| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.5 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹8.8 L+₹7,632 (0.87%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹10.1 L+₹1.4 L (15.6%)Rejected-Finance 184 TENGPUNA PULWAMA PULWAMA PULWAMA JAMMU KASHMIR 192301 UDYAM JK 15 0009999 | PULWAMA | JAMMU AND KASHMIR | 192301 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹10.6 L+₹1.8 L (21.0%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹10.6 L+₹1.9 L (21.8%)Rejected-Finance AZAD COLONY B 90 FEET ROAD SOURA SRINAGAR J K 190011 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190011 | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹13.6 L
EMD Value
₹27,120
Closing Date
4 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) AWANTIPUR
GE (AF) AWANTIPUR, 8 FBSU, AF AWANTIPUR
REPAIR/ MAINT OF DG SETS/ LT VOLTAGE STABILIZER AND EARTHING SYSTEM AT E/M INSTALLATION AT 8FBSU
2021_MES_473118_1
GE(AF) AWA-22/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) AWANTIPUR
AS PER NIT AND TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE (AF) AWANTIPUR
₹27,120
Yes
30 Oct 2021
6 Sept 2021
12 Oct 2021
6 Sept 2021
4 Oct 2021
21 Sept 2021
60 days
Amount
M&L for welding of broken Acousting Enclosure Gate of DG Sets of any capacity by providing proper hinge and locking arrangement as per existing size and type for fixing in position, complete all as specified and directed.
Carrying out top over hauling of DG set 125 KVA including opening of upper portion of diesel engine including taking out heads, pistons, water sleeve, inlet and exhaust valve to facilate the repair work, adjustment of tappet of engine with the help of filler gauge for proper movement of valves. Assembling of engine after carrying out overhauling work and testing the same for its fixing, prevention of any leakage and testing the same, complete all as specified and directed.
Carrying out top over hauling of DG set 400 KVA including opening of upper portion of diesel engine including taking out heads, pistons, water sleeve, inlet and exhaust valve to facilate the repair work, adjustment of tappet of engine with the help of filler gauge for proper movement of valves. Assembling of engine after carrying out overhauling work and testing the same for its fixing, prevention of any leakage and testing the same, complete all as specified and directed.
M&L for following parts to be fixed under above item for DG set of capacity 125/160/200 KVA, Make: Kirloskar/Cummins:- (a) Fuel filter primary.
(b) Fuel filter secondary
(c) Lub oil filter
(d) Air cleaner filter
(e) Hose pipe set with clamps
(f) Flexible pipe with end connector
(g) Fan belt for charging alternator
(h) Fan belt for radiator
(i) Stop solenoid actuator
M & L for head decarbonising, grinding of valve seat, lapping of inlet and outlet valves refixing the same after replacement of rubber rings of 125 KVA DG Set, complete all as specified and directed.
M & L for piston ringset of 125 KVA DG Set after decarbonising the piston grooves for proper control of oil flow, complete all as specified and directed.
M & L for water sleeve assembly of 125 KVA DG including cleaning and smoothing of bore of engine top block and testing the same for free movement of piston in the sleeve, complete all as specified and directed.
M & L for water pump assembly of 125 KVA DG Set.
M & L for thermostat switch of 125 KVA DG
M & L for turbocharger repair kit of 125 KVA DG.
M & for exhaust manifold of 125 KVA DG connecting the same with exhaust pipe.
M & L for fly wheel ring of 125 KVA DG.
M & L for head gasket set of 125 KVA DG Set
Dismantling of FIP from engine of capacity 125 KVA after disconnecting pressure pipes, cleaning assembly and testing for proper injection of fuel. Replacement of delivery valve, plunger, plunger spring, regulating sleeve, tappet assembly, assembly element and delivery valve assembling the FIP and testing of FIP, complete all as specified and directed.
Taking out injectors assemblies of 125 KVA DG set, 6 cylinder ( complete injector assemblies) testing the same in authorised workshop for proper injection of POL including caliberation of nozzles and replacment of nozzles if required, complete all as specified and directed.
M & L for replacemnt of inlet valve seat for 125 KVA DG set, complete all as specified and directed.
M & L for replacemnt of outlet valve seat for 125 KVA DG set, complete all as specified and directed.
M & L for dismantling alternator of 125 KVA DG set taking out the rotor assembly cleaning the rotor assembly, varnishing the stator winding & field coil winding with red varnish spray of F class insulation, inserting insulating material in stator winding greasing of end bearing of rotor including making of electrical connection of field coils. Assembling of complete alternator and testing of alternator, complete all as specified and directed.
M & L for head decarbonising, grinding of valve seat, lapping of inlet and outlet valves refixing the same after replacement of rubber rings of 400 KVA DG Set.
M & L for piston ringset of 400 KVA DG Set after decarboising the piston grooves for proper control of oil flow complete all as specified and directed.
M & L for water sleeve assembly of 400 KVA DG including cleaning and smoothing of bore of engine top block and testing the same for free movement of piston in the sleeve complete all as specified and directed.
M & L for water pump assembly of 400 KVA DG Set.
M & L for thermostat switch of 400 KVA DG
M & L for turbocharger repair kit of 400 KVA DG.
M & for exhaust manifold of 400 KVA DG connecting the same with exhaust pipe.
M & L for fly wheel ring of 400 KVA DG.
M & L for head gasket set of 400 KVA DG Set
Dismantling of FIP from engine of capacity 400 KVA after disconnecting pressure pipes, cleaning assembly and testing for proper injection of fuel. Replacement of delivery valve, plunger, plunger spring, regulating sleeve, tappet assembly, assembly element and delievery valve assembling the FIP and testing of FIP all as specified and directed.
Taking out injectors assemblies of 400 KVA DG set, 8 cylinder ( complete injector assemblies) testing the same in authorised workshop for proper injection of POL including caliberation of nozzles and replacment of nozzles if required complete all as specified and directed.
M & L for replacement of inlet valve seat for 400 KVA DG set complete all as specified and directed by Engr-in-charge.
M & L for replacement of outlet valve seat for 400 KVA DG set complete all as specified and directed.
M & L for dismantling alternator of 400 KVA DG set taking out the rotor assembly cleaning the rotor assembly, varnishing the stator winding & field coil winding with red varnish spray of F class insulation, inserting insulating materail in stator winding greasing of end bearing of rotor including making of electrical connection of field coils. Assembling of complete alternator and testing of alternator all as specified and directed.
S&F in replacement of self starter 12 volts DC suitable for 75 to 125 KVA DG set, Make: Kirloskar complete including dismantling of existing and fixing the new fixing in position, making proper alignment complete all as specified and directed.
S&F in replacement of self starter 24 volts DC suitable for 160 to 320 KVA DG set, Make: Kirloskar complete including dismantling of existing and fixing the new fixing in position, making proper alignment complete all as specified and directed.
Carrying out servicing of DG set of capacity 100 KVA, Make: Kirloskar/Cummins in all respect like checking of diesel engine, multi cylinder and all safety devices, control panel by service engineer / service technician of any reputed service center / auth service center of OEM, and replacement of unserviceable spare parts/accessories including calibration of control devices/ refitting of serviceable parts after cleaning/servicing, cleaning of oil sump and replacement & including minor accessories including draining of oil, sludge/ dust from foundation/base plate complete all as specified and directed. (Note:- All defective parts shall be paid & measured separately).
M&L for following parts to be fixed under above item for DG set of capacity 100 KVA, Make: Kirloskar/Cummins:- (a) Fuel filter primary.
(b) Fuel filter secondary
(c) Lub oil filter
(d) Air cleaner filter
(e) Hose pipe set with clamp
(f) Flexible pipe with end connector
(g) Fan belt for charging alternator
(h) Fan belt for radiator
(i) Stop solenoid actuator
Carrying out servicing of DG set of capacity 62.5/63/75 KVA, Make: Kirloskar/Cummins in all respect like checking of diesel engine, multi cylinder and all safety devices, control panel by service engineer / service technician of any reputed service center / auth service center of OEM, and replacement of unserviceable spare parts/accessories including calibration of control devices/ refitting of serviceable parts after cleaning/servicing, cleaning of oil sump and replacement & including minor accessories including draining of oil, sludge/dust from foundation/base plate complete all as specified and directed. (Note:- All defective parts shall be paid & measured separately ).
M&L for following parts to be fixed under above item for DG set of capacity 62.5/63/75 KVA, Make: Kirloskar/Cummins:- (a) Fuel filter primary.
(b) Fuel filter secondary.
(c) Lub oil filter
(d) Air cleaner filter
(e) Hose pipe set with clamp
(f) Flexible pipe with end connector
(g) Fan belt for charging alternator
(h) Fan belt for radiator
Carrying out servicing of DG set of capacity 40/35/30/25/10 KVA, Make: Kirloskar/Cummins in all respect like checking of diesel engine, multi cylinder and all safety devices, control panel by service engineer / service technician of any reputed service center / auth service center of OEM,and replacement of unserviceable spare parts/accessories including calibration of control devices/ refitting of serviceable parts after cleaning/servicing, cleaning of oil sump and replacement & including minor accessories including draining of oil sludge/dust from foundation/base plate complete all as specified and directed. (Note:- All defective parts shall be paid & measured separately .
M&L for following parts to be fixed under above item for DG set of capacity 40/35/25/10 KVA, Make: Kirloskar/Cummins:- (a) Fuel filter primary.
(b) Fuel filter secondary.
(c) Lub oil filter
(d) Air cleaner filter
(e) Hose pipe set with clamp
(f) Flexible pipe with end connector
(g) Fan belt for charging alternator
(h) Fan belt for radiator
Carrying out servicing of DG set of capacity 320/400 KVA, Make: Kirloskar/Cummins in all respect like checking of diesel engine, multi cylinder and all safety devices, control panel by service engineer / service technician of any reputed service center / auth service center of OEM,and replacement of unserviceable spare parts/accessories including calibration of control devices/ refitting of serviceable parts after cleaning/servicing, cleaning of oil sump and replacement & including minor accessories including draining of oil dust from foundation/base plate complete all as specified and directed. (Note:- All defective parts shall be paid & measured separately ).
M&L for following parts to be fixed under above item for DG set of capacity 200/160/125 KVA, Make: Kirloskar/Cummins:- (a) Fuel filter primary.
(b) Fuel filter secondary.
(c) Lub oil filter
(d) Air cleaner filter
(e) Hose pipe set with clamp
(f) Flexible pipe with end connector
(g) Fan belt for charging alternator
(h) Fan belt for radiator
Servicing, checking and carry out calibration of relays/timers and contactors of AMF Panel/Control Panel of 63/75 KVA DG set including other connected electrical / electronic accessories including necessary wiring and testing complete including fixing only parts/refitting of serviceable parts after cleaning/servicing complete all as specified and directed. (Note:- All defective parts shall be paid & measured separately ).
M&L for following items for AMF/Control Panel of 63/75 KVA DG set to be fixed under above item:- (a) Starting time delay relay.
(b) Engine stop time delay relay
(c) Overload relay
(d) Under voltage relay
M&L for dismantling /opening of alternator by disconnection of cable connections and flexible coupling, nuts/bolts and alternator foundation nut, bolts including strip opening of alternator and checking out burnt out parts of DG Sets of capacity 320 KVA to 400 KVA all as specififed and directed.
All as per item No 45 above but of capacity upto 100 KVA.
Taking out burnt armature, winding wire and rewinding the armature with super enamelled copper winding wire of existing gauge of DG Sets of capacity upto 400 KVA all as specified and directed.
Taking out burnt field coil and rewinding the field coil with super enamelled copper winding wire of existing gauge of DG Sets of capacity upto 400 KVA DG all as specififed and directed.
M&L for insulation of armature with Class ‘B’ insulation and Varnishing of armature winding and drying up to desired temperature of DG Sets of capacity upto 100 KVA all as specififed and directed.
All as per Ser item No 49 here-in- before but of capacity 320 KVA to 400 KVA .
M&L for insulation of field coils with Class ‘B’ insulation and Varnishing of field coil winding and drying up to desired temperature of DG Sets of capacity upto 100 KVA all as specififed and directed.
All as per Ser item No 51 here-in- before but of capacity 320 to 400 KVA .
Re-assembling of rotor and stator after rewinding and re-fixing of alternator with Engine by assembling flexible coupling with alternator, mounting with nuts & bolts including making cable connection complete including testing and commissioning at desired load of DG set of capacity upto 100KVA complete all as specified and directed.
All as per Ser item No 53 above but DG Set of capacity 320 KVA to 400 KVA.
Battery charging transformer, open execution type with diode bridge suitable for charging 12 volts, 180 AH battery with input voltage 230 volts AC all as specified and directed.
Supply and filling lubricant oil 20w40 for topping up/replacement including draining out old oil from engine chamber complete all as specified and directed. Make: Castrol/Volvoline/Servo/HP.
Supply and topping up heavy duty concentrate / antifreeze type coolant in radiator assembly of DG set complete including draining out of used coolant all as specified and directed. Make: Castrol/Volvoline/Servo/HP.
S&F in replacement of rechargeable lead acid battery, 12 volts, 180 AH complete all as specified. Make:- Exide make Exide Xpress model SAP code No. FXPO-MHD 1800 or equivalent in Amron.
S&F in replacement of rechargeable lead acid battery, 12 volts, 150 AH complete all as specified. Make:- Exide make Exide Xpress model SAP code No. FXPO-MHD 1500 or equivalent in Amron.
Supply and topping up distilled water suitable for lead acid battery all as specified. Make: As per sample
S&F in replacement of brass battery terminals suitable for 150/180 AH, 12 Volts battery complete all as specified.
Cleaning of light deposits with low pressure stream jet and if difficult deposits exist the removal should be done with application of detergent and using low pressure hot water hose or immersion in a heated alkali degreasant solution for 20 mins and washing off with hot water hose of radiator assembly of DG Set of capacity 200 to 100 KVA complete all as specified and directed.
Cleaning of light deposits with low pressure stream jet and if difficult deposits exist the removal should be done with application of detergent and using low pressure hot water hose or immersion in a heated alkali degreasant solution for 20 mins and washing off with hot water hose of radiator assembly of DG Set of capacity 75 to 25 KVA complete all as specified and directed.
S&F in replacement of AVR unit complete suitable for alternator of capacity upto 160 KVA matching with existing sample including making all electrical connection and setting at proper voltage complete all as specified.
S&F in replacement of AVR unit complete suitable for alternator of capacity 200 to 400 KVA matching with existing sample including making all electrical connection and setting at proper voltage complete all as specified.
S&F in replacement of charging alternator suitable for charging of 12 volts (1x12 volts), 180 AH battery complete including dismantling of existing and fixing the new fixing in position, making proper alignment complete all as specified and directed.
S&F in replacement of charging alternator suitable for charging of 24 volts (2x12 volts), 180 AH battery complete including dismantling of existing and fixing the new fixing in position, making proper alignment complete all as specified and directed.
M&L for cleaning of diesel tank of capacity 1000 Ltrs (approx) by taking out complete diesel in separate container, cleaning the all sludge, dust & mud of tank including refilling of diesel in tank complete all as specified and directed.
M&L for asbestos rope, 15 mm dia including laying over exhaust hood pipe of DG set of any capacity/size after removing existing complete all as specified.
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 25x4 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B1 using 12 mm graded crushed stone aggregate, RCC cover with handle, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil complete all as specified.
Disconnecting main electrical connection of voltage stabilizer of any make, capacity from 400 KVA to 100 KVA and opening of stabilizer cover for checking/examining/replacing as required including connecting the same electrical connection after necessary repair complete all as directed. Note: Spare parts shall be measured & paid separately.
Disconnecting main electrical connection of voltage stabilizer of any make, capacity from 75 KVA to 20 KVA and opening of stabilizer cover for checking/examining/replacing as required including connecting the same electrical connection after necessary repair complete all as directed. Note: Spare parts shall be measured & paid separately.
Transportation of voltage stabilizer of any make, capacity from 400 KVA to 100 KVA to civil workshop and returning back after necessary rewinding , repairing work including loading & un-loading with & including necessary T&P complete all as specified and directed.
Transportation of voltage stabilizer of any make, capacity from 75 KVA to 20 KVA to civil workshop and returning back after necessary rewinding ,repairing work including loading & un-loading with & including necessary T&P complete all as specified and directed.
Draining out the transformer oil complete quantity of voltage stabilizer of any make, capacity from 500 KVA to 100 KVA and to keep the same in safe containers dismantling all the parts of voltage stabilizer with the help of hand operated crane or other suitable mean, re-fixing the all parts and assembling with the help of hand operated crane or by other suitable means, re-filing the existing drain out transformer oil and testing the voltage stabilizer complete all as specified. Note:- Spare parts shall be measured & paid separately.
Draining out the transformer oil complete quantity of voltage stabilizer of any make, capacity from 75 KVA to 20 KVA and to keep the same in safe containers dismantling all the parts of voltage stabilizer with the help of hand operated crane or other suitable mean, re-fixing the all parts and assembling with the help of hand operated crane or by other suitable means, re-filing the existing drain out transformer oil and testing the voltage stabilizer complete all as specified. Note:- Spare parts shall be measured & paid separately.
M&L for re-winding of stabilizer of any type/make with superior quality super enamelled copper winding wire of suitable gauge and number of turns alongwith allied materials such as cork sheet, fibre glass insulation/paper isulation cotton, empire tape and woodeen blocks, bolts, nuts and washers, soldering and other packing materials complete all as specified and directed.
M&L for heat treatment at the workshop furnance of complete core before and after re-assembly of coil into limps after rewinding for stabilizer of any make/capacity complete all as specified and directed.
Repairing the voltage stabilizer of any make, capacity from 400 to 200 KVA by supply and fixing in replacement of following items:- (a) Electronic printed circuit board of solid state including ICs, regulators, condensors, triac, transistors complete.
(b) Circuit control/trigger transformer.
(c ) Main terminal block.
(d) Dimmer
(e) Choke coils.
(f) Carbon brush.
(g) Spacer for Dimmer coils.
(h) Resistance capacitance net work.
(i) Input switch to stop over running of dimmer start motor.
(j) Servo motor with 20 Kg.cm torque.
(k) Driving gear.
(l) Bearing for dimmer coils.
(m) Terminal connections brass rod with bush.
(n) Protection alarm circuit
Repairing the voltage stabilizer of any make, capacity from 150 to 100 KVA by supply and fixing in replacement of following items:- (a) Electronic printed circuit board of solid state including ICs, regulators, condensors, triac, transistors complete.
(b) Circuit control/trigger transformer.
(c ) Main terminal block.
(d) Dimmer
(e) Choke coils.
(f) Carbon brush.
(g) Spacer for Dimmer coils.
(h) Dimmer coils terminals.
(i) Input switch to stop over running of dimmer start motor.
(j) Servo motor with 10 Kg.cm torque.
(k) Driving gear.
(l) Bearing for dimmer coils.
(m) Terminal connections brass rod with bush.
(n) Protection alarm circuit
Repairing the voltage stabilizer of any make, capacity from 75 to 20 KVA by supply and fixing in replacement of following items:- (a) Electronic printed circuit board of solid state including ICs, regulators, condensors, triac, transistors complete.
(b) Circuit control/trigger transformer.
(c ) Main terminal block.
(d) Dimmer
(e) Choke coils.
(f) Carbon brush.
(g) Spacer for Dimmer coils.
(h) Dimmer coils terminals.
(i) Input switch to stop over running of dimmer start motor.
(j) Servo motor with 10 Kg.cm torque.
(k) Driving gear.
(l) Bearing for dimmer coils.
(m) Terminal connections brass rod with bush.
(n) Protection alarm circuit
S&F for replacement of current transformer of ratio 100/5 Amps (Set of three) all as specified and directed.
S&F for replacement of current transformer of ratio 200/5 Amps (Set of three) all as specified and directed.
Supply and replacement of digital ampere meter of suitable range as per existing size all as specified and directed.
Supply and replacement of digital voltmeter 0-500 volts as per existing size all as specified and directed.
Supply and replacement of digital frequemcy meter as per existing size all as specified and directed.
Supply & toping up of new transformer oil (in sealed barrel) having dielectric strength 50KV at 2.5mm gap after initial dehydration complete all as specified. (Note: Contractor shall make a arrangement for filtration of new transformer oil so that it can used for toping after acheiving dielectric strength 50KV at 2.5 mm gap) Make: Savita/Castrol/Power oil
S&F automatic transfer switch (ATS) 200 Amps, 415 Volts, 4 pole, 50 Hz, automatic/manual type with inbuilt time delay complete with enclosure including dismantling existing main switch all as specified. Make: Havells cat part No. IHYTCDE200 or equivalent in Standard/L&T.
S&F in replacement of ONLOAD changeover switch, 4 pole, 415 volts, 50 Hz, 400 Amps, open execution type complete including making of electrical connection all as specified. Make: L&T/HPL/Havells.
S&F in replacement of ONLOAD changeover switch, 4 pole, 415 volts, 50 Hz, 250 Amps, open execution type complete including making of electrical connection all as specified. Make: L&T /HPL/Havells.
S&F in replacement of ONLOAD changeover switch, 4 pole, 415 volts, 50 Hz, 63 Amps, open execution type complete including making of electrical connection all as specified. Make: L&T /HPL/Havells.
Note :- An amount of Rs. 22,765.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S ABBAS M. ENTERPRISES
M/S BASHIR AHMAD AND SONS
MS Ghulam Hassan and Sons
FG CONSTRUCTION
M/S Gh Qadir and Sons
ORISON ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .