| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.9 LAccepted-AOC 24A RABINDRA SARANI KOLKATA 700 073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | L1 | Accepted-AOC AOC_Issued | |
| 2 | L2₹31.1 L+₹4.1 L (15.3%)Rejected-Finance | L2 | Rejected-Finance that the bis is not L1 | |
| 3 | L3₹34.1 L+₹7.2 L (26.8%)Rejected-Finance 24C GOABAGAN LANE KOLKATA 700 006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L3 | Rejected-Finance that the bis is not L1 |
| Sl No | Description | Qty | Unit | BANERJEE CONSTRUCTION AND CO L2 | ALPHA ELECTRICALS L3 | STANDARD BUILDERS L1 |
|---|---|---|---|---|---|---|
| 1.00 | PART A- Electrical Installation Work
Cost of labour charges for dismantling the existing distribution wiring ,Old panel, main switches,AC points , computer points , power plug points , single tube light fittings ,twin tube light fittings , HTPN DB , SPNDB , fan , cable and other accessories and mending good the damages as to G.S by Co's own tools and tackles & submit to section office. | 1 | Job | 15,000 ₹15,000 | 5,000 ₹5,000 | 1,000 ₹1,000 Lowest |
| 2.00 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Gloster/RR kabel/Havells) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish
Average run 9 mtr | 400 | Pt. | 700 ₹2,80,000 Lowest | 995 ₹3,98,000 | 800 ₹3,20,000 |
| 2.10 | a)On Board | 46 | Pt. | 765 ₹35,190 | 72 ₹3,312 Lowest | 100 ₹4,600 |
| 3.00 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works
200 mm x 150 mm x 65 mm | 30 | Each | 210 ₹6,300 | 292 ₹8,760 | 100 ₹3,000 Lowest |
| 4.00 | S&F of 2+12way SPN MCBDB comprising of 1no. 40A MCB DP Isolator as i/o & 10nos. 6/10A SPMCB as per G.S. with all necessary connections (Make: Legrand /Siemens/ ABB ) | 10 | Each | 4,200 ₹42,000 | 4,298 ₹42,980 | 4,000 ₹40,000 Lowest |
| 5.00 | Supplying and fixing 415V 6/10A, 6 way TPN MCBDB comprising with of 1no. 63A FP Isolator and 18 nos.,(6- 32)A SP MCB with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make:Legrand/SIEMENS/ABB make) | 3 | Each | 6,500 ₹19,500 Lowest | 8,335 ₹25,005 | 8,000 ₹24,000 |
| 6.00 | Supplying and fixing double door 6 way Vertical TPN MCB DB concealed in wall after cutting the wall & mending good the damages to original finish
INCOMING- Supplying and fixing 415 V, 160A Four Pole MCCB of Breaking capacity 25kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in DBs and necessary connection -1No.(Make:Legrand/ABB/ Siemens) OUTGOING- Supplying and fixing 240V 63A TP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs with all necessary connections.(Make: Legrand/ABB/ Siemens) | 3 | Each | 30,919 ₹92,757 | 29,875 ₹89,625 Lowest | 35,000 ₹1,05,000 |
| 7.00 | Supplying and fixing double door sheet steel
(16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment. 6 Way VTPN | 3 | Each | 2,650 ₹7,950 | 1,278 ₹3,834 Lowest | 1,500 ₹4,500 |
| 8.00 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By ISI-Medium GI pipe | 6 | Set. | 1,960 ₹11,760 | 1,650 ₹9,900 Lowest | 3,000 ₹18,000 |
| 9.00 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe | 4 | Item | 1,885 ₹7,540 | 1,090 ₹4,360 | 400 ₹1,600 Lowest |
Tender Value
₹31.1 L
EMD Value
₹62,300
Closing Date
29 Jul 2025, 1:00 pmClosed
EE,KNHED, PW Dte
THE EXECUTIVE ENGINEER, P.W.D /KOLKATA NORTH HEALTH ELECTRICAL DIVISION
Electrical Rewiring installation work i.c.w. Through Civil Repair Renovation work at OPD Building at Salt Lake Sub-Divisional Hospital, Salt Lake
2025_WBPWD_862493_1
WBPWD/EE/KNHED/e-NIQ-17/25-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
120 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹62,300
Office of The EE, KNHED, PW Dte
22 Apr 2026
11 Jun 2025
31 Jul 2025
11 Jun 2025
29 Jul 2025
19 Jun 2025
18 Jun 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.58 MB
2911.pdf
Tender Documents • 0.50 MB
BOQ_1936515.xls
BOQ • 0.33 MB
suspension.pdf
Additional Documents • 2.91 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .