Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹21.1 LAccepted-AOC 852 EKTA VIHAR 1 C NEAR ANAND NAGAR 9 B PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | 1 | Accepted-AOC LOWEST AND REASONABLE | |
| 2 | 2₹21.4 L+₹32,750 (1.55%)Rejected-Finance | 2 | Rejected-Finance NOT LOWEST | |
| 3 | 3₹21.5 L+₹42,600 (2.02%)Rejected-Finance | 3 | Rejected-Finance NOT LOWEST | |
| 4 | 4₹21.7 L+₹57,540 (2.73%)Rejected-Finance | 4 | Rejected-Finance NOT LOWEST | |
| 5 | 5₹22.6 L+₹1.5 L (7.32%)Rejected-Finance | 5 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
9 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJOR ANIMESH TRIPATHI
GE NORTH PATIALA MILITARY ENGINEER SERVICES SANGRUR ROAD PATIALA CANTT
CLEANING AND MAINTENANCE OF SEWAGE NETWORK IN OLD CANTT UNDER AGE B R II OF GE N AT MIL STN PATIALA
2021_MES_457801_1
GE(N)/PAT-31/2021-22
Open Tender
Civil Works
Item Rate
330 days
PATIALA
AS PER NIT
8 documents required · 8 mandatory
₹500
GE NORTH PATIALA
₹40,000
Yes
23 Aug 2021
7 Jul 2021
11 Aug 2021
7 Jul 2021
9 Aug 2021
22 Jul 2021
60 days
Amount
Cleaning of under ground sewage network including manholes obstruction free by removing sludge and any type of blockage in any kind of manhole or lines including removing blockage inside the building from EWC/WC/floor trap/gully trap etc in old cantt area by deploying adequate manpower and suitable T&P so as to avoid damage to the line/structure complete all as specified and as directed by engineer in charge.
Note:- (i) Sewage network under old cantt area consists appx 15.0 Km long (Dia of pipe up to 200mm-11.00 Km & Dia of pipe exc 200mm but n. exc 600mm-4.00 Km) (ii) Contractor or his rep will report daily at complaint cell of old cantt at 9.00 AM for collection of complaints from the concerned JE's Incharge, on failure a penalty of Rs. 500/- per day in addition to delay in attending the complaints will be charged. A seperate muster roll register will be maintained in AGE office. (iii) Immediately after lodging daily complaints by the users or directed by the EIC consequent to his routine check, the concerned JE shall intimate/hand over the complaint to the contractor or his rep for attending complaints to the satisfaction of user / Engineer-in-charge within 24 Hrs. In case of failure to attend the complaint within specified period, a penalty of Rs.100/- per day per complaint shall be imposed on the contractor for the period the work remains incomplete. After 03 days from the date of handing over of complaint, the unattended complaints shall be got completed from any other agency at the risk and cost of the contractor without any notice to the contractor. In case of disputes as to delay happened in attending the complaint or inadequate period, decision of Accepting Officer shall be final, conclusive and binding.
Cleaning the sewage sump wells, septic tanks of any dia depth and in any location etc by taking out complete sludge water and solids mechanically by HCV mounted suction discharge machine having flow back facility with sludge tank of adequate capacity removing & disposing the entire retrieved material to a distance not exceeding 1000 meter outside the periphery of defence land and covering the entire sludge with local earth complete all as directed by the engineer-in-charge. Note : Depth of sludge in the pit shall be measured from the bottom of pit to the existing water/effluent lever prior to ordering the cleaning in the presence of Engineer-in-Charge.
Material and Labour for Excavation in trenches in soft/loose soil not exceeding 1.50 Mtr wide and not exceeding 1.50 Mtr in depth and getting out in soft/loose soil complete all as specified and as directed by engineer in charge.
All as per Serial items No. 3 herein before but exceeding 1.5 Mtr and not exceeding 3.00 Mtr depth complete all as specified and as directed by engineer in charge. Note :- The rate quoted should include provision of oxygen cylinder , safety belts and helmet in case of deep earth work as and when necessary.
Demolition of Brickwork of stone/boulder masonry, build in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and as directed by engineer in charge.
Material and Labour for Brick work using Sub Class "B" brick straight or curved on plan not exceeding 6 Mtr means radius built in CM 1:4 complete all as specified and as directed by engineer in charge.
All as per item no. 6 above but using old Bricks complete all as specified and as directed by engineer in charge.
Taking down cement plaster on brick walls built in cement mortar including raking out joints and concrete surfaces as in wall or ceiling etc. including hacking for key, scrubbing down with water etc complete all as specified and as directed by engineer in charge.
Material and Labour for Cement plaster 15mm thick on fair faces of brick wk in cement mortar 1:4 and finished even and smooth without using extra cement with/without WPC complete all as specified and directed by Engr-in-Charge (WPC where required shall be measured and paid separately)
Material and Labour for Cement concrete (1:2:4) type B-1 using 20mm graded machnically crushed stone agg as in benching of manholes coping plinth course bands stops etc incl necessary form works complete all specified and directed by Engineer-in-Charges
Demolition by breaking up drain pipes salt glazed stone ware pipe, AC or reinforced concrete of internal dia 100mm dia jointed in cement mortar and taking out of from trenches removing the debries from site complete all as specified and directed by Engineer-in-Charge
Demolition by breaking up drain pipes salt glazed stone ware pipe, AC or reinforced concrete of internal dia 150mm dia jointed in cement mortar and taking out of from trenches removing the debries from site complete all as specified and directed by Engineer-in-Charge
Demolition by breaking up drain pipes salt glazed stone ware pipe, AC or reinforced concrete of internal dia 200mm dia jointed in cement mortar and taking out of from trenches removing the debries from site complete all as specified and directed by Engineer-in-Charge
Material and Labour for Reinforced concrete pipes of 150mm dia, class NP3, laid and jointed complete with collars and jointed complete in cement mortar (1:1) complete all as specified and directed by Engr-in-charge.
Material and Labour for Reinforced concrete pipes of 200 mmdia, class NP3, laid and jointed complete with collars and jointed complete in cement mortar (1:1) complete all as specified and directed by Engr-in-charge.
Material and Labour for Reinforced concrete pipes of 300 mmdia, class NP3, laid and jointed complete with collars and jointed complete in cement mortar (1:1) complete all as specified and directed by Engr-in-charge.
Material and Labour for PCC (1:4:8) type D-2 (using 40mm graded mechanically crushed stone aggregate) as in foundation of manholes complete all as specified and directed
Material and Labour for RCC (1:2:4) type B-1 using 20mm graded mechanically crushed stone aggregate as in precast slabs for covers of manholes and set in CM 1:6 incl necessary from work hand placing of manhole cover on varsion complete all as specified and directed by Engineer-in-Charge. Note : Contractor to meniton month and year of casting to be engraved on each MH covers. No extra cost to be paid for this the same will be inlcuded in the above item.
Material and Labour for TMT bars 8mm dia and over cut to length bent to shape required incl cranking bending, spirally , hooking ends and binding with mild steel wire not less than 0.9mm dia (annealed) complete all as specified and directed by Engr-in-charge. (Note : The payment shall be made only after placing of cover on manholes)
Returning and filling incl spreading, levelling, water and well ramming in layers not exceeding 25cm thick complete all as specified and directed by Engr-in-charge
Demolition of reinforced cement concrete of any description and in any position complete all as specified and directed by Engr-in-charge.
Supply only integral water proofing compound
Removal of excavated material n. exc 50 M and depositing where directed at a level not exc 1.5 M above the starting point complete all as specified and directed by Engr-in-charge.
Material and Labour for Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and formingbranch channel (1/2 round or 3/4section) in cement concrete 1:2:4 mix type B-1smooth finished and reforming benching as required of 150mm dia of pipe complete all as specified and directed by Engr-in-charge.
Material and Labour for Cast iron Nahani trap 100 mm dia with long arm n less than 450mm grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed by Engr-in-charge.
Material and Labour CI 'P' or 'S' trap suitable for 100mm bore pipe, including jointing with run lead at one end, fixed as in repairs complete all as specified and directed by Engr-in-charge.
Material and Labour for Cast iron soil, waste and vent pipe, 100mm bore, sand cast in any length, with or without ears, with cement joints, fixed to walls with and including stack clamps, nuts , bolts etc. and making necessary connections complete all as specified after taking down of existing unserviceable pipe fixed in repair as directed by engn-in-charge.
Material and Labour for Cast iron soil, waste and vent pipe, 75mm bore, sand cast in any length, with or without ears, with lead joints, fixed to walls with and including stack clamps, nuts , bolts etc. and making necessary connections, fixed as in repair complete all as specified and directed by Engr-in-charge.
S&F holder battern clamp 100 mm dia of 50mm by 5mm flat iron and 16mm dia round iron stays. Including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed by Engr-in-charge.
S&F CI Bends (any radius), for 100mm bore CI piipes diminishing pieces or tapers (larger bore measured) fitted with oval access doors complete all as specified and directed by Engr-in-charge.
S&F single Y-shaped CI junction pieces, ordinary or inverted (spigot or socket type) for 100mm bore pipes complete all as specified and directed by Engr-in-charge.
S&F cast iron junction combination 'T' equal or unequal for 100mm bore with access door as in repair complete all as specified and directed by Engr-in-charge.
M&L for cast iron cowls of 100 mm dia complete all as specified and directed by Engr-in-charge.
S&F CI gully traps, Centrifugal type 150 x 150mm size , square or roundmouthed, type 'P' or 'S' fixed in repair complete all as specified and directed by Engr-in-charge.
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes with TMT bar handles to be welded to plates as in Nahani trap cover, if reqd including frame work of angle, complete all as specified and directed by Engr-In-Charge complete. Note : TMT bars will be measured and paid separately.
M&L for preparation of surfaces of steel surfaces of any description, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed by Engr-in-charge.
Material and labour for PCC100mm thick (1:2:4) type B-1, (using 20 mm graded stone agg) as in road cuttings complete all as specified and directed by Engr-In-Charge.
HG construction
DELTA CONSTRUCTION CO
M/s Rakesh Singla
FAVOURITE ENGINEERS
M/s Harmans
AR CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .