| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.8 LAccepted-AOC 7 2 S F ARIHANT ARCADE CENTRAL MARKET SHASTRI NAGAR MEERUT U P 250004 | MEERUT | MEERUT | UTTAR PRADESH | 250004 | L1 | Accepted-AOC L1 and reasonable | |
| 2 | L2₹22.0 L+₹3.5 L (19.2%)Rejected-Finance 289 KASERU KHERA MAWANA ROAD MEERUT 250001 U P | MEERUT | UTTAR PRADESH | 250001 | L2 | Rejected-Finance In order but L2 | |
| 3 | L3₹22.3 L+₹3.9 L (21.0%)Rejected-Finance 150 BC LINE MALL ROAD MEERUT CANTT 250001 | MEERUT | UTTAR PRADESH | 250001 | L3 | Rejected-Finance In order but L3 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
23 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(U)E/M Meerut
Roorkee road Meerut
REPAIR/MAINTENANCE OF ELECTRIC INSTALLATIONS UNDER AGE E/M (ELECTRIC SUPPLY) AT GE(U) E/M MEERUT CANTT
2021_MES_492211_3
8388/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
Meerut
Please refer Tender documents.
12 documents required · 12 mandatory
₹500
GE(U)E/M Meerut
₹50,000
Yes
30 Apr 2022
2 Mar 2022
25 Mar 2022
2 Mar 2022
23 Mar 2022
9 Mar 2022
90 days
Amount
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundations, laying of pipe and cables etc or for shafts, well cess pits, manholes,pier holes not exceeding 10 sqm on plan ,.including dressing/trimming sides and levelling/grading & ramming bottom of excavation and getting out in soft/loose soil complete all as specified.
Returning ,filling in , including spreading , levelling , watering and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified.
Removing excavated material ( soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Material and labour river sand for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed . ( Note: Punned thickness shall be measured for the purpose of payment)
M&L laying fly ash old size bricks , straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.
Taking down old existing LT cable of any size and finding out fault in cable and reparing the cable by providing cable Joints and making the cable line functional and relaying in the cable in its original locations by providing retrived bricks and sand including necessary earthwork complete all as specified and directed. Note:- Cable joints required shall be paid seoarately unde relevant item as supplied only.
Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene ( XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of 16 sqmm 4 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene ( XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of 10 sqmm 4 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene ( XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of 10 sqmm 2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
Taking down existing unserviceable pipe and M&L 80mm nominal bore mild steel galvanised water tubing, light grade with all fittings like bends, elbows, Tee, reducers, sockets, unions etc laid in trenches/ fixed to walls / poles / laid in floors for protection of GI earth strip/ under ground cable complete all as specfied and directed. Note: Excavation, RF&R, removal of surplus soil and mild steel clamps with nuts and bolts shall be measured separately)
M&L for auguring of hole suitable for passing 80mm bore pipe in true horizontal position under road, PCC paths etc., by means of mechanical ring/ auger after doing ultrasound to prevent any damage to existing cables pipe line specified and directed coming in the route not exceeding 1.5 m in depth below existing surface level of road and not excd 30M in length complete all as specified. Note: Pipe shall be measured and paid separately under appropriate items and any damage to existing cables of anytype shall be made good by the Bidder without any extra cost to department.
Supply and fixing in reair aluminium thimble size 25 Sqmm to 50 Sqmm complete all as specified and directed.
Supply and fixing in reair aluminium thimble size 70 Sqmm to 120 Sqmm complete all as specified and directed.
Supply and fixing in reair aluminium thimble size 150 Sqmm to 185 Sqmm complete all as specified and directed.
Supply and fixing in reair aluminium thimble size 240 Sqmm to 400 Sqmm complete all as specified and directed.
Cutting of wornout / burnt aluminium cable terminal lugs from the HT/LT cable , crimping of new aluminium cable core and fixing with transformer, Panel MCCB terminal stud including cutting/ dressing of cable,disconnecting under ground cable from over head conductor , cutting down wornout portion under ground cables of any type and size for repairs including taking out under ground cable loop from ground and making connections of restoration of electric supply complete all as specified. Note:- Excavation, earth work , taking out cable protection covers, and sand cushion and relaying the same shall be deemed included in the unit rate quoted by Contractor)
M&L Earthing complete with galvanised mild steel earth plate electrode 600x600x6mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32x6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'medium grade' as water pipe from earth chamber to upper edge of earth plate, GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 40mm thick precast RCC 1:2:4 type B-1, duly reinforced with 8mm dia TMT bars @ 150mm C/c and 6mm dia bars in lifting handles amd MS angle frame of angle iron 40x40x5 mm thick, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate number 3 of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Finding out fault in any size of cable, 1100V grade to 33000V with the help of Fault Testing Van by disconnecting of cable from both sides and making connection after fault finding and repairs upto a length of 500m complete all as specified. Note:- All the equipments, tackle, T&P, Fault finding/ testing Van etc shall be arranged by contractor at hos own cost. The rate quoted by contractor shall deem to be included and nothing extra shall be allowed.
M&L for preparation of old painted surfaces erected steel tubular swaged poles / Rails/Girder poles of LT over head line ( Except embedded portion) , 9 M long including all MS work mounted on pole , earth protection & water pipe ( if exists) and providing one coat of aluminium paint and providing 05 Nos bands/ straps with Two coats of synthetic enamel paint ( black & yellow and Black and red white 30 cm wide each) from top of plinth block and numbering of poles with white synthetic enamel paint on yellow synthetic enamel piant ground (50mm wide and 100mm high letters) including encircling the letters or figures complete all as specified
M&L for preparation of old painted surfaces erected steel tubular swaged poles / Rails/Girder poles of LT over head line ( Except embedded portion) , 11 M long including all MS work mounted on pole , earth protection & water pipe ( if exists) and providing one coat of aluminium paint and providing 05 Nos bands/ straps with Two coats of synthetic enamel paint ( black & yellow and Black and red white 30 cm wide each) from top of plinth block and numbering of poles with white synthetic enamel paint on yellow synthetic enamel piant ground (50mm wide and 100mm high letters) including encircling the letters or figures complete all as specified
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit for unserviceable materials (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc to match with the existing complete all as specified.
M&L point wiring for one light point /tube point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed cables in and including 25 mm dia or higher size PVC concealed conduits and PVC fittings, including Zinc Coated pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and including continuous earth wire of 1.5 sqmm nominal cross sectional area multistranded copper conductor , PVC insulated unsheathed and connecting to earth dolly and brass screws, washers etc. complete all as specified :- Note:- The rate quoted against this item shall be deemed included for cutting chases for concealed conduit and boxes etc including making good disturbed surfaces to match with the existing.)
M&L point wiring for one fan point controlled by one, one way switch and regulator using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed cables in and including 25 mm dia or higher size PVC concealed conduits and PVC fittings, including Zinc Coated pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and including continuous earth wire of 1.5 sqmm nominal cross sectional area multistranded copper conductor , PVC insulated unsheathed and connecting to earth dolly and brass screws, washers etc. complete all as specified :- Note:- The rate quoted against this item shall be deemed included for cutting chases for concealed conduit and boxes etc including making good disturbed surfaces to match with the existing.)
M&L point wiring for one bell point controlled by one, one way switch and regulator using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed cables in and including 25 mm dia or higher size PVC concealed conduits and PVC fittings, including Zinc Coated pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and including continuous earth wire of 1.5 sqmm nominal cross sectional area multistranded copper conductor , PVC insulated unsheathed and connecting to earth dolly and brass screws, washers etc. complete all as specified :- Note:- The rate quoted against this item shall be deemed included for cutting chases for concealed conduit and boxes etc including making good disturbed surfaces to match with the existing.)
M&L point wiring for one socket outlet point on independent Board controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed cables in and including 25 mm dia or higher size PVC concealed conduits and PVC fittings, including Zinc Coated pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and including continuous earth wire of 1.5 sqmm nominal cross sectional area multistranded copper conductor , PVC insulated unsheathed and connecting to earth dolly and brass screws, washers etc. complete all as specified :- Note:- The rate quoted against this item shall be deemed included for cutting chases for concealed conduit and boxes etc including making good disturbed surfaces to match with the existing.)
M&L point wiring for one socket outlet point on same Board with otherswitches controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed cables in and including 20 mm dia or higher size PVC concealed conduits and PVC fittings, including Zinc Coated pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and including continuous earth wire of 1.5 sqmm nominal cross sectional area multistranded copper conductor , PVC insulated unsheathed and connecting to earth dolly and brass screws, washers etc. complete all as specified :- Note:- The rate quoted against this item shall be deemed included for cutting chases for concealed conduit and boxes etc including making good disturbed surfaces to match with the existing.)
M&L point wiring for one socket outlet point on independent Board controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed cables in and including 20 mm dia or higher size PVC concealed conduits and PVC fittings, including Zinc Coated pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and including continuous earth wire of 2.5 sqmm nominal cross sectional area multistranded copper conductor , PVC insulated unsheathed and connecting to earth dolly and brass screws, washers etc. complete all as specified :- Note:- The rate quoted against this item shall be deemed included for cutting chases for concealed conduit and boxes etc including making good disturbed surfaces to match with the existing.)
Supply & fixing polycarbonate Switch piano flush type,SP, 05/06 Amps, one way ( ISI), 230 volt marked specified make complete all as specified.
S&F polycarbonate bell push flush type,SP, 05/06 Amps, one way ( ISI) marked, 230 volt complete all as specified.
S&F Buzzer, Ding dong, AC 230 Volts, single pole complete all as specified and directed.
Supply & fixing polycarbonate Switch piano flush type,SP, 15/16 Amps , one way ( ISI), 230 volt marked specified make complete all as specified.
S&F Polycarbonate socket out let 2 in 1, 5 pin , 6 Amps flush type controlled by one switch ( ISI) marked complete all as specified.
S&F Socket outlet 2 in 1 ,6 pin, 15/16 amp, flush type, 230 volt ( ISI) marked complete all as specified.
S& F ceiling fan regulator electronic modular socket type , rotary 0 to 4 steps , hum free, 100 watts , 230 Volts, ISI marked complete all as specified .
S&F Lamp holder, polycarbonate type with back plate complete all as specified and directed.
S&F polycarbonate insulated body ceiling rose 6A, 65x50mm dia with three terminals, ISI maked fixed complete all as specified.
S&F in repair 20watts Light emitting Diode (LED) tube light fitting wall mounting , indoor decorative alumiinium extruded T5 LED battens , Integrated type, AC 230-240V, 50 hz, with PMMA/PC diffuser, 4' long, and making connections with and including 23/.0076 flexible cord of required length from ceiling rose to connector complete all as specified and directed.
Supply and fixing post top lantern LED type 40 watt 230 volts AC outdoor type with decorative post top for 360 degree indirtect light IP 65 protection with impact and corrosiion resistant made in cast aluminium with decorative opal poly carbonate diffusercomplete with driver and lamp complete all as specified and directed.
S&F in repair Energy saving & environment friendly LED street light made out of pressure die cast anodised aluminium housing with polycarbonate or flat glass optical cover, system power euqal to or not less than 25 watt to achieve B1 class road illumination as per IS: 1944 and as per national lighting code each LED >1 watt and <3 watt , Luminous of efficiency of LED >= 135 Lumens/Watt, ,CRI >70, CCT > 5000K to 6500 K with LED life span at 70% of light output >50000 hours (L70) with suitable driver 140V to 270V universal type, with bult in surge protection >5KV, 50 Hz +/- 3% , pf 0.95, THD <10% with system efficiency >85 lumens/ Watt and power efficiency >=90% and overall IP 65 or better , , driver and luminaire shall comply LM-79/IS:16106 including 32mm nominal bore light grade GI pipe brackets made out of 1.5m long GI pipe, bent to shape, and fixed to poles/ walls with 2 Nos MS mild steel FI brackets of 40x6mm, comprising 4 Nos MS hexagonal head bolts of 12mm dia, 75mm long with washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and making connections with cable complete all as specified and directed. and making connections complete all as specified and directed by EIC.
M&L for submain wiring comprising two single core ,4 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including PVC concealed conduit and conduit fittings , medium grade not less 25mm dia with 2.5 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified. ( Note :- (a) Extra length of cables/ wire required for connection to MCB shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) (b) One metre of conduit alongwith 2x4 sqmm wire and 1x2.5 sqmm earth wite shall be measured as one unit length)
M&L for submain wiring comprising two single core ,6 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including PVC concealed conduit and conduit fittings , medium grade not less 25mm dia with 4 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified. ( Note :- (a) Extra length of cables/ wire required for connection to MCB shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) (b) One metre of conduit alongwith 2x6 sqmm wire and 1x4 sqmm earth wite shall be measured as one unit length)
Taking down of existing unserviceable MCB and S & F Miniature circuit breakers SP, 6 to 32 Amps, 240 Volts , 10 KA, 'C' curve rating and to be housed in exixting sheet metal enclosures ( distribution boxes) complete all as specified and directed :- (Note :- Proper and suitable size cable lugs to be fixed with Miniature circuit breakers are included in unit rate of each Miniature circuit breakers of any rating).
S&F in repair Miniature circuit breakers SP,40 Amps, 240 Volts , 10 KA, 'C' curve rating and making connections with suitable copper lugs complete all as specified and directed :- (Note :- Proper and suitable size cable lugs to be fixed with Miniature circuit breakers are included in unit rate of each Miniature circuit breakers of any rating).
S&F in repair Miniature circuit breakers SP,63 Amps, 240 Volts , 10 KA, 'C' curve rating and making connections with suitable copper lugs complete all as specified and directed :- (Note :- Proper and suitable size cable lugs to be fixed with Miniature circuit breakers are included in unit rate of each Miniature circuit breakers of any rating).
S & F epoxy powder coated distribution box, Single pole & neutral 8 way with 200 amps rated bus bar, 240 Volts, double door for MCB , grouted flush to walls including making good disturbed surafces to match with the existing complete all as specified and directed.
S & F epoxy powder coated distribution box, Single pole & neutral 4 way with 200 amps rated bus bar, 240 Volts, double door for MCB , grouted flush to walls including making good disturbed surafces to match with the existing complete all as specified and directed.
Taking down of old existing unserviceable danger notice board and S&F Danger notice plate 1.6 mm thick mild steel sheet, vitreous enamelled white , with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps , bolts and nuts of approved size, for HT , 25x20 cm size complete all as specified. Note:- FI clamps, nuts, bolts and washers etc. shall be deemed included in the unit rates quoted by contractor.
M&L for 1.6mm thick mild steel plate as in feeder name plate, vitreous enamelled white, with letters in hindi , figures in english and conventional sign in signal red colour and fixed with and including MS clamps, bolts and nuts of approved size for 30x25 cm size complete all as specified
M&L for providing and installation of sign Board of size 1280mmx900mm complete all as specified, shown in drawing marked as Sketch 'A' and directed by Engineerin-Charge.
M&L for providing and installation of LED glow sign Board of size 2750mmx900mm complete all as specified,shown in drawing marked as Sketch 'B' and as directed by Engineerin-Charge.
S& F Synthetic insulating mat of size 2mx1mx10mm for 11 KV supply complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing ), removing serviceable tiles to store and rubbish off the premises complete all as specified.
Demolition Stone slabs and tiles of any description or thickness in floors, aprons etc.laid dry or laid dry and pointed complete all as specified.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified.
Demolition of cement concrete ( unreinforced ) in ground floors and pavings not exceeding 15 cm thick above or below ground level complete all as specified and directed.
Taking down cement plaster on brick or stone walls , concrete block walls etc. including racking out joints, hacking for key, scrubbing down with water, any description etc. and removing of the rubbish complete all as specified .
Demolition Brickwork or stone boulder masonry/PCC block masonry , built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified.
M&L Brick work with old size fly ash bricks., straight or curved on plan exc 6 m mean radius , built in CM 1:6, complete all as specified and directed.
M&L Brickwork with old size bricks ( Except bricks) , straight or curved on plan excd 6 M nmean radius in built in cement and sand mortar 1:6 complete all as specified.
M&L rendering 15 mm thick on fair faces of brick work or concrete surfaces , in cement and sand mortar 1:4 , top surfaces finished fair and even complete all as specified
M&L rendering 15 mm thick on RCC roof projections/chajja surfaces , in cement and sand mortar 1:4 opver and including Dubbing coat ( average 10 mm thick on irregular face of RCC ) in cement mortar 1:6 complete all as specified.
M&L 100mm thick plain cement concrete type B2 (1:2:4), using 40 mm graded crushed stone aggregate,as in floor /hard standing/paving laid in alternate panels, top finished even and smooth without using extra cement complete all as specified.
M&L 100mm thick plain cement concrete type D2 (1:4:8), using 40 mm graded crushed stone aggregate,as in sub floor finished even and fair to receive floortopping complete all as specified.
Supply only Liquid water proofing compound
M&L Plain cement concrete type C2 (1:3:6), using 40 mm graded crushed stone aggregate,75 mm thick , as as in path / plinth protection/paving finished even and smooth with out using extra cement complete all as specified. ( Glass/PVC dividing strips shall be measured separately).
M&L Chequered cement concrete tiles 30cmx30cmx25 mm thick with grey cement and pigment , set, jointed and pointed in neat cement slurry over and including 15mm thick screeding in CM 1:6 in floors complete all as specified.
M&L 20-25mm thick machine cut Kota stone slab of size 550mmx550mm in flooring laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to give high gloss (mirror) finish over and including 15mm thickscreed bed in CM 1:6 complete all as specified.
M&L joint free Non Skid ceramic designer coloured tiles ( square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screeding in CM 1:6 complete all as specified.
M&L machine pressed precast cement concrete interlocking paver block any shape and size conforming to IS-15658-2006 of 60mm thickness, M-35 Grade , using grey cement and pigment, laid dry on sand not less than 30 mm thick, interstices filled in floors/ pathway complete all as specified.( Rate quoted shall deem to be included for filling outer edges with PCC 1:2:4 type B1)). ( Note:- Sand cushion shall be deemed included in the unit rate quoted by Contractor and shall not be measured separately)
M&L designer digital glazed ceramic coloured tiles (Group B II) of size excd 0.11 sqm and not excd 0.18 sqm , 7-8mm thick , on vertical surfaces such as dados , skirting and risers to steps etc. set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick screeding in CM 1:4 complete all as specified.
M&L for Ornamentaland intricate design framed work such as grills , gratings, etc., with ends of bars shouldered and/ or riveted, or forged in to spikes; framed guard bars ; barred iron doors; ladders; framed balusters ; walk ways ; railings; frame work of water tanks and similar work conforming to Fe-290-Gde E-165
M&L for precast cement concrete 1:2:4 type B1 using 20mm gaded stone aggregate as in landings, cover slabs( for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set and jointed in cement mortar 1:4 complete all as specified.
M&Lfor Providing precast cement concrete louvers and jallies ,type B0 using 12.5 mm graded stone aggegate , 25 mm thick ( measured solid), including all mouldings frame set and jointed in Cement Mortar !:4 complete all as specified and directed.
Dismantling posts or struts ( wood , steel or R.C.C.) any section, posts embedded in natural ground including taking out embedded portion and making good disturbed ground complete all as specified.
M&L Rolled mild steel in rolled sections as in main and cross beams, hip and jack rafters ; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe-410 W grade A complete all as specified.
Plain cement concrete 1:3:6 mix with crushed stone aggregate 40 mm nominal size as in foundation , fillimg in mass concrete complete all as specified.
S&F in repair Mild steel Galvanised, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacings and straining and fixing to any type of standard rails straining bolts , including,securing or tying at crossings with and provision of galvanised mild steel wire , staples or steel pins etc. as directed ( each line wire to be measured) complete all as specified.
M&L for Rolled mild steel in rolled sections (Fe-410-W ( Gde-E-250) quality -A ) as in framing for cladding , glazing and the like fixed with angle cleats and connecting plates, etc.complete all as specified.
M&L for Round Mild steel bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire ( annealed) not less than 0.90 mm dia. Or securing with clips complete all as specified.
S&F Mild steel bolts, purpose made, with hexagonal or square head one end and screwed the other , or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut, exc 30cm long dia of neck exc 12 but not exc 20mm complete all as specified.
Supply only Chain Link MS galvanised fencing of meshsize 50mm x 50mm and diaof wire 3mm complete all as specified and directed. (Note:- Weight of Chain link fencing shall be decided by a Board of Officers)
Fixing only chain link fencing including line wires, any mesh size and type to any type of standards , rails, straining bolts etc. including provision of binding wire complete all as specified.
All as item No 83 above but fixed in repair
M&L preparation of old decorated plastered surfaces of ceilings by brooming down and applying ttwo coats of white wash including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
M&L for preparation of old surfaces of walls by complete removal of existing treatment and applying acoat of Wall care white ( Putty) 2mm thick and applying distempering with distemper oil emulsion , two coats, white or tinted including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
M&L preparation of old plastered / unplastered decorated surfaces of walls by brooming down and applying one coat of distemper oil emulsion white wash including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
M&L preparation of new plastered / unplastered surfaces of walls and applying two coats with cement base paint , white or tinted including and washing floors, etc. , of drops and splashes complete all as specified .
M&L for complete removal of existing treatment from the walls and applying Two coats of cement base paint , white or tinted on old surfaces of walls including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
M&L for complete removal of existing treatment from the walls and applying one coat of cement base paint , white or tinted on old surfaces of walls including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces
M&L preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamelled paint over one coat of red oxide Zinc chrome primer complete all as specified.
M&L preparation of new steel surfaces of any description not otherwise described not exc 10 cm width or girth and applying two coats of synthetic enamel over one coat of red oxide Zinc chrome primer complete all as specified.
Surface dressing not exc 15 cm deep in soft/loose soil including cutting vegetation or grass and uprooting trees upto 300mmgirth, shrubs, bushes and removing rubbish to adistance of 500m complete all as specified.
Supply , laying and levelling stone aggregate 40mm t0 63 mm grade complete all as specified .
M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric ( wt. not less than 150 gms/sqm) laid on primed surface by forced application over and including a tack coat of Industrial bitumen 85/25 at the rate of 1.2 Kg per sq.m. including cleaning surfaces over andincluding 10mm thick rendering in cement mortar 1:4 mixed with water proofing compound as per manufacturers instruction including one coat of aluminium paint over membrane complete all as specified.
Shikha Enterprises
VIRAT CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .