 m. 18 0.20 0.30 0.90 0.97
Pile Cap in Ground Beam 18 0.60 0.20 0.30 0.65
5 3.2.1 +3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 3539.00 + 83.00
Column Above 0.90 m. Lvl. 18 0.20 0.30 1.50 1.62
Deduct Column Area In Tie Beam 18 0.20 0.30 0.15 0.16
5 3.12 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete:
3.12.2 Thermo-Mechanically treated bars FE 500D
Qty beam Rcc 7.93
qty = 90 kg/cum of conc. 954.19 kg 46.00 43892.78
6 2.1 Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for:
6.1 2.1.1 Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.
Ground Beam 1 46.70 0.30 14.01
Pile Cap in Ground Beam 18 0.60 0.30 3.24
6.2 2.1.5 Columns, Pillars, Piers and likes- rectangular or square in shape
6.3 2.1.8 Beams, lintels, cantilevers & walls
Multiplying x2 for sides
Deduct Column Area In Beam 18 0.30 0.15 0.81
7 7.5 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in:
7.5.4 Cement Mortar 1:6 (1 cement : 6 coarse sand)
Brick work Below Ground Beam 1 46.70 0.20 0.10 0.93
Pile Cap in Ground Beam 18 0.60 0.20 0.10 0.22
8 7.5 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in:
7.5.4 Cement Mortar 1:6 (1 cement : 6 coarse sand)
7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 2774.00 + 103.00
Column in Brick Work 18 0.20 0.30 0.75 0.81
8 9.6 Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer.
9.6.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Ms Grill Boundary Wall 1 46.70 1.50 70.05
Deduct Column Area 18 0.30 1.50 8.10
9 11.3 Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix:
11.3.4 In Cement Mortar 1:6 (1 cement : 6 fine sand)
Boundary Wall Outer Side 1 46.70 1.20 56.04
Boundary Wall Inner Side 1 46.70 0.90 42.03
10 14.56 Providing and applying 2mm thick white cement based polymeric Exterior grade Putty with minimum 3 coats applied @ 5.4 kg/ 10Sqm as per relevant IS code 17545 : 2021 (Product such as Birla wall care, Asian trucare,JK wall putty, Berger Bison wall putty) to make the surface smooth and even with all tools tackles and labour etc. complete for the work.
Qty. same as 15 mm plaster 1 134.41 134.41
11 14.68 Providing and applying on exterior surface with PREMIUM Exterior emulsion paint of required shade to give protective and water proof finish minimum 3 coats applied @ 1.40 lit / 10Sqm up to final finish as per relevant I.S. Code 15489 : 2013 Type -2 Class D , C (Glossy /Semi Glossy finish ) (Product such as Asian Apex ,Dulux Weather Shield Prima E900, Berger Weathercoat Antidust, Nerolac Everlas Excel, Nippon Sumo Etra, Opus True flex) inclusive of providing abro tape on edges and articleand cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work.(With 3Year Warranty.
Same as 15mm plaster 1 134.41 134.41
12 14.72 Providing and applying Glossy finish Enamel paint mimimum 2 Coats in al surface applying @ 0.75 lit/ 10 Sqm up to required finish as per relevent I.S. code 2932 : 2013 of (Product such as Asian Apcolite Premium Enamel Dulux Promise Premium Enamel Nerolac Synthatic Enamel, Opus Prime enamel ) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackle and labour etc. complete for the work.
Ms Grill Boundary Wall 1 46.70 1.50 70.05
Deduct Column Area 18 0.30 1.50 8.10
TOTAL 280348.30
E.E. A.E. Sub E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
PAINTING WORK ON EXISTING MS GRILL AROUND ISLAND
AS PER BUILDING S.O.R. 10.06.26
SN REF ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
1 14.93 Providing and applying renewing satin/ matt finish Enamel paint one coats in all surface applying @ 0.75 lit/ 10 Sqm up to required finish as per relevent I.S. code 2932: 2013 of (Product such as Asian satin Enamel, Dulux Promise Premium Enamel , Nerolac Synthatic Enamel, Opus Prime enamel ) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackle and labour etc.complete for the work.
PAINTING WORK ON EXISTING MS GRILL BOUNDARY 1 431.67 1.50 647.51
E.E. A.E. Sub E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
CONSTRUCTION OF R.C.C HUME PIPE FOR INLET
AS PER BUILDING 10.06.26 & ROAD SOR 15.06.26
SN REF ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
CONSTRUCTION OF R.C.C HUME PIPE
1 9.1 Road Sor Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.)
2 9.6 Road Sor Providing 1st class bedding below pipes with graded sand or other granular materials passing through 5.6 mm sieve as per clause 2904.
Qty Same as Excavation 1 60.00 2.25 0.15 20.25
3 9.8 Road Sor Plain cement concrete complete as per drawing and Technical Specifications
(i) PCC Grade M 15
PCC For Pipe Balancing Support
Pcc Area - 0.42 sqm.)
600 mm dia RCC NP3 Pipe Two Row
4 9.4 Road SOR Providing and laying Reinforced Cement Concrete pipe NP 3 / prestressed concrete pipe on first class bedding Laying Reinforced cement concrete pipe NP3 /prestressed concrete pipe complying to IS:458, with ends casted as per the requirements of flush jointing of pipes for culverts on first class bedding of granular material including joints duely filled and finished with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets.
TOTAL 477166.65
E.E. A.E. Sub.E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
CONSTRUCTION OF R.C.C HUME PIPE FOR OUTLET
AS PER BUILDING 10.06.26 & ROAD SOR 15.06.26
SN REF ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
CONSTRUCTION OF R.C.C HUME PIPE
1 9.1 Road Sor Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.)
2 9.6 Road Sor Providing 1st class bedding below pipes with graded sand or other granular materials passing through 5.6 mm sieve as per clause 2904.
Qty Same as Excavation 1 60.00 2.25 0.15 20.25
3 9.8 Road Sor Plain cement concrete complete as per drawing and Technical Specifications
(i) PCC Grade M 15
PCC For Pipe Balancing Support
Pcc Area - 0.42 sqm.)
600 mm dia RCC NP3 Pipe Two Row
4 9.4 Road SOR Providing and laying Reinforced Cement Concrete pipe NP 3 / prestressed concrete pipe on first class bedding Laying Reinforced cement concrete pipe NP3 /prestressed concrete pipe complying to IS:458, with ends casted as per the requirements of flush jointing of pipes for culverts on first class bedding of granular material including joints duely filled and finished with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets.
TOTAL 477166.65
E.E. A.E. Sub.E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
WATER SUPPLY WORK FOR LANDSCAPE
AS PER BUILDING S.O.R. 10.06.26
SN REF ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
1 19.6 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
19.6.1 15 mm nominal outer dia pipes 1 100.00 100.00 Rm 78.00 7800.00
19.6.3 25 mm nominal outer dia pipes 1 500.00 500.00 Rm 140.00 70000.00
19.6.6 50 mm nominal outer dia pipes 1 200.00 200.00 Rm 405.00 81000.00
2 19.17 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
19.17.3 25 mm nominal bore 83 83.00 Each 367.00 30461.00
3 19.16 Providing and fixing brass/ gun metal gate valve with C.I. wheel of approved quality (screwed end):
19.16.4 50 mm nominal bore 5 5.00 Each 648.00 3240.00
TOTAL 192501.00
E.E. A.E. Sub E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
CONSTRUCTION WORK OF RCC DRAIN
ROAD S.O.R. 15.06.26
SN REF ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
RCC DRAIN (0.60 M. X 0.60 M.)
1 3.19 Construction of RCC open drain
(b) Construction of RCC open drain with width 0.60m or 0.45 m (inside dimension) and average depth from inlet to outlet 0.60m or 0.45 m (maintaing slope as per site conditions) with 120 mm thick RCC M-25 walls, 120 mm thick RCC M-25 bottom slab, over 100 mm thick (Av.) levelling course in PCC M-15 including excavation, dressing of sides and bottom, providing HYSD reinforcement consisting of 8 mm dia horizontal bars @ 150 mm c/c and U-shaped 8 mm dia bars @ 150 mm c/c including cutting,bending and binding wires, placing in position, providing shuttering and concreting by using cocrete mixer , compaction by vibration etc complete as per drawings and technical specifications.
(i) 0.60 m width x 0.60 m average depth
Drain Around Pond
2 3.22 Providing and laying Pre cast RCC slab over RCC drain of required size made of grade RCC M-25 with 50mm dia perforation @ 600mm c/c in two rows in zig-zag pattern as per structural drawing including transportation of pre cast segements to work site and placing over drain as instructed by Engineer-in-charge.
(i) Slab with reinforcement 10mm dia at 150mm c/c both ways
B 840mm wide and 150mm thick (for drain 600 x 600 mm)
TOTAL 3855664.30
E.E. A.E. Sub.E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
CONSTRUCTION OF ENTRANCE GATE 01
As Per Building Sor 10.06.26 & Road Sor 15.06.26
S.N. S.O.R. NO. PARTICULAR OF ITEMS NO. L B H/D Qty. Unit Rate Amount
1 1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.
1.1.1 In all types of soils.
2 1.6 Extra for every additional lift of 1.5 m or part thereof.
1.6.1 In all types of soils.
3 1.17 Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M.
Same as qty of excavation 1 x 18.52 18.52
Qty of pcc BELOW GL 1 x 1.32 1.32
Qty of Rcc up to G.L. 1 x 3.52 3.52
Remaining Earth after foundation filling 4.85
4 3.1 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
5 3.2 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. (Note :Excess/ less cement used as per design mix is payable/ recoverable separately)
3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
Column up to G.L.
6 3.2.1 + 3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 3539.00 + 83.00
7 3.12 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire all complete:
3.12.2 Thermo-Mechanically treated bars FE 500D
8 2.1 Providing and fixing form work including centering, shuttering, strutting,staging, propping bracing etc. complete and including its removal at all levels, for:
8.1 2.1.1 Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.
Column up to G.L.
Beams Sides multiplied X2
8.2 2.1.5 Columns, Pillars, Piers and likes- rectangular or square in shape
8.3 2.1.7 Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)
8.4 2.1.8 Beams, lintels, cantilevers & walls
Multiplying x2 for sides
9 7.5 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: 2774.00 + 103.00
7.5.4 Cement Mortar 1:6 (1 cement : 6 coarse sand)
7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
In Super Structure(G.F)
10 9.3 Steel work in tubular (round, square or rectangular hollow tubes etc.) structure in built-up sections, trusses and frame work including cutting, hoisting, fixing in position upto a height of 5m above plinth level, consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer.
9.3.1 Electric resistance or induction butt welded tubes Grade-250
Entrance Gate assuming 45kg/sqm) 1 6.00 2.10 12.60
Temple Side small Gate 1 3.00 2.10 6.30
11 11.1 Providing and making 6mm thick cement plaster of mix:
11.1.2 In Cement mortar 1:4 (1 cement : 4 fine sand)
Ceiling Plaster
12 11.3 Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix:
11.3.4 In Cement Mortar 1:6 (1 cement : 6 fine sand)
Back & Front 2 7.60 0.60 9.12
13 14.56 Providing and applying 2mm thick white cement based polymeric Exterior grade Putty with minimum 3 coats applied @ 5.4 kg/ 10Sqm as per relevant IS code 17545 :2021 (Product such as Birla wall care, Asian trucare, JK wall putty, Berger Bison wall putty) to make the surface smooth and even with all tools tackles and labour etc. complete for the work.
Qty. same as 6 mm plaster 4.94
Qty. same as 15 mm plaster 28.48
14 14.68 Providing and applying on exterior surface with PREMIUM Exterior emulsion paint of required shade to give protective and water proof finish minimum 3 coats applied @ 1.40 lit / 10Sqm up to final finish as per relevant I.S. Code 15489 :2013 Type -2 Class D , C (Glossy /Semi Glossy finish ) (Product such as Asian Apex , Dulux Weather Shield Prima E900 , Berger Weathercoat Antidust , Nerolac Everlas Excel , Nippon Sumo Etra, Opus True flex) inclusive of providing abro tape on edges and articleand cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work.(With 3Year Warranty.)
Same as Plaster 33.42
15 14.72 Providing and applying Glossy finish Enamel paint mimimum 2 coats in all surface applying @ 0.75 lit/ 10 Sqm up to required finish as per relevent I.S. code 2932: 2013 of (Product such as Asian Apcolite Premium Enamel , Dulux Promise Premium Enamel , Nerolac Synthatic Enamel, Opus Prime enamel ) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackle and labour etc. complete for the work.
Temple Side small Gate 1 3.00 2.10 6.30
16 RS 12.14 Cement art Mural work
Around Column 2 1.80 4.40 15.84
Top Wall Both Side 2 6.90 1.20 16.56
Total (A) 260153.71
B LED GLOW SIGN BOARD FOR GATE - 1
17 ELE . SOR 6.58 Supplying, installation, testing and commissioning of Acrylic LED light (a) Specification of Acrylic 3 mm thick x 3 " width x 4 " depth * (imbose) (b) Specification of LED modules :- Each Moduel should have 6 Nos LED of 1 watt
18 ELE . SOR 6.61 Fabrication and installation of angle iron including angle size 50 mm x 5 mm thick with labour charges including materials as per specification
Assuming 2.50 kg / sqft
19 ELE . SOR 6.62 Providing and fixing aluminium composite panels in approved panel sizes, thickness and shape on aluminium frame work
6.62.1 4 mm thick
Total (B) 50814.80
Cost of One unit TOTAL (A+B) 310968.51
E.E. A.E. SUB E ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
CONSTRUCTION OF SIDE ENTRANCE GATE
As Per Building Sor 10.06.26 & Road Sor 15.06.26
S.N. S.O.R. NO. PARTICULAR OF ITEMS NO. L B H/D Qty. Unit Rate Amount
A CONSTRUCTION OF SIDE ENTRANCE GATE (GATE 02 & 03)
1 1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.
1.1.1 In all types of soils.
2 1.6 Extra for every additional lift of 1.5 m or part thereof.
1.6.1 All types of soils
3 1.17 Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M.
Same as qty of excavation 1 18.52
Qty of pcc BELOW GL 1 1.32
Qty of Rcc up to G.L. 1 3.52
Remaining Earth after foundation filling 4.85
4 3.1 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
5 3.2 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. (Note :Excess/ less cement used as per design mix is payable/ recoverable separately)
3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
Column up to G.L.
6 3.2.1 + 3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 3539+83
7 3.12 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire all complete:
3.12.2 Thermo-Mechanically treated bars FE 500D
8 2.1 Providing and fixing form work including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for:
8.1 2.1.1 Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.
Column up to G.L.
Beams Sides multiplied X2
8.2 2.1.5 Columns, Pillars, Piers and likes- rectangular or square in shape
8.3 2.1.8 Beams, lintels, cantilevers & walls
Multiplying x2 for sides
9 9.3 Steel work in tubular (round, square or rectangular hollow tubes etc.) structure in built-up sections, trusses and frame work including cutting, hoisting, fixing in position upto a height of 5m above plinth level, consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer.
9.3.1 Electric resistance or induction butt welded tubes Grade-250
Entrance Gate assuming 45kg/sqm) 1 4.00 2.10 8.40
9 11.1 Providing and making 6mm thick cement plaster of mix:
11.1.2 In Cement mortar 1:4 (1 cement : 4 fine sand)
Ceiling Plaster
Top Beam - Bottom & Top 2 4.25 0.20 1.70
10 11.3 Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix:
11.3.4 In Cement Mortar 1:6 (1 cement : 6 fine sand)
Top Beam Back & Front 2 4.25 0.45 3.83
11 14.56 Providing and applying 2mm thick white cement based polymeric Exterior grade Putty with minimum 3 coats applied @ 5.4 kg/ 10Sqm as per relevant IS code 17545 :2021 (Product such as Birla wall care, Asian trucare, JK wall putty, Berger Bison wall putty) to make the surface smooth and even with all tools tackles and labour etc. complete for the work.
Qty. same as 6 mm plaster 1.70
Qty. same as 15 mm plaster 15.89
12 14.68 Providing and applying on exterior surface with PREMIUM Exterior emulsion paint of required shade to give protective and water proof finish minimum 3 coats applied @ 1.40 lit / 10Sqm up to final finish as per relevant I.S. Code 15489 :2013 Type -2 Class D , C (Glossy /Semi Glossy finish ) (Product such as Asian Apex , Dulux Weather Shield Prima E900 , Berger Weathercoat Antidust , Nerolac Everlas Excel , Nippon Sumo Etra, Opus True flex) inclusive of providing abro tape on edges and articleand cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work.(With 3Year Warranty.)
Qty. same as putty work 1 17.59
Qty. same as inside 15mm plaster 1 15.89
13 14.72 Providing and applying Glossy finish Enamel paint mimimum 2 coats in all surface applying @ 0.75 lit/ 10 Sqm up to required finish as per relevent I.S. code 2932: 2013 of (Product such as Asian Apcolite Premium Enamel , Dulux Promise Premium Enamel , Nerolac Synthatic Enamel, Opus Prime enamel ) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackle and labour etc. complete for the work.
Total (A) 95093.53
B LED GLOW SIGN BOARD FOR GATE
14 ELE . SOR 6.58 Supplying, installation, testing and commissioning of Acrylic LED light (a) Specification of Acrylic 3 mm thick x 3" width x 4" depth *(imbose) (b) Specification of LED modules:- Each Moduel should have 6 Nos LED of 1 watt
15 ELE . SOR 6.61 Fabrication and installation of angle iron including angle size 50 mm x 5 mm thick with labour charges including materials as per specification
Assuming 3.50 kg / sqft
16 ELE . SOR 6.62 Providing and fixing aluminium composite panels in approved panel sizes, thickness and shape on aluminium frame work
6.62.1 4 mm thick
Total (B) 40883.81
Cost of One Unit 135977.33 271954.6634
Cost of Two Units 271954.66
E.E. A.E. SUB E ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
[ As per P.H.E.D -U.S.O.R 2020, AMENDMENT NO-09/2023-24 ]
SN REF NO. ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
1 28.1 Carrying out the resistivity survey by VES method using Schlumberger configuration for locating the proper spot with three soundings for drilling of tube well with in the selected Habitation, including photography, interpretation of resistivity data and submission of report in the desired format along with resistivity readings, necessary graph and photographs. 1 1.00 Per successful point 2058.00 2058.00
2 29.3 Drilling of perfectly vertical bore hole of a diameter suitable to receive 150 mm nominal diameter casing pipe upto desired depth below ground level inclusive of the labour charges for transporting, lowering and fixing of 150 mm nominal diameter and fixing of 150 mm nominal diameter M.S./ G.I. / U.P.V.C. casing pipe inside the bore hole including all works pertaining to drilling such as transportation, installation and removal of drilling machine etc.complete.
2.1 a) In all type of collapsible strata consisting of soils, clays, sand , moorum, gravel, boulders etc. 1 45.00 45.00 Mtr 664.00 29880.00
2.2 b) In all types of rocks. 1 115.00 115.00 Mtr 805.00 92575.00
3 29.9 Providing and fixing of well cap on top of the tube well for protection
4 29.10 Construction of concrete block over dry tube wells for protection of size 0.45m x 0.45m x 0.45m in M-15 cement concrete mix complete work. 1 1.00 each 793.00 793.00
5 3 (page -356) ISI Mark 32 mm dia. G.I. riser pipe in 3 meter length socketed on one end as per I.S. 1239 (Part I) 1990 up-to- date amendments and socket as per I.S. 2062/ 1990 up-to-date amendment, Part-C, General Note: 27.28.10
6 6 (page -356) ISI marked G.I. casing pipe (Plain) medium class in 4 to 7 meters length one end fitted with socket as per I.S.: 1239 (Part-2) 1992 with IV th revision ( Up-to date amendments), Part-C, General Note: 27.28.10
CM casing pipes, 150 mm dia
7 34.20.105 Supplying & Installation of Energy efficiant five star BEE rating ISI Marked required capacity single phase, 50 Hz, 220V, deep well submersible pump Stainless Steel body, suitable for 4"/6" tube well with Contral Panel Starter suitable for Submersible pump with dry run protection, connections, including clamps, bore cap etc. as required as per specifications but excluding pipe,SS/ Nylon wire rope and connection cable.
(xv) 2 H.P. with 25 stages, Head Mt. 163-58 Discharge LPM 10-45 1 1.00 each 33288.00 33288.00
8 34.20.107 (354) Supplying and laying of submersible flat cable ISImarked 3 core copper wire of suitable size with proper clamping of approved make.
2.5 Sq.mm.multi strand 1 145.00 145.00 Mtr. 121.00 17545.00
9 6.1 Providing laying and jointing of following galvanized Iron (MS) Pipes with specials (such as bends, elbows, tees etc) class light, medium & heavy including testing of joints, cost of pipes, specials and jointing materials all complete. Pipes and sockets conforming to IS:1239/ 2011 Part- II.
50mm dia (Medium)
Bore To Water Tank 1 15.00 15.00 R Mtr. 409.00 6135.00
10 6.3 Providing and fixing following gate (full way) valves tested to 300lbs/ Sq inch or 21.00 kg/sq.cm. confirming to IS 778/ 1984 (Reaffirmed 2005) Class-I
50mm dia (Medium) 1 1.00 1.00 Each 2525.00 2525.00
TOTAL 264568.00
E.E. A.E. Sub.E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
CONSTRUCTION WORK OF TOILET BLOCK
AS PER BUILDING SOR 10.06.26
SN REF ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
1 1.2 Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish upto 1.5 m lift and lead upto 50m (at least 5m away from the dressed area).
Cleaning area 1 8.20 4.80 39.36
2 1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.
1.1.1 In all types of soils.
3 1.17 Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M.
Same as qty of excavation 1 13.50
Qty of pcc BELOW GL 1 1.63
Qty of Rcc up to G.L. 1 3.98
Remaining Earth after foundation filling 5.61
4 1.18 Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete.
Plinth Fillling
Disable Toilet 1 1.40 2.10 0.45 1.32
Qty. of pcc base on floor 1 2.79
Remaining Earth after foundation filling 5.61
G.Total(A-B) 1.88 cum 315.00 590.78
5 3.1 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
FLOOR BASE INCLUDING STAGE
Disable Toilet 1 1.40 2.10 0.10 0.29
6 3.2 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. (Note :Excess/ less cement used as per design mix is payable/ recoverable separately)
3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
Column up to G.L.
Column Site Filling Lvl. To P.L.
7 3.2.1 + 3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 3539.00 + 83.00
Toilet Partition Wall
Projection 1 6.90 1.00 0.125 0.86
Basin Counter Slab
Female Toilet 1 1.30 0.45 0.100 0.06
8 3.12 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire all complete:
3.12.2 Thermo-Mechanically treated bars FE 500D
9 3.13 Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including form work.
10 2.1 Providing and fixing form work including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for:
10.1 2.1.1 Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.
Column up to G.L.
Column upto P.L.
Beams Sides multiplied X2
10.2 2.1.5 Columns, Pillars, Piers and likes- rectangular or square in shape
10.3 2.1.7 Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)
Basin Counter Slab
Female Toilet 1 1.00 0.45 0.45
Male Toilet 1 1.50 0.45 0.68
10.4 2.1.8 Beams, lintels, cantilevers & walls
Multiplying x2 for sides
Toilet Partition Wall
11 7.5 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in:
7.5.4 Cement Mortar 1:6 (1 cement : 6 coarse sand)
Brick work between G. L. To P.L.
Threshold steps
Verandah side Wall 1 3.60 0.20 0.45 0.32
Ramp Side Wall 1 4.50 0.20 2.25 2.03
12 7.5.4 + 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 2774.00 + 103.00
In Super Structure(G.F)
13 7.11 Half brick thick brick masonry with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in superstructure above plinth level upto plinth level:
7.11.2 Cement Mortar 1:4 (1 cement : 4 coarse sand)
7.12 Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for upto plinth level:
7.20 Extra for providing and placing in position hopping 25x1.60 mm or 2 Nos 6mm dia MS bars reinforcement at every third course of half brick masonry.
Toilet Partition Wall
Male toilet 1 1.30 2.10 2.73
Female toilet 1 2.10 2.10 4.41
Deduction Rate 325 + 9 + 53
14 8.1 Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position.
14.1 8.1.2 Sal, bijasal, benteak, khair, haldu
15 8.3 Providing 40x5mm iron hold fast 40cm long including fixing to frame with 10mm bolts nuts and wooden plug and embedding in Cement Concrete 1:2:4 in blocks of size 30x10x15cm.
Total 36.00 each 62.00 2232.00
16 8.16 Providing and fixing PVC membrane foil coated (laminated) flush door shutters, made with core of block board with frame of first class hard wood, coated with 0.30mm membrane pasted with resin using vacuam treatment process complete all but excluding hinges.
8.16.1 35 mm thick (single leaf)
17 8.154 Providing and fixing 30mm thick fibreglass reinforced plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856 : 2000, complete.
18 8.58 Providing and fixing bright finished brass butt hinges with brass polished MS screws complete:
8.58.1 125x85x5.50 mm (Heavy Type)
19 8.60 Providing and fixing bright finished brass sliding door bolt with nuts and brass polished MS screws complete:
20 8.61 Providing and fixing brass door latch with brass polished MS screws complete:
21 8.62 Providing and fixing bright finished brass tower bolts (barrel type) with brass polished MS screws complete:
Total 6.00 each 196.00 1176.00
22 8.65 Providing and fixing bright finished brass door handles with brass polished MS screws complete:
Total 12.00 each 47.00 564.00
23 8.158 Providing and fixing IS: 3564 marked aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc complete.
24 9.15 Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.
25 9.57 Providing stainless steel railing/ grill made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design fixing in stair case, balcony or other places with metal fasteners and stainless steel bolts etc complete.
9.57.2 SS Grade 304
railing for ramp 1 4.50 0.90 4.05
Verandah + Steps 1 2.00 0.90 1.80
asuming 10.00 kg per sqm. 10 x 5.85 58.50 kg 446.00 26091.00
26 9.47 Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately:
26.1 9.47.1 For fixed portion
For Wt. @ 5kg/Sqm 12.60
26.2 9.47.2 For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately).
For Wt. @ 5kg/Sqm G. Total 12.60 kg 287.00 3616.20
27 9.51 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading shall be paid in basic item):
9.51.2 With float glass panes of 5 mm thickness
28 11.1 Providing and making 6mm thick cement plaster of mix:
11.1.2 In Cement mortar 1:4 (1 cement : 4 fine sand)
Ceiling Plaster
Slab Projection 1 6.90 1.00 6.90
Disable Toilet 1 1.40 2.10 2.94
Female Toilet 1 2.10 3.20 6.72
Male Toilet 1 2.60 3.20 8.32
Basin Counter Slab
Female Toilet 1 1.00 0.60 0.60
Male Toilet 1 1.50 0.60 0.90
29 11.2 Providing and making 12mm thick cement plaster of mix:
11.2.4 In Cement Mortar 1:6 (1 cement : 6 fine sand)
Deduction x 0.50
30 11.3 Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix:
11.3.4 In Cement Mortar 1:6 (1 cement : 6 fine sand)
Front & Back 2 6.90 3.35 46.23
Left & right side 2 3.60 3.35 24.12
Total Outer Plaster 15mm 70.35
Total outside plaster 70.35
Deduction : x 0.50
Total Deductions 1.26
G.Total(A-B) 69.09 sqm 91.00 6287.19
31 12.7 Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete.
12.7.1 Size 200x300mm
Female Toilet 4 1.00 2.10 8.40
Male Toilet 2 1.00 2.10 4.20
Disable Toilet Wall 2.10
Total Deductions B 16.70
32 12.9 Providing and laying ceramic glazed floor tiles conforming to IS : 15622 of approved size, make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete.
12.9.1 Size 300x300mm
Disable Toilet 1 1.40 2.10 2.94
Male Toilet 1 2.60 3.20 8.32
Female Toilet 1 2.10 3.20 6.72
33 12.45 15 mm thick Table rubbed polished Granite stone slab flooring laid over 20mm (Average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing etc. complete. (Area of slab should be 0.50 sqm and above)
12.45.2 Granite stone black
Basin Counter Slab
Female Toilet 1 1.00 0.60 0.60
Male Toilet 1 1.50 0.60 0.90
34 12.46 15 mm thick Table rubbed polished Granite stone slab in risers and treads of steps skirting dado and pillars laid on 12mm (Average) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry including rubbing and polishing etc. complete (single stone is to be used for risers and treads of steps and width of stone for skirting and dado shall be equal to the height of skirting & dado and length of 1.0 m).
12.46.2 Granite stone black
Verandah 1 3.60 1.00 3.60
Threshold steps
Urinal Partition
35 12.44 Extra for nosing in Granite stone for treads. 1 8.30 8.30 M 107.00 888.10
36 14.56 Providing and applying 2mm thick white cement based polymeric Exterior grade Putty with minimum 3 coats applied @ 5.4 kg/ 10Sqm as per relevant IS code 17545:2021 (Product such as Birla wall care, Asian trucare, JK wall putty, Berger Bison wall putty) to make the surface smooth and even with all tools tackles and labour etc. complete for the work.
Qty. same as 6 mm plaster 31.42
Qty. same as 12 mm plaster 101.69
Qty. same as 15 mm plaster 69.09
37 14.64 Providing and applying Premium plastic emulsion paint with roller application minimum three coats applied @ 0.75 lit / 10Sqm up to final finish as per relevant I.S. Code 15489:2013 Type -1 Class D & C ( Glossy and Semi Glossy Finish) of required shade (Product such as Asian Apcolite Premium , Dulux Super Cover, Berger Easy Clean , Nippon Breezee Metex Gold, Opus I-50 / Calista) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work.(with 3 year Warranty)
Qty. same as putty work 1 202.20
Qty. same as inside 15mm plaster 1 69.09
38 14.68 Providing and applying on exterior surface with PREMIUM Exterior emulsion paint of required shade to give protective and water proof finish minimum 3 coats applied @ 1.40 lit / 10Sqm up to final finish as per relevant I.S. Code 15489:2013 Type -2 Class D , C (Glossy /Semi Glossy finish ) (Product such as Asian Apex , Dulux Weather Shield Prima E900 , Berger Weathercoat Antidust , Nerolac Everlas Excel , Nippon Sumo Etra, Opus True flex) inclusive of providing abro tape on edges and articleand cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work.(With 3Year Warranty.)
Same as 15mm plaster 69.09
39 14.72 Providing and applying Glossy finish Enamel paint mimimum 2 coats in all surface applying @ 0.75 lit/ 10 Sqm up to required finish as per relevent I.S. code 2932: 2013 of (Product such as Asian Apcolite Premium Enamel , Dulux Promise Premium Enamel , Nerolac Synthatic Enamel, Opus Prime enamel ) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackle and labour etc. complete for the work.
TOTAL 428151.05
ADD 15 % FOR ELECTRIFICATION & PLUMBING 64222.66
G. Total 492373.71
E.E. A.E. SUB E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
CONSTRUCTION WORK OF SEPTIC TANK
AS PER BUILDING SOR 10.06.26
SN REF ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
1 1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.
1.1.1 In all types of soils.
2 1.6.1 All types of soils
Septic tank 1 3.00 4.00 0.60 7.20
3 1.17 Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M.
Same as qty of excavation 1 25.20
Qty of pcc BELOW GL 1 3.00 4.00 0.10 1.20
Qty of Rcc raft 1 2.80 3.80 0.20 2.13
Remaining Earth after foundation filling (B) 22.48
Remaining Earth after foundation filling 22.48
4 1.26 Carriage by mechanical transport upto 5 km lead:
Remaining Earth after back filling 1 x 22.48 22.48
5 3.1 Providing and laying nominal mix cement concrete with crushed stone aggregate using concrete mixer in foundation, plinth and at ground level excluding cost of form work.
5.1 3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
Septic tank 1 3.00 4.00 0.10 1.20
6 3.2 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. (Note :Excess/ less cement used as per design mix is payable/ recoverable separately)
3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
Baffle Wall 1 2.50 0.15 1.50 0.56
man hole cover 1 0.60 0.60 0.15 0.054
7 3.12 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire all complete:
3.12.1 Thermo-Mechanically treated bars FE 415
8 2.1 Providing and fixing form work including centering, shuttering, strutting,staging, propping bracing etc. complete and including its removal at all levels, for:
8.1 2.1.1 Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.
Baffle Wall 1 X 2 2 2.50 1.50 7.50
9 11.1 Providing and making 6mm thick cement plaster of mix:
11.1.2 In Cement mortar 1:4 (1 cement : 4 fine sand)
Wall Inner side 2 2.50 2.10 10.50
10 11.5 Neat Cement punning.
Wall Inner side 2 2.50 2.10 10.50
E.E. A.E. SUB E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
EXTERNAL ELECTRICAL WORK
AS PER ELECTRICALE S.O.R. 10.06.26
SN Sor No. Description of Item Qty. Unit Rate Amount
(A) SOLAR STREET LIGHT
1 6.81 Supplying, Installation, testing and commissioning of hybrid solar street luminaire of housing made of extruded Aluminium and IP65 ingress protection. The all in one solar street lighting system having system lumen output up to 120 LPW (as per LM79 report of NABL accredited lab only), CCT of 6500k (+/- 500k) and CRI > 70, L70 should be of 50000 hours or more. The luminaire should be having SMD type LEDs with secondary lens / optics suitable for street lighting application, MPPT charge Controller and DC driver and automatic dusk to dawn operation feature. The All in one Solar Street light must have hybrid feature under which LED light can be operate by both AC mains & DC supply. The integrated luminaire should have monocrystalline PV module, Lithium battery pack having upto 10Hrs. of autonomy with full power mode and upto 36Hrs. of autonomy with saving mode. Specially designed in built PIR sensor allows to sense motion i.e. if a human is within sensor range then streetlight is at 100% full power lighting mode otherwise if no movement is detected to save energy it dims down to 30% of power.
6.81.3 60w ,90Wp Monocrystalline Panel - 12.8V 52Ah Lithium Ferro Phsophate (LifePo4) battery 46 Each 58982.00 2713172.00
2 19.7 Supply of hot dipped galvanized (in single dip to minimum 75 micron) octogonal pole made of 3mm thick steel grade E-350 sheet having window and flush cover with locking arrangement at suitable height from base for cable termination block, pole suitably reinforced with welded steel section at window cut section to make the strength of pole unaffected, with following minimum specifications with 4 way terminal connector including 3mm thick anchor plate, 4 nos 20mm dia foundation bolts of EN8 grade, and as per IS 2062 & BS EN: 10025. (designed for wind speed upto 180km/hr, IS: 875 Part 3)
19.7.2 7 metre high, dia 130mm at bottom and 90mm at top, base plate size 220x220x12mm, foundation bolts 700mm long 46 Each 9297.00 427662.00
3 19.11 Erection of GI octagonal/ tubular/ conical pole on existing cement concrete foundation having grouted bolts and nuts, aligning in true vertical position as per specification.
4 19.12 Designing and providing suitable RCC foundation in Cement Concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) for 3 mere to 12 metre high GI octagonal pole including steel reinforcement form work, embeding 2 nos 50mm dia PVC pipe for cable entry in each foundation, excavation disposal of surplus soil and curing etc. as per specification.
Qty. of Concrete , 0.60 x 0.60 x 1.50 m. = 0.54 cum for Each pole 25 cum 4436.00 110190.24
3 19.25 Supplying and fixing of single over hang (Arm) 1000 MM (long)x50 mm dia decorative GI street light pole bracket made out of GI "A" Class pipe welded to 300 MM Long GI Pole canopy of suitable dia at angle of 102.50 Degree including having GI triangular stiffner and making arrangement for tightening the bracket with pole by providing suitable size heavy duty nuts and bolts in canopy including FRP Dome on existing pole etc. as per enclosed drawing and as per direction of engineer-in-charge. 46 Each 1685.00 77510.00
TOTAL 3361792.24
E.E. A.E. Sub. E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
AS PER BUILDING SOR 10.06.26
S.N. S.O.R. NO. PARTICULAR OF ITEMS NO. L B H/D Qty. Unit Rate Amount
A CONSTRUCTION OF YOGA CHABUTARA
1 1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.
1.1.1 In all types of soils.
2 1.17 Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M.
Same as qty of excavation 1 6.34
Qty of pcc BELOW GL 1 0.53
Qty of Rcc up to G.L. 1 1.16
Remaining Earth after foundation filling 1.69
3 1.18 Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete.
Qty. of pcc base on floor 1 0.27
4 3.1 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
PCC BASE FOR FOOTING
Front Steps 1 1.20 0.90 0.10 0.11
5 3.2 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. (Note :Excess/ less cement used as per design mix is payable/ recoverable separately)
3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
COLUMN UP TO G.L.
COLUMN G.L. TO P.L.
Chabutara Top Slab 1 1.20 2.40 0.10 0.29
6 3.12 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire all complete:
3.12.2 Thermo-Mechanically treated bars FE 500D
7 3.13 Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including form work.
8 2.1 Providing and fixing form work including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for:
8.1 2.1.1 Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.
COLUMN UP TO G.L.
COLUMN G.L. TO P.L.
Beams Sides multiplied X2
9 7.5 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in:
7.5.4 Cement Mortar 1:6 (1 cement : 6 coarse sand)
BRICK WORK G.L. To P.L.
Threshold Steps 1 1.20 0.90 0.150 0.16
10 11.3 Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix:
11.3.4 In Cement Mortar 1:6 (1 cement : 6 fine sand)
Chabutara 2 2.40 0.60 2.88
Total Outer Plaster 15mm 4.32
Total outside plaster 4.32
Total Deductions 0.72
11 12.45 15 mm thick Table rubbed polished Granite stone slab flooring laid over 20mm (Average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing etc. complete. (Area of slab should be 0.50 sqm and above)
12.45.2 Granite stone black
12 12.46 15 mm thick Table rubbed polished Granite stone slab in risers and treads of steps skirting dado and pillars laid on 12mm (Average) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry including rubbing and polishing etc. complete (single stone is to be used for risers and treads of steps and width of stone for skirting and dado shall be equal to the height of skirting & dado and length of 1.0 m).
12.46.2 Granite stone black
Threshold steps
13 12.44 Extra for nosing in Granite stone for treads. 1 3.60 3.60 M 107.00 385.20 54 5778
14 14.56 Providing and applying 2mm thick white cement based polymeric Exterior grade Putty with minimum 3 coats applied @ 5.4 kg/ 10Sqm as per relevant IS code 17545:2021 (Product such as Birla wall care, Asian trucare, JK wall putty, Berger Bison wall putty) to make the surface smooth and even with all tools tackles and labour etc. complete for the work.
Qty. same as 15 mm plaster 3.60
15 14.64 Providing and applying Premium plastic emulsion paint with roller application minimum three coats applied @ 0.75 lit / 10Sqm up to final finish as per relevant I.S. Code 15489:2013 Type -1 Class D & C ( Glossy and Semi Glossy Finish) of required shade (Product such as Asian Apcolite Premium , Dulux Super Cover, Berger Easy Clean , Nippon Breezee Metex Gold, Opus I-50 / Calista) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work.(with 3 year Warranty)
Qty. Same As Item No. 14.53 1 3.60
Cost For 1 Chabutara TOTAL 34473.12
Cost For 15 Chabutara 15 34473.12 517096.86 517096.86
E.E. A.E. SUB.E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
ELECTRICAL SOR 10.06.26
SN REF ITEM DESCRIPTION QTY UNIT RATE AMOUNT
1 6.55 Supplying , installation , testing and commissioning of photovoltic solar panels of 12 Volt 40 Watt as per the specifications 75.00 Each 2321.00 174075.00
2 6.56 Supplying , installation , testing and commissioning of solar frame for panel with suitable angle iron required 75.00 Each 1518.00 113850.00
Total 287925.00
E.E. A.E. SUB E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
AS PER ELECTRICALE S.O.R. 10.04.26
SN REF ITEM DESCRIPTION QTY UNIT RATE AMOUNT
1 27.23 Supplying , installation , testing and commissioning of 64 Channel NVR 8 Sata port Up to 64 channel IP camera input , Max 320Mbps incoming bandwidth , Smart H.265+/H.265/Smart H.264+/H.264/MJPEG , Up to 12MP resolution preview and playback , Support 8 SATA HDDs up to 10TB each,1 eSata , 4 USB(2 USB3.0, 2USB2.0) , 2 HDMI / 2 VGA simultaneous video output ,ONVIF Version 2.4 conformance , Alarm In / out 16/6 , Two way talk 1 Channel Input, 2 Channel Output RCA , 1 RS485, 1 RS232 , 2 RJ-45 port (10/100/1000Mbps), Support ANPR Camera as per the specifications. 1 Each 54216.00 54216.00
2 27.13 Supplying , installation , testing and commissioning of 2 MP ANPR Camera Image sensor 1/1.9 CMOS , 2 MP 1920x1080 Lens 10.5~42mm , H.264/H.265/MJPEG , Frame Rate 50/60 FPS, WDR100dB, ANR,AWB, AE, Auto IRIS, Alarm in/ out , Traffic Counting Range 15~80 Mtr , 1RS232 serial Port , 2 RS485 port, , 1 GPS, IR Range of 100 MTR , SD Card 128GB ,,Number Plate snap, Support Traffic Flow , occupancy , heady , average speed , queue, length atatic embedded Integration component design , built in variety algorithm such as ANPR , traffic Data collection and analysis, vehicle type Classification , Traffic incidents detection , vehicle brand . 1 Ethernet Port (100/1000m) , Built in sunshade unit , IP66, AC220V , Mounting accessories as per the specifications. 1 Each 64814.00 64814.00
3 27.11 Supplying , installation , testing and commissioning of 4 MP Bullet Camera weather & dust proof IP based Fixed Lens day/night Camera (IP67 , IK 10) , 1/3” 4MP PS CMOS Image Sensor, H.265 and H.264 triple-stream encoding, WDR(120dB), Day/Night Support, UL ,CE FCC Certified as per the specifications. 10 Each 5400.00 54000.00
4 27.39 Supplying , installation , testing and commissioning of 8 TB Surveillance Hard disk drive Complete as required 2 Each 18407.00 36814.00
5 27.27 Supplying , installation , testing and commissioning of 8 Port Giga PoE Switch 10/100/1000 8 Port with 2 GigaJ 45 uplink, PoE switch ,Al Extend , Al Vian as per the specifications. 2 Each 5704.00 11408.00
6 27.45 Supplying, installation , testing and commissioning of 6U Indoor Rack Wallmount 6U 4500 With Front Glass Door Lock & Key 550 6U- loaded with cable manager+ POU + Fan complete as required. 1 Each 2981.00 2981.00
7 27.48 Providing installation testing and commissioning of 15U Indoor Rack Wallmount 15U 630D With Front Glass Door Lock & Key 550 15U - (Fan, cable manager, PDU included) complete as required 1 Each 7728.00 7728.00
8 9.27 Supplying and fixing Low voltage (class -II) surge protection device (SPD) TP&N 440 volts, in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 2 Each 7013.00 14026.00
9 27.70.1 Supply, installation , testing and commissioning of add on item junction box installed with Mount frame inside for Krone 10 pair disconnection/ disconnections module, Corrosion free impact resistant, water proof, mild steel stable and maintenance free with same size crone module as junction box. 20 Pair Juction box
27.70.1 20 Pair Juction box 1 Each 2499.00 2499.00
10 27.34 Supplying , installation , testing and commissioning of 24 Port Managable POE Switch 10/100/1000 24 Port Managed PoE Switch with 2 Giga RJ45 & 2 Giga SFP combo uplink, Power Budget250W as per the specificatons. 1 Each 20546.00 20546.00
11 27.49 Supplying, installation, testing and commissioing of following size LED Monitor, table/wall mount with inbuild speaker minimum 5Wx2,with minimum 1 No of HDMI and USB port including remote control, connecting cable, batteries, and all accessories, connection etc complete as per specification.
12 11.2 Supplying, installation, testing and commissioning following rating single phase in single phase out ON-LINE UPS including connection etc but without batteries as per specification.
11.2.1 2 KVA with DC bus voltage 72 V 2 Each 23260.00 46520.00
G.Total 363172.00
E.E. A.E. SUB E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
AS PER ELECTRICAL SOR 10.06.26
SN REF ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
1 Ele 24.23 Supplying, installation, testing and commissiong of following size drinking water cooler storage type ISi marked, eco friendly non CFC refrigarant, water tank and cooler cabinet sheet material- stainless steel {grade AISI 304} with thickness>= 0.8 mm, with PUF insulation including all accessories connection etc complete as per specification.
TOTAL 121299.00
E.E. A.E. SUB E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
REHABILITATION OF COMMERCIAL SPACE FOR SHOP
AS PER BUILDING SOR 10.06.2026
SN REF ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
A CONSTRUCTION OF SHOPS
1 1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.
1.1.1 In all types of soils.
2 1.17 Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M.
Same as qty of excavation 1 x 21.87 21.87
Qty of pcc BELOW GL 1 x 1.46 1.46
Qty of Rcc up to G.L. 1 x 3.26 3.26
Remaining Earth after foundation filling 4.72
3 1.18 Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete.
Plinth Fillling
Qty. of pcc base on floor 1 x 4.38 4.38
Remaining Earth after foundation filling 1 x 4.72 4.72
4 3.1 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
Below Threshold Steps
5 3.1.5 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 40mm nominal size).
6 3.2 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. (Note :Excess/ less cement used as per design mix is payable/ recoverable separately)
3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
Footing Trapezoidal
Trapezoidal Area { h/3 x [ A1 + A2 + SQRT (A1 x A2)]}
Column up to G.L.
Column F.L. To P.L.
7 3.2.1 + 3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 3539.00 + 83.00
Column Above Site Filling Lvl.
8 3.12 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire all complete:
3.12.2 Thermo-Mechanically treated bars FE 500D
9 3.13 Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including form work.
10 2.1 Providing and fixing form work including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for:
10.1 2.1.1 Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.
Column up to G.L.
Column G.L. To P.L
Beams Sides multiplied X2
10.2 2.1.5 Columns, Pillars, Piers and likes- rectangular or square in shape
Column Above P.L.
10.3 2.1.7 Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)
10.4 2.1.8 Beams, lintels, cantilevers & walls
Multiplying x2 for sides
11 7.5.4 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: Cement Mortar 1:6 (1 cement : 6 coarse sand)
Brick Work - G.L. To P.L.
12 7.5.4 + 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 2774.00 + 103.00
Brick Work Above P.L.
Rolling Suter 3 3.65 0.20 3.05 6.68
13 9.27 Supplying and fixing rolling shutter of approved makes made of M.S. laths interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets,side guides and arrangements for inside and out side locking with push and pull arrangement complete but excluding the cost of top cover and spring.
9.27.2 80x1.20mm M.S. Laths
14 9.28 Providing and fixing 27.5cm long wire spring for rolling shutters. 6 6.00
Total 6.00 each 308.00 1848.00
15 9.29 Providing and fixing M.S. sheet top cover for rolling shutter
9.29.1 1.25mm thick
16 9.30 Providing and fixing ball bearing for rolling shutters. 6 6.00
Total 6.00 each 360.00 2160.00
17 9.31 Providing and fixing mechanical device chain and crank operation for operating rolling shutters. 3 3.00
18 11.1 Providing and making 6mm thick cement plaster of mix:
11.1.2 In Cement mortar 1:4 (1 cement : 4 fine sand)
Ceiling Plaster
Slab Projection 1 11.75 0.90 10.58
19 11.2 Providing and making 12mm thick cement plaster of mix:
11.2.4 In Cement Mortar 1:6 (1 cement : 6 fine sand)
Deduction x 0.50
Rolling Shutter 3 3.65 3.05 33.40
20 11.3 Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix:
11.3.4 In Cement Mortar 1:6 (1 cement : 6 fine sand)
Left & Right Side 2 4.40 3.95 34.76
Total Outer Plaster 15mm 120.54
Total outside plaster 120.54
Deduction : x 0.50
Rolling Shutter 3 3.65 3.05 33.40
Total Deductions 33.40
G.Total(A-B) 87.14 sqm 91.00 7929.51
21 12.79 Providing and laying DOUBLE/MULTI CHARGE (minimum 2.0 mm thick layer) VITRIFIED floor tiles with water absorption less than 0.05% and conforming to IS :15622-2017 of 1st quality of approved make in all colours and shades and size mentioned below (+/- 10mm) laid on 20mm thick cement mortar 1:4 (1cement: 4 coarse sand) including grouting the joints with withe cement and matching pigments etc. complete.
21.1 12.79.1 Size 600x600mm thickness 9 to 10mm
Add SKIRTING 10 % 4.38
22 12.50 KOTA stone slab 25mm thick in risers and treads of steps, skirting dado and pillar laid in 12mm (Average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. (single stone is to be used for riser and treads of steps and the width of stone for skirting and dado shall be equal to the height of skirting/ dado up to length of 1.0 M.)
Threshold Steps
In Front of Shop
23 12.51 Extra for nosing in steps and treads of Kota stone slab. 1 35.25 35.25 M 59.00 2079.75
24 14.56 Providing and applying 2mm thick white cement based polymeric Exterior grade Putty with minimum 3 coats applied @ 5.4 kg/ 10Sqm as per relevant IS code 17545 :2021 (Product such as Birla wall care, Asian trucare, JK wall putty, Berger Bison wall putty) to make the surface smooth and even with all tools tackles and labour etc. complete for the work.
Qty. same as 6 mm plaster 1 x 54.38 54.38
Qty. same as 12 mm plaster 1 x 114.63 114.63
Qty. same as 15 mm plaster 1 x 87.14 87.14
25 14.64 Providing and applying Premium plastic emulsion paint with roller application minimum three coats applied @ 0.75 lit / 10Sqm up to final finish as per relevant I.S. Code 15489:2013 Type -1 Class D & C ( Glossy and Semi Glossy Finish) of required shade (Product such as Asian Apcolite Premium , Dulux Super Cover, Berger Easy Clean , Nippon Breezee Metex Gold, Opus I-50 / Calista) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work.(with 3 year Warranty)
Qty. same as putty work 1 x 256.14 256.14
Qty. same as inside 15mm plaster 1 x 87.14 87.14
26 14.68 Providing and applying on exterior surface with PREMIUM Exterior emulsion paint of required shade to give protective and water proof finish minimum 3 coats applied @ 1.40 lit / 10Sqm up to final finish as per relevant I.S. Code 15489:2013 Type -2 Class D , C (Glossy /Semi Glossy finish ) (Product such as Asian Apex , Dulux Weather Shield Prima E900 , Berger Weathercoat Antidust , Nerolac Everlas Excel , Nippon Sumo Etra, Opus True flex) inclusive of providing abro tape on edges and articleand cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work.(With 3Year Warranty.)
Same as 15mm plaster 1 x 87.14 87.14
27 14.72 Providing and applying Glossy finish Enamel paint mimimum 2 coats in all surface applying @ 0.75 lit/ 10 Sqm up to required finish as per relevent I.S. code 2932: 2013 of (Product such as Asian Apcolite Premium Enamel , Dulux Promise Premium Enamel , Nerolac Synthatic Enamel, Opus Prime enamel ) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackle and labour etc. complete for the work.
Rolling Shutter 3 3.65 3.05 33.40
TOTAL 475827.87
ADD 9 % FOR ELECTRIFICATION 42824.51
G. Total 518652.37
E.E. A.E. Sub E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
DIRECTION AND PLACE IDENTIFICATION SIGNS
AS PER ROAD SOR 15.06.26
SN REF ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
Direction and Place Identification signs
1 8.6 Direction and Place Identification signs upto 0.9 sqm size board as per Clause 8.1. Providing and erecting direction and place identification retroreflectrorized sign Digitally Printed over reflectrorized sheeting of required grade confirming to ASTM D 4956 including covering with transparent sheeting (lamination sheeting) to protect from fading and damage due to wheather effect as per IRC:67-2022 made of retro-reflective type sheeting fixed over Aluminum sheeting / Aluminium Composit Material (ACM) Sheeting including application of fluorocarbon coating applied on exposed surface of aluminium to ensure corrosion resistance, supported on a mild steel back frame of ISA 40 x 40 x 5 mm and mild steel angle iron post 75 mm x75 mm x 6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45cm x 60cm, 60 cm below ground level as per approved drawing and painting all exposed components of the signs and supports with primer and 2 coats of epoxy paints or powder coating and the
part of post below ground shall be painted with 3 coats of redoxide paint as per clause 7.2 of IRC:67-2022. (Note: The details of manufacturer, type of sheeting, month and year of installation, project details and other details along with QR code as detailed in clause 13.2 and Annexure-VII of IRC:67-2022 shall be printed on back side of the sign board.)
(I) With Aluminium Sheeting 2mm thick
C Made of Class-A High Intensity Mirco Prismatic Engineering Grade Sheeting of Type I confirming to Table 6.3 of IRC:67-2022 (for ODR & Village Roads)
G. Total 27330.84
E.E. A.E. Sub E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
DIRECTION AND PLACE IDENTIFICATION SIGNS
AS PER ROAD SOR 15.06.26
SN REF ITEM DESCRIPTION NOS. QTY UNIT RATE AMOUNT
1 11.9 Tree Guard with MS Angle Iron and Steel Wire (Providing and fixing tree guard 0.60 meter square, 2.00 meter high fabricated with MS angle iron 30 x 30 x 3 mm, MS iron 25 x 3 mm at 100mm centre to centre and steel wire 3 mm dia. welded and fabricated as per design in two halves bolted together, fixed in ground with P.C.C M-10 of dimensions 150x150x200mm.) 68.00 68.00 Each tree guard 2319.00 157692.00
G. Total 157692.00
E.E. A.E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
CONSTRUCTION OF MANCH
AS PER BUILDING SOR 10.06.26
SN REF ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
1 1.2 Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish upto 1.5 m lift and lead upto 50m (at least 5m away from the dressed area).
Cleaning area 1 5.45 7.10 38.70
2 1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.
1.1.1 In all types of soils.
Column pits Shops
Complete Footing Area 1 5.45 7.10 1.50 58.04
3 1.17 Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M.
Same as qty of excavation 1 x 58.04 58.04
Qty of pcc BELOW GL 1 x 2.50 2.50
Qty of Rcc up to G.L. 1 x 5.83 5.83
Remaining Earth after foundation filling 8.32
4 1.18 Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete.
Remaining Earth after foundation filling 1 x 8.32 8.32
Qty of RCC BEAMS BELOW PL 1 x 3.35 3.35
G.Total (A-B) 1.30 Cum 315.00 407.95
5 3.1 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
FLOOR BASE INCLUDING STAGE
Garbh Grih 1 Area 11.28 0.10 1.13
Below Threshold Steps
Front steps 1 4.24 1.20 0.10 0.51
6 3.2 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. (Note :Excess/ less cement used as per design mix is payable/ recoverable separately)
3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
Column up to G.L.
Column upto P.L.
Threshold Steps
7 3.2.1 + 3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 3539.00 + 83.00
Plinth to Slab Lvl.
Up to G.F. Slab
Statue Pedestal beam
Pedestal Slab 1 1.30 1.05 0.15 0.20
Front 1 area 2.68 0.100 0.27
Side Left & right 2 area 1.88 0.100 0.38
Grabh grih Area 1 2.64 2.30 0.125 0.76
8 3.2.1 + 3.4 + 3.4 Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
8 3.12 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire all complete:
3.12.2 Thermo-Mechanically treated bars FE 500D
Qty of R.C.C. x 105 kg/cum Total 2407.31 Kg 46.00 110736.13
9 3.13 Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including form work.
10 2.1 Providing and fixing form work including centering, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for:
10.1 2.1.1 Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.
Column up to G.L.
Column up to P.L.
Beams Sides multiplied X2
Threshold Steps
Waist Slab 1 4.24 1.40 5.94
10.2 2.1.5 Columns, Pillars, Piers and likes- rectangular or square in shape
Plinth to Slab Lvl.
10.3 2.1.6 Columns, beams & walls- circular or any other geometrical shape other than square and rectangular in all sizes
Plinth to Slab Lvl.
10.3 2.1.7 Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)
Front 1 area 2.68 2.68
Side Left & right 2 area 1.88 3.76
Grabh grih Area 1 2.64 2.30 6.07
10.4 2.1.8 Beams, lintels, cantilevers & walls
Multiplying x2 for sides
Statue Pedestal beam
11 7.5 Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in:
7.5.4 Cement Mortar 1:6 (1 cement : 6 coarse sand)
Brick Work in plinth
12 7.5.4 + 7.6 Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 2774.00 + 103.00
In Super Structure(G.F)
13 9.15 Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.
assuming 27.50kg per sqm. 27.50 x 2.40 66.00
assuming 15.00 kg per sqm. 15.00 x 0.72 10.80
14 9.47 Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately:
14.1 9.47.1 For fixed portion
For Wt. @ 5.0kg/Sqm 3.60
15 9.51 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading shall be paid in basic item):
9.51.1 With float glass panes of 4 mm thickness
G.Total 0.72 sqm 519.00 373.68
16 11.1 Providing and making 6mm thick cement plaster of mix:
11.1.2 In Cement mortar 1:4 (1 cement : 4 fine sand)
Ceiling Plaster
Garbh Grih 1 Area 11.27 11.27
Slab Projection
Front 1 area 2.68 2.68
Side Left & right 2 area 1.88 3.76
Front Column 2 6.29 0.15 3.65 6.88
Grabh grih Area 1 2.64 2.30 6.07
17 11.2 Providing and making 12mm thick cement plaster of mix:
11.2.4 In Cement Mortar 1:6 (1 cement : 6 fine sand)
Deduction X 0.5
Grabh Grih wall
G.Total(A-B) 25.04 sqm 78.00 1953.26
18 11.3 Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix:
11.3.4 In Cement Mortar 1:6 (1 cement : 6 fine sand)
Total Outer Plaster 15mm a 105.21
Total outside plaster 105.21
Deduction : x 0.5
Total Deductions 1.56
19 12.7 Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete.
12.7.1 Size above 200x300mm
Grabh Grih wall
Total Deductions B 2.40
20 12.79 Providing and laying DOUBLE/MULTI CHARGE (minimum 2.0 mm thick layer) VITRIFIED floor tiles with water absorption less than 0.05% and conforming to IS : 15622 -2017 of 1st quality of approved make in all colours and shades and size mentioned below (+/- 10mm) laid on 20mm thick cement mortar 1:4 (1cement: 4 coarse sand) including grouting the joints with withe cement and matching pigments etc. complete.
12.79.1 Size 600x600mm thickness 9 to 10mm
Corridor 1 4.24 2.00 8.48
Garbh Grih 1 Area 11.28 11.28
SKIRTING 10 % 2.03
21 12.50 KOTA stone slab 25mm thick in risers and treads of steps, skirting dado and pillar laid in 12mm (Average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. (single stone is to be used for riser and treads of steps and the width of stone for skirting and dado shall be equal to the height of skirting/ dado up to length of 1.0 M.)
Threshould Steps
Statue Pedestal Top
22 12.51 Extra for nosing in steps and treads of Kota stone slab.
Front Steps 4 4.24 16.96
23 14.56 Providing and applying 2mm thick white cement based polymeric Exterior grade Putty with minimum 3 coats applied @ 5.4 kg/ 10Sqm as per relevant IS code 17545 :2021 (Product such as Birla wall care, Asian trucare, JK wall putty, Berger Bison wall putty) to make the surface smooth and even with all tools tackles and labour etc. complete for the work.
Qty. same as 6 mm plaster 100.85
Qty. same as 12 mm plaster 25.04
Qty. same as 15 mm plaster 103.65
24 14.64 Providing and applying Premium plastic emulsion paint with roller application minimum three coats applied @ 0.75 lit / 10Sqm up to final finish as per relevant I.S. Code 15489:2013 Type -1 Class D & C ( Glossy and Semi Glossy Finish) of required shade (Product such as Asian Apcolite Premium , Dulux Super Cover, Berger Easy Clean , Nippon Breezee Metex Gold, Opus I-50 / Calista) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work.(with 3 year Warranty)
Qty. same as inside 6 mm plaster 1 100.85
Qty. same as inside 12 mm plaster 1 25.04
25 14.68 Providing and applying on exterior surface with PREMIUM Exterior emulsion paint of required shade to give protective and water proof finish minimum 3 coats applied @ 1.40 lit / 10Sqm up to final finish as per relevant I.S. Code 15489:2013 Type -2 Class D , C (Glossy /Semi Glossy finish ) (Product such as Asian Apex , Dulux Weather Shield Prima E900 , Berger Weathercoat Antidust , Nerolac Everlas Excel , Nippon Sumo Etra, Opus True flex) inclusive of providing abro tape on edges and articleand cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work.(With 3Year Warranty.)
Same as 15mm plaster 103.65
26 14.72 Providing and applying Glossy finish Enamel paint mimimum 2 coats in all surface applying @ 0.75 lit/ 10 Sqm up to required finish as per relevent I.S. code 2932: 2013 of (Product such as Asian Apcolite Premium Enamel , Dulux Promise Premium Enamel , Nerolac Synthatic Enamel, Opus Prime enamel ) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackle and labour etc. complete for the work.
Sub Total 408474.08
Add 3% For Electrical Work 12254.22
Total 420728.30
E.E. A.E. Sub E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
SLUICE GATE AT PROPOSED INLET & OUTLET
AS PER CG WRD SOR 2025
SN REF ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
1 8.04 CG WRD SOR 2025 Design, Drawing, fabrication, supply, erection, testing and commissioning of Vertical lift sliding type gate with frame consisting of skin plate, sealing frame, stiffeners, horizontal and vertical girders, guide, stainless steel flat/Brass flat, rivets, wedges, lifting rods etc., with all accessories as per relevant IS code including frame & gate complete set for Canal Cross, Escape, Head regulator /Tank head regulator ,Barrage/Stop dam/Anicut/waste weir /spillway including cost of all materials, machinery, labour, cutting, aligning, welding, finishing, cleaning, seal fixing, tools and tackles etc., applying two
coat of zinc rich epoxy primer to give dry film thickness of 70± 5 microns and finish coat (two coats)of solvent less coal tar epoxy paint using airless spray to provide dry film thickness of 150± 5 microns per coat thus total dry film thickness of all coats, including primer coating, should not be less than 350 microns., complete as per specifications and approved drawings with all lead and lifts, including packing & forwarding, transportation charges for structural steel components and other materials, including all lead and lifts.
Sluice Gate 1 1.00 1.00
2 8.05 CG WRD SOR 2025 Design, Drawing, fabrication, supply, erection, testing and commissioning of Adequate capacity electrically operated rope drum hoist according to relevant IS code , rope drums, connecting shaft, gear system, Reduction gear unit, electric motor, electro- magnetic brake system, control panel, pulleys, wire rope, gate position indicator, limit switch with inbuilt manual operating system, etc. complete, with all accessories for operating gates including cost of all materials, machinery, labour, cutting, aligning, anchoring, welding, finishing, cleaning, greasing, oil filling, tools and tackles, applying two coats of zinc chromate red oxide primer and three coats of approved synthetic enamel paint etc., complete as per specifications and approved drawings , including packing & forwarding, transportation charges for all materials, including all lead and lifts.
Sluice Gate Motor 1 1.00 1.00
Total 1.00 Per tonne capacity 66910.00 66910.00 66910.00
Total cost of 1 sluice gate with motor 274952.00 274952.00
No. of gates required (one each at Proposed Inlet & Outlet) 2.00
Total cost of 2 sluice gates with motor 549904.00
E.E. A.E. Sub E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
DESILTING & POND CLEARANCE
AS PER BUILDING 10.06.26 & ROAD S.O.R. 15.06.26
SN REF ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
Pond Storage area = 53108.45 sqm. 53108.45
1 RS 3.2 Excavation in Soil (by Mechanical Means.) Excavation for roadway in soil using mechanical means including loading in tipper for carrying of cut earth to embankment site and unloading with all leads & lifts as per relevant clauses of section 300.
Pond Excavation
( Note - Pond Excavated 70% Soil Used In Bund Prepration Work ) Total 29740.73 cum 88.00 2617184.42 24.3479128
2 RS 1.1 Transportation of metal i/c loading & unloading
i For a lead upto 1 Km.
ii Beyond 1 Kms. and upto 10 Kms. (Add extra for every 1 Km.)
Transport 30% Qty. of Excavated Soil 1 x 8922.22 8922.22
3 RS 3.9 Removal of Unserviceable Soil Removal of Unserviceable Soil and Disposal with all leads including loading and unloading.
4 BS 1.10 Pumping out water caused by springs tidal or river seepage, broken water main or drains and like during Excavation or during Excavation and laying of base concrete (volume to be calculated taking height from water level to bottom of pit and to be measured and paid) .
Dewatering area -
5 BS 22.2 Supplying and stacking of good earth at site including royalty, loading, unloading and carriage upto 5 km (earth measured in stacks will be reduced by 20% for payment).
Black Cotton Soil Lining Work To Treat Percolation In Pond bed 64% Area
TOTAL 8628848.52
E.E. A.E. SUB E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
CONSTRUCTION WORK OF SEWAGE TREATMENT PLANT
AS PER MP PWD BUILDING SOR VOL - II , 01.01 2024
SN REF ITEM DESCRIPTION Nos. QTY UNIT RATE AMOUNT
1 30.1 Designing and preparing good for construction civil, mechanical and electrical shop drawings of conventional/ package unit of a Sewage Treatment Plant(STP)/ Effluent Treatment Plant (ETP) as per manufacturer/vender's design and specification consisting of treatment units complete for meeting up to date/ target parameters of treated effluent conforming to Madhya Pradesh Pollution Control Board (MPPCB),
MoEF GOI guidelines, National Green Tribunal guideline 30.4.2019 and technical specifications codes of practices as published by the Bureau of Indian Standard (BIS) and latest version of “Manual on Sewerage and Sewage Treatment” published by the Central Public Health And Environmental Engineering Organization (CPHEEO).
The work shall include supplying, installing, testing and commissioning of electro-mechanical equipments, instruments, pipes, valves, pumps, and gauges etc. as per approved technical specifications, layout and drawing of STP/ETP.
Most of the electro-mechanical unit will be placed below ground under road/green area/ as per site condition, space available, equipment and pump room will be above the ground level and civil work RCC (M25) according to the approved shop drawings and direction of Engineer in charge. Civil work shall be paid separately.
Rates are inclusive of cost of operation and maintenance (O&M) for one year after completion of works which include periodical /monthly checking quality of treated sewage, checking of safety arrangements and routine maintenance of plant such as oiling, greasing, cleaning, operating, providing Consumable replacement of components within guarantee period, disposal of dried sludge and also ensuring safety against theft. The STP/ ETP shall comprise of the units of required size as per detail process and hydraulic design.
30.1.2 STP MBBR Package Technology
Package MBBR STP Technology Primary treatment – - Manual Bar Screen -Oil, Grease Trap and Grit Removal System
Secondary treatment – -Raw Sewage Transfer Pump (01set) - Air Blower(01set) and Diffuser System - Anoxic Tank with Agitator - MBBR Tank with Media - Tube/Lamella settler tank with Tube Media -Clear water Tank With Chlorine Dosing system and Chlorine Dosing Pump(01set) -Sump Pump (01set) -Plant/Interconnecting Piping And Valves -Manual/PLC Based Electrical Control Panel
-Incoming/Outgoing Feeder -Cable Laying With Cable Tray -Earthing Systems -Pressure Gauges -Level Switches -Online Rota meter
-Air Rota meter -Flow Meter -Filter Feed Pump (01set) -Multi Grade Sand Filter -Activated Carbon Filter -Micro Filtration system Sludge Handling System- -Sludge Recycling Pump (01set) -Sludge Feed Screw Pump (01set) -Filter Press System
TOTAL 6354750.00
E.E. A.E. Sub E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
CONSTRUCTION WORK OF SEWAGE TREATMENT PLANT
AS PER MP PWD BUILDING SOR VOL - II , 01.01 2024
SN REF ITEM DESCRIPTION Nos. QTY UNIT RATE AMOUNT
1 30.1 Designing and preparing good for construction civil, mechanical and electrical shop drawings of conventional/ package unit of a Sewage Treatment Plant(STP)/ Effluent Treatment Plant (ETP) as per manufacturer/vender's design and specification consisting of treatment units complete for meeting up to date/ target parameters of treated effluent conforming to Madhya Pradesh Pollution Control Board (MPPCB),
MoEF GOI guidelines, National Green Tribunal guideline 30.4.2019 and technical specifications codes of practices as published by the Bureau of Indian Standard (BIS) and latest version of “Manual on Sewerage and Sewage Treatment” published by the Central Public Health And Environmental Engineering Organization (CPHEEO).
The work shall include supplying, installing, testing and commissioning of electro-mechanical equipments, instruments, pipes, valves, pumps, and gauges etc. as per approved technical specifications, layout and drawing of STP/ETP.
Most of the electro-mechanical unit will be placed below ground under road/green area/ as per site condition, space available, equipment and pump room will be above the ground level and civil work RCC (M25) according to the approved shop drawings and direction of Engineer in charge. Civil work shall be paid separately.
Rates are inclusive of cost of operation and maintenance (O&M) for one year after completion of works which include periodical /monthly checking quality of treated sewage, checking of safety arrangements and routine maintenance of plant such as oiling, greasing, cleaning, operating, providing Consumable replacement of components within guarantee period, disposal of dried sludge and also ensuring safety against theft. The STP/ ETP shall comprise of the units of required size as per detail process and hydraulic design.
30.1.2 STP MBBR Package Technology
Package MBBR STP Technology Primary treatment – - Manual Bar Screen -Oil, Grease Trap and Grit Removal System
Secondary treatment – -Raw Sewage Transfer Pump (01set) - Air Blower(01set) and Diffuser System - Anoxic Tank with Agitator - MBBR Tank with Media - Tube/Lamella settler tank with Tube Media -Clear water Tank With Chlorine Dosing system and Chlorine Dosing Pump(01set) -Sump Pump (01set) -Plant/Interconnecting Piping And Valves -Manual/PLC Based Electrical Control Panel
-Incoming/Outgoing Feeder -Cable Laying With Cable Tray -Earthing Systems -Pressure Gauges -Level Switches -Online Rota meter
-Air Rota meter -Flow Meter -Filter Feed Pump (01set) -Multi Grade Sand Filter -Activated Carbon Filter -Micro Filtration system Sludge Handling System- -Sludge Recycling Pump (01set) -Sludge Feed Screw Pump (01set) -Filter Press System
TOTAL 1968323.00
E.E. A.E. Sub E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
CONSTRUCTION OF VERTICAL FLOW CONSTRUCTED WETLAND TANK
AS PER BUILDING SOR 10.06.26
SN REF ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
1 1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.
1.1.1 In all types of soils.
2 1.26 Carriage by mechanical transport upto 5 km lead:
Oty. Same As Item No. 1.1.1 1 x 524.88 524.88
3 3.1 Providing and laying nominal mix cement concrete with crushed stone aggregate using concrete mixer in foundation, plinth and at ground level excluding cost of form work.
3.1 3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
3.2 3.1.5 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
Pcc Top Above Side Stone Wall
4 3.2 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
5 3.12 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete:
3.12.2 Thermo-Mechanically treated bars FE 500D
Qty. Same as RCC 1 x 50.56 50.56
Assuming 40 Kg / Cum 40 x 50.56 2022.48
6 2.1 Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for:
2.1.1 Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.
For PCC Raft Slab
2.1.8 Beams, lintels, cantilevers & walls
7 6.6 Coursed rubble masonry (Second sort) with hard stone in Cement mortar 1:6 (1 cement : 6 coarse sand) upto plinth level.
8 6.6 + 6.7 Extra for Coursed rubble masonry with hard stone (Second Sort) in super structure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 2209.00 + 224.00
Stone Wall, above 0.60 m. stone work
9 21.14 Supplying, filling, spreading & leveling stone boulders/ Gravels/ Coarse sand, in recharge pit, in the required layers and thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (excavation of pit will be paid separately).
9.1 21.14.1 Stone boulders of size range 5 cm to 20 cm, in recharge pit
Drainage Layer 1 13.45 13.45 0.30 54.27
9.2 21.14.2 Gravels of size range 5 mm to 10 mm, over the existing layer of boulders
Transition Layer 1 13.75 13.75 0.60 113.44
9.3 21.14.3 Coarse sand of size range 1.5 mm to 2 mm over existing layer of gravel
Inlet Distribution Layer 1 14.65 14.65 0.60 128.77
10 4.16 Providing and laying 3mm thick APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 ltr/sqm. by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ltr and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under :Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/ 250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147.
On Floor Bed 1 13.30 13.30 176.89
11 4.17 Extra for covering top of membrane with Geotextile, 120gsm non woven, 100% polyester of thickness 1 to 1.25mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation.
Qty. Same as Above 1 x 284.43 284.43
12 3.17 RS Sub Surface Drains with Perforated Pipe Construction of subsurface drain with perforated pipe of 100 mm internal diameter of cement concrete closely jointed, perforations ranging from 3 mm to 6 mm depending upon size of material surrounding the pipe, with 150 mm bedding below the pipe and 300 mm cushion above the pipe, cross section of excavation 450 x 550 mm. Excavated material to be utilized in roadway at site.
E.E. A.E. SUB.E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
CONSTRUCTION WORK OF TREATMENT TANKS
AS PER BUILDING SOR 10.06.26
SN REF ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
(A) COLLECTION CHAMBER
1 1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.
1.1.1 In all types of soils.
2 1.17 Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M.
Same as qty of excavation 1 x 99.86 99.86
Qty of Pcc Base Below GL 1 x 9.36 9.36
Qty of Rcc Raft 1 x 12.29 12.29
Remaining Earth after foundation filling (B) 70.80
Remaining Earth after foundation filling 70.80
3 1.26 Carriage by mechanical transport upto 5 km lead:
Remaining Earth after back filling 1 x 70.80 70.80
4 3.1 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
4.1 3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
5 3.2 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. (Note :Excess/ less cement used as per design mix is payable/ recoverable separately)
3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
6 3.12 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire all complete:
3.12.2 Thermo-Mechanically treated bars FE 500D
7 2.1 Providing and fixing form work including centering, shuttering, strutting,staging, propping bracing etc. complete and including its removal at all levels, for:
7.1 2.1.1 Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.
8 11.1 Providing and making 6mm thick cement plaster of mix:
11.1.2 In Cement mortar 1:4 (1 cement : 4 fine sand)
9 11.5 Neat Cement punning.
10 4.3 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of WC, kitchen and the like consisting of:
i) 1st course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 including rounding off junction of vertical and horizontal surface.
ii) 2nd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound including rounding off junction of vertical and horizontal surface.
iii) 3rd course of applying blown or residual bitumen applied hot @ 1.7 Kg. per sqm of area.
iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg. per sqm of area.
E.E A.E. SUB.E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
CONSTRUCTION WORK OF TREATMENT TANKS
AS PER BUILDING SOR 10.06.2026 & ROAD SOR 15.06.2026
SN REF ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
1 1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.
1.1.1 In all types of soils.
2 1.6.1 Extra for every additional lift of 1.5 m or part thereof. All types of soils
3 1.6.1 Extra for every additional lift of 1.5 m or part thereof. All types of soils 23+ 23
4 1.17 Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M.
Same as qty of excavation 1 x 538.16 538.16
Qty of Pcc Base Below GL 1 x 18.20 18.20
Qty of Rcc Raft 1 x 45.86 45.86
Remaining Earth after foundation filling (B) 291.59
Remaining Earth after foundation filling 291.59
5 1.26 Carriage by mechanical transport upto 5 km lead:
Remaining Earth after back filling 1 x 291.59 291.59
6 3.1 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
6.1 3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
7 3.2 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. (Note :Excess/ less cement used as per design mix is payable/ recoverable separately)
3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
8 3.12 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire all complete:
3.12.2 Thermo-Mechanically treated bars FE 500D
9 2.1 Providing and fixing form work including centering, shuttering, strutting,staging, propping bracing etc. complete and including its removal at all levels, for:
9.1 2.1.1 Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.
9.2 2.1.7 Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)
Form Work For Tank
9.3 2.1.8 Beams, lintels, cantilevers & walls
10 20.13 Replacement of M.S. foot rests in manholes including dismantling concrete blocks and fixing with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) :
20.13.1 With 20x20 mm square bar
Foot Rest, 6 x 20 120 120.00
11 20.14 Supplying and fixing C.I. cover without frame for manholes :
20.14.3 560 mm diameter C.I. cover (heavy duty) the weight of the cover to be not less than 108 kg.
Man Hole Cover 6 6.00
12 11.1 Providing and making 6mm thick cement plaster of mix:
11.1.2 In Cement mortar 1:4 (1 cement : 4 fine sand)
13 11.5 Neat Cement punning.
14 4.3 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of WC, kitchen and the like consisting of:
i) 1st course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 including rounding off junction of vertical and horizontal surface.
ii) 2nd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound including rounding off junction of vertical and horizontal surface.
iii) 3rd course of applying blown or residual bitumen applied hot @ 1.7 Kg. per sqm of area.
iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg. per sqm of area.
15 Road sor 9.7 Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia complying to IS:458, across the road (new construction), extending from drain to drain in cuts and toe of slopes to toe of slopes in fills, excluding constructing head walls at ends, providing a fill of granular material over top and sides of RCC pipes, bedded on a 0.3 m thick layer of granular material free of rock pieces , outer to outer distance of pipes at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts , joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC: 98 and approved drawings.
(i) Single row for one utility service 300 mm dia 1 20.00 20.00
E.E. A.E. SUB.E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
CONSTRUCTION WORK OF SETTLING TANK
AS PER BUILDING SOR 10.06.2026
SN REF ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
1 1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.
1.1.1 In all types of soils.
2 1.6.1 All types of soils
3 1.17 Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M.
Same as qty of excavation 1 132.62
Qty of Pcc Base Below GL 9.36
Qty of Rcc Raft 13.07
Remaining Earth after foundation filling (B) 84.89
Remaining Earth after foundation filling 84.89
4 1.26 Carriage by mechanical transport upto 5 km lead:
Remaining Earth after back filling 1 x 84.89 84.89
5 3.1 Providing and laying nominal mix cement concrete with crushed stone aggregate using concrete mixer in foundation, plinth and at ground level excluding cost of form work.
5.1 3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
6 3.2 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. (Note :Excess/ less cement used as per design mix is payable/ recoverable separately)
3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
Rcc Raft Slab (Tank bottom Slab) 1 6.60 6.60 0.30 13.07
Shorter Wall 2 6.00 0.20 1.525 3.66
7 3.12 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire all complete:
3.12.2 Thermo-Mechanically treated bars FE 500D
8 2.1 Providing and fixing form work including centering, shuttering, strutting,staging, propping bracing etc. complete and including its removal at all levels, for:
8.1 2.1.1 Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.
Form Work For Tank
Inner Side Wall
8.2 2.1.7 Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)
Form Work For Tank
8.3 2.1.8 Beams, lintels, cantilevers & walls
9 20.13 Replacement of M.S. foot rests in manholes including dismantling concrete blocks and fixing with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) :
20.13.1 With 20x20 mm square bar
Foot Rest, 2 x 5 10 10.00
10 20.14 Supplying and fixing C.I. cover without frame for manholes :
20.14.3 560 mm diameter C.I. cover (heavy duty) the weight of the cover to be not less than 108 kg.
Man Hole Cover 2 2.00
11 11.1 Providing and making 6mm thick cement plaster of mix:
11.1.2 In Cement mortar 1:4 (1 cement : 4 fine sand)
Inner Side Wall
Slab Ceiling 1 6.00 6.00 36.00
12 11.5 Neat Cement punning.
13 4.3 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of WC, kitchen and the like consisting of:
i) 1st course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 including rounding off junction of vertical and horizontal surface.
ii) 2nd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound including rounding off junction of vertical and horizontal surface.
iii) 3rd course of applying blown or residual bitumen applied hot @ 1.7 Kg. per sqm of area.
iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg. per sqm of area.
E.E. A.E. SUB.E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
CONSTRUCTION OF VERTICAL FLOW CONSTRUCTED WETLAND TANK
AS PER BUILDING SOR 10.06.2026
SN REF ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
1 1.1 Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.
1.1.1 In all types of soils.
2 1.26 Carriage by mechanical transport upto 5 km lead:
Oty. Same As Item No. 1.1.1 1 x 161.28 161.28
3 3.1 Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.1 3.1.3 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
3.2 3.1.5 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
Pcc Top Above Side Stone Wall
4 3.2 Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work.
3.2.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
5 3.12 Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete:
3.12.2 Thermo-Mechanically treated bars FE 500D
Qty. Same as RCC 1 x 15.04 15.04
Assuming 40 Kg / Cum 40 x 15.04 601.68
6 2.1 Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for:
2.1.1 Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.
For PCC Raft Slab
2.1.8 Beams, lintels, cantilevers & walls
7 6.6 Coursed rubble masonry (Second sort) with hard stone in Cement mortar 1:6 (1 cement : 6 coarse sand) upto plinth level.
8 6.6 + 6.7 Extra for Coursed rubble masonry with hard stone (Second Sort) in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: 2209.00 + 224.00
Stone Wall, above 0.60 m. stone work
9 21.14 Supplying, filling, spreading & leveling stone boulders/ Gravels/ Coarse sand, in recharge pit, in the required layers and thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (excavation of pit will be paid separately).
9.1 21.14.1 Stone boulders of size range 5 cm to 20 cm, in recharge pit
Drainage Layer 1 8.45 4.45 0.30 11.28
9.2 21.14.2 Gravels of size range 5 mm to 10 mm, over the existing layer of boulders
Transition Layer 1 8.75 4.75 0.30 12.47
9.3 21.14.3 Coarse sand of size range 1.5 mm to 2 mm over existing layer of gravel
Inlet Distribution Layer 1 9.65 5.65 0.30 16.36
10 1.18 Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete.
Main Filter media 1 9.20 5.20 0.60 28.70
11 4.16 Providing and laying 3mm thick APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 ltr/sqm. by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ltr and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under :Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147.
On Floor Bed 1 8.00 4.00 32.00
On Longer Wall 2 9.15 1.90 34.77
On Shorter Wall 2 5.15 1.90 19.57
12 4.17 Extra for covering top of membrane with Geotextile, 120gsm non woven, 100% polyester of thickness 1 to 1.25mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation.
Qty. Same as Above 1 x 86.34 86.34
13 3.17 RS Sub Surface Drains with Perforated Pipe Construction of subsurface drain with perforated pipe of 100 mm internal diameter of cement concrete closely jointed, perforations ranging from 3 mm to 6 mm depending upon size of material surrounding the pipe, with 150 mm bedding below the pipe and 300 mm cushion above the pipe, cross section of excavation 450 x 550 mm. Excavated material to be utilized in roadway at site.
E.E. A.E. SUB.E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
BATHYMETRY SURVEY
SN REF ITEM DESCRIPTION NOS. L W H/D QTY UNIT RATE AMOUNT
1 1.126 Topographic survey for Bathymetry Survey of Reservoir using Trimble SPS855 DGPS Receiver, Geomax RTR system and Auto level including geotagging of above, all lead and lifts etc., complete.
North-South direction of Grid
For lengths excl. central island Maximum Lengh of Pond in East-West Direction - approx. 265 m
Length occupied by central island ~ 70 m
Average Lengh of Each Traverse line in N-S direction - 250 m
For lengths incl. central island Maximum Lengh of Central Island in East-West Direction - approx. 70 m
Average Lengh of Each Traverse line in N-S direction excl. length occupied by central island = 250 m - 70 m = 180 m
East-West direction of Grid
For lengths excl. central island Maximum Lengh of of Pond in North-South Direction - 250 m
Length occupied by central island ~ 70 m
Average Lengh of Each Traverse line in E-W direction - 265 m
For lengths incl. central island Maximum Lengh of Central Island in East-West Direction - approx. 70 m
Average Lengh of Each Traverse line in N-S direction excl. length occupied by central island = 265 m - 70 m = 195 m
Total Length to be traversed 23650.00 Meter
2 1.127 Single beam Bathymetry Survey using Bathy 500 Single beam echo sounder and accessories and Hypack data acquisition and survey vessel navigation software package including geotagging of above, all lead and lifts etc., complete.
Qty Same As Above 23.65
Total 23.65 Lkm 2500.00 59125.00 North
3 1.128 Sedimentation Studies using Sub Bottom profiler including geotagging of above, all lead and lifts etc., complete. (West) 250 m O 250 m (East)
Qty Same As Above 23.65 265 m
Total 23.65 Lkm 5000.00 118250.00 South
TOTAL 229405.00
E.E. A.E. SUB.E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
MACROPHYTES PLANTS
Non Sor (HORTICULTURE & LANDSCAPING DSR 2025)
SN ITEM DESCRIPTION NOS. QTY UNIT RATE AMOUNT
1 Providing, stacking and Displaying Canna dwarf of height 25 to 30 cm., 2 to 3 suckers in 20 cm Earthen Pot/Plastic Pot and as per direction of the officer-in-charge.
E.E. A.E. Sub.E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
Non Sor (GEM Portal)
SN ITEM DESCRIPTION QTY UNIT RATE AMOUNT
1 VETIVER SLIPS
Specifications Types - Non seedling type Plant Height - 6 Inch Number of tillers per slip - 1 Packing Type - Bare-root Root size(In Inch) - 1
Description : Vetiver slips are deep rooted parts of vetiver grass. They are planted to control soil erosion, stabilize slopes, improve land and conserve and purify water.
Technical Name : Chrysopogon zizanioides Common Name : Khus Family : Poaceae
Pest/Disease Free : Yes Shelf Life : Agree to supply the product with at least 75% residual shelf life at the time of material supply.
Compliance with ICAR / State Agriculture Guidelines : Yes Agree to provide all relevant documents, Test Report/Supporting document / reports etc to the buyer at the time of bidding or on demand : Yes
Length of pond water edge - 1394.90 m.
Spacing Between Plant - 0.10 m, to 0.15 m. , take 0.15 m. space
Qty of plant use in One Row= 1394.90 / 0.15 = 9299.00 Nos.
Take 3 rows so total Qty. = 9299 x 3 = 27897.00 nos. 27897.00 Each 30.00 836910.00
Total 836910.00
E.E. A.E. Sub.E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
Floating Wetlands
Non Sor (As Per Quotation) 132.771125
SN ITEM DESCRIPTION QTY UNIT RATE AMOUNT 92.20217014
1 Floating Treatment Water Wetlands
Product Specifications
Dimension - (L*W*H) 1.2 m x 1.2 m x 0.4m Meter (m) Application - Used for improving water quality, beautification of water bodies and restore the eco-system. Product Type - Floating Wetlands (floating structure) Payment Terms - Cash in Advance (CID), Cheque, Cash Advance (CA) Supply Ability - 100 Per Month Delivery Time - 45 Days Packaging Details - The Price mentioned is exclusive. Packaging ,transport cost and additional accessories like plants, chains, etc. will be charged. Main Domestic Market - All India Product Unit - 5 Piece/Pieces Moq - 1 Packsize - 1 Price 50000.00 INR (Approx.) Stock Quantity - 15 Unit Type - Piece/Pieces Currency - INR Mop - 1 Returnable - No Brand Name Clean-Water Price Type - fixed Minimum Order Quantity - 1 Minimum Ordered Packs - 1 GSTIN - 0%
Total 5060000.00
E.E. A.E. Sub.E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
3D ARTISTIC PAINTING
NON SOR (Raipur Smart City)
SR. Description of items Nos. L B H Qty. Unit Rate Amount
1 3D FORMAT ARTISTIC PAINTING
On Brick Boundary Wall 1 224.52 1.65 370.458
Total 481595.40
E.E. A.E. SUB E. ARCHITECT
AR. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
KID'S PLAYING EQUIPMENT & GYM EQUIPMENT
As Per Gem Portal
SN ITEM DESCRIPTION NOS. QTY UNIT RATE AMOUNT
A KID'S PLAYING EQUIPMENT
Outdoor Slide with Curved (Spiral) design surface made of Galvanized Steel Material
Gem (Product id : 5116877-41861281497
Specifications Design of the Slide Surface - Curved (Spiral) Warranty - 1 Year Material of the Slide Surface - Galvanized Steel Material of the Platform with Side Hand Rails,Platform and Ladder - Galvanized Steel Material of the Frames (Support Legs) - Galvanized Steel Diameter of the Frames (Support Legs) - 3.6 inch to 4.5 inch Overall Length of the Slide - 15.1 feet to 20 feet Overall Height of the Slide - 5 feet to 8 feet Width of the Sliding Surface - 1.5 feet to 2 feet Overall Weight of the Slide - 251 kg to 300 kg
2 Outdoor Slide with Straight design surface made of FRP Material
Gem (Product id : 5116877-65764500980
Design of the Slide Surface : Straight Warranty : 1 Year Material of the Slide Surface : FRP Material of the Platform with Side Hand Rails,Platform and Ladder : Galvanized Steel Material of the Frames (Support Legs) : Galvanized Steel Diameter of the Frames (Support Legs) : 3.6 inch to 4.5 inch Overall Length of the Slide : 25.1 feet to 30 feet Overall Height of the Slide : 5 feet to 8 feet Width of the Sliding Surface : 2.6 feet to 3 feet Overall Weight of the Slide : 50 kg to 100 kg
3 2 Seater Single Bar Seesaw for Playground
General Requirements of the Play Ground Seesaw Conforming to : Play Ground Seesaw for Schools - The equipment conforming to IS 8404 : Part 1 Material of the Seesaw : Iron Type of Play Ground Seesaw : Traditional Type Seater Type ; 2 Seater Single Bar Seesaw Overall Length of the Seesaw ( In ft) : 5 ft to 6 ft Overall Width of the Seesaw ( In ft) : 3.1 ft to 4 ft Overall Height of the Seesaw ( In ft) : 2.6 ft to 3 ft
4 Platform Merry Go Round with total children capacity of 6
Basic primary Components Included in a Merry Go Round for Play Ground Set : Platform, Seats, Handrails/Frames, Central Axis, Bearings, Base Frame, Fasteners etc., applicable as per the selected type in Platform Merry Go Round, Seated Merry Go Round with Platform or Seated Merry Go Round without Platform
Types of Playground Merry Go Round : Platform Merry Go Round
No of children capacity on the platform / Total seating capacity : 6
Material of the Seat in the case of Seated Merry Go Round With Platform and Without Platform : NA ( In case of Platform Merry Go Round)
Load capacity of Platform Merry Go Round / Individual seat ( In Kg) : Min 30 kg
Overall Diameter of Playground Merry Go Round (In Meter "m") : 1.5 m to 2 m
Height from the Ground Level to Bottom of Seat/Platform : 0.9 m to 1.2 m
Design and Appearance of the Play Ground Merry Go Round : As per the catalog Images uploaded
5 Parallel Bars for Gymnastics
Name of the Product : Parallel Bars for Gymnastics
Description : The apparatus consists of two bars of equal dimensions, which run parallel and at the same height.
Utility ; Training
Cross section of the Bars (Rails ) : Drop like profile/Oval Profile
Bars profile-Vertical Axis : 5 cm 卤 1 mm
Bars profile-Horizontal Axis : 4 cm 卤 1 mm
Profile of bars (Rails) : Profile of bars (Rails) shall remain unchanged throughout the length
Upper surface of the bars : The upper surface of the bars must be hygroscopic, and not be slippery.
Length of Bar (Rails) : 350 cm 卤1 cm
Distance between points of attachment with Upright Supports : 230 cm 卤1 cm
Height of upper edge measured from the floor near to the supports : Adjustable from 150 cm to 200 cm
Materail of bars (Rails)- Surface
Materail of bars (Rails)- Core : Fibre Glass
UPRIGHT SUPPORTS
Distance between the columns ( Upright Supports ) at adjustment levels, min : 48 cm
Distance between bars (Rails) : Adjustable from at least 42 cm to 52 cm
Material of Upright Supports : Stainless Steel
Portability : Yes
Material of the Base Frame : Stainless Steel
Stability : Base shall provide stability to parallel bars
Colour of remaining material other than bar As per buyer's requirement
ADJUSTMENT DEVICES
The adjustment devices: locking The adjustment devices must be double locked to assure that they do not cede during use.
The adjustment screws must be warranted against unintended adjustments Yes
OTHER REQUIREMENTS
Parallel Bars must not have sharp corners of edges or any protruding parts : Yes
Bar Elasicity : The bars must have elasticity and to assure the efficiency of the elasticity, the fixing points of the bars on the uprights must be articulated.
No significant swaying of bars in the longitudinal and transversal sense must occur : Yes
PERFORMANCE REQUIREMENTS
Performance Requirements as per International Gymnastics Federation ( FIG ) norms/ Rules : Static traction stress test,Stress by pendulum swing test,Oscillation damping test,Lateral stability test,Not Applicable
Product confirming to International Federation requirements i e International Gymnastic Federation ( FIG ) : Yes
Certification from International Federations i e International Gymnastic Federation ( FIG ) : ALL VALID
Warranty ( years ) : 1
6 2 Seater Garden Swing with seat without roof
Seat (with integrated back rest) made up of : Fibre Reinforced Plastic Seat thickness (FRP) ; 3 mm Roof made up of : No roof Roof thickness (FRP) : No roof Roof supported by : N.A Whole assembly of roof supported by (4-Legs) : N.A Seat and Backrest Consist of : N.A Swing suspended with : Hot dipped galvanized chains with wire dia of 4.7 mm Structure : Swing with seat without roof Roof shape No roof Provision of side bars in legs (for leg strengthening) Yes Seat with arm No Provision of back cushion No Provision of seat cushion No Seating capacity 2 - seater Weight bearing capacity in KG 205 FRP roof should be N.A Colour of seat As per buyer’s choice Warranty period in number of : years 1 Test reports to be furnished to buyer on demand : No OEM of offered product is ISO 9001:2015 certified : Yes OEM of offered product is ISO 14001:2015 certified : No
B GYM EQUIPMENT
Type : Single Maximum User Weight ( Kg ) : 110 kilogram Governing Specification for GI Pipes : BIS specification No IS 1161:2014, latest All the GI Pipes are ISI marked : Yes Main Frame : 80mm Nominal Bore G.I. Pipe Main Frame Pipe, Class as per IS 1239 : Medium leg movement frame : 32mm Nominal Bore G.I. Pipe Leg Movement Frame Pipe, Class as per IS 1239 : Medium Handle Frame : 25mm Nominal bore G.I. pipe Handle Frame Pipe, Class as per IS 1239 : Medium Bearings : Ball Bearing, Foot Rest : Fibre Reinforced Plastic MS Foundation Plate Thickness : 10 millimeter Foundation Pipes with anchoring : 500mm deep GI Pipe, supported with M.S. Angle 25 X 25 X 4mm Nominal Bore of Foundation Pipe : 80mm Foundation Pipe, Class as per IS 1239 : Medium Installation : Included Certfication ( Safety and Quality Requirements ) : As per European Standard EN 16630, Warranty ( years ) : 3 year
8 Chest Press Equipment
Type Chest Press : Double
Maximum User Weight ( Kg ) : 100 kilogram
Governing Specification for GI Pipes : BIS specification No IS 1161:2014, latest
All the GI Pipes are ISI marked : Yes
Main Central Pipe : 125 mm Nominal Bore G.I. Pipe
Main Central Pipe, Class as per IS 1239 : Medium
Handle Frame : 40mm Nominal bore G.I. pipe
Handle Frame Pipe, Class as per IS 1239 : Medium
Seat Frame : 40mm Nominal Bore G.I. Pipe
Seat Frame Pipe, Class as per IS 1239 : Medium
Connecting Links : 32mm Nominal Bore G.I. Pipe
Connecting Links Pipe, Class as per IS 1239 : Medium
Foot Rest Pipe : 32mm Nominal Bore G.I. Pipe
Foot Rest : Pipe, Class as per IS 1239Medium
MS Foundation Plate Thickness : 12 millimeter
Foundation Pipes with anchoring : 500mm deep GI Pipe, supported with M.S. Angle 25 X 25 X 4mm
Nominal Bore of Foundation Pipe : 150mm
Foundation Pipe, Class as per IS 1239 : Medium
Seat and Back Rest : 6mm thick, Fibre Reinforced plastic with uniform bending radius to avoid sharp edges
Bearings : Tapered Roller Bearing
Installation : Included
Certfication ( Safety and Quality Requirements ) : As per European Standard EN 16630
Warranty ( years ) : 2 year
Push Up Bar Handle Length : 180 millimeter
Pushup Bar Handle Height ( one side ) : 120 millimeter
Pushup Bar Handle Height ( other side ) : 120 millimeter
Cross Section of Push Up Bar Handle Pipe : Hollow Tube
Thickness of Push Up Bar Handle Pipe : YES
Pushup Bar Handle Pipe Outer Diameter : 22.3 millimeter
Width of Push up bar Base : 152 millimeter
Push Up Bar Grip Length : 135 millimeter
Push Up Bar Grip Outer diameter : 32 millimeter
Push Up Bar Grip Thickness : 3.6 millimeter
Material of Push Up Bar Handle : Chrome Plated Steel
Material of Push Up Bar Grip : EVA Foam
Material of Base : Chrome Plated Steel with Anti Skid Rubber Feet
10 Shoulder Builder
Type :Two Wheel
Governing Specification for GI Pipes : BIS specification No IS 1239 ( Part 1 )- 2004, latest
All the GI Pipes are ISI marked : No
Main Central Pipe construction : 100mm Nominal Bore G.I. Pipe
Main Central Pipe, Class as per IS 1239 : Medium
Ring ( Wheel ) : 32mm Nominal Bore G.I. Pipe
Ring ( Wheel ) Pipe, Class as per IS 1239 : Medium
Pipe of Spokes of Wheel : 20mm Nominal bore G.I. pipe
Pipe of Spoke of Wheel , Class as per IS 1239 : Medium
Connector Pipe ( between Main Central Pipe and Wheel ) : 32 mm Nominal bore G.I. pipe
Connector Pipe, Class as per IS 1239 : Medium
MS Foundation Plate Thickness : 10 millimeter
Foundation Pipes with anchoring : 750mm deep GI Pipe, supported with M.S. Angle 25 X 25 X 4mm
Nominal Bore of Foundation Pipe : 100mm
Foundation Pipe, Class as per IS 1239 : Medium
Bearings : Ball Bearing
Warranty ( years ) : 2 year
11 Triple Twister ( Three standing )
Type : Triple Twister ( Three standing ) Maximum User Weight ( Kg ) : 120 kilogram Governing Specification for GIPipes : BIS specification No IS 1239 ( Part 1)- 2004, latest All the GI Pipes are ISI marked ; Yes Main Central Pipe : 125 mm Nominal Bore G.I. Pipe Main Frame Pipe, Class as per IS1239 : Heavy Main Central Pipe ( As per Clause3, of IS 1161 ) Nominal Bore & Wall Thickness 125 mm NB with 4.5 mm Thickness
12 Leg Press -Outdoor Gym Equipments Leg Press Double
Type : Leg Press Double Maximum User Weight ( Kg ) : 120 kilogram Governing Specification for GIPipes : BIS specification No IS 1239 ( Part 1)- 2004, latest All the GI Pipes are ISI marked : Yes Main Central Pipe : 100mm Nominal Bore G.I. Pipe Main Central Pipe, Class as per IS1239 : Medium Moving Frame Pipe : 40mm Nominal bore G.I. pipe Moving Frame Pipe, Class as per IS : Medium
13 Air Walker/ Stroller Double
Type : Double Maximum User Weight ( Kg ) : 120 kilogram Governing Specification for GIPipes : BIS specification No IS 1239 ( Part 1)- 2004, latest All the GI Pipes are ISI marked : Yes Main Frame : 125 mm Nominal Bore G.I. Pipe Main Frame Pipe, Class as per IS1239 : Medium leg movement frame : 32mm Nominal Bore G.I. Pipe
14 LCD Cross Trainers, Frame Warranty :- 2 year
Type : Double Maximum User Weight ( Kg ) : 120 kilogram Governing Specification for GIPipes : BIS specification No IS 1239 ( Part 1)- 2004, latest All the GI Pipes are ISI marked : Yes Main Frame : 125 mm Nominal Bore G.I. Pipe Main Frame Pipe, Class as per IS1239 : Medium leg movement frame : 32mm Nominal Bore G.I. Pipe
TOTAL 461473.74
E.E. A.E. Sub.E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
As Per Gem Portal
SN ITEM DESCRIPTION NOS. QTY UNIT RATE AMOUNT
1 SEATING BENCHES
Product id : 5116877-33104147155 Seating Capacity : 3 Seater Stand/Legs Design : Decorative Finsh : Powder Coating Back Rest : With Arm Rest : With Warranty : 1 year Weight Bearing Capacity : 150 kilogram
Material Side Frame Material : Cast Iron Seat Material : Mild Steel Pipe 14 Gauge Back Rest Material : Mild Steel Pipe 14 Gauge Technical Parameters Bench Type : Integrated Seat and Back Seating Capacity : 3 Seater Stand/Legs Design : Decorative Finsh : owder Coating Back Rest : With Arm Rest : With Colour of Seat and Back : As per buyer's Choice Dimensions Total Height : 750 millimeter Seat Height : 450 millimeter Width : 550 millimeter Total Area Required : 1350 millimeter Generic Warranty : 1 year Weight Bearing Capacity : 150 kilogram
Weight Bearing Capacity150 kilogram
TOTAL 224000.00
E.E. A.E. Sub.E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
As Per Gem Portal
SN ITEM DESCRIPTION NOS. QTY UNIT RATE AMOUNT
1 FROSTY HDPE Pole-Mounted Outdoor Dustbin
Type of Dustbin
GroundAnchored -Bins Fixed onPoles
Mounting Configuration - 2 Bins Mounted with 3 Pole
Capacity of each Bin (In Liters) - 70 liter
Material of Container - HDPE
Material of Support Structure/Pole - Mild Steel asper IS 2062(PowderCoated)
Type of Container/Bin Wall - Perforated
Rain Protection Roof/Canopy - Provided
TOTAL 104000.00
E.E. A.E. Sub.E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
FLOATING AERATOR
NON SOR AS PER GEM PORTAL
SN ITEM DESCRIPTION QTY UNIT RATE AMOUNT
1 Floating Aerators
Automatic Grade Oxygen Transfer capacity(Minimum) (Under standardoperating conditions) 1.5kg/HP/Hr Generic Type - Surface floating Material Specifications Mounting - On a corrosion proof FRP lined MS float with 3mm thick FRP lining Float and diffusion head- Stainless steel Shaft, Propeller and Impeller nut - SS-304 Floating Aerator Specifications Power,HP - 10 Oxygen Transfer capacity (Minimum) (Under standard operatingconditions) - 1.5kg/HP/Hr Circle of influence Diameter - 8 millimeter Drive Specifications Coupling - Motor is to be coupled with the propeller with an appropriatecoupling to withstand the impact load,Ventilated water shieldingcanopy to protect motor from rain drop. Motor Power - 415 Volt
Drive Specifications Typ - TEFC Flame Proof with insulation class B/F IP-55 type suitable for ClassI, Division I, Group IIA and IIB duly approved by CCE as per IS 325, IS2148 with suitable Motor Speed,rpm - 1440 Motor Phase - 3 Aerator Speed,rpm (approx) - 1440 Impeller Propeller Non clog type Energy Efficient induction - 50 Hertz Additional Specifications Additional Information (if not mention "NA") - NA Installation Service - No
Existing DO conc. 4.35 mg/L
Target DO conc. 4.5 mg/L
3 Each 495000.00 1485000.00 Capacity post rejuvenation 178444 KL
Increase in DO 0.15 mg/L
TOTAL (A) 1485000.00 Oxygen required for DO enhancement 26766.6 g
Oxygen requirement 26.7666 Kg
Oxygen transfer requirement assuming 65% aerator efficiency 41.17938462 Kg
Oxygen transfer rate for 10 operating hours per day 4.117938462 Kg/h
No. of aerators required having oxygen transfer capacity of 1.5 Kg/h 2.745292308 Nos
Recommended nos. 3
E.E. A.E. Sub E. ARCHITECT
AR. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
SN ITEM DESCRIPTION QTY UNIT RATE AMOUNT
1 1. Item-Wise Rate Analysis (Material & Fabrication) The cost of stainless steel is typically calculated per kilogram. In the Raipur market, SS 304 grade currently ranges from ₹220 to ₹350 per kg. Item Description Estimated Quantity Rate (per kg/unit) Total Estimated Cost SS 304 Raw Material (Sheets & Tubes) ~900 kg ₹240 – ₹280 ₹2,16,000 – ₹2,52,000 Fabrication Labor (Welding, Finishing) Lumpsum ~20% of material ₹45,000 – ₹55,000 Flooring (Aluminum Chequered Plate) 7.2 sq. m ₹1,200/sq. m ₹8,500 – ₹10,000 Electricals & Plumbing (LEDs, Wiring, Sinks) Lumpsum ₹15,000 ₹15,000 Misc. Hardware (Locks, Hinges, Glass) Lumpsum ₹10,000 ₹10,000 Subtotal (Structure Only) ₹2,94,500 – ₹3,42,000
2. Amenities & Equipment Cost A "miscellaneous street food" setup requires standard commercial-grade SS equipment: 2-Burner Cooking Range (High Pressure): ₹12,000 – ₹18,000. Exhaust Hood with Ducting: ₹15,000 – ₹22,000. Storage Shelves & Cabinets (Built-in): ₹20,000 – ₹35,000. Deep Fryer / Griddle (Optional): ₹8,000 – ₹15,000. Estimated Equipment Total: ₹55,000 – ₹90,000.
3. Transportation Cost (Chhattisgarh Region) For a heavy unit (~1,200 kg), a Light Commercial Vehicle (LCV) or a 14ft truck is required. Local Charges (within 50-100km): Local transporters in Raipur like Sawant Transport or Tannu Packers charge approximately ₹10 – ₹25 per km. Loading/ Unloading (Crane/Labor): Moving a fixed kiosk requires a crane or 4-6 laborers, costing roughly ₹3,000 – ₹5,000. Estimated Transport Total: ₹5,000 – ₹10,000
4. Overall Cost Summary Cost Head Estimated Amount (INR) Main Structure & Fabrication ₹3,15,000 Internal Amenities & Equipment ₹75,000 GST (18%) ₹70,200 Transportation & Installation ₹8,000 Final Estimated Project Cost ₹4,68,200
TOTAL 1872800.00
E.E. A.E. Sub.E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
OPERATIONS & MAINTANACE (labour)
SN General Category Type NOS. Period (month) QTY RATE AMOUNT
Unskilled ( अर्धकुशल ) Guard. 1 60 60.00 11532.00 691920.00
Sweeper/ cleaning 1 60 60.00 11532.00 691920.00
Sub Total (A) 2075760.00
High skilled ( उच्चकुशल ) STP Maintenance,Aerator, eletrification and plumbing 1 60 60.00 13092.00 785520.00
Sub Total (b) 785520.00
Total (a+b) 2861280.00
5-year Operation & Maintenance Cost
S.No. Cost Head Cost for 1 year Cost for 5 years Remarks
1 Manpower cost (incl. maintenance for Wetlands) 2861280 Calculation above
2 Power cost of aerators 129600 648000 Assumed @ 7.5 KWh per hour of operation and 6 operating hrs/day with power cost as 8 Rs/KWh
3 Water Quality analyses cost 36000 180000 One sample per month at 3000 Rs/sample for the required parameters
4 Repair & maintenance of aerators 37125 185625 Assumed as 2.5% of aerator cost per year
C.M.O. SUB E. ARCHITECT
Ar. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
SR. Description of items Unit Qty. Rate Amount
2 External IR Illuminator 1 Each 28000.00 28000.00
3 OFC Cable (6 Core) 600 Metre 36.00 21600.00
4 Cat 6 Cable 400 Metre 36.00 14400.00
6 Gigabyte Single mode SFP Module 2 Each 8000.00 16000.00
7 Fiber patch chord 10 Each 1100.00 11000.00
8 OFC Laying 200 Metre 39.00 7800.00
9 Laying Of Cat 6 Cable 150 Metre 38.00 5700.00
Total 131300.00
G.Total 154934.00
E.E. A.E. SUB E. ARCHITECT
AR. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
SR. Description Specification Unit Qty. Rate Amount
1 Grid-tied inverter 5 kW BIS-certified 1 Each 57500.00 57500.00
2 DC Distribution Box (DCDB) 1 set, SPD & fuses 1 Set 4500.00 4500.00
3 AC Distribution Box (ACDB) 1 set, MCB & isolator 1 Set 6500.00 6500.00
4 Solar Cables UV-resistant, 4 sqmm 200 Metre 75.00 15000.00
5 MC4 connectors IP67-rated 60 Pair 85.00 5100.00
6 Earthing kit GI pipe/ chemical (3pits) 3 Each 4200.00 12600.00
7 Lightning arrestor Rooftop type 1 Each 8500.00 8500.00
8 Net meter (bi-directional), DISCOM-approved 1 Each 6800.00 6800.00
Sub Total 116500.00
Add 18% GST 20970.00
G. Total 137470.00
E.E. A.E. SUB E. ARCHITECT
AR. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
WATER QUALITY TEST
Sr.No Particulars Qty Unit Rate Amount
1 COST TOWARDS WATER QUALITY ANALYSIS (From Certified NABH LAB)
Key Water Quality Parameters pH Levels: Turbidity: Dissolved Oxygen (DO): Total Dissolved Solids (TDS): Microbial Contamination (Coliforms):
For Pond Water body 12 each 3000.00 36000
E.E. A.E. SUB E. ARCHITECT
AR. Rohit Marathe
NAGAR PALIK NIGAM DHAMTARI (C.G.)
REJUVENATION OF WATER BODY UNDER AMRUT 2.0, MAKAI TALAB, DHAMTARI
NON SOR ABSTRACT
S.NO. PARTICULARS AMOUNT
1 CONSTRUCTION WORK OF STP MBBR PACKAGED TECHNOLOGY (AS PER MP PWD BUILDING SOR VOL. II, 01.01.2024) 0.00
2 MACROPHYTES PLANTS 0.00
3 MACROPHYTES PLANTS 0.00
4 VETIVER PLANTS 836910.00
5 3D ARTISTIC PAINTING 481595.4
6 KIDS PLAY EQUIPMENT & GYM EQUIPMENT 461473.74
7 SEATING BENCH 224000.00
8 OUTDOOR DUSTBIN 104000.00
9 FLOTING AERATORS 0.00
10 VENDOR SHOP 1872800.00
11 OPERATIONS & MAINTANACE #REF!
12 CC. TV. CAMERA (NON SOR ITEMS) 154934.00
13 SOLAR PANEL AMENITIES 137470.00
14 POND WATER LAB TEST 36000.00
SUB TOTAL #REF!
ADD CONTINGENCY & ARCHITECTURAL CONSULTANCY FEE @ 2.50% #REF!
E.E. A.E. SUB .E. ARCHITECT
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.02 MB
2344841626286221636_202556_Dhamtari NIT.pdf
NIT • 0.27 MB
1736241759431253747_202556_Tender Notice (1).docx
NIT • 0.02 MB
4344355752573592325_202556_Draft_WBR tender_Dhamtari_Makai Talab.docx
NIT • 2.71 MB
4625062523582780839_202556_Dhamtari WB-Layout Drg.pdf
NIT • 20.74 MB
3040070393147990632_202556_Main NIT.pdf
NIT • 0.53 MB
5692915651808451544_202556_MAKAI TALAB Revised Cost Estimate- 01082026.xlsx
BOQ • 2.76 MB
4659290662857726338_182605_Dhamtari Corrigendum _Addendum 2.pdf
Attachment • 0.14 MB
5070508481143608562_182541_Dhamtari-Makai Talab WB.pdf
Attachment • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .