| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC 331 TOWER A SPAZE I TECH PARK SECTOR 49 SOHNA ROAD GURGAON 122002 | GURGAON | GURGAON | HARYANA | 122002 | ₹1.3 Cr Quoted ₹1.4 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.5 Cr+₹16.3 L (11.9%)Rejected-Finance | ₹1.5 Cr+₹16.3 L (11.9%) | L2 | Rejected-Finance L2 |
| 3 | L3₹1.5 Cr+₹16.6 L (12.1%)Rejected-Finance | ₹1.5 Cr+₹16.6 L (12.1%) | L3 | Rejected-Finance L3 |
| 4 | L4₹1.6 Cr+₹21.2 L (15.5%)Rejected-Finance | ₹1.6 Cr+₹21.2 L (15.5%) | L4 | Rejected-Finance L4 |
| 5 | L5₹1.6 Cr+₹26.7 L (19.4%)Rejected-Finance 355 85 GALI NO 16 ASHOK VIHAR PHASE II BHIM GARH KHERI ASHOK VIHAR PHASE II GURGAON GURGAON HARYANA 122001 | GURUGRAM | HARYANA | 122001 | ₹1.6 Cr+₹26.7 L (19.4%) | L5 | Rejected-Finance L5 |
Tender Value
₹1.9 Cr
EMD Value
₹3.8 L
Closing Date
4 Apr 2024, 4:00 pmClosed
JITENDER KHURANA
Gurugram University Gurugram
Supply, Installation, Testing and Commissioning (SITC) of VRV Air-conditioning System for Administrative and Academic Block - I of Gurugram University, Gurugram.
2024_HRY_366106_1
20245DDF832C 9C4D 4A3E 9AEB 34CC282766051857GGU
Open Tender
Civil Works
Works
120 days
Gurugram
2 documents required · 2 mandatory
₹15,000
Yes
₹3.8 L
Yes
26 Sept 2024
9 Mar 2024
5 Apr 2024
9 Mar 2024
4 Apr 2024
9 Mar 2024
Amount
Supply, Installation, Testing and Commissioning of Modular Type outdoor units, equipped with Highly Efficient Scroll, all Inverter Compressor(s), special heat exchanger, Y- branch as required, outdoor unit support, auto check function for connection error, auto address setting,Refrigerant temperature control and capacity as mentioned below. VRV/VRF System shall be suitable for working on 50°C ambient temperature, Refrigerant R 410A.
VRV/VRF System shall be suitable for working on 50°C Ambient Temperature, with Refrigerant R-410A. Unit price shall be inclusive of full charge of Refrigerant Gas & Oil, Freight, Insurance as applicable In INR. The COP of systems mentioned below shall be Minimum 7.1 at 50% load, at AHRI conditions in cooling conditions.
The manufacturer of ODU and compressor shall be same. i.e the make of compressor shall be identical to the ODU.
The ODU shall have refrigerant cooled PCB Chamber for better operation at high ambient temperature
The system shall deliver at least 87% of mentioned nominal capacity at 43 Deg C ambient temperature.
The Fan static pressure of ODU shall be minimum 75 Pa to avoid hot air accumulation.
40 HP (20 HP + 20 HP ODU UNIT)
Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. Make- MITSUBISHI ELECTRIC / O GENERAL / DAIKIN/ Blue Star
2 TR or 2.5 HP (or above) 4 - way Cassette Unit Location: 12 Nos in Admin Block 20 Nos in Academic Block
3 TR or 4.0 HP (or aboe) 4 - way Cassette Unit
Supply & Fixing of Interconnecting copper refrigerant pipe work with thick duly insulated with Nitrile insulation between indoor and outdoor units as per specifications Approved Makes- Rajco/Mandev/Maxflow or as per directions of Engineer In-Charge
6.4 mm dia (1/4) 19mm Thickness with insulation 9 mtr lumpsum in Admin Block 21 mtr lumpsum in Academic Block
9.5 mm dia (3/8) (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
12.7 mm dia (1/2) (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation 28 mtr lumpsum in Admin Block 7 mtr lumpsum in Academic Block
15.86 mm dia (5/8) (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
19.1 mm dia (6/8) (OD) (hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
22.2 mm dia (OD) (7/8) (hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
25.4 mm dia (OD) (hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
28.58 mm dia (11/8) (OD) (hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
31.8 mm dia (OD) (hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
34.9 mm dia (13/8) (OD) (hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
41.3 mm dia (15/8) (OD) (hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
Supply & Installation of Refrigerant R-410A to top up the system as per directions of OEM.
Supply, installation, testing and commissionig of refrigerant Copper Y-joints Approved Makes- MITSUBISHI ELECTRIC / O GENERAL / DAIKIN/ Blue Star as per directions of Engineer In-Charge
Supply, Installation, Testing and Commissioning of Master Remote Control panel including all necessary control wiring. Master Remote Control Panel shall be connected to all indoor/outdoor units and shall be of one touch screen type. Make- MITSUBISHI ELECTRIC / O GENERAL / DAIKIN or as per directions of Engineer In-Charge
Suitable for indoor units.
CONTROL AND TRANSMISSION WIRING: Supply and Laying of 2 core x 1.5 sqmm PVC insulated copper conductor communication control cable in PVC Conduit. Approved Make : Havells/ Polycab/ RR Kabel/ Anchor/ KEI or as per directions of Engineer In-Charge
POWER CABLE: Supply and Laying of 3 core x 2.5 sqmm PVC insulated copper conductor cable for indoor units. Approved Make : Havells/ Polycab/ RR Kabel/ Anchor/ KEI or as per directions of Engineer In-Charge
Supply and Laying 4.0 core x 25 Sq.mm Alluminium conductor armoured cable. Approved Make : Havells/ Polycab/ RR Kabel/ Anchor/ KEI or as per directions of Engineer In-Charge
Supply, installation, testing & commissioning of cubical type main MV panel board suitable for 3 Phase, 50 Hz and of 35 MVA rupturing capacity at 415 volts, fabricated from minimum 2mm thick CRCA sheet powder coated through seven tank process facility for prickling and degreasing complete with following mountings, interconnections etc. as required. (GA drawing of panel to be provided before fabrication). Panel shall be Floor mounted type with cable entry at the top and IP-65 Degree of protection. Panel shall be powder coated having colour shade RAL-7032. including the following switch gear and components: MAKE : UPS/ RR CONTROL/ TRICOLITE/Havells/L&T/SIEMENS or as approved by Engineer-in-charge
INCOMER: 400A FP MCCB 36kA TMR + Spreader Links - 01 nos
OUTGOINGS: 125A FP MCCB 10KA (FOR VRF ODUs) - 7 Nos (as per site requirement)
10A TPN MCB 10KA(FOR VRF IDUs) - 82 Nos
Providing and fixing of MS Stand for Outdoor Units.
Bidder Name
Amount
WEATHER CONDITIONERS (GSTN-06AFXPA1351C2ZT) BID ID -1072474
UTILITY SERVICES (GSTN-07AABFU8051C2ZD) BID ID -1075812
AIR WAVES ENGINEERS PVT. LTD. (GSTN-07AADCA2162M1ZP) BID ID -1077054
Mark Engineering Inc.(GSTN-NA)--1078685
modern cooling solution(GSTN-NA)--1078677
SMD SOLUTIONS(GSTN-NA)--1076986
WEATHER CONDITIONERS
SMD SOLUTIONS
AIR WAVES ENGINEERS PVT. LTD.
Mark Engineering Inc.
modern cooling solution
WEATHER CONDITIONERS
SMD SOLUTIONS
AIR WAVES ENGINEERS PVT. LTD.
modern cooling solution
UTILITY SERVICES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .