Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.6 LAccepted-AOC | ₹36.6 L Quoted ₹37.2 L | L1 | Accepted-AOC L1 |
| 2 | L2₹38.1 L+₹94,140 (2.53%)Rejected-Finance | ₹38.1 L+₹94,140 (2.53%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹38.5 L+₹1.3 L (3.42%)Rejected-Finance A 103 VEERA GARDEN AMBEDKAR NAGAR ALWAR 301001 RAJ | ALWAR | RAJASTHAN | 301001 | ₹38.5 L+₹1.3 L (3.42%) | L3 | Rejected-Finance Being L3 |
| 4 | L4₹40.9 L+₹3.7 L (10.0%)Rejected-Finance | ₹40.9 L+₹3.7 L (10.0%) | L4 | Rejected-Finance Being L4 |
| 5 | L5₹41.8 L+₹4.6 L (12.5%)Rejected-Finance PLOT NO 14 SHIV COLONY KATI GHATI RAJGARH ROAD ALWER RAJ | ALWAR | ALWAR | RAJASTHAN | ₹41.8 L+₹4.6 L (12.5%) | L5 | Rejected-Finance Being L5 |
Tender Value
Refer Docs
EMD Value
₹76,800
Closing Date
7 Feb 2023, 6:00 pmClosed
GE Alwar
GE Alwar
SPECIAL REPAIR TO CONVERSION OF LT OH LINE TO LT UG CABLE AND CONNECTED SERVICE UNDER AGE E/M AT ITARANA, ALWAR
2023_MES_574820_1
8127/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Alwar
As per NIT
3 documents required · 3 mandatory
₹500
Yes
GE Alwar
₹76,800
Yes
1 Mar 2023
13 Jan 2023
9 Feb 2023
13 Jan 2023
7 Feb 2023
28 Jan 2023
13 Jan 2023 - 27 Jan 2023
Amount
Taking down old unserserviceable ACSR Conductor and GI wire of any size from LT Poles and removing from site complete all as specified and directed.
Taking down old unserserviceable GI earth wire/guard wire etc of any size from LT Poles and removing from site complete all as specified and directed.
Dismantling and taking down of old unserviceable pin type/ shackle type insulators and from any height of electric pole complete all as specified and directed.
Taking down old unserviceable cross -arms/clamps/nut bolts and Angle section etc from LT Pole any size, complete all as specified and directed.
Dismantling and taking down old unserserviceable stay assembly from LT Poles and removing from site complete all as directed.
Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for in this Schedule complete all as specified.
M&L PCC (1:3:6) type C1 using 20 mm graded crushed stone aggregate as in coping/pedestal of poles including providing necessary form work for fair finished exposed concrete surfaces complete all as specified and as directed.
Supply, lay, jointing and testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 Sqmm 3.5 Core cable laid in trenches/pasing through pipe under road crossing etc all as specified and directed. Make : Havell's / Polycab / Grandlay / Finolex
All as per item No 8.00 but size 95 Sqmm 3.5 Core.
All as per item No 8.00 but size 50 Sqmm 3.5 Core.
All as per item No 8.00 but size 25 Sqmm 4 Core.
All as per item No 8.00 but size 16 Sqmm 4 Core.
All as per item No 8.00 but size 25 Sqmm 2 Core.
All as per item No 8.00 but size 16 Sqmm 2 Core.
Excavation in trenches n. exc 1.5Mtr width n.exc 1.5 Mtr in depth for laying of cables & foundation of poles, stay assembly and getting out soft/loose soil.
M&L sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover complete all as specified and directed. Note :- Thickness after punning shall be considered for payment.
M&L brick work with FLY ASH BRICKS(As Per IS-13757(1993) burnt clay fly ash building bricks), (OLD SIZE BRICKS) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection and complete all as specified & directed.
M&L for returning, filling in including spreading levelling , watering and well ramming in layers not exc. 25 cm in any type soil.
M&L for removing of surplus excavated soil to a distance not exc. 50m and depositing where directed at a levelnot exc 1.5 Mtr above the starting point.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 80mm dia suitable for 0.4 mpa working pressure.
M&L galvanized iron tubing, 50 mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable including taking down old unserviceable GI tube complete. Make : Jindal/Prakash/TATA
M&L galvanized iron tubing, 50 mm bore medium grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable including taking down old unserviceable GI tube complete. Make : Jindal/Prakash/TATA
Supply and errecting Cable path indicators for LT Cable made of CI plate fixed on MS angle iron size 25x25x5mm and 60 Cm long. and fixing in ground 30 Cm below ground level in PCC 1:3:6 type B-1 using 40mm grade stone aggregate of size 30x30x30cm . Cable path indicators shall be provided at distance of every 30 meters and at cable joints and turning of all cables and incorporated LT 1100 Volts on it. including PCC & earth work complete all as specified and directed.
Supply, installing, testing and commissioning factory made, floor mounted outdoor type LT panel board, cubicle type of size 85 x 75 x 45cm, suitable for 415 Volts, 3 Phase, 4 wire, 50 Hz, AC supply system, and tested at CPRI, having bus bar chamber with insulated Aluminium bus bar four wire system, colour coded for each phase and neutral, insulated on epoxy type insulators. The bottom of the outer shell contains a detachable plate having provn for entry of cable of adequate size with glands, The panel shall be dust and vermin proof, IP-65 class protection and made 3.2 mm CRCA MS sheet, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm) including grouting of panel 45 cm above ground level by providing 90 cm long angle iron frame of size 50x50x6 mm, welded on all the four corners, embedded in pcc 1:2:4 using 20 mm stone aggregate upto 30 cm above ground level complete all as specified and directed including the following accessories:- Make : Universal/C&S/Indo Asian/ Power Tech. INCOMING (ii) Aluminium bus bar 200 Amps with insulator-04 Nos (v) Instrument control fuses and indication lamp (RYB) – one set OUTGOING (i) Thermal magnetic MCCB 3 pole,125 Amps 25 KA -01 Nos (iii) MCB TP, 63 Amps 10 KA, 'C' Curve -02 Nos + (Space for one No MCB)
All as per Item No 24.00 but the following accessories:- INCOMING (i) Aluminium bus bar 200 Amps with insulator-04 Nos (ii) Instrument control fuses and indication lamp(RYB) – one set OUTGOING (i) Thermal magnetic MCCB 3 pole,100 Amps 25 KA -01 No (ii) MCB TP, 63 Amps 10 KA, 'C' Curve -01 Nos + (Space for one No MCB)
All as per Item No 24.00 but the following accessories:- INCOMING (i) Aluminium bus bar 200 Amps with insulator-04 Nos (ii) Instrument control fuses and indication lamp(RYB) – one set OUTGOING (i) Thermal magnetic MCCB 3 pole,63 Amps 25 KA -01 No (ii) MCB TP, 63 Amps 10 KA, 'C' Curve -02 Nos + (Space for one No MCB)
All as per Item No 24.00 but the following accessories:- INCOMING (i) Aluminium bus bar 200 Amps with insulator-04 Nos (ii) Instrument control fuses and indication lamp(RYB) – one set OUTGOING (i) MCB TP, 63 Amps 10 KA, 'C' Curve -03 Nos + (Space for one No MCB)
All as per Item No 23 but the following accessories:- INCOMING (i) Aluminium bus bar 200 Amps with insulator-04 Nos (ii) Instrument control fuses and indication lamp(RYB) – one set OUTGOING (i) Thermal magnetic MCCB 3 pole,100 Amps 25 KA -01 No (ii) MCB TP, 63 Amps 10 KA, 'C' Curve -03 Nos + (Space for one No MCB)
All as per Item No 24.00 but the following accessories:- INCOMING (i) Aluminium bus bar 200 Amps with insulator-04 Nos (ii) Instrument control fuses and indication lamp(RYB) – one set OUTGOING (i) Thermal magnetic MCCB 3 pole,63 Amps 25 KA -02 Nos (ii) MCB TP, 63 Amps 10 KA, 'C' Curve -02 Nos + (Space for one No MCB)
S&F pole mounted juction box made out of one piece moulded SMC IP65 protection having aluminium bus bars 100 Amp three phase and neutral with one No MCB SPN 6 Amp for street light, cable entry from bottom, maintenance free size 300x200x 100 mm fixing on pole with two Nos MS flat 25x3mm clamp including nut bolts front openable all as specified and directed. Make : Finolex/ Universal/ Sintex/ Legrand.
S&F pole mounted juction box made out of one piece moulded SMC IP65 protection having aluminium bus bars 100 Amp single phase and neutral with one No MCB SPN 6 Amp for street light, cable entry from bottom, maintenance free size 300x200x100 mm fixing on pole with two Nos MS flat 25x3mm clamp including nut bolts front openable all as specified and directed. Make : Finolex/ Universal/ Sintex/ Legrand.
S&F PVC insulated and round sheathed copper conductor cable 2.5 sqmm 3 core through and including steel conduit from street light fitting to junction box and making necessary connection both at junction box and street light fittings and fixing accessories complete all as directed. Make : Havells / Finolex / Gloster / Polycab
M&L earthing complete as per electric plate No 3 of MES SSR Part-I with galvanised steel earth plate electrode 60x60cmx6.3mm thick burried directly in ground ( earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised strip 25 x 4 mm earth lead by means of bolts, nuts, check nuts and wathers of GI or steel. Earthing strip shall be protected by galvanised iron pipe 40 mm bore light grade and connected to continous earth lead on pole/test point, Watering pipe shall be 20 mm bore GI medium grade. The unit rate quoted for earthing shall be inclusive of excavation and earth work in any type of soil, charcoal, salt, funnel, PCC pit and RCC cover complete all as specified and directed.
M/S GAURI CONSTRUCTION
Hitesh Construction
M/s S Amarjit Singh
M/s Yash Electrical and Maintenance
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .