Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 LAccepted-AOC 144 SANTOSH ROY ROAD BARISHA KOLKATA 700008 | KOLKATA | KOLKATA | WEST BENGAL | 700008 | ₹4.0 L | L1 | Accepted-AOC Work Order issued |
| 2 | L2₹4.2 LRejected-Finance MEGHNATH SAHA ROAD P O PANIHATI KOLKATA 700114 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700114 | ₹4.2 L | L2 | Rejected-Finance Not L1 Bidder |
| 3 | L3₹4.3 LRejected-Finance 17 MOHYIAR 1ST BYE LANE JIGACHA HOWRAH 711112 | HOWRAH | HOWRAH | WEST BENGAL | 711112 | ₹4.3 L | L3 | Rejected-Finance Not L1 Bidder |
| Sl No | Description | Qty | Unit | KAJAL CHANDRA L2 | H.N.TRADING L3 | VINAYAK APPLIANCES L1 |
|---|---|---|---|---|---|---|
| 1.00 | S&D of min 4.0TR Capacity fixed speed cassette Split Air Conditioner of minimum Cooling Capacity of 47944 BTU/hr or 14060Watt with 1 nos of twin rotary Compressor, 1 nos IDU of Rated Power Supply -220-240V/1PH/50Hz connected with 1 no ODU of Rated Capacity Supply 400V/3PH/50Hz . Min Air Flow/IDU - 1000 CFM . Connection Pipe Size (Liquid & Gas) - OEM standard. Maximum Noise Level 50dB at indoor, Refrigerant- R410A / R32, wireless controller with remote and electrical supply line of outdoor unit controlled by four pole suitable capacity isolator. (Make - Hitachi / Carrier / O-general / Mitshubishi heavy / Voltas). Delivery and unloading the same materials also included. | 1 | No | 1,45,000 ₹1.4 L | 1,48,000 ₹1.5 L | 1,38,000 ₹1.4 L |
| 2.00 | S&D of min 1.8TR capacity fixed speed high wall split air conditioner of minimum cooling capacity of 6200watt or 20814 BTU/Hr with 1no of rotary compressor, 1nos IDU & ODU of rated power supply 220-240V / 1Ph / 50Hz. Min air flow/IDU 600 CFM. Maximum noise level 39dB at indoor, Refrigerant- R410A / R32, wireless controller with remote. (Make - Hitachi / Carrier / O-general / Mitshubishi heavy / Voltas). Delivery and unloading the same materials also included. | 2 | Nos | 44,500 ₹89,000 | 45,500 ₹91,000 | 42,000 ₹84,000 |
| 3.00S&D of following size refrigerant pipe line by min 1.0 mm thick soft Cu pipe complete including supporting arrangements, nitrile rubber insulation, wrapping tape etc. Also Supply of min 9mm (G) & 6mm (L) thick nitrale insulation (Delivery and unloading the same materials also included. | ||||||
| 3.10 | 3/4" dia (G) & 1/2" dia (L) pipe (or OEM recomended pipe size) for 4TR AC machine. | 16 | RM | 1,550 ₹24,800 | 1,650 ₹26,400 | 1,490 ₹23,840 |
| 3.20 | 5/8" dia (G) & 1/4" dia (L) pipe (or OEM recomended pipe size) for 1.8 - 2TR AC machine. | 32 | RM | 1,175 ₹37,600 | 1,175 ₹37,600 | 1,200 ₹38,400 |
| 4.00 | S & F of 20mm PVC rigid conduit along with all required necessary accessories as per GS. (Make: Precesion MMS) | 128 | RM | 145 ₹18,560 | 145 ₹18,560 | 140 ₹17,920 |
| 5.00 | S & L of 1.1 KV Grade 4C x 2.5sqmm PVC insulated flexible copper cable for indoor to outdoor (Finolex / Polycab / Havells/Gloster) through existing prelaid PVC rigid conduit. | 54 | RM | 180 ₹9,720 | 180 ₹9,720 | 190 ₹10,260 |
| 6.00 | Installation of 1.8tr to 4tr ceiling mounted indoor unit and outdoor unit on installed base frame after, S & F of tie rods min 8mm dia, anchor fastners for tie rod min 50mm long, nuts, washers, screws etc. S&F of anti vibration pads, nut bolts as per direction of EIC. Also fixing of refrigerent pipes along with insulation, MS supports, brazing when total refrigernt line exceeds 49fts, wrapping tape etc. After completing the installation work commissioning the same AC unit after nitrogen flashing and holding as per direction of EIC. | 1 | No | 5,000 ₹5,000 | 5,000 ₹5,000 | 4,710 ₹4,710 |
| 7.00 | Installation of upto 1.8tr wall mounted indoor unit and outdoor unit on installed base frame after, S & F of anchor fastners, nut bolts, washers, screws etc. S&F of anti vibration pads, nut bolts as per direction of EIC and S & F required angle iron structure on wall for placing ODU & mending good the damages. | 2 | Nos | 1,850 ₹3,700 | 1,850 ₹3,700 | 1,720 ₹3,440 |
| 8.00 | SITC of 25mm UPVC rigid pipe drain line (complete set like elbow, Tee, reducer, adhesive material etc) with 12.5mm thick intrale insulation along with support by MS section as per direction of EIC. (Approve make) | 8 | RM | 195 ₹1,560 | 195 ₹1,560 | 183 ₹1,464 |
Tender Value
Refer Docs
EMD Value
₹8,000
Closing Date
21 Jan 2026, 12:55 pmClosed
Assistant Engineer-I Electrical,NESD,PWD
Office of the Assistant Engineer-I, Nabanna Electrical Sub-Division, PWD. Nabanna,325 Sarat Chatterjee Road, Shibpur,Howrah PIN - 711102
SITC of AC machines at the chamber of ACS of Finance Department at RM 1212 Nabanna, Project ID-FD252644931S000.
2025_WBPWD_970794_1
13/Q of AE-I NESD 2025-26
Open Tender
ELECTRICAL WORKS ORG
Nabanna, the state secretariat building.
Please refer Tender documents.
9 documents required · 9 mandatory
₹8,000
20 Apr 2026
11 Dec 2025
27 Jan 2026
11 Dec 2025
21 Jan 2026
11 Dec 2025
stage.html
html • 0.05 MB
technical_2361117.pdf
techsummary_2361117.pdf
finance_2361117.pdf
BOQ Comparative Chart
xlsx
finsummary_2361117.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.63 MB
form29111.pdf
Tender Documents • 0.50 MB
BOQ_2361117.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid