Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.1 LAccepted-Finance | 1 | Accepted-Finance Accepted | |
| 2 | Rejected-Technical ERAL | - | Rejected-Technical Rejected |
Tender Value
₹12 L
EMD Value
₹12,000
Closing Date
8 May 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Officer
Executive Officer Perungulam Town Panchayat
Construction of Library Building at Perungulam in Perungulam Town Panchayat.
2025_DTP_551584_1
587/2024
Open Tender
Civil Works
Works
90 days
Perungulam Town Panchayat
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹12,000
Yes
14 Jul 2025
26 Apr 2025
9 May 2025
26 Apr 2025
8 May 2025
26 Apr 2025
Amount
Earthwork excavation for foundation in all soils and sub soils in hard stiff clay, stiff black cotton, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size boulders and to full depth as may be directed,except in hard rock,requiring blasting including shoring and shuttering and bailing out of water wherever necessary,refilling the sides of foundation with excavated earth or sand in layer of not more than 15cm thick.well rammed and consolidated and depositing on bank with initial lead and lift of 10m & initial lift of 2m and depositing the surplusr earth within the compound in places shown by the departmental officers with iniital lead and lifts,clearing and levelling the site etc., complete as per SS20B and as directed by departmental Engineers(TNBP No.17,23,24).
Plain Cement Concrete 1:4:8 mix (One Part of Cement, Four part of Fine Aggregate and Eight part of Coarse Aggregate) Using 40mm ISS HBG metal for foundation and basement including dewatering if found necessary and laid in layer of not more than 15cm thick and consolidated including all cost conveyance of materials and labour charges etc. complete as per standard specifications and as directed by departmental Engineers(TNBP No.28).
Supplying and erecting steel centering for sides and sophist of including necessary supports and shuttering to the required height for RCC items using MS sheets or suitable size of BG10 stiffened with welded MS angles of size 25mm x 25mm x 3mm of boarding. Laid over silver oak joints of size 10cm x 6.5cm spaced at 90cm center to center and supported by casuarinas props of 10cm to 13cm dia spaced at75cm centre to centre complying with standard specifications etc., completed.
Column Surface
Plain Surface
Reinforced Cement Concrete 1:1.5:3 mix (One cement and One and a half Fine Aggregate and Three Coarse Aggregate) Using 20mm ISS HBG metal including all cost conveyance of materials and labour charges for curing,finishing but excluding centering,shuttering and cost of reinforcement grills, including vibrating charges etc. complete as per standard specification and as directed by departmental Engineers(TNBP No.30).
Supplying, fabricating and placing in position mild steel or TMT rods for all reinforced cement concrete works as per design given including cost of steel and binding wire with all conveyance and lead charges in all floors etc.complete complying with standard specifications and as directed by the deparmental engineers. TNBP No:30
Brick Work in CM 1:5 (One part of cement & five parts of sand) mix using Third Class Country Brick Kiln Burnt bricks 8 ¾ " x 4 ¼ " x 2 ¾" including cost and conveyance of materials to work site and including all labour charges for mixing, laying, curing the concrete etc., complete as per standard specifications and as directed by departmental Engineers – TNBP No:31
Special Ceiling Plastering with CM 1:3 (One part of cement & three parts of sand)mix for 10mm thick including cost and conveyance of materials to work site and including all labour charges for mixing, laying, curing,finishing etc., complete as per standard specifications and as directed by departmental Engineers – TNBP No:30,56&57
Plastering with CM 1:4 (One part of cement & four parts of sand) mix for 12mm thick including cost and conveyance of all materials to work site and including all labour charges for mixing, laying, curing,finishing etc., complete as per standard specifications and as directed by departmental Engineers – TNBP No:56&57
Daddoing with first quality colour glazed tiles of 150 mm x 150 mm x 6mm size of approved make and quality and colour set in Cement Mortar 1:2 (One Cement and Two Sand) and pointing with white cement neatly including cost and conveyance of all materials etc.and all lobour charges etc.complete as per Standard specification and as directed by the departmental officers.TNBP No:special
Paving the floor with designed coloured vitrified tiles of size 600 x 600 x 8mm of best quality and approved variety complying / confirming ISI specification land over cement mortar 1:3 (one cement and three sand) 20mm thick and pomted with same coloured cement neatly etc., complete.
Providing UPVC (Un-Plasticized Polyvinyl Chloride)Door: Providing and fixing casement doors fabricatedfrom un-plasticized polyvinyl chloride (uPVC) sections.Profiles: The profiles should be three chamber systemwhich provides high insulation properties with outerframe 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with allcorner joints mitred and fusion welded. Windowsshould be steel reinforced with 25 x 24 x 25mm steelreinforcement with a thickness of 1mm to havedimensional stability. The sash should be of 60 x102mm. The mullion should be of 60 x 74mm. Theprofiles should have co-extruded seals.Hardware: All the hardware like friction stays, handlesshould be screwed withself tapping screws. Thehandles, locks should be designed so that they cannotbe released from outside.Glazing: The window system should be glazed with5mm plain float glass / 6mm bison lamInstallation: The profiles should be cut to length andwelded 45 degrees. The window should be designedsuch that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug. and all labour charges to require size to site etc., complete..
Supplying and fixing M.S Grill to doors, special windows and ventilators etc using 20mmx6mm as directed by the departmental officers inclusive of cost of MS grill including one primer coat of red oxide and fixing in position etc. including cost and conveyance of all materials and all lobour charges etc.complete as per Standard specification and as directed by the departmental officers.(as per the schedule of rate)TNBP No:86 & 86-A
Painting the new walls two coats over one coat of priming with best weather proof Exterior Emulsion paint of approved colour and quality including preparation of surface and finishing neatly etc., complete complying with standard specification and as directed by departmental officers Complete as per standard specification.
Painting with two coats of Approved colour of best quality synthetic enamel paint, painting over new iron work including cost and conveyance of all materials and all labour charges etc. complete as per Standard specification and as directed by the departmental officers. (New Iron Surface).TNBP No:66&66-A
Wiring with 2x1.5sqmm (22 / 0.3) PVC insulated SC unsheathed Cu. Conductor of 1100v grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T switch and making good of the concealed portion with suitable colour for PVC concealed light point. SD 24 ISI Make with Standard specification .
Wiring 2 x 1.5 sq.mm (22/0.30)PVC insulated unsheathed SC.cu. conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with in flush with wall covered with hylem sheet of 3 mm thick with painting of suitable colour for open PVC plug point (SD No.36) 5 pin plug point
Supply and fixing of 18 Watts 4 Feet LED fitting complete with copper choke and condenser with TW Round on wall and with tube with PVC unsheathed leads from ten nauble to the netting. ISI Make with Standard specification .sd 88
Supply and fixing of 30 watts LED single street light fitting etc., complete. ISI Make with Standard specification .
Supply and fixing of 7 / 9 watts LED Bulb etc., complete. ISI Make with Standard specification .
supply and fixing of 1200mm sweep AC ceiling fan complete with stepped electronic regulator with 300mm down rod on the existing clamp SD 106
Supply and run off of2 of 6 sq.mm (84 / 0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V grade on 7/20 GI bearer wire for service connection mains . SD 64 . ISI make with standard specification.
Supply and run off of 2 of 6 sq.mm (84 / 0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V grade in 25mm dia GI pipe (Class ‘B’) bent at both ends with necessary angle iron up right and end supports. SD 69 . ISI make with standard specification.
Supply and fixing of 16 Amps DPIC switch of 500 V with metal clad with fuse and netural TW Board with earth connection only. SD 142. ISI make with standard specification.
ATHIVEL (BID ID -1331904)
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
finance_658420.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .