Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical due to proper document not uploaded |
Tender Value
Refer Docs
EMD Value
₹28,100
Closing Date
2 Jul 2024, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EUDC-III GHAZIABAD
SE EUDC-III GANDHI NAGAR GZB
Work of Installation new Transformers at various site Under Business Plan Scheme 2024-25 in the Area of EUDD-IV and EUDD-VII Ghaziabad. under the jurisdiction of EUDC-III, Ghaziabad.
2024_PVVNL_922455_2
84/W/2023-24/EUDC-III GZB
Open Tender
Electrical Works
Item Rate
90 days
SE EUDC-III GANDHI NAGAR GZB
Please Refer Tender documents
2 documents required · 2 mandatory
₹3,540
Superintending Engineer EUDC-III GZB
₹28,100
3 Jul 2024
6 Jun 2024
2 Jul 2024
6 Jun 2024
2 Jul 2024
6 Jun 2024
Amount
Carriage of LT PVC/XLPE Cable AL. 1x240 sqmm from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of LT XLPE cable 3.5x70 sqmm from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of LT PVC/XLPE cable 3.5x150 sqmm from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of LT XLPE cable 3.5x240 sqmm from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of LT XLPE Cable AL. 1x120 sqmm from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of LT ABC Cable (1x16+1x25) sqmm. from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of LT AB Cable 3x120+1x95+1x16 sqmm. from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of LT AB Cable 3x95+1x70+1x16 sqmm. from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 11/0.4 kv 250 kva New Transformer from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 100 kva New Transformer from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of 25 kva New Transformer from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of ST Pole 11 Mtr SP-55 from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of PCC Pole 8.5 Mtr from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of ACSR Weasal Conductor from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of ACSR Dog Conductor from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of ACSR Rabit Conductor from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Carriage of line material as:- 3 Phase Distribution Box- 39 Nos, 1 Phase Distribution Box- 12 Nos, Top Channel 100x50x2240 MM- 481 Kg, M.S Top Channel 125x65x2240 MM- 7 Nos, Dropper Channel 125x50x2000 MM- 960 Kg, M.S Channel 100x50 mm- 576 Kg, M.S Channel 125x65x1300 mm T-off- 17 Nos, M.S Angle 65x65x6 mm- 350 Kg, 11 kv Disc Insulator 45 KN with Fitting- 78 Nos, 11 kv Polymeric Disc Insulator- 57 Nos, 11 kv Polymeric Pin Insulator- 268 Nos, Earthing Rod complet- 48 Nos, Stay Set Complete- 11 Nos, 11 kv TPMO with Polymeric Insulator- 20 Nos, 11 kv V-type Cross Arm- 12 Nos, 3 Phase D.O/11 kv Fuse Set- 30 Nos, MS T-Off Channel-24 Nos from Store center to various work site loading and unloading both side. distance 1 km to 50 km.
Erection of ST pole 11 Mtr long at various site complete in all respect as per RESPO norms.
Erection of PCC pole 8.5 Mtr long at various site complete in all respect as per RESPO norms.
Providing & Grouting/Concreating of ST Pole/PCC Pole complete in all respect as per RESPO norms.
Laying of LT PVC/XLPE Cable AL. 1x240 sqmm at various site complete in all respect as per RESPO norms.
Laying of LT XLPE cable 3.5x70 sqmm at various site complete in all respect as per RESPO norms.
Laying of LT PVC/XLPE cable 3.5x150 sqmm at various site complete in all respect as per RESPO norms.
Providing & laying, fixing of HDPE Pipe 6" Dia for Cable Laying complete in all respect as per RESPO norms.
Laying, of LT XLPE cable 3.5x240 sqmm with tranchless method complete in all respect as per RESPO norms.
Fixing of LT XLPE cable 3.5x240 sqmm at various site complete in all respect as per RESPO norms.
Laying of LT XLPE Cable AL. 1x120 sqmm at various site complete in all respect as per RESPO norms.
Laying, Lifting and sagging of LT ABC Cable (1x16+1x25) sqmm. at various site complete in all respect as per RESPO norms.
Laying, Lifting and sagging of LT AB Cable 3x120+1x95+1x16 sqmm. at various site complete in all respect as per RESPO norms.
Laying, Lifting and sagging of LT AB Cable 3x95+1x70+1x16 sqmm. at various site complete in all respect as per RESPO norms.
Laying, Lifting and sagging of ACSR Weasel conductor at various site complete in all respect as per RESPO norms.
Laying, Lifting and sagging of ACSR Dog conductor at various site complete in all respect as per RESPO norms.
Laying, Lifting and sagging of ACSR Rabit conductor at various site complete in all respect as per RESPO norms.
Providing and construction of plinth for 250 kva Transformer with Material at various site complete in all respect as per RESPO norms.
Mounting & Safely placing of 250 kva new Transformer on the plinth by the help of Crane/Chain Cuppie etc. complete in all respect as per Respo Norms at various site.
Mounting & Safely placing of 100 kva new Transformer on Double Pole by the help of Crane/Chain Cuppie etc. complete in all respect as per Respo Norms at various site.
Mounting & Safely placing of 25 kva new Transformer on Double Pole by the help of Crane/Chain Cuppie etc. complete in all respect as per Respo Norms at various site.
Providing and fabrication & fixing of Fancing of Transformer Plinth at various site complete in all respect as per RESPO norms.
Providing and Chemical Earthing of Transformer at various site complete in all respect as per RESPO norms.
Fixing of 3 Phase Distribution Box at various site complete in all respect as per RESPO norms.
Fixing of 1 Phase Distribution Box at various site complete in all respect as per RESPO norms.
Fixing of Top Channel 100x50x2240 MM at various site complete in all respect as per RESPO norms.
Fixing of M.S Top Channel 125x65x2240 MM at various site complete in all respect as per RESPO norms.
Fixing of Dropper Channel 125x50x2000 MM at various site complete in all respect as per RESPO norms.
Fixing of M.S Channel 100x50 mm at various site complete in all respect as per RESPO norms.
Fixing of M.S Channel 125x65x1300 mm T-off at various site complete in all respect as per RESPO norms.
Fixing of M.S Angle 65x65x6 mm at various site complete in all respect as per RESPO norms.
Fixing of 11 kv Disc Insulator 45 KN with Fitting at various site complete in all respect as per RESPO norms.
Fixing of 11 kv Polymeric Disc Insulator at various site complete in all respect as per RESPO norms.
Fixing of 11 kv Polymeric Pin Insulator at various site complete in all respect as per RESPO norms.
Fixing of Earthing Rod complet at various site complete in all respect as per RESPO norms.
Fixing of Stay Set Complete at various site complete in all respect as per RESPO norms.
Fixing of 11 kv TPMO with Polymeric Insulator at various site complete in all respect as per RESPO norms.
Fixing of 11 kv V-type Cross Arm at various site complete in all respect as per RESPO norms.
Fixing of 3 Phase D.O/11 kv Fuse Set at various site complete in all respect as per RESPO norms.
Fixing of MS T-Off Channel at various site complete in all respect as per RESPO norms.
Providing & fixing of Dead end Clamp at various site complete in all respect as per RESPO norms.
Providing & fixing of I Hook at various site complete in all respect as per RESPO norms.
Providing & fixing of AL. Lug 150 at various site complete in all respect as per RESPO norms.
Providing & fixing of Nut & Bolt Off Size at various site complete in all respect as per RESPO norms.
Providing & fixing of Piercing Connector at various site complete in all respect as per RESPO norms.
Providing & fixing of Aluminium Busbar at various site complete in all respect as per RESPO norms.
Providing & fixing of J Hook at various site complete in all respect as per RESPO norms.
Providing & fixing of J Hook clamp with Nut and Bolt at various site complete in all respect as per RESPO norms.
Providing & fixing of Clamp for LT (T-off) with Nut & Bolt at various site complete in all respect as per RESPO norms.
Providing & fixing of Stone Pad at various site complete in all respect as per RESPO norms.
Providing & fixing of Suspension clamp at various site complete in all respect as per RESPO norms.
Providing & fixing of M.S Holding clamp with Nut & Bolt at various site complete in all respect as per RESPO norms.
Providing & fixing of Clamp with Nut & Bolt at various site complete in all respect as per RESPO norms.
Making of all HT/LT connections required to energize the line and restoring of electricity supply to consumer properly complete in all respect.
m/s panwar contaruction co. shamli
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .