| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC | ₹1.0 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹1.1 Cr+₹6.7 L (6.41%)Rejected-Finance | ₹1.1 Cr+₹6.7 L (6.41%) | L2 | Rejected-Finance OTHER THAN LOWEST |
| 3 | L3₹1.2 Cr+₹13.8 L (13.2%)Rejected-Finance 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹1.2 Cr+₹13.8 L (13.2%) | L3 | Rejected-Finance OTHER THAN LOWEST |
| 4 | L4₹1.5 Cr+₹41.2 L (39.3%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | ₹1.5 Cr+₹41.2 L (39.3%) | L4 | Rejected-Finance OTHER THAN LOWEST |
| 5 | L5₹1.5 Cr+₹42.8 L (40.9%)Rejected-Finance WZ 143 A 7A S 4 43 GALI NO 2 OLD MAHAVIR NAGAR NEW DELHI 110018 | WEST DELHI | DELHI | 110018 | ₹1.5 Cr+₹42.8 L (40.9%) | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹1.2 Cr
EMD Value
₹2.0 L
Closing Date
25 Feb 2023, 6:00 pmClosed
CWE NEW DELHI, DELHI CANTT
HQ CWE NEW DELHI, RAO TULA RAM MARG, DELHI CANTT 10
SPL REPAIR FOR COMPREHENSIVE REPAIRS, WATER PROOFING TREATMENT AND OTHER ALLIED WORKS IN VARIOUS BLDGS AT NDC UNDER GE NEW DELHI, DELHI CANTT-10
2023_MES_573040_1
CWE/ND-39/2022-23
Open Tender
Miscellaneous Works
Item Rate
272 days
NEW DELHI
PLEASE REFER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
GE NEW DELHI
₹2.0 L
Yes
13 Apr 2023
4 Jan 2023
27 Feb 2023
4 Jan 2023
25 Feb 2023
11 Feb 2023
Amount
M&L for Treatment of roof with reinforced elastomeric liquid waterproofing membrane of 400 micron thickness having SRI of 130, tested as per ASTM E 1980. The coating should have water absorption less than 1% as per IS: 101 (P-7/Sec-1) 1989, with the ability to resist temperature upto 120 °C as per IS: 101 (P-7/Sec-3) 1990 having VOC less than as per ASTM D 3960 and should have excellent resistance to transmission of ponded water upto 3.5 bars of pressure for 7 days. The waterproofing membrane will be laminated with 25—40-micron thick transparent Nano modified composite crosslinking polymeric coating with a minimum of 40% solid content as per IS: 101 (P-8/Sec-6) 1993 and also should pass Impact test as per IS: 101 (P5/Sec-3) 1988 along with having dust and water repellent and anti graffiti property passing scratch hardness test of 500g as per IS 101(P5/SEC2). The Polymeric coating should have a self-cleaning and easy-to-clean property with excellent weather stability and DPR (Dirt pickup ratio), including preparation by pressure wash cleaning to remove all dust, fungus, etc., with pressure washer after repairing the existing roof having old bitumen membrane by filling cracks, potholes, holes with waterproofing compound having compressive test as per IS-4031 part 6-1988 and permeability of water as per IS; 2645-2003 complete all as specified and directed.
Notes :- (i) Entire work shall be carried out through manufacturer or his authorised representative. (ii) The contractor shall furnish a 10 years guarantee for effectiveness of waterproofing treatment and the period shall be reckoned from the next day of actual date of completion of work. (iii) An amount of 2.5 % of total quoted amount against these items shall be retained, out of the final bill amount as security deposit, against guarantee of 10 years for water proofing effectiveness and the same shall be released only after the expiry of guarantee period. The contractor may also furnish fixed deposit receipt/ BGB in lieu of the security deposit to be retained as security.
Removing and refixing of double AC ducts and cable tray including welding work as directed by engineer in charge.
Taking down cement plaster on brick wall surfaces including racking out joints hacking for key scrubbing down with water etc. and removing the rubbish out to MOD land complete all as specified and directed.
M&L for Expended metal, cut to length, bent to shape required and tying and securing/anchoring with wall, weight of mesh not exc 4 Kg/Sqm complete all as specified and directed.
M&L for Grout injecting with cement mortar 1:1 (one part of cement and one part of sand) @ 15cm c/c interval both way on brick surfaces of wall/RCC facia/Ceiling by pressure using mechanically pressure epoxy injector with accessories till the PVC nozzle refuse to accept the grout complete including scaffolding upto 12 metre height complete all as specified and directed.
M&L for 15 mm thick polymer modified plaster on external brick or concrete surfaces of wall without using extra cement including a bonding coat with two part solvent free bonding agent composed of liquid epoxy resin & hardener complete all as specified and directed. Make : SIKA/ FOSROC/ STP with same nature of chemical treatment as prescribed above. Note :- The rate inclusive for scaffolding up to 4 metre height of wall.
M&L for 15mm thick ready mix plaster on internal brickwork or concrete surfaces of wall finished even & smooth complete all as specified and directed. Note for item No. 5 to 7:-The complete work of these item shall be executed only by the skilled labour of the trade.
M&L for 10 mm thick polymer modified plaster on ceiling surfaces without using extra cement including a bonding coat with two part solvent free bonding agent composed of liquid epoxy resin & hardener complete all as specified and directed. Make : SIKA/ FOSROC/ STP with same nature of chemical treatment as prescribed above. Note:- The rate inclusive for scaffolding upto 4 metre height of ceiling.
M&L for preparation of new plastered surfaces of ceiling and applying two coat of white wash on complete all as specified and directed.
M&L for Moulding/rounding on brick wall for decorative purpose of any design , not exceeding 15 cm width using polymer modified mortar , smooth finished, complete all as specified and directed.
M&L for Moulding/rounding on brick wall for decorative purpose of any design width exceeding 15 cm but not exceeding 30 cm using polymer modified plaster, smooth finished, complete all as specified and directed.
Dismantling of AC drain pipes upto 100mm dia, jointed in cement mortar complete all as specified and directed.
Dismantling of 150mm dia AC drain pipes, jointed in cement mortar complete all as specified and directed.
S&F PVC (SWR) pipes 110mm bore single socketed, pressure rating 6 kg/cm² in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F PVC(SWR) 110mm bore bends any radius complete all as specified and directed.
S&F PVC(SWR) 150mm bore bends/Tee with access door any radius complete all as specified and directed.
S&F PVC (SWR) pipes 150mm bore single socketed, pressure rating 6 kg/cm² in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F 20mm bore GI tubing medium grade with all fittings and fixed complete to wall, ceiling or laid in floors etc. including taking up or down old steel tubing and connections complete all as specified and directed.
S&F 15mm bore GI tubing medium grade with all fittings and fixed complete to wall, ceiling or laid in floors etc. including taking up or down old steel tubing and connections complete all as specified and directed.
S&F 25mm bore GI tubing medium grade with all fittings and fixed complete to wall, ceiling or laid in floors etc. including taking up or down old steel tubing and connections complete all as specified and directed.
S&F in repair 25 mm bore gun metal, globe or gate valve with iron lever head screwed both ends for iron pipe complete all as specified and directed.
S&F in repair 20 mm bore gun metal, globe or gate valve with iron lever head screwed both ends for iron pipe complete all as specified and directed.
Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar complete all as specified and directed.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M&L for Machine cut Kota stone slab flooring 20-25 mm thick laid over and including 15mm thick screed bed in Cement Mortar 1:6 and jointed with grey cement slurry mixed with pigments to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for Dholpur stone slab 16 to 18 mm thick cladding gang saw cut with machine cut edges, uniform colour of each stone size exceeding 0.25 Sqm and not exceeding 0.5 Sqm fixed with and including one number of SS clamps of flat 30 mm x 2 mm , 150mm long made to shape in each slab, making V groove at top and bottom stone and drilling hole , fixing with & including GI hold fastener of appropriate size, polishing, rubbing including silicon treatment over and including 15 mm thick cement plaster in cement mortar 1:4 complete all as specified and directed.
Demolition of brick work built in Cement mortar or cement lime mortar including all quoins, arches , pillar etc. complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
M&L for Brick work with sub-class `B' bricks using old size bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and directed.
Dismantling water tanks Exc 500 & not exc 1000 litre capacity including ball valve and removing from site complete all as specified and directed.
S&F 1000 litre capacity triple layer Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed.
S&F ball valve 20mm high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball complete all as specified and directed.
S&F mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars;, staging, barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
M&L for two coats of Exterior emulsion paint over and including a coat of primer and a coat of wall care putty applied to achieve uniform, even & smooth surface including complete removal of existing treatment of old wall surfaces complete all as specified and directed.
M&L for applying two coats of cement based paint including preparation of newly plastered wall surfaces complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
M&L for GI powder coated micro perforated micro look false ceiling with fleece clip-in-type, 0.50mm thick, suitable for grid/frame module of 600 mm x 600mm size complete with and including GI powder coated grid consisting of silhouette main T runner 15mm suspended at 1200 mm centre to centre and cross T runner of 15mm size suspended at 600mm centre to centre suspended by 4 mm GI rod from roof slab including steel fastener wall angle and T with interlocking arrangement as required for framing grid suitable for module size 600x600mm ceiling etc. complete all as per specified and directed
S&F for GI frame work for decorative type seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx. 900mm center to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm center to centre including providing and fixing Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having Phillips head with under head cutter at 200 mm centre to centre, including finishing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish formulated jointing compound and 48mm wide fibre tape to provide seamless finish including preparation of newly surfaces of ceiling and applying two coats of ready mix acrylic distemper over and including 1mm thick plaster of Paris complete all as specified and directed.
Dismantling boarding of any description as in paneling any thickness, including cover fillets in any surface complete all as specified and directed.
M&L Providing PVC SHEET WALL PANELING of thickness 5mm ( ±0.25 ) consisting of panels of desired size stuck on inner frame work of 50mm wide strips of 5mm (±0.25 ) thick Prelam PVC sheet. The panel & strips shall have density of 600 Kg /Cum Manufactured by an ISO-9001-2015 certified Company. The strips should have in their center a groove of 6mm width and 1mm depth for sinking the head of the screw used to fix the strips to the wall vertically at an equal interval of 10” between two PVC strips. The PVC strips shall be fixed to the wall using 65mm long M.S. screws through the groove in the strip by using PVC fasteners. The distance between two screws shall not be more than 200mm. A groove of 2mm may be left at the joint of two panels for aesthetic looks. The exact size of the panel and correspondingly of the grid may vary depending on the size of the wall. Optionally a strips of 5mm ( ±0.25 ) thick PVC sheet of width 75mm feathered at the edges shall be stuck at the places where two panels are joined, using solvent cement complete all as specified and directed.
M&L for PVC 'L' angles 25x25mm fixed at where direction changed portion with adhesive or as per manufacture instruction complete all as specified and directed.
S&F second class hard wood plain, solid straight chowkhat and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
M&L for second class hard wood plain fillets square, rectangular or triangular in section, clean swan, secured with nails or brads, exc 13 Sqcm and not exc 25 Sqcm complete all as specified and directed.
M&L for second class hard wood fillets bull nosed splayed, chamfered or rounded on the edge or face, wrought, secured with screws exc 6 Sqcm and not exc 13 Sqcm complete all as specified and directed.
S&F for 12 mm thick plywood grade BWP, type BB fixed with screws to timber frame work complete all as specified and directed.
S&F for 6 mm thick plywood veneered decorative face one side fixed with screws to timber surfaces complete all as specified and directed.
M&L for melamine wood polishing on wooden surfaces of any description width or girth exc. 10 cm including cleaning and preparing the surface including a coat of wood filler on new untreated surfaces works with two or more coats till the smooth surface is achieved complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface 350 x 250 x 7 mm or 450 x 350 x 7 mm thick over and including 10 mm thick rendering 1:4 in cement mortar set and jointed in neat cement slurry and pointed in white or colour cement to match coloured tiles complete all as specified and directed. Note:- Size & colour will be approved by GE.
M&L for Vitrified ceramic tiles(light shade) 10 mm thick (Square/rectangular) polished, area of each tiles exceeding 0.42 Sqm but not exceeding 1 Sqm as in floors, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in Cement Mortar 1:6 complete all as specified and directed. Note:- Size & colour will be approved by GE.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Demolition of cement concrete in ground floors and paving n exc 15cm thickness (below or above ground level) complete all as specified and directed.
M&L for 25mm thick cement concrete 1:2:4 type B-0, (using 12.5mm graded stone aggregate) as in sub base floor complete all as specified and directed.
S&F 10 to 12 mm thick heavy duty coloured digital vitrified parking tiles, area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15 mm thick screed in Cement mortar 1:6 as in floor complete all as specified and directed. Make:-Cera/ Somany/ Orientbell Note:- Size & colour will be approved by GE.
S&F for prepainted galvalume aluminum zinc chrome coating corrugated sheet of 0.50 mm thick of and colour having tensile strength 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified or as per manufacture instructions complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, including wooden battens/trusses complete all as specified and directed.
Taking down chowkhat or frame with shutters without taking off shutters from frames exc 1.5 Sqm but not exc 4.00 Sqm each & removing from site including making good disturbed portion complete all as specified and directed.
M&L for first class teak wood plain, solid, straight chowkhat and frames wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and directed.
S&F first class teak wood 35mm thick panelled shutters plain, framed, panelled shutters ( any number of panels) with panels of timber feather edged teak wood planks supplied and fitted to chowkhat complete all as specified and directed.
S&F first class teak wood 30mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR part-1 section 8, clause 8.24(a) supplied and fitted to chowkhat complete all as specified and directed.
M&L for preparation of old decorated wall surfaces and applying one coat of distemper oil emulsion including cornices etc. complete all as specified and directed.
M&L for factory made coloured solid WPC (wood particle composite) door frame of size 100mmx63 mm double rebate 100% lead free made from single extruded process material with density 0.78 Kg/RM complete all as specified and directed.
M&L for 30 mm thick factory made solid WPC (wood particle composite) moulded door shutter single extruded with 2,4 or 6 raised panel design on the front side with 10 mm deep mould on single side, with wood grain texture. The density of the door shutter not less than 600Kg/Cum should be 100% lead free door complete all as specified and directed.
S&F 4.80 mm thick sheet glass, ordinary quality in square or rectangular not exc 0.50 Sqm in each pane and including solar control film 25 micron reflective type sticked to glass panels on outer side as per instructions of manufacture complete all as specified and directed.
S&F 30 mm thick second class hardwood boarding in floors and skirting planed one side with butt joint and fixed with screws complete all as specified and directed..
M&L for particle board 12mm thick, medium density, flat pressed single layer or three layer type with BWR type adhesive, fixed with screws to timber frame work complete all as specified and directed.
M&L for Preparing surfaces of wood and wood based materials steel and iron work, new or old, of any description, and treated with coal tar black paint complete all as specified and directed.
M&L for mild steel works for Band straps, hooks, pintle hinges, large hasp and staples, chains hand made sliding bolts clamp, hold fasts, any type of angles, wall ties etc. complete all as specified and directed.
M&L for two coats of synthetic enamel paint over and including a coat of primer red oxide/ zinc chromate on steel surfaces of any description in width or girth complete all as specified and directed.
S&F in repairs 15 mm bore Bib taps, quarter turn, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F 200 mm long Brass barrel tower bolts, with brass screws complete all as specified and directed.
S&F 100 mm long Brass barrel tower bolts, with brass screws complete all as specified and directed.
S&F Brass sliding door bolts 250 mm long and fixed with brass screws to wooden doors complete all as specified and directed.
S&F Brass butt hinges 125 mm long type C11 with brass screws fixed to wooden doors complete all as specified and directed
S&F Brass butt hinges 100 mm long type C11 with brass screws fixed to wooden doors complete all as specified and directed
S&F Brass handles 150 mm long polished bright with brass screws complete all as specified and directed.
S&F Brass handles 100 mm long polished bright with brass screws complete all as specified and directed.
S&F Brass gate and shutter hooks and eye 125 mm long complete all as specified and directed.
S&F Brass door stopper tongued with hard drawn steel spring 140 mm long complete all as specified and directed.
S&F for stainless steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F in repair door closer hydraulically regulated designation No 1 universal type, aluminum body suitable for door shutters of up to 700 mm in width and weight not more than 35 Kg and fixed complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver blocks of any shape and size conforming to IS-15658-2006 of 100mm thickness M-50 grade with grey cement and no pigment complete all as specified.
M&L for 25mm thick sand cushioning as on under tiles complete all as specified and directed.
Excavating in trenches, n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc. for manholes, pier holes etc. n exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft and loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point in soil complete all as specified and directed.
M&L for cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete as in drain bed complete all as specified and directed.
M&L for cement concrete 1:2:4 type B2 (using 40mm graded stone aggregate) in drains as PCC coping including formwork complete all as specified and directed.
M&L for 10mm thick rendering in cement and sand mortar 1:4 on fair surfaces of brick work or concrete surfaces finished even and smooth complete all as specified and directed.
Taking down carefully old point wiring (Light / Fan/ Socket/ Bell Point ) with aluminium/ copper conductor cable complete including fittings such as ceiling rose, holders, regulators, bell, switch, socket and light fittings from existing concealed conduits and making good the disturbed surface of wall/ floor complete to match with the existing surface/finishes complete all as specified and directed.
Material and labour for point wiring with PVC insulated unsheathed multi stranded, single core, FRLS, copper conductor cable of size 1.5 Sqmm 1100 Volts including one run of PVC insulated unsheathed multi stranded, single core, FRLS , copper conductor cable of size 1.5 Sqmm as earth continuity conductor connected to common earth dolly drawing through & including new PVC concealed conduit including provn of new galvanised modular concealed box with suitable back & front plate for housing the modular switches, sockets & fan regulators including cutting chase & making good disturbed surfaces complete all as specified and directed for the following :- Notes :- (i) No cutting shall be done in the roof for laying PVC conduit for ceiling point wiring. In this specified portion wire shall run through the existing conduit or new surface conduit shall be provided as required. (ii) In case the wiring is encountered with any beam/column, then the wiring will run on surface to avoid any damage to the RCC portion.
One light/fan point controlled by one No, one way switch.
One 6 Amp socket outlet point controlled by one No, one way switch on same board.
One 6 Amp socket outlet point controlled by one No, one way switch on independent board.
Material and labour for point wiring with PVC insulated unsheathed multi stranded, single core, FRLS, copper conductor cable of size 2.5 Sqmm 1100 Volts including one run of PVC insulated unsheathed multi stranded, single core, FRLS , copper conductor cable of size 2.5 Sqmm as earth continuity conductor connected to common earth dolly drawing through & including new PVC concealed conduit including provn of new galvanised modular concealed box with suitable back & front plate for housing the modular switches, sockets for One 16 Amp socket outlet point controlled by one No, one way switch on independent board including cutting chase & making good disturbed surfaces complete all as specified and directed Notes :- (i) No cutting shall be done in the roof for laying PVC conduit for ceiling point wiring. In this specified portion wire shall run through the existing conduit or surface new conduit shall be provided as required. (ii) In case the wiring is encountered with any beam/column, then the wiring will run on surface to avoid any damage to the RCC portion.
S&F modular switch 1 way 6 Amp, SP, one module 230 volts AC complete all as specified and directed.
S&F modular switch 1 way 16 Amp, SP, one module 230 volts AC complete all as specified and directed.
S&F modular socket out let 2/3 pin combined 6 Amp, 230 volts two module AC complete all as specified and directed.
S&F modular socket out let 2/3 pin combined 6/16 Amp, 230 volts two module AC complete all as specified and directed.
S&F modular type electronic fan step regulator 120W, modular type 2 module complete all as specified and directed.
S&F LED luminaire 595 x 595 x 2 mm, (2'x2') 36 watts, 220 volts AC recessed type with high efficiency PMMA diffuser, soft glare free light complete with suitable driver, holders & including suitable LED lamp suitable for POP/Gypsum/roof ceiling including connecting up with three core twisted flexible copper conductor cable of suitable size from ceiling rose including cutting of false ceiling in suitable size & making good the disturbed surface & matching with the existing surface complete all as specified and directed.
Taking down of sub main wiring including taking out conduit pipe of any description and of any size & making good disturbed surfaces complete all as specified and directed.
S&F of sub main wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 6 Sqmm complete drawn along with 1x 6 Sqmm PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type for continuous earth wire and connected to common earth dolly drawn in & including new PVC conduit & cutting chase if required & making good disturbed surfaces complete all as specified and directed. Note :- Two run of 6 Sqmm copper conductor cable, one run of 6.0 Sqmm copper earth cable and one run of PVC conduit shall be measured as one unit.
S&F of sub main wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 4 Sqmm complete drawn along with 1x 4 Sqmm PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type for continuous earth wire and connected to common earth dolly drawn in & including new PVC conduit & cutting chase if required & making good disturbed surfaces complete all as specified and directed. Note :- Two run of 4.0 Sqmm copper conductor cable, one run of 4.0 Sqmm copper earth cable and one run of PVC conduit shall be measured as one unit .
S&F in repair factory made concealed sheet steel distribution boards, double door, SPN, 8 way, 230 volts AC, IP 43 with suitable busbar, neutral link, earth link suitable for MCB, DP/SPN as incomer & MCB SP as outgoing complete all as specified and directed.
S&F in repair factory made load line DB's double door made out of CRCA mild steel sheet with insulating materials like polyester epoxy coated surface mounting 8 way TPN 415 Volts, IP 43 with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as out going complete all as specified and directed.
S&F in repair MCCB TP 125 Amp, 25kA thermal type complete all as specified and directed.
S&F in repair MCB SP 5-32 Amp, 10kA complete all as specified and directed.
S&F in repair MCB SP 40-63 Amp, 10kA complete all as specified and directed.
S & F of metal clad AC box complete with MCB 20 Amp, 230 volts AC complete all as specified and directed.
Supply and fix wire meshed Hot dip Galvanized cable tray 54mm (h) x 100 mm (w) complete with nuts bolts washers (GI) and all accessories for mounting and supporting the cable tray system, along with vertical bends, bends. including taking down and re fixing any type of electric cable, LAN /signal cable ,if require through and including wall cutting and making to good surface in disturbed area complete all as specified & directed.
Supply & fix Hot dip Galvanized Cover for covering cables on cable tray width 100 mm along with clips and other fixing arrangement complete all as specified & directed.
Supply and fix wire meshed Hot dip Galvanized cable tray 54mm (h) x 200 mm (w) complete with nuts bolts washers (GI) and all accessories for mounting and supporting the cable tray system, along with vertical bends, bends for mounting and supporting the cable tray system, including taking down and re fixing any type of electric cable, LAN /signal cable, if require through and including wall cutting and making good surface in disturbed area complete all as specified & directed.
Supply & fix Hot dip Galvanized Cover for covering cables on cable tray width 200 mm along with clips and other fixing arrangement complete all as specified & directed.
Supply and fix wire meshed Hot dip Galvanized cable tray 54mm (h) x 300 mm (w) complete with nuts bolts washers (GI) and all accessories for mounting and supporting the cable tray system, along with vertical bends, bends for mounting and supporting the cable tray system, including taking down and re fixing any type of electric cable, LAN /signal cable ,if require through wall cutting and making to good surface in disturbed area complete all as specified & directed.
Supply & fix Hot dip Galvanized Cover for covering cables on cable tray width 300 mm along with clips and other fixing arrangement complete all as specified & directed.
Supply and fix wire meshed Hot dip Galvanized cable tray 54mm (h) x 400 mm (w) complete with nuts bolts washers (GI) and all accessories for mounting and supporting the cable tray system, along with vertical bends, bends for mounting and supporting the cable tray system, along with vertical bends, bends. including taking down and re fixing any type of electric cable, LAN /signal cable ,if require through and including wall cutting and making to good surface in disturbed area complete all as specified & directed.
Supply & fix Hot dip Galvanized Cover for covering cables on cable tray width 400 mm along with clips and other fixing arrangement complete all as specified & directed.
Supply and fix wire meshed Hot dip Galvanized cable tray 54mm (h) x 600 mm (w) complete with nuts bolts washers (GI) and all accessories for mounting and supporting the cable tray system, along with vertical bends, bends. for mounting and supporting the cable tray system, including taking down and re fixing any type of electric cable, LAN /signal cable ,if require through and including wall cutting and making to good surface in disturbed area complete all as specified & directed.
Supply & fix Hot dip Galvanized Cover for covering cables on cable tray width 600 mm along with clips and other fixing arrangement complete all as specified & directed.
Supply & fix of GI Raceway made from 1.5mm thick pregalvanized sheet for top, bottom & sides and complete with top cover with rubber gasketing of size 100 x 38mm complete along with vertical bends, including taking down and re fixing any type of electric cable, LAN /signal cable ,if require through wall cutting and making to good surface in disturbed area complete all as specified & directed.
Supply & fix of GI Raceway made from 1.5mm thick pregalvanized sheet for top, bottom & sides and complete with top cover with rubber gasketing of size 300 X 38 mm complete, along with vertical bends, including taking down and re fixing any type of electric cable, LAN /signal cable ,if require through and including wall cutting and making to good surface in disturbed area complete all as specified & directed.
Supply & fix Galvanised angle iron Bracket of size 40.5 x 20 x 5 mm thick, length 142mm for above Raceway of 100 mm complete all as specified and as directed.
Supply & fix Galvanised angle iron Bracket of size 40.5 x 20 x 5 mm thick, length 342mm for above Raceway of 300 mm complete all as specified and as directed.
Supply & fix of GI coupler for above Raceway of 100 mm wide complete all as specified and as directed.
Supply & fix of GI coupler for above Raceway of 300 mm wide complete all as specified and as directed.
Supply and fix Rigid non-metallic concealed PVC conduit 25 mm dia including of boxes (junction/ terminal), tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for LAN/ telephone circuits complete all as specified & directed. Note : Unit rate quoted for this item includes cost of cutting of chases on wall and making good disturbed surfaces.
Supply and fix flexible PVC conduit pipe 40 mm dia fixed on surface including fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for LAN/ telephone circuits complete all as specified & directed.
M&L for one coat of touch wood polishing including cleaning and preparing the surfaces by wood filler wherever required complete all as specified and directed.
JYOTI ENTERPRISES
M/S ANIL KUMAR
SANJEEV ENTERPRISES
M/S Sunil Steel Works
L G BUILDERS
M/S Parshant Associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .