Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.6 LAccepted-Finance | ₹3.6 L | L1 | Accepted-Finance Being lowest |
| 2 | L2₹4.1 LRejected-Finance | ₹4.1 L | L2 | Rejected-Finance Being 2nd lowest |
| Sl No | Description | Qty | Unit | K.Dhanabir Sharma L1 | Moirangthem Inao Meitei L2 |
|---|---|---|---|---|---|
| 1.00Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. | |||||
| 1.01The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : | |||||
| 1.02 | (a) 3 mm thick | 160 | Sqm | 1,100 ₹1.8 L | 1,200 ₹1.9 L |
| 2.00Finishing walls with Acrylic Smooth exterior paint of required shade : | |||||
| 2.01 | (a) New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). | 300 | Sqm | 250 ₹75,000 | 300 ₹90,000 |
| 3.00 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. | 30 | Sqm | 330 ₹9,900 | 350 ₹10,500 |
| 4.00Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. | |||||
| 4.01 | (a) One coat. | 200 | Sqm | 110 ₹22,000 | 120 ₹24,000 |
| 4.02 | (b) Two coats. | 30 | Sqm | 200 ₹6,000 | 300 ₹9,000 |
| 5.00Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge. | |||||
Tender Value
Refer Docs
EMD Value
₹9,493
Closing Date
16 Mar 2026, 3:00 pmClosed
Executive Engineer(C)
BSNL Bhawan 3rnd floor Bapupara Imphal
Waterproofing treatement and special repairs to external surfaces painting and other misc civil works at UHF Building Paomata Manipur 2nd call
2026_BSNL_269477_1
51/EE/BSNL/CD-IMP/2025-26
Open Tender
Civil Works
90 days
Paomata
Please refer Tender documents.
6 documents required · 6 mandatory
₹590
Yes
AO (Claims), O/o Sr GMTD, BSNL Imphal
₹9,493
Yes
23 Mar 2026
3 Mar 2026
18 Mar 2026
3 Mar 2026
16 Mar 2026
3 Mar 2026
3 Mar 2026 - 16 Mar 2026
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete.
The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :
(a) 3 mm thick
Finishing walls with Acrylic Smooth exterior paint of required shade :
(a) New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
(a) One coat.
(b) Two coats.
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge.
(a) With cement mortar 1:4 (1 cement : 4 fine sand).
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
(a) One or more coats on old work.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,
(i)Single socketed pipes.
(a) 75 mm diameter
(b) 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion.
(a) Single tee with door
(i) 110x110x110 mm
(b) Single tee without door
(i) 75x75x75 mm
(ii) 110x110x110 mm
(c )Bend 87.5°
(i) 110 mm bend
(d) Shoe (Plain)
(i) 110 mm Shoe
Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/ mm2).
(a) 25 mm average thickness in 2 layers.
(b) 50 mm average thickness in 3 layers.
Filling cracks in wall surface plaster with Elastomeric Acrylic Crack Filler, readymade paste having auto-suction, impermeable & non-shrink property (Polyfill-AR of Sunanda chemical or equivalent) defining the crack with sharp pointed tool/ power cutter etc., to make it 6 to 8mm-wide & 6mm deep, cleaning mortar dust/ algae etc. with water spray & brush including applying second course of the crack filler wherever required to make up depression formed after first course for all leads and lifts complete all as per directed by Engineer-in-Charge
(Note: The entire wall treated with crack filler shall have to be got approved before commencement of painting or other treatment on wall surface)
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
Tendernotice_2.pdf
PDF • 0.96 MB
BOQ_313875.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid