| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.0 LAccepted-AOC | ₹34.0 L | L1 | Accepted-AOC M/s Anjali Engineers is lowest and accepted. |
| 2 | L2₹37.4 L+₹3.3 L (9.78%)Rejected-Finance 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | ₹37.4 L+₹3.3 L (9.78%) | L2 | Rejected-Finance Not lowest |
| 3 | L3₹38.4 L+₹4.3 L (12.7%)Rejected-Finance 94 5TH FLOOR TOWER D SPENGLE HEIGHTS DHAKOLI KC ZIRAKPUR TEH DERABASSI SAS NAGAR MOHALI PB | S A S NAGAR | PUNJAB | 140103 | ₹38.4 L+₹4.3 L (12.7%) | L3 | Rejected-Finance Not lowest |
| 4 | L4₹41.6 L+₹7.6 L (22.3%)Rejected-Finance 119 LANE NO 4 DAYA NAND NAGAR LAWRENCE ROAD AMRITSAR PUNJAB 143001 | AMRITSAR | PUNJAB | 143001 | ₹41.6 L+₹7.6 L (22.3%) | L4 | Rejected-Finance Not lowest |
| Sl No | Description | Qty | Unit | Raj Construction L2 | india trading company L4 | Satyadev Builders L3 | M/S ANJALI ENGINEERS L1 |
|---|---|---|---|---|---|---|---|
| 1.00Supply & Installation of top discharge hybrid VRF air conditioning system comprising of modular type high efficiency twin rotary multiple compressor with inverter type, high efficiency heat transfer cooling coil suitable for environment friendly R410a refrigerant , air cooled propeller type condenser fan with DC motor drive, interconnecting piping, suction line insulation etc. Micro-processor control panel suitable for automatic operation, high speed calculation inverter control, active oil control mechanism incorporating all safety functions as per equipment specifications & complete all as specified and as listed below:- Note : (i) The unit mounted starter panel shall be complete with IP-55 protection consisting of power disconnecting switches with fuses, starters, for compressor motors, under / over voltage trip relay, single phase preventers, communication card which can accept 4-20 mA or 2-10 Vdc analog signal. (ii) All components shall be mounted on welded steel base frame, structural steel profiles/ panels made out of galvanized sheet steel, protected with primary coat & finished with epoxy paint. (iii) Modular type outdoor units equipped with highly efficient scroll compressors, with inverter type compressor(s), special acryl precoated heat exchanger, low noise condenser fan, auto check function for connection error, auto address & UNIT Price shall be exclusive of outdoor stand price. Shifting & Installing of ODU as per drawing is part VRV vendor scope. (ODU location & capacity mentioned below). Shifting of out door units from GF to Terrace floor is part of VRF vendor scope. (iv) All VRV units should be compatible for third party BMS integration. Necessary bacnet Card / integrator should be consider in part HVAC/VRF vendor scope. (v) All unit COP should meet the Well & LEED requirements. Approx it should be more than 3.4.EER needs to be more than 13 [For >5 TR] | |||||||
| 1.01 | Top Discharge Outdoor Unit (ODU) : Cooling Capacity :40 HP | 1 | Each Set | 25,33,500 ₹25,33,500 | 28,96,580 ₹28,96,580 | 19,00,000 ₹19,00,000 Lowest | 20,00,000 ₹20,00,000 |
| 1.02 | Supply and fixing Indoor Unit (IDU) ductable Cooling type of capacity of serving area 11 TR for each type of Room. Drycontact should be considered for Auto change over, failure status, overload sequencing etc. complete all as specified and directed. | 3 | Each | 1,35,000 ₹4,05,000 Lowest | 1,42,700 ₹4,28,100 | 2,86,000 ₹8,58,000 | 1,50,000 ₹4,50,000 |
| 1.03 | Supply and fixing imported fittings like Y-Joints and headers etc as per the layout required with additional supports at both ends of the Y joint complete all as specified and directed. | 3 | Each | 10,800 ₹32,400 | 11,150 ₹33,450 | 21,600 ₹64,800 | 5,000 ₹15,000 Lowest |
| 2.00Supply and fixing interconnecting copper refrigerant pipe duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units as per specifications complete all as specified and directed for the following seze outer dia:- | |||||||
| 2.01 | (a) 41.3mm OD (insulation =13 mm thick) | 10 | RM | 4,500 ₹45,000 Lowest | 5,250 ₹52,500 | 6,000 ₹60,000 | 5,900 ₹59,000 |
| 2.02 | (b) 34.3mm OD (insulation =13 mm thick) | 10 | RM | 4,000 ₹40,000 Lowest | 4,850 ₹48,500 | 4,450 ₹44,500 | 5,000 ₹50,000 |
| 2.03 | (c ) 28.6mm OD (insulation =13 mm thick | 25 | RM | 3,000 ₹75,000 Lowest | 3,100 ₹77,500 | 3,200 ₹80,000 | 3,100 ₹77,500 |
| 2.04 | (d) 22.2mm OD (insulation =13 mm thick | 20 | RM | 2,000 ₹40,000 | 1,980 ₹39,600 Lowest | 2,250 ₹45,000 | 3,000 ₹60,000 |
| 2.05 | (e ) 19.1mm OD (insulation =13 mm thick | 25 | RM | 2,000 ₹50,000 | 1,900 ₹47,500 Lowest | 2,100 ₹52,500 | 2,000 ₹50,000 |
Tender Value
₹37.9 L
EMD Value
₹75,800
Closing Date
27 Jun 2026, 6:00 pmClosed
CWE Ranchi
Headquarters Commander Works Engineers Ranchi Military Engineer Services Dipatoli Mil Station Hotwar, Ranchi-834009
SPECIAL REPAIR/ REPLACEMENT OF BER AC PLANT FOR MH UNDER GE DANAPUR CANTT
2026_MES_770189_1
80599/1717/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
GE Danapur
As per tender documents
7 documents required · 7 mandatory
₹500
GE Danapur
₹75,800
Yes
HQ CWE Ranchi
29 Aug 2026
6 Jun 2026
4 Jul 2026
6 Jun 2026
27 Jun 2026
20 Jun 2026
6 Jun 2026 - 13 Jun 2026
13 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply & Installation of top discharge hybrid VRF air conditioning system comprising of modular type high efficiency twin rotary multiple compressor with inverter type, high efficiency heat transfer cooling coil suitable for environment friendly R410a refrigerant , air cooled propeller type condenser fan with DC motor drive, interconnecting piping, suction line insulation etc. Micro-processor control panel suitable for automatic operation, high speed calculation inverter control, active oil control mechanism incorporating all safety functions as per equipment specifications & complete all as specified and as listed below:- Note : (i) The unit mounted starter panel shall be complete with IP-55 protection consisting of power disconnecting switches with fuses, starters, for compressor motors, under / over voltage trip relay, single phase preventers, communication card which can accept 4-20 mA or 2-10 Vdc analog signal. (ii) All components shall be mounted on welded steel base frame, structural steel profiles/ panels made out of galvanized sheet steel, protected with primary coat & finished with epoxy paint. (iii) Modular type outdoor units equipped with highly efficient scroll compressors, with inverter type compressor(s), special acryl precoated heat exchanger, low noise condenser fan, auto check function for connection error, auto address & UNIT Price shall be exclusive of outdoor stand price. Shifting & Installing of ODU as per drawing is part VRV vendor scope. (ODU location & capacity mentioned below). Shifting of out door units from GF to Terrace floor is part of VRF vendor scope. (iv) All VRV units should be compatible for third party BMS integration. Necessary bacnet Card / integrator should be consider in part HVAC/VRF vendor scope. (v) All unit COP should meet the Well & LEED requirements. Approx it should be more than 3.4.EER needs to be more than 13 [For >5 TR] | |||||
| 1.01 | Top Discharge Outdoor Unit (ODU) : Cooling Capacity :40 HP | 1 | Each Set | - | - |
| 1.02 | Supply and fixing Indoor Unit (IDU) ductable Cooling type of capacity of serving area 11 TR for each type of Room. Drycontact should be considered for Auto change over, failure status, overload sequencing etc. complete all as specified and directed. | 3 | Each | - | - |
| 1.03 | Supply and fixing imported fittings like Y-Joints and headers etc as per the layout required with additional supports at both ends of the Y joint complete all as specified and directed. | 3 | Each | - | - |
| 2Supply and fixing interconnecting copper refrigerant pipe duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units as per specifications complete all as specified and directed for the following seze outer dia:- | |||||
| 2.01 | (a) 41.3mm OD (insulation =13 mm thick) | 10 | RM | - | - |
| 2.02 | (b) 34.3mm OD (insulation =13 mm thick) | 10 | RM | - | - |
| 2.03 | (c ) 28.6mm OD (insulation =13 mm thick | 25 | RM | - | - |
| 2.04 | (d) 22.2mm OD (insulation =13 mm thick | 20 | RM | - | - |
| 2.05 | (e ) 19.1mm OD (insulation =13 mm thick | 25 | RM | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
1717TENDER.pdf
Tender Documents • 1.04 MB
BOQ_862515.xls
BOQ • 0.75 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .