EXECUTIVE ENGINEER (SDW)-I
EXECUTIVE ENGINEER (SDW)-I KILOKRI SPS JAL VIHAR LAJPAT NAGAR NEW DELHI - 110 024
Electrification work of Lodhi Road staff quarters under EE(SDW)-I division.
2021_DJB_201956_1
NIT- 12 (2020-21)/SDW-I
Open Tender
Electrical Works
Works
30 days
EXECUTIVE ENGINEER (SDW)-I
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
EMD A/c No. 50448339804 at Allahabad Bank,
Exempted
3 Apr 2021
20 Mar 2021
31 Mar 2021
20 Mar 2021
31 Mar 2021
20 Mar 2021
Rewiring work of 01 No. type-III staff quarters F-28 Lodhi Colony:- 1.8.1/2 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group A
1.14.2/3 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 1.14.2 /3- 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire.
1.14.3/3- 2 X 4 sq. mm + 1 X 4 sq. mm earth wire.
1.14.4/3- 2 X 6 sq. mm + 1 X 6 sq. mm earth wire.
1.29/7 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.
1.30/7 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
1.25/6 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.33/7 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
1.34/7 Supplying and fixing brass batten/ angle holder including connection etc. as required.
1.38/8 Supplying and fixing call bell/ buzzer suitable for single phase, 230V, complete as required.
1.41/8 Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
1.44/8 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required
1.50/9 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
1.51/9 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
2.3/11 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way double door
2.10.1/12 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. In Single pole.
2.12.2/12 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amp.
Dismantling the old Al wiring of wooden capping and making good the damage with cement mortar i/c minor reqd. items complete in all respect.
Mehar Enterprises
SHREE KRISHANA ENGINEERING
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .