Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.7 LAccepted-AOC H NO 113 APR COLONY KATANGA CANTT JABALPUR M P PIN 482001 | JABALPUR | MADHYA PRADESH | 482001 | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹41.7 L+₹3.5 L (9.15%)Rejected-Finance 1409 512 PREM NAGAR MADAN MAHAL JABALPUR M P | JABALPUR | MADHYA PRADESH | 482002 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹42.9 L+₹4.6 L (12.1%)Rejected-Finance 116 JAI BHEEM NAGAR POLIPATHAR GWARIGHAT ROAD JABALPUR MP 482008 | JABALPUR | MADHYA PRADESH | 482008 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹43.5 L+₹5.2 L (13.7%)Rejected-Finance 116 JAI BHEEM NAGAR POLIPATHAR GWARIGHAT ROAD JABALPUR MP 482008 | JABALPUR | MADHYA PRADESH | 482008 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹44.9 L+₹6.7 L (17.5%)Rejected-Finance 28 PRAGATISHEEL COLONY NARMADA ROAD JABALPUR 482001 M P | JABALPUR | JABALPUR | MADHYA PRADESH | 482001 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹48.2 L
EMD Value
₹96,361
Closing Date
21 Nov 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
SPL REPAIR TO JCOS/OR MD ACCN NO P-199/3 AND P-199/5 AT MALKIT ENCLAVE OF JAK RIF RC UNDER GE (WEST) JABALPUR
2024_MES_681386_1
8810/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Jabalpur
As per tender documents
6 documents required · 6 mandatory
₹500
GE (West) Jabalpur
₹96,361
26 Dec 2024
25 Oct 2024
23 Nov 2024
26 Oct 2024
21 Nov 2024
7 Nov 2024
26 Oct 2024 - 2 Nov 2024
Amount
Taking up or down, existing steel tubing and connections of 20mm bore including cleaning for refixing or removal to stores complete all as specified and as directed
Taking up or down, existing steel tubing and connections of 15mm bore including cleaning for refixing or removal to stores complete all as specified and as directed
Dismantling water tanks and removing to store of capicity 500 ltrs to 1000 ltrs complete all as specified and as directed
Removing old tar felt, all loose dirt,old roof tiles,including taking down cement plaster cleaning the concrete surface including removal & cleaning of vegetation, fungus,moss small trees etc from the roof top with wire brush, removing the strips of lightening conductor including refixing the same after repair work complete all as specified and as directed.
Taking down chowkats or frames (without taking off shutter from the frame) of size exc 1.5 Sqm but n.exc 4.00 sqm each complete all as specified and as directed.
Taking down chowkats or frames (without taking off shutter from the frame) of size n exc 1.5 Sqm each complete all as specified and as directed.
Taking down Shutters of size n exc 1.0 sqm each complete all as specified and as directed.
Taking down shutters of any description of size exc 1.00 sqm but n.exc 2.00 sqm each resecuring, easing , adjusting and re-fixing in same opening after minor repairs including all necessary fittings complete all as specified and as directed.
Demolition of brick /stone walls built in cement mortar incl all quoins, arches, pillars etc, but excluding ashler facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Dismantling of Stone slabs and kota stone,Cuddappa stone, Granite, Chequered tiles, Paver block, etc of any description or thickness in floors, aprons etc. laid bedded and pointed in any cement mortar complete all as specified and as directed.
Dismantling floor hearth or wall tilling including cement mortar bedding (but not backing ) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floor or pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and as directed.
Supply & laying of CPVC pipes 20 mm Outer dia, SDR 11 & Plain CPVC SDR 11 fitting on wall/ceiling or laying in floors including chase cutting and fixing with solvant suitable for CPVC pipe and brass treaded fittings for fixing taps and valves, complete all as specified and as directed.
Supply & laying of CPVC pipes 25 mm Outer dia, SDR 11 & Plain CPVC SDR 11 fitting on wall/ceiling or laying in floors including chase cutting and fixing with solvant suitable for CPVC pipe and brass treaded fittings for fixing taps and valves, complete all as specified and as directed.
M&L for 10mm thick rendering on fair faces of brick or concrete surfaces of wall in CM 1:6 including taking down old plaster,complete all as specified and as directed
M&L for 5 mm thick rendering on fair faces of brick or concrete surfaces of ceiling in CM 1:3 including taking down old plaster, complete all as specified and as directed
M&L for 15 mm thick (in two layers 10mm+5mm) cemet plalster in CM 1:4 over brick wall / concrete surfaces using WPC, finished even and smooth without using extra cement, including taking down old plaster,complete all as specified and directed. Note:WPC shall be measurd and paid separately.
M&L for three layered Rotational moulded polyethylene water storage tanks of capacity 1000 ltrs(cylindrical vertical with closed top) hoisted and fixed in position including cover complete all as specified and as directed.
S&F for 20 mm dia Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed.
M&L for 10mm thick rendering on fair faces of brick or concrete surfaces in CM 1:4 mixed with water proofing compound @ 3 % by weight of cement on concrete roof surface finished fair and even to maintain the proper slope of roof surface etc,including taking down old plaster,complete all as specified and as directed. Note: WPC shall be measurd and paid separately.
M&L for Applying evenly a coat of blown type bitumen at the rate of 0.30 kg per square metre complete all as specified and as directed.
M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and as directed.
M&L for Applying two coats of aluminum paint on top of membrane @ 0.20Kg/Sqm complete all as specified and as directed.
M&L for Cement concrete tiles 20cm x 20cm x 20mm thick with grey cement and pigment complete all as specified and as directed.
S&F for Pressed steel frames made of 1.25 mm thick MS Sheet size 125x60mm for doors, with double rebates including necessary fixing lugs, hinges, lock strike plate etc, and making good complete all as specified and as directed.
S&F for Pressed steel frames made of 1.25 mm thick MS Sheet size 105x60mm for doors, with single rebates including necessary fixing lugs, hinges, lock strike plate etc, and making good complete all as specified and as directed.
S&F for 35 mm factory made shutters of second class hard wood Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated supplied and fitted to chowkat complete all as specified and as directed.
M&L for 35 mm thick 2nd class hard wood glazed/gaused and skelton door shutter, factory made, open rebated and prepared to receive glass/guage etc. (without sash bar) edge of frames plain, chamfered or rounded, fitted with cut & mitred beads for securing glass/guage etc size of member as specified in SSR Part I Section 8 clause 8.24(a) and fixed to chowkat including stainless steel wire mess complete all as specified and as directed.
M&L for cement concrete type B1 1:2:4 (using 20mm graded stone aggregate)as in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs,Hold fast and similar works water troughs and the like including weathering, slightly rouinded for chamfered angles and necessary formwork complete all as specified and as directed.
S&F Factory made internal PVC door frame of size 50x47mm single revated made out of extruded 5 mm PVC foam sheet, mitre cut at two corners and jointed with 02 Nos of 150 mm brackets of 15x15 mm MS square tube. The two vertical door profiles are to be in forced with 40x20 mm MS tube of 19 gauge through out the frame complete all as specified and as directed.
S&F 24 mm thick PVC flush door shutter having one side lamination with 2mm thick rigid PVC prelaminated sheet and 2mm thick plain rigid PVC sheet on other side consisting of frame made out of MS tubes of 19 guage thickness and size of 19 mm x 19 mm for stiles wa well as top, bottom & lock rail. MS frame shall have a coat of metal primer of approved make and manufacturer. The inside panel shall consist of 20 mm thick multi chamber Hollow PVC section, bonded using solvent cement/eynoacrylate adhesive with 5mm (+_0.25) thick Prelam PVC sheet of denisity 600 Kg/Cbn manufacured by an ISO-9001-2015 certified company, on both side of the inside panel. Door to be fixed with frame with 3 nos stainless steel butt hinges of size 100 mm x 25 mm x 2 mm and 50 mm long steel screws drilled suitable to pass through both the walls of MS tube other hardware's should be fixed with 25 mm x 8 mm size steel screws etc, including 75 mm PTMT hige, complete all as specified and as directed.
S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed
M&L for 200mm long Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed.
M&L for 150 mm long aluminium anodised handles, oval type, stove enamelled black complete all as specified and as directed.
S&F 75mm long Butt hinges of extruded aluminium alloy, and fixed complete all as specified and as directed.
M&L for 150 mm long Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed.
S&F in repairs 140 mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring as in floor complete all as specified and as directed.
S & F Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples in window, ventilator complete all as specified and as directed.
S&F powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
S&F for powder coated aluminium door,window and ventilator shutters, fixed type without sash bar, aluminium section weighing on site(only aluminium section), including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and as directed.
M&L for Machine cut cudappa stone slab 20-25mm thick as in Shelf/cooking platforms, and like including cutting and fixing over 15mm thick cement screed base in CM (1:4) and jointed to support granite top complete all as specified and as directed.
M&L for zed granite Black Work 18 to 20 mm thick (table rubbed and polished ) as in cooking platforms, and like over 15mm thick cement screed base in CM (1:4) including pointing with white cement (1:2) using marble dust with admixture pigment to match with shade of slab and rounding to edges complete all as specified and as directed.
M&L for Granite tiles 18 to 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 15 mm thick screed bed of CM (1:4) , as in tread and riser of staircase,steps , jambs, pillars, window- cills, complete complete as specified and as directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed
M&L Machine cut kota stone slab flooring 20-25mm thick over 15mm thick screed bed or bedding layer in CM 1:6 jointed with grey cement slurry mixed with pigment to match the shade of the slab, for steps,floor, including rubbing and mirror polishing complete all as specified and as directed
M&L Machine cut kota stone slab 20-25mm thick as in riser of steps, skirting, dado and pillar, over and including 10mm thick cement plaster in CM 1:4 on fair faces of brick work or concrete surface as in backing and jointed with grey cement slurry mixed with pigment to match the shade of the slab, , including rubbing and polishing complete all as specified and as directed
M&L for Non - skid coloured digital Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. over and including 15 mm thick screed bed in CM 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match the floor complete all as specified and as directed.
M&L for Non - skid coloured digital Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. over and including 15 mm thick screed bed in CM 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match the floor complete all as specified and as directed.
M&L for Glazed coloured digital Ceramic tiles in vertifical surface 350x 250x 7mm/ 450X 350X 7mm thick with necessary border over and including 10mm thick renderting/ backcoating in cement mortar 1:4 etc set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and as directed
M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. over and including 15 mm thick screed bed in cement mortar (1:4) set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, over and including 10 mm thick rendering in cement mortar (1:4) as in skirting,dado etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for 25 mm thick PCC 1:2:4 type B-0 using 12.5mm crushed stone aggregate as in leveling course Iincluding demolition of existing PCC complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
S&F mild steel, Fe 410-W (Gde E- 250 quality-A) Framed work such as railings, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
S&F for frame work such as window grill, grating etc of square bars, flat iron with ends bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors and similar work confirming to Fe 290 Gde E-165 complete all as specified and as directed.
M&L for 50 mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate laid in panels surface finish even and smooth using extra cement as in plinth protection, hard standing and similar works, complete all as specified and as directed.
M&L for Brick work using old size bricks with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and as directed.
Ditto all as per Srl item No 59 above but except brick.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer on new steel and iron surfaces of any description not otherwise described over 10 cm width or girth including preparation complete all as specified and as directed.
M&L for applying one coat of synthetic enamel paint on old steel and iron surfaces of any description not otherwise described over 10 cm width or girth including preparation complete all as specified and as directed.
M&L for applying two coats of synthetic enamel paint over a coat of pink primer on new wooden surfaces of any description not otherwise described over 10 cm width or girth including preparation complete all as specified and as directed.
M&L for applying one coat of synthetic enamel paint on old wood or wood based surfaces of any description over 10 cm width or girth including preparation complete all as specified and as directed.
Complete removal of existing treatment of wall surface complete all as specified and as directed.
M&L for applying 2 mm thick wall care putty on New or old plastered wall surfaces and to get smooth and even surfaces of wall including Priming complete all as specified and as directed.
M & L for one coat of oil bound distemper on primed surfaces complete all as specified and as directed.
M & L for subsequent coat of oil bound distemper on wall surfaces complete all as specified and as directed.
M & L for applying three coats of white wash on New plastered surfaces of ceilig complete all as specified and as directed.
M & L complete removal of existing treatment of ceilig and applying two coats of white wash complete all as specified and as directed.
M&L for Preparation of new wall surface/complete removal of existing treatment on wall surfaces of any description including brooming down with steel wire brushing, scrapping down smoke soot's , moulds, moss and efflorescence, salts, trading oil and greasy spots etc and applying two coats of Anti fungal weather proof grade exterior acrylic emulsion paint of approved tint over a coat of weather proof primer including filling the cracks etc with crack filling upto 5 bars of positive hydrostatic pressure on vertical walls without any dilution with forced coverage not more than 3.5 Sqm / Ltr as per manufacture's instruction and all coats incl primer to be applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSIAllow 6-8 hrs to dry the surface in subsequent coats of paint complete all as specified and directed Make: (Apex Ultima Protek Asianpaints/ Nerolac excel top guard / Berger weathercoat long life 10 )
S&F in repair vitreous china wash basin white flat back size 550x400 mm with peddestal, including, sawn neck pillar tap, 32 mm dia CP waste coupling and PVC waste pipe 610 mm long and brackets complete all as specified and as directed.
S & F in repair water closet (Squat Pattern) complete including provn of lime concrete bedding Orissa pattern size 580 x 440mm white with integral foot rests (excluding flushing cisterns) including connection to trap and flushing pipe anti syphonage pipe etc complete and making good to floor to match with existing complete all as specified and as directed.
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white fixed as in repair with all required fittings,complete all as specified and as directed.
S & F in repairs PVC High/Low level flushing cistern 10 litrescapacity including all fittings I.e float valve, syphon, flushpipe,brackets complete all as specified and as directed.
S&F, in repair kitchen sink with drainage board made out of 1mm thick stainless steel with plugs, washers & wastes including CI cantilever bracket & connection union to pipe over all size 915mmx460mm & bowl size 410 x330x160mm complete all as specified and as directed.
S&F in repair 15 mm bore Stop valves/angle cock, cast copper alloy,screwed down,high pressure,with crutch or butterfly handle,conceledd,fancy type, screwed both ends for iron pipe or for unions complete all as specified and as directed.
Supply only Liquid water proofing compound complete all as specified and as directed.
S & F in repair Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed.
S&F in repair PVC connections 15mm dia with PTMT nut on both ends and washers 450mm long complete all as specified and as directed.
S & F in repair 15 mm dia, bib taps cast copper alloy CP with butterfly handle screwed down screwed for iron pipe or for brass ferrule 15mm bore dia complete all as specified and as directed.
S & F in repair 15 mm dia, fancy type sawn neck bib taps cast copper alloy CP with butterfly handle screwed down screwed for iron pipe or for brass ferrule 15mm bore for sink, dia complete all as specified and as directed.
S&F PVC (SWR) gully trap 125/110 mm,setting and jointing with solvent cement grating complete all as specified and as directed.
S&F in repair PVC floor trap square type with CP grating with or without hole including provision of jointing to waste pipes in run lead joint dia of outlet 75 mm, complete all as specified and as directed.
S&F in repair towel rail 450 mm long of Brass CP fixed with and including chromium plated brass screw and wooden / plastics cleats ( min wt 170 gms) complete all as specified and as directed.
S&F in repair for stainless steel kitchen plate rack SIZE (24"X36"X10") three tire ISI marked, including all fittings complete all as specified and as directed.
S & F in repair of 110 mm dia PVC (SWR) pipe single socketed in any length with rubber ring joints laid in trenches,floor and wall including taking down old unserviceable pipe any description and any type complete all as specified and as directed.
S & F in repairs PVC (SWR) Pipes single socketed in any length with rubberring joints laid in trenches or in floors and wall 75mm bore including taking down old unserviceable pipe any description and any type complete all as specified.
S&F 110mm dia (bore of pipe) PVC bends (any radius), diminishing pieces or tapers (larger bore measured) with cement joints, complete all as specified and as directed.
S&F in repairs PVC (SWR) bends 75mm dia bore any radius with access door complete all as specified and as directed.
S&F in repairs 75mm bore PVC (SWR) junction single (Single T) equal or unequal complete all as specified and as directed.
S&F in repairs 110mm bore PVC (SWR) junction single (Single T) equal or unequal complete all as specified and as directed.
S&F in repairs 110mm bore PVC (SWR) vent cowl complete all as specified and as directed.
S&F for Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and as directed.
S&F in repairs Stainless steel fancy type curain rod 25 mm including SS brackets, decorative knobs,and including all necessary fittings such as rawl plug screws complete all as specified and as directed.
S&F for sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed .
S&F in repair 18/19 mm thick water proof block board of commercial quality Gde-I fixed with screws as kitchen,cup board's shelves etc complete all as specified and as directed
S&F in repair 18 mm thick ply , PVC sheet Prelaminated on one side with approved texture as approved by GE as in kitchen cabinet ( with shelves and partition ) including necessary fittings & fixtures as per manufacture's instrucions complete all as specified and as directed.
M&L for 6 mm thick cover fillets of standard hard board ,40 mm wide and fixing with screws complete all as specified and as directed.
S&F for 1st class HW Beads, straight ( 20 mm cross section size) for glazed or gauzed joinery, renewed, including mitres etc., and removing old beads to store (Plain or moulding as requirement) as in cupboard,kitchen etc complete all as specified and as directed.
S&F for 30 mm wide Steel Continous (piano) hinge, steel bright finish or electro galvanised etc complete all as specified and as direcated
S&F in repair 40 mm dia , SS cupboard knobs fixed with nut ,screw and washer of mild steel bright complete all as specified and as directed.
M&L for 100mm thick cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in sub base of floor complete all as specified and as directed.
M&L for 75 mm thick Cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in sub base complete all as specified and as directed.
M&L Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Material and labour for crushed stone dust/sand filling under floors or in foundations including watering and consolidation complete all as directed by Engr-in-Charge.
M&L for 60mm thick machine pressed glossy finish precast concrete interlocking paver block any shape and size & Colour M-40 grade with grey cement and pigment confirming to IS 15658-2006 complete all as specified and as directed.
M&L for Cement concrete(1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
S&F for Europa cupboard locks complete all as specified and as directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground embeded in concrete, complete all as specified and as directed.
Dismantling fencing wire mesh, any type complete all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard dense soil complete all as speicfied and as directed.
M&Lfor Mild steel works as in posts and struts,purlin,rafter,truss,Circular pipe, square section, angle iron, flat iron, Nut bolt, etc, cutting tops to shape as directed, drilling holes, all necessary drilling, bolting or riveting, etc; including embeding in concrete and screwing etc. and similar work conforming to Fe-290 Gde E-165 complete all as speicfied and as directed.
M&L for plain cement concrete 1:2:4 type B2 (using 40 mm graded stone aggregates) as in post holes complete all as speicfied and as directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as speicfied and as directed.
Supply only Chain link MS galvanised fencing, any size or type complete all as speicfied and as directed.
S&F Round Bar 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips,Fe-410-W (Gde.E-250) quality-A or Fe 290 (Gde - E-165) complete all as specified and as directed.
S&F in repair Health Faucet with 1 meter SS Braided connection pipe complete all as specified and as directed .
S&F in Repair wall mixture three in one with complete accessories, complete all as specified and as directed .
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. and n exc 10 sq m on plan and getting out as in soft/loose soil, complete all as specified and as directed.
Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete ) set in cement mortor for 150 mm internal dia of pipe complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thickness complete all as specified and as directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point,complete all as specified and as directed.
Supply, laying and testing of 150 mm inner diameter of double wall corrugated (DWC) high density polethelene pipes(HDPE) and stiffness class-8 (SN-8) with ISI marked (with CML No) with and including all fittings & jointing materials for sewage lineand laid in trenches as specified in IS-16098(Part-2):2013 and as per manufacturer's instruction complete all as specified and as directed. Note:- Bedding of pipe shall not be provided in normal condition and construction methods shall be strictly compiled as per clause no A-4 Annex 'A' of IS 16098(Part-2):2013
S&F SFRC MH Cover with Frame of size Size 900x560 srounded with steel strip 70 x 1.5 mm Reinforced as per manufacturer's design in Manufactured proccess laid over existing Man hole, confirming to IS 12592:2002 HD 20 grade,including reinforcement, complete all as specified and as directed. Note: Contractor shall provide PV alongwith manufacturer test certificate of SFRC cover.
Supply & providing water proofing treatment with polymeric standard water proofing membrane, Aquaflex of 10 years gurantee for water tightness complete all as specified and described as under:- (a) Preparation of sunken surfaceproviding 10 mm thick rendering in cement mortar 1:4 mixed with WPC @ 2 % by weight of cement and applying one coat of polymeric modified bitumen 85/25 @ 1.2Kg/Sqm over a coat of polymeric primer @ 0.30 Kg/sqm including cleaning surface all as per manufaturer's specification complete all as specified and directed. (b) Supply & providing water proofing with polymeric proofing membran of 3Kg/Sqm HYPERPLAS STANDARD/ MULTIPLAS STANDARD consisting of 100micron HMHDPE film centre core including coating the surface with compatible primer and torch application of membrane with 10cm overlaps as required thereof, complete all as specified and directed. (c) GI pipe 40m bore light grade shall be embedded as outlet at the lowest portion for slope on the wall extending upto at least 450 mm beyond the outer wall
Providing and injecting chemical emulsion for Post Constructional Antitermite TreatmentAlong the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling plugging holes etc. in apron complete all as specified and as directed .
Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and as directed .
Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete all as specified and as directed .
Taking down carefully any type point wiring (light, fan, socket bell or power) , complete with fitting such as switches ceiling roses,lamp holders sockets,regulators,call bell light fitting with PVC conduit surface /concealed or wooden pattens including sunken cast iron /pressed steel terminal boxes etc and making good the disturbed surfaces of walls, roof, floors etc to match with the existing surfaces complete all as specified and as directed.
Taking down carefully Main switch and Distribution boards of any make and size complete all as specified and as directed.
Taking down carefully ceiling fan/Exhaust Fan of any sweep and size and depositing to MES store and Hanging only ceiling fan (M.D.supply) and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and as directed .
Taking down carefully Old unserviceable any type sub main wiring with wooden batten/PVC surface conduit of any size and making good the disturbed surfaces of walls, roof, floors etc to match with the existing surfaces complete all as specified and as directed.
M/L for Sub Main Wiring two single core PVC insulated cable of size 6.0 Sqmm multistranded copper conductor two run drawing into and including concealed rigid non-metallic PVC conduit, medium grade not less than 25mm dia with all conduit fitting,fixing accessories and one run of 6.0 Sqmm multistrand copper conductor cable as continuous earth wire complete all as specified and as directed. Note :-Two Nos of 6.0 Sqmm Wire and one No of 6.0 Sqmm Earth wire in One RM length Measured as one unit length.
M/L for Sub Main Wiring with two single core PVC insulated cable of size 4.0 Sqmm multistranded copper conductor drawing into and including concealed rigid non-metallic PVC conduit, medium grade not less than 20mm dia with all conduit fitting,fixing accessories and 4.00 Sqmm multistrand copper conductor cable as continuous earth wire complete all as specified and as directed. Note :- Two Nos of 4.00 Sqmm Wire and One No of 4.00 Sqmm Earth wire in One RM length Measured as one unit length.
M&L for Point wiring with PVC insulated 1.5 sq mm multi stranded copper conductor cable 1100 volts grade drawn into and including concealed PVC conduit not less than 20mm (ISI marked) including all fitting and fixing accessories including sunk in cast iron/pressed steel terminal boxes duly painted with two coats of antirorrrosive paint outside and two coats of aluminium paint inside, 2.8mm thick hylam brand laminated white bakelite sheet cover for mounting of switches, sockets, fan regulators etc and PVC insulated 1.5 Sqmm multistranded copper conductor cable as earth wire and making good the disturbed surfaces to match with the existing surfaces complete all as specified and asd directed.
(a) One light point/Bell point controlled by one switch.
(b) One fan point controlled by one switch.
(c) One socket point controlled by one switch on same board.
(d) One socket point controlled by one switch on Independent board.
Description all as per item No 137 here in befor but with 1100 volts grade copper standard conductor cable of size 2.5 Sqmm with 2.5 Sqmm solid copper conductor PVC for 3 pin switch socket outlet15 Amp independent board complete all as specified and directed by Engineer in charge .
S & F in repair for bell ding dong AC 230 volts single pole one way complete all as specified and as directed.
S & F in repair for Switch piano flush type AC 230 volts 5 Amps single pole one way complete all as specified and as directed.
S & F in repair for Socket outlet 3 pin, 5 Amps and AC 230 volts flush type complete all as specified and as as directed.
S & F in repair for switch socket combination 3 pin 5 and 16 Amps AC 230 volts flush type complete all as specified and as directed.
S & F in repair for Ceiling rose surface bakelite 65 mm x50 mm three terminal AC 230 volts flush type complete all as specified and as directed.
S&F in repair fan regulator Step type of polycarbonate complete all as specified and as directed.
Supply and fixing in repair of LED lamp rotary type/holder type of 9 watt all as specified and as directed.
Supply and fixing in replacement of decorative wall light fitting WITH LAMPS 12 WATT made up of Polycarbonate , City-1 , Cylindrical shape , with LED lamp 9 Watt complete with fixing arrangements on wall complete all as specified and as directed.
Supply & Fixing Smart bright Batten Series, LED luminaire using LED 22 watt 110 Lumens/watt with diffuser which ensures uniform distribution and comfort, batten series features latest LEDs and delivers consistent light output, stable color start Extruded Aluminium housing, Energy efficient, Flicker free start Inbuilt driver unit, Suitable for wall and ceiling mounting using brackets with and including the luminaire testing on completion as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Secl), complete all as specified and as directed .
S & F in repair of LED Decorative /mirror light fitting 10watt along with fixture Surface mounted suitable for indoor aplication , connector block, etc . Complete with all accessories internally pre-wired and including round wood block, connecting up with three core flexible flexible copper conductor cable suitable size complete all as specified and as directed.
S&F in repair Bulk head endura LED light fitting complete with10 watt LED and making necessary electric connection to ceiling rose with copper conductor of suitable size & length complete all as specified and as directed.
Supply & fix in replacement of LED Security Light Luminaire 25 watt 6000K with .high power LED cool white,CRI 75,+/- 5% supply voltage 220/240/50 Hz, light engine driver base.pole adapter,powder coated pressure die cast aluminium with heat resistant toughened glass with lens type,GI pipe 40 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos of pole fitting clamps made out of MS flat , nuts and bolts and painting with aluminium paint. complete all as specified and as directed.
S & F in repair Sheet metal enclosure DBs Tripple Pole and Neutral 4- way with 200 Amps rated bus bar 415 volts single pole and neutral complete double door complete all as specified and as directed.
S & F in repair MCB TPN 415 volts 63 Amps, C Series complete all as specified and as directed.
Supply and fixing Single phase ceiling fan 1200 mm permanent magnet brushless DC Motor 230 v 50 Hz single phase 26-30watt rated current 0.16 amp,pf 0.98 370/360 rpm air delivery 220m3 rated service value 629m3/min/watt no of blades three type of blade leaf 1.05 mm thick aluminium sheet remote control radio frequency 5 speed +off timer option speed regulation class of insulation two nos bearings including connecting wire complete with all as required and directed at site.
S & F in repair Sheet metal enclosure DBs Single Pole and Neutral 8 way with 200 Amps rated bus bar 240 volts single pole and neutral complete double door complete all as specified and as directed.
Supply and fixing in replacement MCB single pole and neutral 240 volts 40 Amps, B Series complete all as specified and as directed.
Supply and fixing in replacement MCB/Isolators single pole 240 volts upto 40 Amps, B Series complete all as specified and as directed.
Supply & Fixing in repair modular AC box (earth plug socket) complete with 01 number single pole MCB 20 Amps complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
S & F in repair for bell push piano flush type AC 230 volts 5 Amps single pole one way complete all as specified and as directed.
Supply and fixing Single phase propeller type ventilating ( Exhaust fan) heavy duty AC 230 volts 300 mm sweep, metallic body complete with Metalic louvers including making holes of suitable size and making good the disturbed surface and shutters including electric connection with pvc flexible twin core copper wire from ceiling rose to Exhaust fan, nut & bolt complete all as specified and as directed.
Supply , laying and testing cable XLPE insulated , screened, PVC bedded , galvanized , steel strip or wire armoured, electric power cables ( Heavy duty ) 1100 volts grade with stranded aluminium conductor of size 4 core 25 Sqmm complete all as specified and as directed.
Supply and fixing Single phase propeller type ventilating ( Exhaust fan) heavy duty AC 230 volts 300 mm sweep, PVC body complete with Metalic louvers including making holes of suitable size and making good the disturbed surface and shutters including electric connection with pvc flexible twin core copper wire from ceiling rose to Exhaust fan, nut & bolt complete all as specified and as directed.
Supplying and fixing,testing the water heater storage type 25 litres, BEE Five star Rated capacity and after connecting electric and water connection and screwing nuts and bolts , anchor hold fast to fixed on wall and making the good the disturbed surface, complete all as required and as directed at site.
Supply,laying & fixing double wall corrugated (DWC) pipes of size 50 mm outer dia and 38 mm inner dia made of high density polythyline (HDPE) with all accessories i.e. all type of joints,Sockets,Elbows,bends and End caps etc.. complete all as specified and as directed.
.Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes,etc. n exc 10sqm on plan and getting out in any type of soil complete all as specified and as directed.
M/L for Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed.
M/L for Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.
charanjeet singh (BID ID -3165295)
M/S Modern builders (BID ID -3162632)
chandra builders (BID ID -3165069)
Tiki Water proofing Co (BID ID -3163799)
upadhyay Builders (BID ID -3165126)
SHRI KRISHNA CONSTRUCTIONS (BID ID -3165156)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .