| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.3 LAccepted-AOC SHIV NIWAS DHANDA P O TOTU DISTT SHIMLA HP 171011 | SHIMLA | SHIMLA | HIMACHAL PRADESH | 171011 | 1 | Accepted-AOC LOWEST BIDDER | |
| 2 | 2₹10.0 L+₹24,235 (2.48%)Rejected-Finance CIVIL LINE MATATILA ROAD TALBEHAT DISTT LALITPUR U P | TALBEHAT | LALITPUR | U P | 2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | 3₹10.0 L+₹24,690 (2.53%)Rejected-Finance | 3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | 4₹10.1 L+₹28,535 (2.92%)Rejected-Finance VILLAGE TAPARIYAN BABINA CANTT BABINA JHANSI UP 284401 | BABINA | JHANSI | UP | 284401 | 4 | Rejected-Finance NOT LOWEST BIDDER | |
| 5 | 5₹10.1 L+₹37,420 (3.83%)Rejected-Finance VILL PO BUNGWAN KALAN TALBEHAT LALITPUR UTTAR PRADESH 284136 | TALBEHAT | LALITPUR | UTTAR PRADESH | 284136 | 5 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
9 Jul 2024, 6:00 pmClosed
BRIJ BIHARI
LAKEVIEW CAMP MIL STN TALBEHAT 284125
REPAIR/REPLACEMENT OF U/S LT/UG CABLE AND CONNECTED WORKS FOR AREA I AND II AT MIL STN TALBEHAT
2024_MES_660468_1
AGE (I) TBT/TOK-16/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
TALBEHAT MIL STN
8 documents required · 8 mandatory
₹500
Yes
AGE I TALBEHAT
₹20,000
21 Sept 2024
18 Jun 2024
11 Jul 2024
25 Jun 2024
9 Jul 2024
2 Jul 2024
Amount
Prunning of tree branches not less than 1.5 mtr around the LT/HT Over head line which obstructing the maintainance of electric supply as well as illumination in area including repair of damage broken ACSR conductor GI wire and jumpers, testing of line complete all as specified and directed by Engr-in-charge. (Note-Each span minimum 30 mtr)
Excavation in in trenches not exceeding 1.5 mtrs wide & not exceeding 1.5 mtr in depth in soft or loose soil & getting out complete all as spfd & directed.
Removing excavated materialn not exceeding 50mtr &deposited where direceted at a level not exceeding 1.5mtrabove the ground level.
Returning , filling in spreading, levelling, watering & well Ramming in layers not exc 25cm thick complete all as spfd & directed.
Supply & Laying un reinforced precast concrete cable cover, Class HVP type-2 flat size 250 mm x 150 mm x 40 mm for cable protection laid length wise perpendicular to the adzes of cable complete all as specified and directed.
Supply and laying m-sand for cushioning to underground cable in layers of 23 cm (8 cm deep before laying of cable and 15cm deep over the cable) after laying the cable in trenches including punning thickness up to 18 cm , complete all as specified and directed.
M&L in replacement of cable XLPE insulated heavy duty electric cables with Stranded alluminium conductor, 1100 volts grade, passing through trenches/ducts/pipes and climbing on poles/walls including fixing with proper size of alluminium lugs. For the following sizes. NOTE:- 1. Excavation and earth work to be measured and paid separately.
10 Sq mm 2 Core.
10 Sq mm 4 Core.
150 Sq mm 3.5 Core.
Fixing only for LT UG XLPE cable (in replacement of ACSR conductor) insulated heavy duty electric cables with Stranded alluminium conductor, 1100 volts grade, passing through trenches/ducts/pipes and climbing on poles/walls including fixing with proper size of alluminium lugs for the following sizes. NOTE:- 1. UG cable issued under Sch 'B' from MES store for free of fixing only 2. Excavation and earth work to be measured and paid separately.
25 Sq mm 4 Core.
50 Sq mm 3.5 Core.
95 Sq mm 3.5 Core.
120 Sq mm 3.5 Core.
Supply and laying or fixing in replacement GI tubes light grade 40 mm dia, on place of rusted GI pipe in support of cables, on pole/wall/laid in floor/in trenches incl cutting of road, PCC etc.
Repair/Maintenance/Servicing of gang operated device 11 KV fix on four pole/Two pole by replacement of fix and moving contact, flexible copper jumper etc as required for make serviceable for proper on/off operation complete all as specified and directed by Engineer-in-Charge.
Supply and laying or fixing in replacement GI tubes light grade 80 mm dia, on place of rusted GI pipe in support of cables, on pole/wall/laid in floor/in trenches incl cutting of road, PCC etc.
M&L for checking of APFC panel of any size and any capacity with minimum requirement of material like relay, contactor, CT etc all as per site requirement complete all as directed. (Note : Quoted rates shall be deemed to include opening of panel accessories and taking the defective items to the approved workshop for relay adjustment with reference to variable capactior acoording to load requirement, entire APFC panel should be capable of improvement of PF upto 0.995 on the average of monthly consumption, at the different loads of Pump set and during the off load entire installation even at No Load.
S & F for replacement of complete unit of capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase 440 V & 50 Hz System for permissible non- linear load 15% of 1 KVAR capacity suitable for existing capacitor bank at site complete all as specified and as directed.
S & F for replacement of complete unit of capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase 440 V & 50 Hz System for permissible non- linear load 15% of 2 KVAR capacity suitable for existing capacitor bank at site complete all as specified and as directed.
S & F for replacement of complete unit of capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase 440 V & 50 Hz System for permissible non- linear load 15% of 3 KVAR capacity suitable for existing capacitor bank at sitecomplete all as specified and as directed.
S & F for replacement of complete unit of capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase 440 V & 50 Hz System for permissible non- linear load 15% of 5 KVAR capacity suitable for existing capacitor bank at site complete all as specified and as directed.
All as per item No. 16 above but of capacity 10 KVAR suitable for existing capacitor bank at site complete all as specified and as directed.
All as per item No. 16 above but of capacity 12.5 KVAR suitable for existing capacitor bank at site complete all as specified and as directed.
All as per item No. 16 above but of capacity 15 KVAR suitable for existing capacitor bank at site complete all as specified and as directed.
M&L for thyristor switching module PS 12.5 KVAR for thyristor panel suitable for existing panel complete all as specified and directd.
M&L for thyristor switching module PS 25 KVAR for thyristor panel suitable for existing panel complete all as specified and directed.
M&L for thyristor switching module PS 50 KVAR for thyristor panel suitable for existing panel complete all as specified and directed.
M&L for capacitor heavy duty MLL/square 12.5 KVAR suitable for existing capacitor bank at site complete all as specified and directed and directed.
M&L for capacitor heavy duty MLL/square 25 KVAR suitable for existing capacitor bank at site complete all as specified and directed and directed.
M&L for contactor of suitable capacity with add on accessories suitable for capacitor bank of existing APFC panel including thimbles connection complete all as specified and as directed.
M&L for current transformer of suitable capacity for APFC panel along with 2.5 Sqmm PVC insulated FRLS, unsheathed, copper conductor stranded 1100 volt grade cable as per site requirement complete all as specified and as directed.
Note :- Debris obtained from all items should be removed in low lying areas as directed by Engr-in-charge out of MOD Land. (Rates quoted for items are deemed to be included for this, where removal of debris in the items is not considered.)
HARNAM SINGH ANIL SINGH (BID ID -3054577)
M/s Indu Enterprises (BID ID -3054548)
M/S Kharya Associates (BID ID -3054473)
M/S A.R BUILDERS (BID ID -3052514)
m/s bobby enterprises (BID ID -3053686)
M/S SHIVA TRADERS (BID ID -3054624)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .