Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹15.7 L+₹35,918.50 (2.34%)Rejected-Finance OPPOSITE GHOOM DRC PO GHOOM DISTT DARJEELING WB PIN 734 102 | DARJEELING | WEST BENGAL | 734102 | L2 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 3 | L3₹16.6 L+₹1.2 L (7.92%)Rejected-Finance | L3 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 4 | L4₹16.6 L+₹1.2 L (8.04%)Rejected-Finance | L4 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 5 | L5₹16.8 L+₹1.5 L (9.72%)Rejected-Finance DARJEELING DHOTREY FOREST BANSBOTAY DARJEELING P S DARJEELING DHOTREY FOREST BANSBOTAY DARJEELING P S DARJEELING DARJEELING WEST BENGAL 734201 | DARJEELING | WEST BENGAL | 734201 | L5 | Rejected-Finance HIGHER THEN L1 BIDDER |
Tender Value
₹14.4 L
EMD Value
₹29,000
Closing Date
16 Aug 2023, 6:00 pmClosed
CWE
HQ 136 WORKS ENGINEERS PIN - 914136 C/O 99 APO
PROVN OF TILING AND FALSE CEILING IN BLDG NO P-120 AND PARKING SHED FOR BLDG NO P-03 AT LEBONG UNDER AGE (I) DARJEELING
2023_MES_610558_1
CWE/136-WE/25 of 2023-24
Open Tender
Civil Works
Item Rate
180 days
Darjeeling
Class E, Category a(I)
9 documents required · 9 mandatory
₹500
AGE (I) Darjeeling
₹29,000
6 Sept 2023
25 Jul 2023
17 Aug 2023
25 Jul 2023
16 Aug 2023
9 Aug 2023
25 Jul 2023 - 1 Aug 2023
Amount
Excavation in post holes in soft/loose soil or similar holes each n exc 0.5 cum getting out returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm and remaning surplus soil removing to a distance n exc 50cm and making good surface, complete all as specified and directed.
M&L for plain cement concrete (1:3:6), type C1 (using 20mm graded crushed stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed.
S&F of rolled mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified and directed.
S&F of pre-painted galvalume aluminum zinc coating GI based corrugated / plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws, complete all as specified and directed
S&F of mild steel framed work such as steel gate for framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc. conforming to Fe.290.Gde-E-165, complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
M&L for providing precast cement concrete (1:3:6), type C1 (using 20mm graded stone aggregate) as in landings, cover slabs (for man holes, drain etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces with plain fair faces, including chamfers, weatherings, throat- ing etc. and set in cement mortar (1:4), complete with joints to match complete all as specified and directed.
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation, complete all as specified and directed.
M&L for providing machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment, complete all as specified and directed.
Removal of surplus excavated soils to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point, complete all as specified and directed.
M&L for brickwork with fly ash bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in cement mortar(1:6), complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick work or concrete surface in cement mortar (1:4) on external wall finished even and smooth (without using extra lime or cement), complete all as specified and directed.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of white wash on walls, complete all as specified and directed.
M&L for preparation of new plastered or unplastered surface of wall and applying two coats of cement paint over a coat of alkali resistant priming paint, complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc., complete all as specified and directed.
M&L for 15 mm thick screed bed or bedding layer of cement mortar (1:6) for laying floor finishes even and rough, complete all as specified and directed.
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tiles, complete all as specified and directed.
M&L for machine cut Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, complete all as specified and directed.
M&L for chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and no pigments, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar (1:3) on fair faces of brick work or concrete surfaces, complete all as specified and directed.
M&L for coloured glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the surface of tiles, complete all as specified and directed.
M&L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified and directed.
Taking up or down old 15 mm bore steel water tubing and connections, including cleaning for refixing or removal to store or from site, complete all as specified and directed.
S&F of 15 mm bore steel water tubes, medium grade, galvanised with and including all GI fitting (such as bends, elbows, Tees, connectors, short pieces, back nuts, unions, caps and plug etc ) and fixed complete to wall and ceiling or laid in/on floor, complete all as specified and directed.
S&F in repairs of 15mm bore dia bib taps, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets, complete all as specified and directed.
S&F of anodised aluminium snap grid frame work of size of grid 605mm x 605mm for false ceiling, complete all as specified and directed.
M&L for 4mm thick non asbestos fibre cement building boards fixed or laid / inserted to timber / GI / aluminium framework with screws in ceiling flat or sloping, complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc., complete all as specified and directed.
Taking down carefully sub main wiring of any size/core/type including conduit/ cashing/ batten of any type and making good disturbed surfaces to match with the existing surface roof/ wall/ floor, complete all as specified and directed.
Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of required size (not less than 20mm) conforming to IS 2079-1973, medium grade with all necessary fittings, surface wiring for one light point or one fan point or one bell point controlled by one switch, with 1.5 Sq mm PVC insulated and unsheathed copper conductor for earth continuity conductor and making good disturbed surfaces to match with the existing surface roof/wall/floor, complete all as specified and directed including testing on completion.
Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of required size (not less than 20mm) conforming to IS 2079-1973, medium grade with all necessary fittings, surface wiring for one 3 pin socket outlet, 5 Amps on the same board with other switches, with 1.5 Sq mm PVC insulated and unsheathed copper conductor for earth continuity conductor and making good disturbed surfaces to match with the existing surface roof/wall/floor, complete all as specified and directed including testing on completion.
Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of required size (not less than 20mm) conforming to IS 2079-1973, medium grade with all necessary fittings, surface wiring for one 3 pin socket outlet, 5 Amps on independent board, with 1.5 Sq mm PVC insulated and unsheathed copper conductor for earth continuity conductor and making good disturbed surfaces to match with the existing surface roof/wall/floor, complete all as specified and directed including testing on completion.
Material and labour for point wiring with 2.5 Sqmm (nominal area) PVC insulated un-sheathed single core multi stranded copper conductor FRLSH cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping of required size (not less than 25mm) conforming to IS 2079-1973, medium grade with all necessary fittings, surface wiring for one 6 pin socket outlet, 15 Amps on independent board, with 2.5 Sq mm PVC insulated and unsheathed copper conductor for earth continuity conductor and making good disturbed surfaces to match with the existing surface roof/wall/floor, complete all as specified and directed including testing on completion.
S&F of switch piano, flush type single pole, one way, 5 Amps / 6 Amp, 240 Volts, all as specified and directed.
M&L for socket outlet 2 in 1, 3 pin, 5 Amps / 6 Amps flush type, 240 Volts, all as specified and directed.
M&L for switch socket combination 2 in 1, 5 Amps / 6 Amps flush type, 240 Volts, all as specified and directed.
M&L for switch socket combination 3 pin 5Amp / 16 Amp, 5 in 1, flush type, 240 Volts, all as specified and directed.
M&L for ceiling rose, 3 phase/PVC/ polycarbonate, isolated body, three terminal, 240 Volts, all as specified and directed.
Supply and fixing in repair / replacement of LED lights fitting 4 feet, 1x 20W, 230V, AC decorative box type with high lumen output, environmental friendly, energy efficient including LED tube light and bipin holder, connector block, driver etc. with all accessories internally pre-wired connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, all as specified and directed.
Supply and fixing in repair / replacement of LED tube lights fitting 1X10W, energy efficient including LED tube light and bipin holder, connector block, driver etc. with all accessories internally pre-wired connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, all as specified and directed.
Supply and fixing in repair / replacement of building security light fittings new generation energy saving and enviornmental friendly long life versatile pressure die-cast aluminium IP66 protection with acrylic cover of LED 25 Watts luminaire including GI bracket of suitable size with clamp, complete all as specified and directed.
Supply and fixing in repair / replacement of LED slim square panel light fitting with frame 30W, 2 x 2 feet with all accessories internally pre-wired connecting up with three core flexible copper conductor cable of suitable size, all as specified and directed.
S&F of sub main wiring with two single core 4.0 Sqmm PVC (FRLSH) copper conductor, insulated multistranded unsheathed cable medium grade including PVC casing caping of required size with accessories for sub main connection including 4.0 Sqmm FRLSH insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly, all as specified and directed. (Note :- Three runs of 4.0 sqmm PVC FRLSH copper conductor shall be measured as one unit length).
Supply and fixing of single pole and neutral (SPN) DB with sheet metal enclosure, 8 way, single door, 415 volt, vertical type, IP-53 with 200 amps rated bus bar including fixing on suitable rectangular block, complete all as specified and directed.
Supply and fixing of 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole (SP) and current carrying capacity of 5 To 32 AMP in the MCB DB complete with connection testing and commissioning, all as specified and directed.
Supply and fixing of 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole & neutral (SPN) and current carrying capacity of 40 to 63 AMP in the MCB DB complete with connection testing and commissioning, all as specified and directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 60cm × 60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron or steel earth lead wire 4.0mm dia size by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES SSR Part-I, connected to earthing test point all as specified or indicated including testing on completion, including necessary excavation and earth work in any type of soil, GI pipe 20mm dia light grade for watering and GI 15mm dia light grade pipe for protection of earth wire upto DB / test point from earth plate etc., PCC chamber with PCC cover in cement concrete (1:2:4), type B1 (using 20mm graded stone aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to DB as indicated, complete all as specified and as directed. Notes: Contractor should conduct necessary test such as earth continuity, earth resistance test in presence of Engineer-in-Charge.
Note 1:- (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum / amendments and general condition of contracts before entry / quoting the rates. Note 2:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount.
Damdoo Bhutia
BIMAL BHATTRAI
M/S TSHERING BHUTIA
REEMA TAMANG AND SONS
SANJAY KAUSHIK
KWOK YING CHIU
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .