| 1.00NOTE FOR DAY TO DAY COMPLAINT RECTIFICATION, SERVICE, MAINTENANCE AND REPAIR OF AIR CONDITIONER (SPLIT/WINDOW/WALK-IN-COOLER), WATER COOLER, REFRIGERATOR, DEEP FREEZER, AIR CURTAIN & DESERT COOLER. (a) Servicing, repair and replacement of parts and re-assembling after repair, installation, testing and commissioning etc shall be carried out through Well qualified AC & Refrigeration mechanic having minimum 05 year experience in their expertise. Contractor shall also render certificate of the same. (b) The Air Conditioner (Split/Window/Walk-In-Cooler), Water Cooler, Refrigerator, Deep Freezer, Air curtain & Desert Cooler etc shall be dismantled and opened in the presence of Engineer-in-Charge and an inventories of defective parts required to be replaced/works to be carried out shall be prepared and signed by Engineer-in-charge and contractor. Inventories shall be made carefully after thorough examination of serviceability of existing parts. Any parts essentially required other than considered in BOQ for smooth functioning shall be replaced by Contractor and rate for the same shall be deemed to include in rate quoted by Contractor. Inventories sheet should be in proper format showing machine no./MES No. & details of replace/repair spare parts and work as incorporated. (c) The parts being replaced shall be brand new and shall be same make & specification to match with the existing parts of Air Conditioner (Split/Window/Walk-In-Cooler), Water Cooler, Refrigerator, Deep Freezer, Air curtain & Desert Cooler etc . The required parts shall be procured by the contractor from the authorized dealer of OEM and contractor shall also produce the original purchase voucher and proof of its purchase from authorized dealer to Engineer-in-Charge before claiming the payment. (d) Repair works carried out in Air Conditioner (Split/Window/Walk-In-Cooler), Water Cooler, Refrigerator, Deep Freezer, Air curtain & Desert Cooler etc and their cost of repair will be entered in PRB duly given reference of CA No and name of work and counter signed by Engineer-in-Charge. (e) Pressure test with Nitrogen gas for 72 hours is inclusive of the quoted rate. (f) If required shifting of Water Cooler, Refrigerator, Deep Freezer, Air curtain & Desert Cooler etc shall be deemed to include in their quoted rate. (g) Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department. (h) AC & Refrigeration mechanic having minimum 05 year experience in their expertise along with well conversant Helper so detailed by the contractor will report to MES complaint cell at 08.45 Hrs morning to receive complaints(Complaint slip provided by the contractor) from department and complaint should be rectified with in a same day. In case non rectification of complaints on same day, an amount of Rs-600/- per day shall be recovered from contractor dues. (j) Transport/vehicle shall be arrange by the contractor to attending the complaints of Area-I & Area-II. Amount for the same shall deemed to be included in their quoted rate. | |||||
| 2.00 | AIR CONDITIONER (SPLIT/WINDOW/WALK-IN-COOLER)
Carry out day to day complaint rectification and periodical service maintenance as per manual recommendation at Area I & Area II like testing of gas leakage from line any Capacity, reapir/replacement of defective parts i.e. any capacity of Compressor, capacitor/Condensor, cooling coil, Swing motor and blade, over load relay, PVC grill, blower motor and fan blade, condensor motor with fan blade, thermostate, air filter, any size of Copper tube along with insulation pipe, drain out pipe, Cooling fan & cooling fan motor, PCB circuit board along with remote control, industrial metal plug top and bottom, Plug nut, Suction pipe, back plate, relay contactor, NRV, Charging Gas, Testing of gas leakeage using nitrazen gas, Cleaning of the Filters, checking control Wiring etc. complete all as specified and directed.
Note: (i) Spares parts and fitting shall be measured and paid separately as supply only in respective items given here-in-after.
(ii) If required Shifting of Split/Window AC shall be measured and paid separtely in respective items given here-in-after. | 50 | Each Job | 400 ₹20,000 Lowest | 650 ₹32,500 |
| 2.01 | Supply only fan motor for walk-in-cooler complete all as specified and directed. | 1 | Each | 3,500 ₹3,500 Lowest | 3,500 ₹3,500 Lowest |
| 2.02 | Supply only Compressor suitable for window/Split AC of capacity 1.5 Ton complete all as specified and directed. | 6 | Each | 10,000 ₹60,000 | 9,500 ₹57,000 Lowest |
| 2.03 | Supply only Compressor suitable for window/Split AC of capacity 2.0 Ton complete all as specified and directed. | 5 | Each | 12,200 ₹61,000 | 10,500 ₹52,500 Lowest |
| 2.04 | Supply only Compressor Suitable for Split AC of Capacity 3.0 Ton complete all as specified and directed. | 2 | Each | 14,000 ₹28,000 Lowest | 15,500 ₹31,000 |
| 2.05 | Supply only Capacitor of capacity 40/45 MFD complete all as specified and directed. | 5 | Each | 250 ₹1,250 Lowest | 250 ₹1,250 Lowest |
| 2.06 | Supply only Capacitor of capacity 50 MFD complete all as specified and directed. | 3 | Each | 300 ₹900 | 280 ₹840 Lowest |
| 2.07 | Supply only Capacitor of capacity 55/60 MFD complete all as specified and directed. | 3 | Each | 300 ₹900 Lowest | 350 ₹1,050 |
| 2.08 | Supply only Capacitor of capacity 65 MFD complete all as specified and directed. | 3 | Each | 320 ₹960 Lowest | 350 ₹1,050 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
21 Mar 2026, 6:00 pmClosed
GARRISON ENGINEER SAUGOR
Military Engineer services Garrison Engineer Saugor MP- 470001
REPAIR AND MAINT OF SUMMER APPLIANCE AND ALLIED WORKS UNDER GE SAUGOR
2026_MES_754908_1
GE/SGR/TOK-70 OF 2025-26
Open Tender
Miscellaneous Works
Item Rate
180 days
Saugor
Class E category c (i) and as per tender documents
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER SAGAR
₹30,000
Yes
14 May 2026
2 Mar 2026
23 Mar 2026
2 Mar 2026
21 Mar 2026
16 Mar 2026
2 Mar 2026 - 9 Mar 2026
AIR CONDITIONER (SPLIT/WINDOW/WALK-IN-COOLER) Carry out day to day complaint rectification and periodical service maintenance as per manual recommendation at Area I & Area II like testing of gas leakage from line any Capacity, reapir/replacement of defective parts i.e. any capacity of Compressor, capacitor/Condensor, cooling coil, Swing motor and blade, over load relay, PVC grill, blower motor and fan blade, condensor motor with fan blade, thermostate, air filter, any size of Copper tube along with insulation pipe, drain out pipe, Cooling fan & cooling fan motor, PCB circuit board along with remote control, industrial metal plug top and bottom, Plug nut, Suction pipe, back plate, relay contactor, NRV, Charging Gas, Testing of gas leakeage using nitrazen gas, Cleaning of the Filters, checking control Wiring etc. complete all as specified and directed. Note: (i) Spares parts and fitting shall be measured and paid separately as supply only in respective items given here-in-after. (ii) If required Shifting of Split/Window AC shall be measured and paid separtely in respective items given here-in-after.
Supply only fan motor for walk-in-cooler complete all as specified and directed.
Supply only Compressor suitable for window/Split AC of capacity 1.5 Ton complete all as specified and directed.
Supply only Compressor suitable for window/Split AC of capacity 2.0 Ton complete all as specified and directed.
Supply only Compressor Suitable for Split AC of Capacity 3.0 Ton complete all as specified and directed.
Supply only Capacitor of capacity 40/45 MFD complete all as specified and directed.
Supply only Capacitor of capacity 50 MFD complete all as specified and directed.
Supply only Capacitor of capacity 55/60 MFD complete all as specified and directed.
Supply only Capacitor of capacity 65 MFD complete all as specified and directed.
Supply only Capacitor of capacity 40/45+2.5 MFD complete all as specified and directed.
Supply only Capacitor of capacity 40/45+4MFD complete all as specified and directed.
Supply only Capacitor of capacity 40/45+6 MFD complete all as specified and directed.
Supply only Cooling Coil suitable for 1.5/2.0 Ton Capacity Window AC complete all as specified and directed.
Supply only Cooling Coil suitable for 1.5/2.0 Ton Capacity Split AC complete all as specified and directed.
Supply only Cooling Coil suitable for 3.0 Ton Capacity Split AC complete all as specified and directed.
Supply only Swing motor suitable for 1.5/2.0 Ton Capacity Window type Air Conditioner as per existing sample complete all as specified and directed.
Supply only Swing motor blades suitable for 1.5 Ton Capacity Split type Air Conditioner as per existing sample complete all as specified and directed.
Supply only Swing motor blades suitable for 2.0 Ton Capacity Split type Air Conditioner as per existing sample complete all as specified and directed.
Supply only Swing motor suitable for 3.0 Ton Capacity Split type Air Conditioner as per existing sample complete all as specified and directed.
Supply only Swing motor blades suitable for 3.0 Ton Capacity Split type Air Conditioner as per existing sample complete all as specified and directed.
Supply only Over load relay suitable for 1.5/2.0 Ton Split type AC complete all as specified and directed.
Supply only Over load relay suitable for 3.0 Ton Split type AC complete all as specified and directed.
Supply only PVC Front gril suitable for Window type AC of any Make suitable for 1.5/2.0Ton window AC complete all as specified and directed.
Supply only AC indoor blower motor fan suitable for 1.5/2.0 Ton Capacity Window type AC complete all as specified and directed.
Supply only AC indoor blower motor fan suitable for 1.5/2.0 Ton Capacity Split AC complete all as specified and directed.
Supply only AC indoor blower motor fan suitable for 3.0 Ton Capacity Split AC complete all as specified and directed.
Supply only Blower motor fan blade suitable for 1.5/2.0 Window type AC complete all as specified and directed.
Supply only Blower motor fan blade suitable for 1.5/2.0 Split type AC complete all as specified and directed.
Supply only Blower motor fan blade suitable for 3.0 Split type AC complete all as specified and directed.
Supply only Condenser motor with fan blade suitable for 1.5/2.0 Ton capacity Window type AC complete all as specified and directed.
Supply only Condenser motor with fan blade suitable for 1.5 Ton capacity Split type AC complete all as specified and directed.
Supply only Condenser motor with fan blade suitable for 2.0 Suitable for Split type AC complete all as specified and directed.
Supply only Condenser motor with fan blade suitable for 3.0 Suitable for Split type AC complete all as specified and directed.
Supply only Thermostat switch with knob suitable for AC of any capacity complete all as specified and directed.
Supply only Air Filter Suitable for 1.5/2.0/3.0 Ton Capacity Window/Split type Air conditioner complete all as specified and directed.
Supply only Capillary tube length as per existing size suitable for 1.5/2.0/3.0 Ton Capacity Air conditioner complete all as specified and directed.
Supply only PCB Circuit with remote control suitable for any make and capacity of 1.5/2.0 Ton Window type AC complete all as specified and directed.
Supply only PCB Circuit with remote control suitable for any make and Capacity of 1.5/2.0/3.0 split type capacity Air Conditioner complete all as specified and directed.
Supply only PCB Circuit with remote control suitable for any make and Capacity of 1.5/2.0 Split type capacity inverter type Air Conditioner complete all as specified and directed.
Supply only Metal top with bottom suitable for 16 Amps Capacity 1.5/2.0/3.0 Ton Capacity Air conditioner complete all as specified and directed.
Supply only Suction/Drain out pipe suitable for 1.5/2.0/3.0 ton capacity Suitable for Air conditioner as per sample complete all as specified and directed.
Supply only Insulation of size 1/4, 3/8 for Split AC complete as per existing sample complete all as specified and directed.
Supply only Insulation of size 1/2 5/8 for Split AC complete as per existing sample complete all as specified and directed.
Supply only Copper Tube of size 1/4/ 3/8 suitable for any type and any capacity Air conditioner as per existing sample complete all as specified and directed.
Supply only Copper Tube of size 1/2 /5/8 suitable for any type and any capacity Air conditioner complete all as specified and directed.
Supply only Plug nut of size 1/4 3/8 suitable for any type and any capacity Air conditioner complete all as specified and directed.
Supply only Plug nut of size 1/2 5/8 suitable for any type and any capacity Air conditioner complete all as specified and directed.
Supply only Power relay Contactor suitable for 1.5 Ton AC complete all as specified and directed.
Supply only Power relay Contactor suitable for 2.0 Ton AC complete all as specified and directed.
Supply only Power relay Contactor suitable for 3.0 Ton AC complete all as specified and directed.
Supply only Refrigerent Gas R-22 complete all as specified and directed.
Supply only Refrigerent Gas R-32 ( C) complete all as specified and directed.
Supply only Refrigerent Gas R-134(a)/R-600a complete all as specified and directed.
Supply only NRV Suitable for Any Capacity & any Make Air conditioner complete all as specified and directed.
Supply only Dry cell 1.5V suitable for Different type of remote as per sample complete all as specified and directed.
M&L for dismentlling of indoor and outdoor unit and disconnect the electric and gas connection ,cleaning the internal and portion of split AC indoor and outdoor unit checking serviceability transport to new location and fixing the indoor and outdoor unit connect gas and electric connection testing and commissioning complete all as specified and directed. Note:- (i) Quoted rate shall be deemed included outdoor stand, copper tube alongwith insulation,cable as per site requirement any size any length. (ii) Point wiring shall be measured and paid separtely in respective items given here-in-after.
WATER COOLER Carry out day to day complaint rectification of any Make, any capacity of Water Cooler complaints at Area I & Area II like testing of gas leakege from line any Capacity, repair/replacement of defective parts i.e. any capacity of Compressor, capacitor/Condensor, any size of Copper tube, drain out pipe, PVC pipe, Cooling fan & cooling fan motor and cooling coil ,Compressor, over load relay & protector, GI grill, thermostate, float valve, tap, industrial metal plug top and bottom, sheet metal enclosure with MCB, Suction pipe & air filter etc. complete all as specified and directed. Note: (i) Spares parts and fitting shall be measured and paid separately as supply only in respective items given here-in-after. (ii) Water cooler Stainless storage tank brazing/welding of damage/crack portion and making good condition shall be measured and paid separtely in respective items given here-in-after.
Supply only Compressor suitable for 60/120 Water cooler capacity complete all as specified and directed.
Supply only Compressor suitable for 40/80 Water cooler capacity complete all as specified and directed.
Supply only Compressor suitable for 150/150 Water cooler capacity complete all as specified and directed.
Supply only Compressor suitable for 40/40Water cooler capacity complete all as specified and directed.
Supply only Compressor suitable for 150/180 Water cooler capacity complete all as specified and directed.
Supply only Starting Capacitor suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity complete all as specified and directed.
Supply only Running Capacitor suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity complete all as specified and directed.
Supply only Starting relay current type suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity complete all as specified and directed.
Supply only Over load Protector suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity complete all as specified and directed.
Supply only Thermostat switch with knob suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity complete all as specified and directed.
Supply only PVC float valve assy alongwith ball with complete accessories for water cooler any capacity of size 15 mm dia complete all as specified and directed.
Supply only Self closing water tap 15 mm dia chromium plated inner/outer thread for water cooler 150/180,60/120 and 40/80 capacity as per sample complete all as specified and directed.
Supply only Air Filter Suitable for water cooler 150/180,60/120 and 40/80 capacity complete all as specified and directed.
Supply only Capillary tube of suitable length as per existing size for water cooler 150/180,60/120 and 40/80 capacity complete all as specified and directed.
Supply only PVC Drain out pipe as per sample complete all as specified and directed.
Supply only PVC Flexible extension pipe 15 mm dia complete all as specified and directed.
Supply only Cooling Coil suitable for 150/180,60/120 and 40/80 capacity Water Cooler complete all as specified and directed.
Supply only Cooling coil Motor suitable for 150/180,60/120 and 40/80 capacity Water Cooler complete all as specified and directed.
Supply only Cooling coil Motor fan blade suitable for 150/180,60/120 and 40/80 capacity Water Cooler complete all as specified and directed.
M&L for brazing/welding of damage/crack portion of water cooler Stainless storage tank and making good condition including replacement of Bolt,nut with washers and testing complete all as specified and directed.
REFRIGERATOR Carry out day to day complaints rectification of any Make, any capacity of Refrigerator complaints at Area I & Area II like testing of gas leakege from line any Capacity, repair/replacement of defective parts i.e. any capacity of compressor, door gasket, capacitor/Condensor, any size of Copper tube, condensor coil, evaporator coil, expansion valve, drain out pipe, Cooling fan & cooling fan motor and cooling coil, relay, Vegitable tray, PVC stand, Magnetic gasket, Freezer, PVC Plug top and bottom, thermostate & air filter etc., complete all as specified and directed. Note: Spares parts and fitting shall be measured and paid separately as supply only in respective items given here-in-after.
Supply only Compressor suitable for 195 to 210 Ltrs Capacity Refrigerator complete all as specified and directed.
Supply only Compressor suitable for 225 to 250 Ltrs Capacity Refrigerator complete all as specified and directed.
Supply only Compressor suitable for 260 to 310 Ltrs Capacity Refrigerator complete all as specified and directed.
Supply only Magnetic door gasket suitable for 165 to 200 ltrs capacity Refrigerator as per sample complete all as specified and directed.
Supply only Magnetic door gasket suitable for 286/320 Ltrs capacity Refigerator as per sample (Double Door) complete all as specified and directed.
Supply only Freezer suitable for 165 to 200 ltrs capacity Refrigerator complete all as specified and directed.
Supply only Freezer suitable for 286/310 Ltrs capacity Refigerator complete all as specified and directed.
Supply only Relay current type and over load protector suitable for compressor complete all as specified and directed.
Supply only Thermostat auto defrost type suitable for any make and any capacity Refrigerator complete all as specified and directed.
Supply only Air Filter suitable for for any make and any capacity Refrigerator complete all as specified and directed.
Supply only Capillary tube of suitable length as per existing size for refrigerator any make and any capacity complete all as specified and directed.
Supply only Condensor Coil suitable for any model and capacity Refrigerator as per sample complete all as specified and directed.
Supply only Evaporator Coil suitable for any model and capacity Refrigerator as per sample complete all as specified and directed.
Supply only Expansion valve suitable for any model and capacity Refrigerator as per sample complete all as specified and directed.
DEEP FREEZER Carry out day to day complaint rectification of any Make,any capacity of Deep Freezer complaints at Area I & Area II like testing of gas leakege from line any Capacity, reapir/replacement of defective parts i.e. any capacity of Compressor, relay, thermostate, dry filter, indication lamp, capacitor/Condensor, any size of Copper tube , drain out pipe, Cooling fan & cooling fan motor and cooling coil, over load relay, Magnetic gasket, PVC Plug top and bottom, Door Lock, MS Hings, Trolley Nylon roller alingwith bracket etc complete all as specified and directed. Note: Spares parts and fitting shall be measured and paid separately as supply only in respective items given here-in-after.
Supply only Compressor Suitable for 300 Ltrs Capacity Deep Freezer complete all as specified and directed.
Supply only Compressor Suitable for 500 Ltrs Capacity Deep Freezer complete all as specified and directed.
Supply only Relay current type and over load protector suitable for compressor complete all as specified and directed.
Supply only Thermostat auto defrost type suitable for any make and any capacity Deep Freezer complete all as specified and directed.
Supply only Drier filter complete set suitable for any make and any capacity Deep Freezer complete all as specified and directed.
Supply only Indicating lamp (Red and Green) 230V complete suitable for any make and any capacity Deep Freezer as per sample complete all as specified and directed.
Supply only Capillary tube of suitable length as per existing size for Deep freezer any make and any capacity complete all as specified and directed.
Supply only Starting relay suitable for 310/320 ltrs capacity Deep freezer complete all as specified and directed.
Supply only Condenser motor (Rotary fan) suitable for any type and any capacity deep freezer complete all as specified and directed.
Supply only Starting capacitor suitable for Deep freezer suitable for any type and any capacity deep freezer complete all as specified and directed.
Supply only Fan motor of capacity 1/6 HP (125 W), 230 V, 50 Hz, SP, AC supply confirming to IS-996/79 (motor only) with mounting accessories complete all as specified and directed.
Supply only Water circulating submesible pump, 1300 RPM, SP, 230V, 50Hz 1.5M head , discharge 7.0 Ltrs/hr complete all as specified and directed.
Supply only Filter pad made out of wooden wool suitalbe for Air grills of desert cooler as per existing size complete all as specified and directed.
Supply only PVC Flexible hose suitable for desert cooler cooling system complete all as specified and directed.
Supply only PVC Fan Blade suitable for 3000/4000/5000/6000 as per sample complete all as specified and directed.
Supply only PVC Connector i.e (Elbow, Tee,4 way etc) complete all as specified and directed.
Supply only Switch 5 Amps complete all as specified and directed.
Supply only Indication lamp complete all as specified and directed.
Supply only Front Panel as per existing size and model complete all as specified and directed.
Supply only PVC switch box as per sample and size complete all as specified and directed.
Supply only GI Chicken Mesh complete all as specified and directed.
Supply only PVC Insulated copper conductor and PVC over all coverd cord cable copper conductor 3 core of size 2.5 Sqmm complete all as specified and directed.
M&L Sub main wiring with 2.5 Sqmm (nominal area), PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 2x2.5Sqmm (main current) and 1x2.5 Sqmm (earth wire) PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light point controlled by one ,one way switches including taking down complete all as specified and as directed Note: (i) cutting of walls (brick or stone), making good disturbed surface of wall in CM 1:3 and painting with existing colour & specifications is deemed to include in the quoted rate. (ii) Two runs of single core for main current and one run of single core for earth continuity conductor & one run of PVC casing -n-caping/pvc conduit shall be measured as one unit length.
Carry out day to day complaints rectification of any Make,any capacity of Air Curtains Complaints at Area I & Area II like testing of Air Curtain any Capacity, servicing & replacement of defective parts as required at site complete all as specified and directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
BOQ_845512.xls
BOQ • 0.41 MB
PS_TOK70.pdf
Additional Documents • 0.34 MB
GP_SC_TOK70.pdf
Tender Documents • 0.88 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .