Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.9 CrAccepted-AOC | ₹33.9 Cr | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹34.0 CrRejected-Finance | ₹34.0 Cr | L2 | Rejected-Finance NOT BEING L1 |
| 3 | L3₹37.7 CrRejected-Finance | ₹37.7 Cr | L3 | Rejected-Finance NOT BEING L1 |
| 4 | L4₹39.8 CrRejected-Finance | ₹39.8 Cr | L4 | Rejected-Finance NOT BEING L1 |
| 5 | L5₹42.4 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹42.4 Cr | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹31 Cr
EMD Value
₹15 L
Closing Date
10 Jul 2023, 6:00 pmClosed
CHIEF ENGINEER (CG) GOA
CHIEF ENGINEER (CG) GOA 403806
CONSTRUCTION OF DEFICIENT MARRIED ACCOMODATION FOR SOS AND CIVILIANS AT NATIONAL CAPITAL REGION NCR SECTOR 23 NOIDA UNDER AGE I COAST GUARD NOIDA
2023_MES_589466_1
83012/e8
Open Tender
Civil Works
750 days
NOIDA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
AGE (I) CG NOIDA
₹15 L
Yes
22 Aug 2023
14 Apr 2023
12 Jul 2023
14 Apr 2023
10 Jul 2023
22 May 2023
Amount
Total amount of Sch 'A' Section I (Building & Structure work) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section I)
Total amount of Sch 'A' Section II (Excavation, Earth work & Site Clearance) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section II)
Total amount of Sch 'A' Section III (Internal Water Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section III)
Total amount of Sch 'A' Section IV (Internal Electrification) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section IV)
Total amount of Sch 'A' Section V (Area Drainage) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section V)
Total amount of Sch 'A' Section VI (Sewage Disposal) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section VI)
Total amount of Sch 'A' Section VII (Road, Path & Culvert) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section VII)
Total amount of Sch 'A' Section VIII (Compound wall, fencing & Gate) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section VIII)
Total amount of Sch 'A' Section IX (Rain Water Harvesting System) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section IX)
Total amount of Sch 'A' Section X (External Water Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section X)
Total amount of Sch 'A' Section XI (External Electric Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XI)
Total amount of Sch 'A' Section XII (Fire Fighting E/M WORKS) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XII)
Total amount of Sch 'A' Section XIII (Lift & DG Set) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XIII)
Total amount of Sch 'A' Section XIV (LIGHTENING PROTECTION) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XIV)
Total amount of Sch 'A' Section XV (Hot Water Supply & Aviation Obstruction Light,) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XV)
Total amount of Sch 'A' Section XVI (TV /Tele Cable, Fresh Air Fan & AC Point Tender ) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XVI)
Total amount of Sch 'A' Section XVII (STP (SEWAGE TREATMENT PLANT) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XVII)
Total amount of Sch 'A' Section XVIII (SHIFTING OF EXTERNAL SERVICES) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XVIII)
Total amount of Sch 'A' Section XIX (Demolition & Dismantling) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section XIX)
SCHEDULE "A" PART -XX (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' E ' signifies this fact only.
INTERNAL ELECTRIC SUPPLY :- S&F modular blank plate module 1 complete all as specified and directed.
S & F LED bracket light fitting 1x 12 W, 220V,AC LED Lamp decorative wall mounting fixture made up of Aluminum body including LED 12 watt with System level efficacy of the Luminary is > 90 lm/W , Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6500K, Surge protection of 4.0 KV, including connecting up with necessary PVC sheathed 3 core 1.5 Sqmm copper conductor flexible wire fixed complete all as specified and directed
S & F vertical distribution board, double door, 4 way, VTPN rotection class IP-42, suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 200 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. (1no. in each floor) (Note :- MCCB & MCB Shall be measured and paid seperately)
Design, manufacture, supplying, fixing, testing and commissioning of the following 2 mm thick sheet steel enclosed, wall mounting, dust and vermin proof with IP 42 protection triple pole and with 100% neutral Rising Mains with PVC insulated aluminum bus bars with a maximum current density of 1 amp per sq mm and suitable to withstand a symmetrical fault level of 35 kA at 415 volts, complete with fire proof barriers at every floor level, expansion joints, thrust pads to support weight of busbars, fully gasketed covers, with arrangement to plug in tap off boxes as required and connecting chamber for incoming isolator, powder coating, complete with fixing arrangements as required and with 2 runs of aluminum strip for earthing as required .(Rising Mains for Building) of 800A Capacity
SEWAGE DISPOSAL :- M & L for steel fibre reinforeced concrete (SFRC) man hole covers medium duty circular of size 600mm dia and 80mm thick with MS handle complete all as specified and directed.
ROAD, PATH AND CULVERT :- S&F road safety 800mm dia convex polycarbonate acrylic unbreakable mirror fixed over and incl 2100mm ht above GL of 75mm dia SS pipe above road surface fixed in ground with PCC 1:2:4 min 450mm deep in ground complete all as specified and directed.
S&F Sign boards made of 3mm thick ACP sheet area exc 1.1 sqm but not exc 1.8 sqm info printed or pasted with high intensity retro-reflective tape computer cut in specified colour & font as directed by Engr-in-charge mounted over all around frame and legs of 50mm SS pipe of max top ht 2100mm above GL complete fixed in ground with PCC 1:2:4 min 450mm deep complete all as specified and directed.
RAIN WATER HARVESTING SYSTEM :- M&L for drilling 250mm dia bore hales by DTH cum rotatory method at any depth below the ground level in any kind of rock/ soil upto 40m depth including disposal of surplus soil to a distance not exceeding 50m complete all as specified & directed.
M&L for Self perforated unplasticized PVC pipes 250mm dia of pressure rating 10 Kg/Sqm, fixed complete to wall or ceiling or in floors complete all as specified and directed.
EXTERNAL WATER SUPPLY :- Supply,laying,jointing,testing pipe ductile Iron 100 mm dia ,pressure pipe with spigot and socket ends ,Class “K-7” confirming to IS:8329/2000 suitable for push on rubber gasket jointing with centrifugally applied inside cement mortor lining with portable slag cement as per IS : 455: 1989 and external metallic zinc coating with finshing layer of bituminous coating including EPDM rubber joint complete all as specified and directed.
S & F DI fitting for spigot nand socket/ flanged ends pipe like Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs,connecting pieces one end flanged and other end socket or spigot and bell mouth pieces one end flanged other end tapring as bell mouth suitable for 100 mm dia pipe complete all as specified and directed.
S&F Valve, Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe conforming to IS 778/1980, 80 mm bore Pipe complete including connecting all as specified and directed.
Supply,install,testing and commisioning of openwell submersible pump set electric driven 3 phase 415 Volts 50 Hz 2900 RPM having head not less than 60 meter and discharge not less than 7 LPS having cast iron cashing, cast iron impeller,stainless steel C40 shaft,Bronze shaft sleeve complete including provision of necessary foundation of pump set including MS pipe medium grade from delievery side of pump to discharge header with connected flanges,nut bolts,gasket etc. including necessary foundation work and other associated work complete with provision of following all as specified and directed:- (a) Common base plate for motor and pump set-01 No. (b) Suitable gun metal strainer as directed and recommended by manufaturer. (c) MS pipe medium grade from delievery side of pump to discharge header with connected flanges,nut bolts,gasket etc. (d) Suitable size copper cable from motor to starter. (e) Suitable size Non return valve recommended by manufaturer. (f) Suitable size cast iron foot valve recommended by manufaturer. (g) Suitable size sluice valve on discharge side recommended by manufaturer.
Supply and fix Cable with copper conductor PVC round sheathed (flexible) industrial cable 10 Sqmm 3 core complete all as specified and directed.
Supply and fix Cable with copper conductor PVC round sheathed (flexible) industrial cable 16 Sqmm 3 core complete all as specified and directed.
Supply, installing, testing and commissioning factory made, floor mounted indoor type LT panel board, cubicle type, suitable for 415 Volts, 3 Phase, 4 wire, 50 Hz, AC supply system, and tested at CPRI, having 200 Amps capacity copper bus bar for phase and 200 Amps copper bus bar capacity for neutral , colour coded for each phase and neutral, insulated on epoxy type insulators. The bottom of the outer shell contains a detachable plate having provn for entry of cable of adequate size with glands, The panel shall be dust and vermin proof, IP-65 class protection and made 2.00 mm thick CRCA MS sheet, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, provision of connecting earth strip from 2 sides, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm) including grouting of panel 45 cm above ground level by providing 90 cm long angle iron frame of size 40x40x6 mm, welded on all the four corners, embedded in PCC 1:2:4 using 20 mm stone aggregate upto 30 cm above ground level complete all as specified and directed including the following accessories:-
a) MCCB 3 pole motor protection circuit breaker 415 Volts 16 KA 100 Amps with extendable terminal -01 Nos (In coming)
(b) Provn of fully automatic star delta starter with 63 amps TP power contactors ,NO/NC Aux contact , O/L relay & SD timer etc for 15 HP submersible pumpset -02 Nos.
(d) Start/Stop push buttons - 02 Nos each
(e) Phase indication -RYB & Motor ON/ OFF/Trip indicating lamps LED type - 09 Nos.
(f) Control fuse with link- -03 Nos Make : Bussmann/ FARAZ/ Seimens
(h) Phase sequence corrector switch 3 pole, on load type, open execution, 100 Amps Make: BCH/L&T /Siemens / Schneider / ABB/HPL - 01 No.
(j) Single phasing preventer- 01 No Make : Minilac/L&T (k) MCB of desired rating -04 Nos & connectors as per requirement. (l) One no. danger notice plate
Material and laboure for construction of valve chamber of size 900 mm x 900 mm x 900 mm dimensions (Over all internal dimension) for sluice valve etc. with PCC foundation, PCC block masonry walls, Plastering, PCC Coping, white washing, mild steel chamber cover, painting to chamber cover including Excavation and earth work in any type of soil complete all as specified below:- Valve chamber shall be provided with the following specifications:- (i) Cement concrete for foundation (1:4:8) type D2 using 40mm graded stone aggregate 150 mm thick extended up to 150 mm beyond the outer face of block masonry. (ii) Walls of valve chamber 200 mm thick with precast cement concrete (1:5:8) (using 20mm graded stone aggregate) solid building blocks , setting in CM 1:6 complete. (iii) Internal and exposed surfaces of valve chamber both concrete and block masonry surface shall be plastered with CM (1:4), 15 mm thick finished even and smooth. (iv) 50 mm thick coping in PCC 1:3:6 type C1 over block masonry wall. (v) Entire plastered surfaces shall be treated with 3 coat of white wash. (vi) Chamber cover shall be of 3 mm thick MS sheet with 30 x 30 x 5 mm size angle iron frame with hold fast and locking arrangement . steel surface shall be painted with two coats of synthetic paint of first quality over one coat of red oxide primer.
Material and labour for construction of valve chamber of size 1000 mm x1000 mm x 1000 mm dimensions (Over all internal dimension) for sluice valve etc. with PCC foundation, PCC block masonry walls, Plastering, PCC Coping, white washing, mild steel chamber cover, painting to chamber cover including Excavation and earth work in any type of soil complete all as specified below:- Valve chamber shall be provided with the following specifications:- (i) Cement concrete for foundation (1:4:8) type D2 using 40mm graded stone aggregate 150 mm thick extended up to 150 mm beyond the outer face of block masonry. (ii) Walls of valve chamber 200 mm thick with precast cement concrete (1:5:8) (using 20mm graded stone aggregate) solid building blocks , setting in CM 1:6 complete. (iii) Internal and exposed surfaces of valve chamber both concrete and block masonry surface shall be plastered with CM (1:4), 15 mm thick finished even and smooth. (iv) 50 mm thick coping in PCC 1:3:6 type C1 over block masonry wall. (v) Entire plastered surfaces shall be treated with 3 coat of white wash. (vi) Chamber cover shall be of 3 mm thick MS sheet with 30 x 30 x 5 mm size angle iron frame with hold fast and locking arrangement . steel surface shall be painted with two coats of synthetic paint of first quality over one coat of red oxide primer.
Supply,install,testing and commisioning of Heavy duty Chemical Dosing system plunger type suitable to inject solution upto 25 LPH working pressure 10 kg /cm2 comprising dosing pump coupled with three phase electric motor of capacity 0.5 HP,1440 RPM assembly with agitator in one motor , agitator with SS sweep blade duly FRP coated, FRP tank 150 ltrs capacity, complete unit mounted on heavy duty MS fabricated frame duly anticorrosive paint complete with Chemical grade PVC NRV. along with Control panel for Dosing Pump suitable for Model SSAPS/CDSPT/25 made of powder coated MS fabricated box consisting of LED indicator, digital Volt meter, Amp meter, single phase preventor, High voltage low voltage protection.. Make : SatyaSai Aqua Pura Services Model No:- SSAPS/CDSPT/25 or equivalent of make as approved by E in C till last date of bid submission
S & F for MS Pipe header 300mm dia size 2 mtr length with flanged ends closed with end plates not less than 16mm thick fixed with nut and bolts with washers and rubber gaskets with and including provision of following incoming and out going connections of length 450mm with flanged and including painting with two coat of enamel paint over a coat of red oxide primer including brick masonry support pillers of suitable size with PCC 1:2:4 in foundation,plastering around with 1:4 cm 10 mm thick and coping 10cm thick all as specified and directed by Engineer-in- in charge with following provision:-
(a) 100mm dia 500mm long MS pipe with MS Flange 16mm thick incoming -2 Nos
(b) 80mm dia 500mm long MS pipe with MS Flange 16mm thick outgoing -2 Nos
S & F for MS Pipe header 300mm dia size 3 mtr length with flanged ends closed with end plates not less than 16mm thick fixed with nut and bolts with washers and rubber gaskets with and including provision of following incoming and out going connections of length 450mm with flanged and including painting with two coat of enamel paint over a coat of red oxide primer including brick masonry support pillers of suitable size with PCC 1:2:4 in foundation,plastering around with 1:4 cm 10 mm thick and coping 10cm thick all as specified and directed with following provision
(a) 100mm dia 500mm long MS pipe with MS Flange 16mm thick incoming -2 Nos
(b) 100mm dia 500mm long MS pipe with MS Flange 16mm thick outgoing -2 Nos
(c) 80mm dia 600mm long MS pipe with MS Flange 16mm thick outgoing -2 Nos.
(d) 50mm dia 600mm long MS pipe with MS Flange 16mm thick outgoing -2 Nos.
EXTERNAL ELECTRIC SUPPLY Supply, installing, testing and commissioning factory made, floor mounted indoor type LT panel board, cubicle type, suitable for 415 Volts, 3 Phase, 4 wire, 50 Hz, AC supply system, and tested at CPRI, having 1000 Amps capacity alluminium bus bar for phase and 1000 Amps alluminium bus bar capacity for neutral , colour coded for each phase and neutral, insulated on epoxy type insulators. The bottom of the outer shell contains a detachable plate having provn for entry of cable of adequate size with glands, The panel shall be dust and vermin proof, IP-65 class protection and made 2.00 mm thick CRCA MS sheet, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type,provision of connecting earth strip from 2 sides, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm) including grouting of panel 45 cm above ground level by providing 90 cm long angle iron frame of size 40x40x6 mm, welded on all the four corners, embedded in PCC 1:2:4 using 20 mm stone aggregate upto 30 cm above ground level complete all as specified and directed including the following accessories:-
(a) ACB Four Pole ,microprocessor based O/L,S/C and E/F releases,Icu=100% Ice,manualdraw out type IPR-E of capacity 1000 Amps 50 KA,415 Volts - 01 No (Incomer)
(b) MCCB TP 400 Amps 35 KA 4 pole thermal magnetic type(out going) - 05 Nos
(c) MCCB TP 63 Amps 4 pole 16 KA thermal magnetic type (out going) -01 No
(d ) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set
( e) Indicating lamp Red,yellow,green - 01 Set
(f) Protection MCB 6 Amps Single pole- 03 Nos.
(g) CT 1000/5 A- 03 Nos.
(h) One no. danger notice plate
Supply, installing, testing and commissioning factory made, floor mounted indoor type LT panel board, cubicle type, suitable for 415 Volts, 3 Phase, 4 wire, 50 Hz, AC supply system, and tested at CPRI, having 600 Amps capacity Alluminium bus bar for phase and 600 Amps alluminium bus bar capacity for neutral , colour coded for each phase and neutral, insulated on epoxy type insulators. The bottom of the outer shell contains a detachable plate having provn for entry of cable of adequate size with glands, The panel shall be dust and vermin proof, IP-65 class protection and made 2.00 mm thick CRCA MS sheet, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type,provision of connecting earth strip from 2 sides, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm) including grouting of panel 45 cm above ground level by providing 90 cm long angle iron frame of size 40x40x6 mm, welded on all the four corners, embedded in pcc 1:2:4 using 20 mm stone aggregate upto 30 cm above ground level complete all as specified and directed including the following accessories:-
a) MCCB 4 pole 35 KA 400 Amps with thermal magnetic type -01 No (In coming)
b) MCCB 4 pole 25 KA 200 Amps with thermal magnetic type -01 No (Out coming)
c) MCCB 4 pole 25 KA 100 Amps with thermal magnetic type -04 Nos. (Out coming)
d) MCCB 4 pole 16 KA 63 Amps with thermal magnetic type -01 No (Out coming)
e) MCB 4 pole 10 KA 32 Amps C Curve -01 Nos. (Out coming)
f) MCB 4 pole 10 KA 16 Amps C Curve -02 Nos. (Out coming)
g ) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set
h) Indicating lamp Red,yellow,green - 01 Set
j) Protection MCB 6 Amps Single pole- 03 Nos.
k) CT 400/5 A- 03 Nos.
l) One no. danger notice plate
Supply, installing, testing and commissioning factory made, floor mounted indoor type LT panel board, cubicle type, suitable for 415 Volts, 3 Phase, 4 wire, 50 Hz, AC supply system, and tested at CPRI, having 150 Amps capacity alluminium bus bar for phase and 150 Amps alluminium bus bar capacity for neutral , colour coded for each phase and neutral, insulated on epoxy type insulators. The bottom of the outer shell contains a detachable plate having provn for entry of cable of adequate size with glands, The panel shall be dust and vermin proof, IP-65 class protection and made 2.00 mm thick CRCA MS sheet, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, ,provision of connecting earth strip from 2 sides,including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm) including grouting of panel 45 cm above ground level by providing 90 cm long angle iron frame of size 40x40x6 mm, welded on all the four corners, embedded in pcc 1:2:4 using 20 mm stone aggregate upto 30 cm above ground level complete all as specified and directed including the following accessories:-
a) MCCB 4 pole 25 KA 100 Amps wiyh thermal magnetic type (In coming)-01 No.
b) MCB 4 pole 10 KA 32 Amps C Curve - 04 Nos
c) MCB 4 pole 10 KA 16 Amps C Curve -02 Nos
d ) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set
e) Indicating lamp Red,yellow,green - 01 Set
f) Protection MCB 6 Amps Single pole- 03 Nos.
g) CT 100/5 A- 03 Nos.
h) One no. danger notice plate
(2) 02 Nos. high speed tripping relay with reset contacts , electro mechanical type, Master trip relay 02 Nos.,Anti pumping relay 02 Nos., Auxilary relay 02 Nos. (g) LED indicating lamps (RYB) , Breaker ON, Breaker OFF, spring charged, Trip circuit healthy, with push button, auto trip indicator, RYB phase indications. (h) Switch for closing/tripping of VCB (j) Space Heater with switch , thermostat and ilumination. (k) 3pin plug socket with switch. (l) Hooter (m) 6 Watt amnnuciator (n) Emergency push button (o) Toggle switch,door switch and control MCBs
Supply and fix compact air insulated bus bar trunking system with copper busbar 1250 Amps,50 KA breaking capacity,IP 54 protection with rated voltage 1000 Volts,12 KV rated impulse withstand voltage, GI enclosure material complete including testing and connecting all as specified and directed.
FIRE FIGHTING E/M WORKS Supply fixing ,tesing ,commisioning of first aid rubber hose reel of 20 mm dia and 30 meter length mounted on and including drum with swing type bracket for housing to withstand 10 kg/Sqcm working pressure fitted with alloy nozzle complete all as specified and directed.conforming to IS 5132 all as specified and directed.
Supply and fix branch pipe with nozzle confirming to IS: 903 suitable for instanteneous connection to hose coupling etc as required.
Supply,laying,cutting to required length ,jointing,testing and commisioning MS Pipe of size 150 mm nominal bore heavy grade as per IS-1239 along with all fittings /special such as bends,tee colars ,reducer etc including welding flanges heavy duty on both ends of pipe and fittings for making joints,complete with nut,bolthigh tensile washer and rubber gasket of superior quality laid on trenches complete all as specified and directed.
Supply,laying,cutting to required length ,jointing,testing and commisioning MS Pipe of size 80 mm nominal bore heavy grade as per IS-1239 along with all fittings /special such as bends,tee colars ,reducer etc including welding flanges heavy duty on both ends of pipe and fittings for making joints,complete with nut,bolthigh tensile washer and rubber gasket of superior quality laid on trenches complete all as specified and directed.
Supply , fixing ,testing and commisioning of single headed gun metal ISI marked oblique pattern hydrant landing valve with 80 mm dia flanged inlet and 63 mm dia instanteneous type female outlet complate with gun metal cap and chain twist release lug and all other accesories as per IS 5290 complete all as specified and directed.
Supply and fix electric motor siren conforming to IS 1941 suitable for three phase 415 V supply with motor not exceeding 3.75 KW power and able to deliver 143 DB noise level complete all as specified and directed.
Supply and fixing ,testing and commisioning ERW/MS pipe (heavy) confirming to IS-1239/IS 3589 with required accesories and pipe fiting like flanges,elbow,tee,elbow,bend,nipple coupling cap,reducers etc andradiography limited to 10% and shall be provided anti corrosive treatment with two coats of hot coal tar and two wraps of hot reinforced fraglan tissues as per IS 10221-1982 and as per hydrostatic testing etc complete all as specified and directed for following sizes:- MS flanged pipe 80mm NB heavy duty for multi storied building duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer all as specified and directed.
250 mm dia (As per IS;3589 AND THICKNESS 6.35 MM)
200 mm dia (As per IS;3589 AND THICKNESS 6.35 MM)
65 mm dia (Nominal bore)
50 mm dia (Nominal bore)
Providing , fabrication and fixing single leaf door with frame onle for all internal fire hydrants fabricated from MS section , welded construction ,having glazed panel with reinforced glass,internal locking arrangement stove enamelled FIRE HOSE written on front , suitable to house 2 nos. 15 m length of canvas hose reel laong with coupling 1 no. branch pipe and 1 no. first aid fire hose reel along with the landing valve all complete size 1300x2100 mm (approx) complete all as specified and directed.
Supply and fix air release valve along with ball valve of length 1.20 meter long dia 150 mm complete including fixing,testing suitable for 150 mm PIPE .
M & L delivery header of MS pipe heavy grade of required length with all fittings ,welding,support etc 250 mm (bore) X 4000 mm ( length) with three nos incomming of 100 mm bore pipe of MS heavy grade and 02 Nos outgoing with 150 mm bore heavy class MS pipe all as specified and directed.
Providing and fixing Y type suction strainer with MS flange connection 200mm dia complete all as specified and directed.
M & L copper conductor of size 1.5 sqmm 2 core armoured control cable on wall or in conduit, complete all as specified and as directed
M & L copper conductor of size 2.5 sqmm 4 core armoured control cable on wall or in conduit, complete all as specified and as directed.
Providing protection of pipe with polythene based coating and wraping system as per manufacturers recommendation including earth work excavation and refilling etc for size of 150 to 250 mm pipe complete in all respects.
Providing protection of pipe with polythene based coating and wraping system as per manufacturers recommendation including earth work excavation and refilling etc for size upto 100 mm pipe complete in all respects.
Providing protection of pipe with polythene based coating and wraping system as per manufacturers recommendation including earth work excavation and refilling etc for 80 mm pipe complete in all respects.
Providing and fixing 6 mm thick orifice plate of brass with central hole of required size as per TAC design having projected identification tag duly marked with K fector complete in all respect for 80/100 mm dia pipes
Providing and fixing wall mounted signages consisting of Zinc sulphate Photo Luminecent coating on acrylic sheet of size 15cmx30 cm and shall consist of signage on half side and arrow on other half. Signage shall be any of the following : Exit/Staircase/Extinguisher Location/Manual call box/Hydarant etc complete all as specified and directed.all as specified and directed.
Providing and fixing of ISI marked (IS:940) portable fire extinguisher Chemical Fire,water (gas pressure) type capacity 9 Ltrs with gun metal cap and nozzle complete with initial fill and wall suspension bracket complete all as specified and directed.
Providing and fixing of ISI marked (IS:13386-1992) mechanical foam type portable fire extinguisher 50 Kg consisting of welded MS trolly mounted cylindrical body ,squeege lever discharge valve fitted with pressure discharge hose ,discharge nozzle,trolly etc finished externally with red enamelled paint and fixed to wall and bracket complete with initial charges all as specified and directed.
Providing and fixing of ISI marked CO2 type portable fire extinguisher 22.5Kg MS trolly mounted cylindrical body ,internal discharge tube,high pressure discharge tube,discharge nozzleas per IS 2878 valve fitted with pressure discharge hose ,discharge nozzle,trolly etc finished externally with red enamelled paint and fixed to wall and bracket complete with initial charges all as specified and directed.
Providing and fixing of ISI marked (IS 2878) portable fire extinguisher carbondioxide type flat base including valves,discharge hose not less than 10 mm dia 1 meter long and complete in all respect including initial fill with CO2 gas confirming to IS;307 1966 filling to filling ratio not more than 0.667 and wall suspension bracket of capacity 4.5 Kg.
Providing and fixing of ISI marked (IS:2878) portable fire extinguisher Mono Ammunium Phosphate (ABC)type of stored pressure type with discharge tube and perssure gauge wall suspension type capacity 5 Kg
Providing and fixing MS structural work fabricated from standard sections i.e. round,solid angle ,slotted angles,chanells including cuttinh to size drilling,welding,fixing and welded to insert plates in RCC structure members all as speccified and directed.
Fire brigade point two way inlet connection at ground level for emergency with with water by fire service appliances etc complete all as specified and directed.
M & L of 2 way fire brigade connection complete all as specified and directed.
M & L of 4 way fire brigade connection complete all as specified and directed.
Providing and fixing weather proof outdoor type hose cabinet made of not less than 1.5 mm CRCA MS sheet having glazed door , locking arrangement , painted with two coats of enamel paint over a caot of primer and size suitable to accommodate 2 nos. 15 meter length 63 mm dia RRL hose pipe and branch pipe for External hydrant.
Providing and fixing of fireman Axe with heavy insulated handle confirming to IS 926 complete all as specified and directed.
Providing and fixing 25 mm dia inspection and testing assembly with ball valve (3 nos.) , gun metal sight glass, by pass valve and connected to drain pipe complete all as specified and directed.
Providing,fixing ,testing and commisioning of resilient rubber lined single arch vibration alemenators suitable for raw water up to 45 degree centrigrade temp. working pressure 7.0 Kg/Sqcm and test pressure 14 Kg/Sqcm for following sizes complete all as specified and directed:-
200 mm dia
150 mm dia
100 mm dia
80 mm dia
Supply and fix 100 watt amplifier all as specified and directed.
Supply and fix control consule all as specified and directed.
Supply and fix loudspeaker cable of size 24/0.2 mm all as specified and directed.
DG SET Supply and install, testing and commissioning of diesel Engine driven generating set of capacity 125 KVA 3 phase, 4 wire, 415 V, 1500 RPM AC power supply with power factor 0.8 coupled directly to alternator mounted on a common base plate complete with integral acoustic enclosures (should have salient features) modular bolted construction, & pure polyester based coating to ensure long life in all weather conditions & for outdoor application / installation, integrated design thereby facilitating / easy handling. The design of integral acoustic enclosure should be approved by National Physical laboratory as per central pollution control board (CPCB) latest regulation /norms (NO x+HC < 4.0, CO < 3.5 ,PM < 0.2 & smoke limit < 0.7 ) with fuel tank, battery & standard accessories, tools & spares as provided by manufacturer complete all as specified and directed. with the following specifications:
(A) ENGINE- Water cooled diesel engine of at 1500 RPM capacity to match the 125 KVA alternator under NTP conditions with provision of 10 % over load for 1 hour in every 12 hours running confirming to BS 5514/ IS 10001/ 10002 the Engine shall consist of the following :- (i) Fly wheel with starter ring (ii) Flexible coupling with guard (iii) Cooling fan (iv) Radiator with guard and water pump engine mounted (v) Dynamo of suitable capacity (vi) Air cleaner heavy duty dry (vii) Fuel injection pump (viii) Radiator fan ( Blower type ) with guard (ix) Pneumatic governor (x) Fuel filter (Mounted) (xi) Lubricating oil filters ( mounted) (xii) 12 volts self regulating alternator belt driven by engine
(xiii) Exhaust silencer heavy duty residential type
(xiv) Corrosion resistor /scale inhibitor
(xv) Starter 12 volts DC
(xvi) Lubricating oil cooler
(xvii) Lubricating oil pump (Gear type )
(xviii) Turbo charger
(xix) Exhaust piping shall be insulated with asbestos rope duly cladded with aluminium sheet.
(xx) Instrument panel complete with :-
(a) Auto manual Starting switch with key
(b) Lubricating oil temperature gauge
(c) Lubricating oil pressure gauge
(d) Water temperature gauge
(e) Battery charging ammeter
(f) Battery charging indicating lamp
(g) Hour meter with RPM indicator
(h) Safety control against high temperature of water.
(j) Safety control against low lubricating oil pressure .
(k) Over speed stop with double driven adopter .
(B) BRUSH LESS ALTERNATOR
(i) Alternator coupled to engine indigenous make through a flexible coupling mounted on sturdy steel fabricated base frame suitable for mounting on a permanent foundation brushless alternator shall be confirming to BS -2613 or relevant of IS-4722/ IS 13364
(ii) Type :- Self excited self regulated with automatic voltage regulator
(iii) Rating :- 125 KVA at 0.8 PF lagging 4 pole horizontal at NTP condition .
(iv) Speed;- 1500 RPM
(v) System :- 415 V +/- 2.5 % AC 3 phase 4 wire 50 Hz.
(vi) Connection :- 4 wire star connected .
(vii) Enclosure ;- Screen protected drip proof .
(viii) Ventilation :- Self ventilated.
(ix) Insulation :- Insulation class H
(C) CONTROL PANEL
The control panel with aluminium bas bar, bottom entry and exit of cable, current transformer, set of control fuses, Multifunctional Meter, it should display time and date, Volts, Frequency, Current, KW, KWH, PF, RPM, Cumulative Run Hours, Oil Pressure, Coolant Temp, Charging current (DC Amp Meter). Emergency off, factory made floor mounted, totally enclosed, epoxy powder coated suitable for 125 KVA DG Set including all necessary operating controlled devices as stated above and MCCBs as out going with protection fuse for panel instruments duly wired with flexible copper conductor cable and cable connection with lugs/thimbles complete as per latest IS/BS and all as specified and directed.
(D) ONE SET OF ACCESSORIES COMPRISING OF :-
(a) Fuel tank -one No. fabricated with 3 mm thick MS sheet with necessary mild steel structure for mounting the tank higher than the DG set) with piping. Capacity of tank shall be to hold diesel sufficient for 16 hours running at full load, with following features
(i) Level indicator.
(ii) drain plug .
(iii) MS class 'C' piping for inlet from pump to tank to engine.
(iv) Fuel strainer.
(v) Air vent.
(b) FUEL PUMP :-
Electrical operated fuel pump for filling diesel in the tank of adequate capacity with inlet connection to the tank with 5 meter flexible hose pipe heavy duty for suction of diesel from barrel.
(c) Sealed maintenance free Battery :-
Heavy duty battery 24 plates 12 v 180 AH (1 Nos) connected to the system fully charged including lead and bty terminal's complete .
(q) DC Voltmeter 15/30 volts-01 No. (r) Trickle / boost swich-01 No. (s) Auto/manual switch- 01 No. (t) Start and stop push button- 02 Nos. (u) Audio annunciation for:- i) High water temperature ii) Low lubricating oil pressure iii)Engine over speed iv)Engine fails to start v) Full load/maximum load warning (v) Overload relay 3-5 A- 02 Nos. (w) Contol relay - 02 nOs. (x) 1 No. M.V danger notice plate of 200 mm X 150 mm made of mild steel, at least 2.00 mm thick and painted white and inscription in signal red colour on front side.
LIFT Design, Supply ,install, tesing and commissioning of eletrically operated passenger lift of capacity 8 passenger lift (544 kgs Capacity) in the existing lift well, 1.5 m/s speed with automatic GIEN micro stroke button control, microprocessor based controller, simplex full collective control suitable for 3 phase, 50 HZ 415 volts AC supply independent operation with AC variable voltage variable frequency(AC VVVF) control closed loop with power saving regenerative drive with suitable motor and gear unit to serve ground plus Thirteen upper floors i.e with 14 stops and 14 landings with or with out attendent suitable for synchronised operation automatic power operated centre opening sliding stainless steel door with Moon Rock finish of 16 gauge (not less than 1.5mm) with infra-red sensors all along the height for car door with automatic rescue/levelling device (ARD) (with + or -5 mm) with suitable dry maintenance free batteries,haul position digital indicators in car and all landing with call indicating lights etc including necessary joists and beams for mounting machine in the machine room including all civil works required in connection with erection of lifts complete all as specified. The lift shall be provided with and including the following : (Size of well available is 2100 mm x 1800 mm ) Type of Drive: Regenerated AC variable voltage and variable frequency drive along with converter unit.The regenerated power shall be used to charge the battery of UPS,ARD and emergency lights. Type of Machine: Gearless permanent magnet and directly coupled to horizontal traction machine. Note 1: Counter weight shall be of cast iron block.
(a) Fire man switch. (b) Automatic rescue device (A.R.D) during power failure including manual operation provision with suitable capacity of battery designed for running the lift with full load. (c) Separate Battery operated emergency light (LED ceiling fitting ), alarm (speaker for emergency alarm system to be fixed) and stop button in car with rechargeable arrangement for battery. (This system shall be separate from ARD batteries.)
(d) Integrated Roof RL20 Stainless Steel Ring Lighting LED (e) One sleek circular PVC heavy duty fan in false ceiling. Make for (c) and (d) : Philips/ Bajaj / Havells / Crompton Greaves. (f) Aluminium chequered plate (3mm thick) as flooring joint in chequered plate should not more than one and top covering with 20 mm Recess & Granite Stone.Car skirting material: Brushed stainless SUS304 (g) Non stop button /independent operation (h) Over load warning indicator both audio and visual type with tripping system having relays etc (overload protection/tripping system). (j) Front landing door of stainless steel moon rock finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds. (k) Car size shall be in confirmity with IS -3534-1976 and body to be stainless steel of 16 gauge moon rock finish with stainless steel hand rail 38mm hairline finish (l) Limit switches as specified in IS
(m) Mirror of 6mm thickness of suitable size. (n) Hand rail 38mm hairline finish. (o) Opening with see through glass of 8 mm thick 200 x 600 mm size in all the doors (Car/Landing doors) (p) Specification plate with complete details. (q) Continuous earthing for machine and equipments. (r) Steel Wire rope of adequate size as per relevent IS and as per manufacturer specification
(s) Other standard fixtures and fittings like guide rails, sheaves, counter weights with guards ,buffers, gear unit brakes, control panel ,locks ,governor ,car operational panel,power, control and trailing cables complete. (t) Car operating Panel 1 Full Height Dark grey brushed StSt Tempering glass Segmented LCD display Round flush mounted KDS96 – stylish touch panel Landing Signalization-Tempered glass Segmented LCD display Flush Mounted Tempered glass Round flush mounted KDS96- stylish touch panel (u) Main drives and control shall be of latest , high effective and low power consumption. (v) Suitable phase reversal relay shall be provided on the controller to protect lift/equipment against phase reversal, phase failure and low voltage. (w) Over load and floor announcement audio and visual arrangement.
Features Common to Specifications 1. Digital Direction & Position Indicator in Car and at all landings 2. Emergency Alarm at the main landing 3. Facia Plate 4. 2 Phase Fireman Drive, Fireman’s switch at the main landing. (In case Fireman Drive is activated the elevator will come to the main landing and open the door). 5. Advanced door operation (Ensures smooth opening & closing of the doors at adjustable door speed) 6. Additional Pressure Sensing Device 7. Load Weighing Device (Audio visual over load indicator in the car for better safety) 8. Full Height Infra-Red Curtain 9. Pit Ladder 10. Emergency Light, Intercom and Alarm with Maintenance Free Rechargeable Battery operation.
11. +6% To-10% Volt. Fluctuation Withstand Capacity 12. Over speed governor (Electro-mechanical device that prevents free fall in case the elevator is travelling at speed more than 10% of the rated speed in downward direction) 13. Automatic Rescue Device (To rescue the passengers in case of emergency- this device will bring the car to the nearest floor automatically and will open the doors). 14. Steel Ropes 15. Special Car Door Lock 16. Fire Rated Doors-2 hour. 17. Automatic Brake Testing. 18. PMS MOTOR with ECO Disk Drive 19. Linear Motor Technology & Close Loop Arrangement. 20. 24x7 Connected Services. 21. Car & Landing Doors –Moon rock finish
Design, Supply ,install, tesing and commissioning of eletrically operated passenger lift of capacity 13 passenger lift (844 kgs Capacity) in the existing lift well, 1.5 m/s speed with automatic GIEN micro stroke button control, microprocessor based controller, simplex full collective control suitable for 3 phase, 50 HZ 415 volts AC supply independent operation with AC variable voltage variable frequency(AC VVVF) control closed loop with power saving regenerative drive with suitable motor and gear unit to serve ground plus thirteen upper floors i.e with 14 stops and 14 landings with or with out attendent suitable for synchronised operation automatic power operated centre opening sliding stainless steel door with Moon rock finish of 16 gauge (not less than 1.5 mm) with infra-red sensors all along the height for car door with automatic rescue/levelling device (ARD) (with + or -5 mm) with suitable dry maintenance free batteries,haul position digital indicators in car and all landing with call indicating lights etc including necessary joists and beams for mounting machine in the machine room including all civil works required in connection with erection of lifts complete all as specified. The lift shall be provided with and including the following : (Size of well available is 2100 mm x 1800 mm ) Type of Drive: Regenerated AC variable voltage and variable frequency drive along with converter unit.The regenerated power shall be used to charge the battery of UPS,ARD and emergency lights. Type of Machine: Gearless permanent magnet and directly coupled to horizontal traction machine. Note 1: Counter weight shall be of cast iron block.
(a) Fire man switch. (b) Automatic rescue device (A.R.D) during power failure including manual operation provision with suitable capacity of battery designed for running the lift with full load. (c) Separate battery operated emergency light (LED ceiling fitting ), alarm (speaker for emrgency alarm system to be fixed) and stop buttion in car with rechargeable arrangement for battery . ( This system shall be separate from ARD batteries.)
(d) Integrated Roof RL20 Stainless Steel Ring Lighting LED (e) One sleek circular PVC heavy duty fan in false ceiling. Make for (c) and (d) : Philips/ Bajaj / Havells / Crompton Greaves. (f) Aluminium chequered plate (3mm thick) as flooring joint in chequered plate should not more than one and top covering with 20 mm Recess & Granite Stone.Car skirting material: Brushed stainless SUS304 (g) Non stop button /independent operation (h) Over load warning indicator both audio and visual type with tripping system having relays etc (overload protection/tripping system). (j) Front landing door of stainless steel moon rock finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds. (k) Car size shall be in confirmity with IS -3534-1976 and body to be stainless steel of 16 gauge moon rock finish with stainless steel hand rail 38mm hairline finish (l) Limit switches as specified in IS
(m) Mirror of 6mm thickness of suitable size. (n) Hand rail 38mm hairline finish. (o) Opening with see through glass of 8 mm thick 200 x 600 mm size in all the doors (Car/Landing doors) (p) Specification plate with complete details. (q) Continuous earthing for machine and equipments. (r) Steel Wire rope of adequate size as per relevent IS and as per manufacturer specification
(s) Other standard fixtures and fittings like guide rails, sheaves, counter weights with guards ,buffers, gear unit brakes, control panel ,locks ,governor ,car operational panel,power, control and trailing cables complete. (t) Car operating Panel 1 Full Height Dark grey brushed StSt Tempering glass Segmented LCD display Round flush mounted KDS96 – stylish touch panel Landing Signalization-Tempered glass Segmented LCD display Flush Mounted Tempered glass Round flush mounted KDS96- stylish touch panel (u) Main drives and control shall be of latest , high effective and low power consumption. (v) Suitable phase reversal relay shall be provided on the controller to protect lift/equipment against phase reversal, phase failure and low voltage. (w) Over load and floor announcement audio and visual arrangement.
Features Common to Specifications 1. Digital Direction & Position Indicator in Car and at all landings 2. Emergency Alarm at the main landing 3. Facia Plate 4. 2 Phase Fireman Drive, Fireman’s switch at the main landing. (In case Fireman Drive is activated the elevator will come to the main landing and open the door). 5. Advanced door operation (Ensures smooth opening & closing of the doors at adjustable door speed) 6. Additional Pressure Sensing Device 7. Load Weighing Device (Audio visual over load indicator in the car for better safety) 8. Full Height Infra-Red Curtain 9. Pit Ladder 10. Emergency Light, Intercom and Alarm with Maintenance Free Rechargeable Battery operation.
11. +6% To-10% Volt. Fluctuation Withstand Capacity 12. Over speed governor (Electro-mechanical device that prevents free fall in case the elevator is travelling at speed more than 10% of the rated speed in downward direction) 13. Automatic Rescue Device (To rescue the passengers in case of emergency- this device will bring the car to the nearest floor automatically and will open the doors). 14. Steel Ropes 15. Special Car Door Lock 16. Fire Rated Doors-2 hour. 17. Automatic Brake Testing. 18. PMS MOTOR with ECO Disk Drive 19. Linear Motor Technology & Close Loop Arrangement. 20. 24x7 Connected Services. 21. Car & Landing Doors – Moon Rock Finish
TV CABLE S&F TV cable co axial complete all as specified and directed.
S&F TV sockets any type complete all as specified and directed.
ELECTRIC METER Supply and Installation of RF /Sim based Smart Single Phase Meter with the following specifications: • AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC standards with inbuilt 865-867 MHz Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry. • Meter Should support sending the the following data to the software : 15/30 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, monthly billing survey for Cumulative Energy and Max Demand • Meter should have connect / disconnect functionality operable from prepaid billing software • The meter should support open communication protocol DLMS with the software MAKE: Secure, L&T, Schneider Note: (a It would be possible to run the meter in both prepaid and postpaid mode (b) The meters would carry 5 year warranty..
Supply and Installation of IP-67 protection Data Concentrator Units (DCU) compatible for remote Automatic Metering Infrastructure (AMI) solution and capable of communicating with the smart energy Meter in the corresponding frequency band and with the data server through GPRS/Ethernet. It would have internal memory to store data of at least 200 modules. It would have inbuilt battery back-up. It would have IP-67 protection. It would support auto discovery of the meters and self healing mechanism for the breaks in the RF network. Make: Secure, L&T, Schneider, CyanConnode
Supply and Installation of single phase meter (Dummy meter in case of poor/No signal) as repeaters.
Supply and Configuration of the Web based Software with following modules: (i) Meter Data Management Module The meter data management module would be responsible for collecting the data from the concentrator and make the data available to the billing system. The meter data management system would capture and provide the following data: (a) 30 min instantaneous data from all the meters for seven parameters – Cumulative Energy, Cumulative Apparent Energy (as applicable), Power, Current, Voltage, Power Factor and Frequency (b) Monthly billing survey data for cum energy and max demand (ii) Postpaid /Prepaid Billing Module The billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data / billing data available to admin and end users. The billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. It would allow postpaid and prepaid functionality as required. (iii) Occupation and Vacation Module The system would support occupation / vacation and billing reports. the software would be collecting data from DCU. The software would provide access to staff as well as the occupant for the data. (iv) Web site: There would be a dedicated website for the AGE and BSO team to view all the data and information. The designated users in MES would have the admin access to the application. The MES staff would also have the access of the key information on an android mobiles app (for admin use). (v) Customer Portal
The system would include a customer portal for the resident /occupant to log in and view their own energy / billing data. There would be android and iOS mobile apps for the user to monitor its own data and balance on regular basis. (vi) Energy Accounting Module The system would include features of energy accounting. The system would be able to account for total energy block wise, facility wise and would also allow calculations of unaccounted energy in case total energy meter is also available. (vii) Communication Module The system would provide communication of energy data and bills via print, email and sms methods. (viii) Meter Master Data The system would support meter master data repository. The system would support meter replacement process. (ix) Excel Export The system would support export of metering and billing data in excel format. (x) Customer Care Module - the software would include a customer care module where the user would be log in any complaints. The service provider would monitor the complaints and carry out the necessary activities for the complaints resolution. (xi) Meter Installation Module - The software would include an app based meter installation module where the meter installation or changes can be captured on the app itself and the readings may be demonstrated to the user if required on the app itself. (xii) Activities Communication - The software support communication of the various activities such as occupation, vacation, meter change. personal detail change etc. with the user as well as the department on email.
Make: Schneider, Innologix, SAP Note: (a) The software would be hosted either on GCC Server or on MES Server. In case the software is hosted on GCC Server, it would be transferred to MES server whenever the same is made available. (b) The software would contain two year defect liability including all operating expenses such as GPRS charges, hosting charges etc. (c) GE Bank account and one payment gateway would be provided by MES. The payment gateway would be integrated with the software.
Supply and fix Meter box for single phase energy meter of inner dimension not less than 295 mm x 255 mm x 120 mm complete including flushed to wall all as specified and directed.
STP (SEWAGE TREATMENT PLANT) Designing, Supply, installation, testing and commssioning of package type Sewage Treatment Plant of capacity 100 KLD including all civil works, treated water tank, electrical and mechanical works for STP having following input and output parameters: (a) Inlet Parameter (i) BOD - 200 mg/ltr (ii) COD - 450 mg/ltr (iii) TSS - 250-300 mg/ltr (iv) Oil & Grease - 20-30 mg/ltr (v) PH - 6 to 9 (vi) Coliform - 1 x 10 6 MPN/100ML (vii) Temp- 20 Degree Centigrade (viii) TKN - 45 (b) outlet parameter of sewage treated water are as follows : (i) BOD < 10 mg/ltr (ii) COD < 50 mg/ltr (iii) TSS < 10 mg/ltr (iv) Oil & Grease < 10 mg/ltr (v) PH - 6.5 to 8.5 (vi) Coliform - 1000 MPN/100ML (vii) Residual Chlorine - > 0.5 mg/ltr (viii). TKN < 10 mg/Ltrs (ix). Phosphours < 1 mg/Ltrs Notes :- All Design parameters and specifications are as per Annexure "I" .
Supply , install , testing and commissioing Non clog vertical submersible pumps Duty (Flow and head) 140 LPM, 12 Mtr head of 3 Phase, 415 V, Max solid size 35 MM with chrome steel impeller , including Supply, installation HDPE discharge Pipe upto header Appx 10 Mtr.of suitable dia as per OEM recoomendation and SS 306 lifting chain 10 Mtr length, water proof Control and power cables Appx 10 Mtr, Control and power panel for pump as supplied by OEM, , Necessary Support ,clamps and rubber gaskets and SS Nut bolts as suggested by OEM all as specified and directed PUMP CASING The radially split casing is provided with delivery nozzle cast integral with it. Suction is axial and delivery nozzle is central and horizontal .Specially designed semi-concentric casing results in reduced radial thrust and ensures vibration-free performance. Wide volute passage ensures non-clogging operation of the pump. IMPELLER Impellers are of non-clog type which allow smooth passage of solids .Impellers are with single or multi vanes in semi-open, enclosed, or free flow designs to cater to wide applications.
SHAFT The high tensile steel shaft accurately machined and ground is supported by two ball bearings in the motor above the impeller. Shaft is designed to transmit the power without undue vibrations and deflections. The shaft is common for pump and motor of monoblock design. MECHANICAL SEALS Two mechanical seals in tandem arrangement are provided to ensure no ingress of water or sewage in motor. BEARINGS Bearings are grease lubricated and sealed for life, hence maintenance free. DRIVE Motor is dry type submersible and cooled by liquid being handled. Motors are air tested for leakfree operation. Degree of protection for motor is IP68 as per IS:2147 Class of insulation : F Voltage : 415V 10% Frequency : 50 Hz. 5% CABLE A specially designed cable, 1.1 kV grade having annealed tinned copper conductor, insulated with Electron Beam Irradiated crosslinked elastomeric compound (compatible for continuous operation at 1200 C) cores laid up with a proof cotton binder tape and sheathed overall with Electron Beam Irradiated Cross-linked HD HOFR elastomeric compound and generally conforming to IS 9968 Part l. The cable with this unique combination of insulating and sheathing material offers best resistance to acidic or alkaline sewage medium and to the effluent gases coming out of the sump. The cable is more flexible than PVC cable making coiling and handling easier and light in weight compared to PVC cable of the same size.
FLANGES Standard drilling to IS 6392 table 15. Out door type CONTROL PANEL Control panel consists of suitable capacity of starter as per OEM recommendation , MCCB,Multifunction digital meter and safety features. Safety features are: Single phasing prevention Overload relays Moisture sensing unit for detecting ingress of moisture or water into oil chamber. Liquid level controllers to avoid dry running. Under voltage / Reverse phasing
S &F 6 sqmm multistranded copper conductor, 3 core PVC insulated and sheathed copper screen protected 1100 Volts grade submersible flat cable fixed to non clog submersible pump upto panel/starter with suitable clamps & jointing material complete all as specified and directed. .
Supply,install,testing and commisioning of openwell submersible pump set electric driven 3 phase 415 Volts 50 Hz 2900 RPM having head not less than 60 meter and discharge not less than 18 Cum/Hr having cast iron cashing, cast iron impeller,stainless steel C40 shaft, Bronze shaft sleeve complete including provision of necessary foundation of pump set including CPVC pipe heavy grade from delievery side of pump to discharge header with connected flanges,nut bolts,gasket etc. including necessary foundation work and other associated work complete with provision of following all as specified and directed:- (a) Common base plate for motor and pump set-01 No. (b) Suitable gun metal strainer as directed and recommended by manufaturer. (c) CPVC pipe heavy grade from delievery side of pump to discharge header with connected flanges,nut bolts,gasket etc. (d) Suitable size copper cable from motor to starter. (e) Suitable size Non return valve recommended by manufaturer. (f) Suitable size cast iron foot valve recommended by manufaturer. (g) Suitable size sluice valve on discarge side recommended by manufaturer.
Supply and fixing of 5000 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet connection with necessary nipple, over flow pipe , provision of wash out pipe, brass ball valve high pressure with polyethylene float and fly nut complete screwed for iron pipe or brass ferruls complete including fittings all as specified and directed.
Supply and fix CABLOFIL wire meshed Hot dip Galvanized cable tray 54 mm (h) x 100 mm (w) complete with nuts bolts washers (GI) and all accessories (for mounting/fixing on building rising mains) and supporting the cable tray system, along with vertical bends complete all as specified and directed.. Make : Legrand/Siemens/Panduit
Supply, installation, testing and commissioning of ultra sonic level sensor with following specifications: Rust proff, Maintenance free suitable for up to 6 meter water level depth of OHTS/ U/G sump, with dead band of less than 0.6meter, IP67 protection, accuracy of 0.25% of F.S. and 4-20mA current output, No of wires: 4 wire, Beam angle: less than 7.5 degree, Capable for working in ambient temperature of 0 degree Centigrade to 75 degree Centigrade, non-condensing at 25 degree Centigrade and humidity up to 95% with response time of less than 1 sec with 230VAC to 24VDC, 50Hz power supply, Non display type, in built temperaure & voltage variation compensation, vertical type mounting on top of OHTS/ Sump, suitable for measuring water/ waste water in Sump /OHT, with all connections and fixing including clamp. nut-bolt etc complete all as specified and as directed. Make ABB, Endress+Hauser Mgt, Siemens, Krohne, Pepperl+Fuchs, continental, Vega grieshaber, Hans Turck, Gems sensors, Omega engineering, Keyence, Texas instruments, Migatron, honeywell. (Scope of work include all accesories required for the correct operation of the sensor)
Supply, installation, testing, commissioning and calibration CE and UL approved manufacturer's smart energy meter with memory/real time clock having CI 0.5 accuracy & Modbus/RTU communication over RS 485 and 1 serial port integrated with RTU as per specs mentioned in technical bid documents
Supply, Installation Testing & Commissioning of indoor type PLC ( Programmable Logic Controller) /RTU (Remote terminal Unit) based Automation, Protection Panel for lift well/sewage pumping installation with feature of Dual mode communication i.e. wireless Dual SIM Card based communication and wireless Radio Frequency based communication (The module should be programmed to automatically toggle between the two communication mode based on the actual signal strength available), suitable for control and monitoring of upto 4 Nos pumps with electrical parameters, 1No Energy meter, 1 No electromagnetic flow meter with totalizer & 1 No ultrasonic level sensor The panel shall be 500 x 800x 300 MM front opening type as per MES enclosure guideline as per given specification:- (1) The Panel should be capable of performing following functions in Liftwell all as specified and directed:- (a) time & level based operation of lift well. (b) online monitoring of electromagnetic flow meter parameters & energy consumption pumps in desired format
c) Automatic Operation of Motor Actuated Butterfly Valves /DO sensors! compressors, etc (if required) (d) Automatic duty cycle based operations of Pumps (e) Auto Change Over In Case of Pump Failure (1) Single Phasing Prevention, phase sequence corrector, voltage unbalancing protection (g) Manual Mode Operationof pumps (all connected sub systems & operations in Sewage treatment plant) from the PLC/ RTU based Control Panel. (i) the panel shall have 01 No. PLC/ RTU with following specifications:- (a). Discrete Input Logic (b). Should have suitable No. of Discrete Input and Discrete Output:- Relay/Transistor (c). Protocol supported: isolated serial/ TCP link: Modbus master/slave and DNP 3.0
ARBORICULTURE Supply of fine sand at site including royalty and carriage for preparing compost at site (sand shall be brought at site and stacked for measurment before incorporating in the work) complete all as specified and directed.
Supply only sweet/good earth at site including royalty and carriage for preparing compost for pits/required for planting trees and shrubs etc (sweet/good earth free from objectionable extraneous matter, toxic material and termites shall be brought at site and stacked for measurment before incorporating in the work 20% of computed volume shall be reduced for loose stacking complete all as specified and directed.
Supply only manure at site inculding royalty and carriage for prepaing compost at site (manure shalll be brought at site and stacked for measurement before incorporating in the work 8% computed volume shall be reduced for loose stacking complete all as specified and directed.
Preparing compost pits of size 600 x 600 x 600 mm by excavation in ordinary soil, applying and termite treatment, planting tree & refilling of the pit with compost (manure, sand & sweet earth) mixed in ratio (1:1:4) breaking colds, ramming and flooding with water filling with more compost if necessary and fine dressing including removal of rubbish unserviceable materials & surplus soil to a distance n.exe100mtr. ATT shall be uniform of 200 gms neem cake mixed 2 ml per litre in the first watering of 20 liters per pit complete all as specified and directed.
Preparing compost pits of size 900 x 900 x 900 by excavation in ordinary soil , applying and termite treatment, planting the tree & refilling of pit with compost (manure sand & sweet earth mixed in ratio 1:1:4) breaking clods, ramming and flooding with water with more compost if necessary and fine dressing including removal of rubbish unserviceble lnaterials and surplus soil to a distance n.exe 100mtr ATT shall be in form of 200gms neem cake mixed with every Cum of compost followed by Dussban or equivalent applied at 2 ml Pee litre in the first watering of 20 litrs per pits complete all as specified and directed.
Supply & Planting following trees/ shrubs/ plants/ hedge in location as shown on drawing and as specified & directed by Engineer-in-Charge including preparing of composit pit of required size(1.20m x1.20m x1.20m or 0.45m x0.45m 0.45m) as per required size in any type of soil applying anti termite treatment, refilling the pit with compost (manure, sand & sweet earth mixed in ratio of 1:1:4) breaking clods, ramming, & flooding with water filling fine dressing & removal of rubbish, unserviceable materials & surplus earth complete all as specified & directed by Engr-in Charge. NOTE-1. ATT shall be in form of 200gm neem cake mixed with one cum of compost followed by Dursban applied @2ml per litre in first watering of 30 litre per pit, NOTE-2. Rates for following items includes supply and application of manure / sweet earth ,ATT chemicals, sand, fertilisers etc complete all as specified and directed.. :-
Dwarf Gulmohar (i) Spacing @ 10 to 15 feet (ii) Height : 5 feet, Girth : 8 to 12 cm, Pit Size :(1.20m x 1.20m ) complete all as specified and directed.
Bougainvilla (i) Spacing @ 08 to 10 feet (ii) Height : 5 feet, Girth : 8 to 12 cm, Pit Size :(1.20m x 1.20m ) complete all as specified and directed.
Champa (i) Spacing @ 08 to 10 feet (ii) Height : 5 feet,Girth : 02 to 04 cm, Pit Siz :(0.45m x 0.45m) complete all as specified and directed.
Guava tree (i) Spacing @ 08 to 10 feet (ii) Height : 5 feet, Girth : 8 to 12 cm, Pit Siz :(1.20m x 1.20m ) complete all as specified and directed.
Silver Oak (i) Spacing @ 08 to 10 feet (ii) Height : 5 feet, Girth : 8 to 12 cm, Pit Siz :(1.20m x 1.20m ) complete all as specified and directed.
Ashoka Pandula tree (i) Spacing @ 10 to 15 feet (ii) Height : 5 feet, Girth : 8 to 12 cm, Pit Siz :(0.45m x 0.45m ) complete all as specified and directed.
Bottal brush (i) Spacing @ 05 to 10 feet (ii) Height : 5 feet, Girth : 8 to 12 cm, Pit Siz :(0.45m x 0.45m ) complete all as specified and directed.
MANURE:- Old cow dung or okhla sludge @ 2.25 cub foot for 10 Sqm
FERTILIZERS :-
(i) Neem Khali @2Kg for 10 Sqm
(ii) Seomeal @1Kg for 10 Sqm
(iii) D.A.(16.42) @ 0.15Kg for 10 Sqm
(iv) BHC dust 10% or lindance dust @ 0.15Kg for 10 Sqm
(v) Fine dressing a top soil after mixing the manure and fertilizers to requisited slope
(vi) watering the area for fine dressing of soil after one week till the soil get water upto root zone depth
(vii) Fine dressing a top soil to requisited slope & gradients towards the manholes.
(viii) Plantation of grass @ 10cm on both way by dibbing root method.
COMPREHENSIVE MAINTENANCE OF LIFT Comprehensive mainenance of electrically operated passenger lifts (4 Nos) 8 passenger lift (544 Kgs) & electrically operated passenger lifts (2 Nos) 13 passenger lift (884 Kgs) installed under item No. 41 & 42 & of BOQ under Sch 'A' part -XX (Miscellaneous) complete including attending the following services to lifts all as mentioned vide Notes mentioned below and as specifed in PS including (A) FORTNIGHTLY MAINTENANCE, (B) MONTHLY MAINTENANCE (C) QUARTERLY MAINTENANCE (D) HALF YEARLY /YEARLY MAINTENANCE including MOU complete all as specified and directed for :-First year after expiry of defects liability period Note:- Execution of this item shall be commenced immediately after expiry of defect liability period (i.e. 24 Months after the date of satisfactory completion of Ph-I
All as per item No. 22.24 here-in-before but for 4th year
All as per item No. 22.24 here-in-before but for 5th year
Notes for item No 22.24 to 22.26 are as under :- (i) Comprehensive maintenance consists of preventive and breakdown services including repair and replacment of all consumables like topping of gear oils/grease/door rollers/relays/contactors/door belts/gate lock/contacts/PCB's and any hardware including rewinding of motor etc and load testing of lift for satisfactory performance once in a year complete and rate quoted by the tenderer includes the following
(ii) Preventive maintaince consists of carrying out routine check by skilled personnel deputed by OEM as specified in Particular specifications and as recommended by Engineer-in-Charge and lubricating to all moving parts,topping up of oils as per Lubrication chart.
(iii) Breakdown maintaince consists of attending to the faults that may occur and carrying out necessary repairs/replacement to electrical control circuits and electrical/mechanical components of the lift that may occur during the operation.
(iv) Fortnightly,monthly,quarterly,halfyearly and yearly maintaince registeres shall be maintained and signed by site engineer and contractor.
(v) Load testing shall be arranged by the contractor to the Lift for whose repairs were carried out as and when directed.
(vi) Any delay in attending breakdown will attract penalty @ Rs 500 for first 8 to 16 Hrs after receiving complain and @Rs 1500 for every 24 Hrs of delay in rectification of complain.
(vii) Payment will be released only after successull completion of maintenance as per schedule described here in before and submission of record signed by all concern persons
Note-2 The contracto has to submit the AMC agreement with the OEM before the completion defect liability period for commencement of Phase- II
MANNING & OPERATION OF LIFT Manning and Operation of electrically operated passenger lifts (4 Nos) 8 passenger lift (544 Kgs) & electrically operated passenger lifts (2 Nos) 13 passenger lift (884 Kgs) installed under item No. 41 & 42 & of BOQ under Sch 'A' part -XX (Miscellaneous), for the duration of 24 hours in 03 (Three) shifts including sunday and holiday and including Reliver For:- (a) Ist Shift from 0600 Hrs to 1400 Hrs, (b) IInd shift from 1400 Hrs to 2200 Hrs and (c ) IIIrd shift from 2200 Hrs to 0600 Hrs per day (with deploying one well experienced operator in each shift) Note :- Execution of this item shall be commenced after satisfactorly completion of Phase-I
Keeping in view the emergency services of lift work the following points shall be noted as mandatory requirement to the tendror for the subject work :-
(i) The contractor has to make necessary arrangement for undergoing oprators training enabling them to be well versed with rescue opration of trapped person and other lift safety mechanism. The training is required to be given by the OEM.
(ii) All the training certificate of the operators shall be submitted to the Engr in Charge prior to the deployment in the work, it may be noted that it is sole responsibility of the contractor if any miss happening occurs including accident/ Injury due to deployment of inexperienced/ unskilled persons. Nothing shall be admissible from the department.
(iv) The contractor shall provide the service of personnel's, duly trained by the OEM, necessary certificate from OEM to be enclosed.
(viii) Contribution towards Bonus that the amount is payable only after submission of valid and authentic document in support of having paid the requisite amount of bonus to the workmen, ie proof of payment similarilly items /sub items of contribution towards EPF and contribution towards ESIC shall also be payable after submission of valid & authentic document in support of proof of payment.
(ix) If Lift operatore found absent during duty hrs following penalties will be imposed and deducted from payment to the contractors ;- (i) Rs 500/- for absentees of 02 hours to 04 hrs per shift. (ii) Rs 1000/- for absenty more than 04 hrs per shift.
All as per item No. 22.35 here-in-before but for 2nd year
All as per item No. 22.35 here-in-before but for 3rd year
All as per item No. 22.35 here-in-before but for 4th year
All as per item No. 22.35 here-in-before but for 5th year
Manning and Operation of Sewage treatment plant having capacity 100 Cubic meter/day installed under item No. 21.84 of BOQ under Sch 'A' part XX (Miscellanous Items), for the duration of 24 hours in 03 (Three) shifts including sunday and holidays and including necessary reliver For (i) Ist Shift from 0600 Hrs to 1400 Hrs, (ii) IInd shift from 1400 Hrs to 2200 Hrs and (iii) IIIrd shift from 2200 Hrs to 0600 Hrs per day (with deploying one well experienced operator in each shift) for Ist year from next date of certified date of completion all as specified and directed. Note : Execution of this item shall be commenced after satisfactorly completion of Phase-I (ii) Water and Electric required for operation of plant shall be provided free of cost by the Department. (iii) All Consumable such as Sodium Hypochlorite and any other chemical required, compressure oil and grease etc required for operation of plant shall be provided by contractor at his own cost as per the manufacturer's instruction and direction of AGE (I) during the period of manning & Operation, cost of the same shall be deemed included in the unit rates quoted by contractor. (iv) Please ensure that all trade men engaged in subject work covered in EPF scheme. Proper doc should be maintained in this regard and submitted alongwith each payment.
All as per item No. 22.50 here-in-before but for 2nd year
All as per item No.22.50 here-in-before but for 3rd year
All as per item No.22.50 here-in-before but for 4th year
All as per item No. 22.50 here-in-before but for 5th year
M/s Highway Construction
GUPTA ENGINEERS AND CONTRACTOR
MANGLA AMIT BUILDERS PVT LTD
SOOD ASSOCIATES PVT LTD
BHARATSHAH CONSTRUCTION CO
Ktech Engineer Builders Co. Pvt. Ltd
Bahl Builders Pvt Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid