Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.0 LAccepted-AOC | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹37.6 L+₹1.0 L (2.80%)Rejected-Finance 13 218 MASJID EXTEN SADAR BAZAR | L2 | Rejected-Finance Not the lowest tenderer | |
| 3 | L3₹37.7 L+₹1.1 L (3.14%)Rejected-Finance | L3 | Rejected-Finance Not the lowest tenderer | |
| 4 | L4₹39.8 L+₹3.2 L (8.83%)Rejected-Finance | L4 | Rejected-Finance Not the lowest tenderer | |
| 5 | L5₹40.2 L+₹3.7 L (10.1%)Rejected-Finance H NO 82 C BLOCK NO CC SHALIMAR BAGH DELHI 110088 | DELHI | NORTH DELHI | DELHI | 110088 | L5 | Rejected-Finance Not the lowest tenderer |
Tender Value
₹43.8 L
EMD Value
₹87,620
Closing Date
29 Dec 2021, 6:00 pmClosed
Garrison Engineer South Delhi Cantt 110010
Delhi Cantt 110010
SPECIAL REPAIR TO TOILET AND BATHROOMS IN BLDG NO P-54 AND P-55 (OR LIVING) AT 10 JAK LI AND OTHER CERTAIN SANCTIONED WORKS AT OFFICE COMPLEX AT 12 GASL VIKRAM VIHAR AND 227 FD WKSP COY EME UNDER AGE B/R-I (S) AND AGE E/M (S) OF GE (SOUTH) DELHI CANT
2021_MES_491819_1
GE/DS-73/2021-22
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer South Delhi Cantt 110010
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
Yes
Garrison Engineer South Delhi Cantt 110010
₹87,620
Yes
24 Jan 2022
1 Dec 2021
31 Dec 2021
1 Dec 2021
29 Dec 2021
15 Dec 2021
2 Dec 2021 - 13 Dec 2021
Amount
B/R Works Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) and removing from site complete all as specified and directed by Engineer-in-charge.
Demolition of cement concrete (unreinforced) of any description and in any position as in bed and removing from site complete all as specified and directed by Engineer-in-charge.
Demolition of brick work built in cement mortar of any description complete all as specified and directed by Engineer-in-charge.
M&L for brick work with sub class 'B' Bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 as in manholes complete all as specified and directed by Engineer-in-charge.
M&L for brick work with sub class 'B' Bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed by Engineer-in-charge.
Demolition of stone slabs and tiles of any description or thickness in floors and aprons etc. laid, bedded and pointed in any mortar complete all as specified and directed by Engineer-in-charge.
M&L for granite(of any type) work(table rubbed and polished) cooking platform and like set in cement mortar (1:4) incl pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite thickness of granite 20mm incl 15mm thick screed bed 1:6 complete all as specified and directed by Engineer-in-charge.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-charge.
M&L Non Skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed or bedding layer of mortar 15mm thick in CM 1:6 complete all as specified and directed by Engineer-in-charge.
M&L 25mm thick PCC 1:2:4 type B-0 (12.5 mm graded stone aggre) as in sub base of floor complete all as specified and directed by Engineer-in-charge.
M&L for coloured glazed ceramic tiles 350x250x7mm / 450 x 300 x 7mm thick in dado/ skirting ,set and jointed in neat cement slurry & pointed in coloured cement to match over and including 10mm thick backing coat in CM 1:4 complete all as specified and directed by Engineer-in-charge.
S&F in repairs 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed by Engineer-in-charge.
S&F 75 mm bore PVC (SWR) bends any radius complete all as specified and directed by Engineer-in-charge.
S&F 75mm dia of outlet PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed by Engineer-in-charge.
Taking up or down steel tubing 15mm bore and connections including cleaning for refixing or removing from site complete all as specified and directed by Engineer-in-charge.
All as per item 15 above but 20 mm bore pipe complete all as specified and directed by Engineer-in-charge.
S&F 20 mm bore tubes, galvanized steel, medium grade, with all fittings and fixed to walls/ceiling or laid in floors complete all as specified and directed by Engineer-in-charge.
All as per Ser item 17 above but 15 mm dia
S&F in repairs bib tap 15 mm bore brass chromium plated (fancy type,etc complete all as specified and directed by Engineer-in-charge.
S&F in repairs angular stop cock, brass chromium plated fancy type complete all as specified and directed by Engineer-in-charge.
S&F in repairs 50 mm bore ball brass valve, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule complete all as specified and directed by Engineer-in-charge.
S&F in repairs PVC connection 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed by Engineer-in-charge.
S&F in repairs PVC valve less, symphonic action type, flushing cistern, low level, 10 litres capacity, white, with inlet, ball valve, float and handle including PVC flushing pipe, 32 mm dia and fixed complete all as specified and directed by Engineer-in-charge.
S&F in repairs brass chromium plated over head shower rose of 100 mm dia including fixing to steel pipe or union.Cat No Jaquar OHS-1989 and equivqlant Marc complete all as specified and directed by Engineer-in-charge.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm Each complete all as specified and directed by Engineer-in-charge.
Taking down shutters of any description exc 1 Sqm n. exc. 2 Sqm Each complete all as specified and directed by Engineer-in-charge.
M&L for flush shutters 35mm thick with solid core construction with block board core and ply wood face panes with commercial type on one side and decorative face veneer with one side including lipping/frame to match complete all as specified and directed by Engineer-in-charge.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC sheet strip of 20 mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, and fixing in the frame at site as per specification & drawing complete all as specified and directed by Engineer-in-charge.
S&F framed work such as grills, gratings etc, with ends of bars shouldered and or riveted or ferged into spikes, framed guard bars,chowkats frame etc complete all as specified and directed by Engineer-in-charge.
S&F solid PVC door frame of size 50mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed by Engineer-in-charge.
S&F mild steel butt hinges of size 100mm, medium weight complete all as specified and directed by Engineer-in-charge.
S&F 300 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed by Engineer-in-charge.
S&F extruded aluminium alloy handles, fabricated type, anodized of size 150 mm complete all as specified and directed by Engineer-in-charge.
S&F 150 mm long aluminium, anodized, barrel tower bolts of extruded section and fixed complete all as specified and directed by Engineer-in-charge.
S&F in repairs 2000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I, connecting up pipes including 20 mm bore ball brass valves, high pressure, with polythene float and fly- nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new wooden surfaces of any description, over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-charge.
Taking down cement plaster, any description on brick, concrete or stone walls or ceiling including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off complete all as specified and directed by Engineer-in-charge.
M&L 15mm thick rendering with readymix plaster (as per manufacture's instruction) on faces of brick work or concrete surfaces, finished even and smooth surface without using extra cement on wall of up to four stories bldgs complete all as specified and directed by Engineer-in-charge.
M&L 5mm thick rendering with readymix plaster (as per manufacture's instruction) in ceiling on concrete surface, finished even and smooth surface without using extra cement complete all as specified and directed by Engineer-in-charge. Note for Srl item No 39 & 40 :- 1. Make of readymix plaster shall be Birla Aerocon/Ultratech readiplast/ACC Accoplast / Fosroc Chemical (India) Pvt Ltd Renderoc and as approved by GE) 2. The readymix plaster shall be procured directly from the manufacturer or their authorised dealer. 3 The contractor shall produced original purchase voucher alongwith test certificate of readymix plaster while claiming RAR/ Final Bill.
M&L for preparation of new plastered wall surfaces and applying two coats of cement base paint, white or tinted (colour and shade as per new colour scheme approved by GE) over a coat of primer of same make including scaffolding for four storey building complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old decorated wall surfaces by complete removal of existing treatment and applying two coats of cement base paint, white or tinted (colour and shade as per new colour scheme approved by GE) over a coat of primer of same make including scaffolding for four storey building complete all as specified and directed by Engineer-in-charge.
M&L for Preparing new plastered or unplastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted over & including a coat of wall care Putty complete all as specified and directed by Engineer-in-charge.
M&L for preparation by complete removal of existing treatment , wahsing down and stopping of distempered and painted surfaces and old plastered or unplastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted over & including a coat of wall care putty complete all as specified and directed by Engineer-in-charge.
Complete removal of existing treatment , wahsing down and stopping of distempered and painted surfaces and preparing old plastered or unplastered surfaces of wall and applying three coats of white wash complete all as specified and directed by Engineer-in-charge.
M&L for Preparing new plastered or unplastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed by Engineer-in-charge.
M&L for applying two coat of white wash on ceiling of old surfaces including preparation of ceiling surfaces complete all as specified and directed by Engineer-in-charge.
S&F 100 mm dia grating doom of PTMT (minimum weight 25 gms) complete all as specified and directed by Engineer-in-charge.
M&L for applying a coat of cement slurry @ 0.488 Kg/Sqm mixed with tapercreate @ 0.253 Kg/Sqm after cleaning and drying the old/new surfaces(Make of tapercreate M/S CICO Engg Services) then applying the layer of fibre glass cloth while the above coat is still green. The overlap of fibre glass cloth shall be not less than 100 mm.(Make of fibre glass cloth M/S The Structure Water Proofing Co Pvt Ltd) and then applying 1.5 mm thick layer @ 1.288 Kg/Sqm mixed with taper create @ 0.570 Kg/Sqm and coarse sand @ 1.289 Kg/Sqm. Allow the treatment to air curing for four hours followed by water curing for 48 hours complete all as specified and directed by Engineer-in-charge.
M&L for 10 mm thick cement plaster on brick/ concrete surface in CM 1:3, finished even and smooth surface with out using extra cement but mixing water proofing compound at the rate of 2% of cement by weight (WPC shall be paid separately) complete all as specified and directed by Engineer-in-charge.
Supply only liquid water proofing compound complete all as specified and directed by Engineer-in-charge.
M&L Cement concrete Type F2 (1:5:10) using 40 mm graded stone aggregate in mass concrete in sunken floor complete all as specified and directed by Engineer-in-charge.
M&L 75 mm thick PCC type D2 (1:4:8) using 40 mm graded stone aggregate as in sub base of flooring complete all as specified and directed by Engineer-in-charge.
S&F vitreous china squatting pan , ‘Orissa’ pattern, size 580 mm x 440 mm, white with integral foot rests, (excluding flushing cistern and flush pipe) complete all as specified and directed by Engineer-in-charge.
S&F in repairs 15 mm bore concussive push button taps of cast copper alloy, screwed for iron pipe and fixed in repairs complete all as specified and directed by Engineer-in-charge.
S&F in repair brass chromium plated Pillar cock with extension body 15 mm bore complete all as specified and directed by Engineer-in-charge.
S&F in repair for Counter sunk vitreous China wash hand basin,oval shape flat back, size 550x400 with waste coupling , 32 mm dia PTPT full thread complete all as specified and directed by Engineer-in-charge.
S&F in repair Vitreous China Urinal, full stall type,including fixing long screw and urinal speader PTMT of any colour fixing 15mm dia etc complete all as specified and directed by Engineer-in-charge.
S&F towel rail 600 mm long of brass chromium plated fixed with & including chromium plated brass screw complete all as specified and directed by Engineer-in-charge. Make - Jaguar cat No. ACN1111N or equivalent in Marc/Parryware Diamond series.
S&F in repair soap dish vitreous chinna white 160x180x90mm etc complete all as specified and directed by Engineer-in-charge.
Taking down cast iron pipes 100mm/75mm including fittings by burning out lead joints etc to facilitate dismantling old serviceable fittings/pipes laid in trenches,floors or fixed to walls all as directed including earth work, demolition of PCC / Brick work complete all as specified and directed by Engineer-in-charge.
S&F in repair cast iron floor trap/nahani trap incl stainless steel gratings, 75 mm dia of outlet, including jointing to waste pipe fixed in cement concrete type B1(1:2:4) complete all as specified and directed by Engineer-in-charge.
S&F 75 mm bore cast iron, sand cast ,soil, waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches/ wall floors complete all as specified and directed by Engineer-in-charge.
S&F 100 mm bore cast iron, sand cast ,soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed to wall complete all as specified and directed by Engineer-in-charge.
S&F 75 mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-charge.
S&F 100 mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-charge.
S&F branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches for 75 mm bore pipe complete all as specified and directed by Engineer-in-charge.
S&F 75 mm dia cast iron cowls complete all as specified and directed by Engineer-in-charge.
S&F branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access door for 100 mm bore pipe complete all as specified and directed by Engineer-in-charge.
S& Fixed in repair vitreous china partition , coloured of size 700 x 340 x 120 mm complete all as specified and directed by Engineer-in-charge. Make- Cera Cat No 5011 or equivalent in Parryware or Hindware with complete fittings or equivalent Neycer
Removal of excavated material exc 1.50 km distance & deposited where directed at a level n.exc 5 km above the starting point complete all as specified and directed by Engineer-in-charge.
S&F steel windows with side hung shutters including projecting type hinges with steel handles,steel peg stays complete with glazing bars dovetailed or welded complete all as specified and directed by Engineer-in-charge.
M&L sheet glass ordinary quality 4mm thick and glazing with oil putty in squares exc. 0.5 sqm each pane complete all as specified and directed by Engineer-in-charge.
S&F in repairs galvanised mild steel wire cloth, 0.56 nominal dia of wire and average width of aperture 1.00 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed by Engineer-in-charge.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed by Engineer-in-charge.
Preparation of old painted surfaces of steel & Iron of any description over 10 cm width or girth and applying one coat of synthetic enamel paint (1st quality) complete all as specified and directed by Engineer-in-charge.
M&L for greasing ,oiling , including tack welding where required to steel windows ( area of each window exc 0.5 sqm and n exc 2.5 Sqm) frame, shutter, etc to make fully functional and easing , opening and closing complete all as specified and directed by Engineer-in-charge.
S&F 32mm dia LDPE 6kg/cm2 for waste pipe of wash hand basing complete all as specified and directed by Engineer-in-charge.
S&F 40mm dia LDPE 6kg/cm2 for waste pipe of urinal complete all as specified and directed by Engineer-in-charge.
Demolition of mud in roof, any thickness, including plastering and leeping incl necessary scaffolding arrangement complete all as specified and directed(whether full thickness removed or only a part there of) and removing from cantonment area or as directed complete all as specified and directed by Engineer-in-charge.
M&L for brushing neat cement slurry with 3.00 Kg of cement per Sqm on existing surfaces complete all as specified and directed by Engineer-in-charge.
M&L 40 mm thick (average thickness) plain cement concrete 1:2:4 type B-0 using (12.5 mm graded aggregate), as in roof ,padding to maintain the uniform slope complete all as specified and directed by Engineer-in-charge. Note : - WPC shall be measured & paid separately.
M&L for rendering 15 mm thick (average) plaster on concrete surfaces in CM (1:4) on roof, mixed with water proofing compound and finishing the surface even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L, Priming roof surfaces and applying water proofing treatment over roofs comprising of the following complete all as specified & as directed:- (a) Applying oil bound bituminous primer at the rate of 0.4 Ltrs/Sqm as per IS 3384-1986 on prepared surfaces. Surface shall be kept free till the moment, the primer is impregnated and the solvent oil in primer is evaporated. (b) Applying one coat of hot straight run bitumen @ 1.20 Kg/Sqm of grade 30/40 confirming to IS-73 (Grade S-35). (c) Laying 3mm thick APP polymeric water proofing membrane of weight not less than 3.6 kg/sqm, black finish reinforced with non woven polyster matt, with a thermo fusible finish, torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer's instruction including preparation of surface. (d) applying two coats of aluminium base paint over APP Membrane. Make: "Moply FP" manufactured by STP Texsa Ltd or Hyper Plas (Polyester) manufactured by M/S IWL Ltd or "Shaliplas"ter) manufactured by M/S Capital Steels and Chemical Pvt Ltd or Makpolyplast manufactured by M/S M K Patro as approved by GE. Note :- The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators. The contractor shall give 10 years guarantee for effectiveness of water proofing treatment, 2.5% of work done amount of this item shall be retained from contractors payment for a period of 10 years reckoned from date of physical completion of this work, or in lieu contractor may deposit bank FDR for the said amount for 10 years which shall be released by GE on expiry of satisfactory completion of 10 years period.
M&L for post anti termite treatment along the external wall below concrete or masonry apron using chemical emulsion @2.25litres per linear metre including drilling and plugging holes etc.in apron complete all as specified and directed by Engineer-in-charge.
Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in Soft / loose soil complete all as specified and directed by Engineer-in-charge.
Excavation in post holes (or Similar holes) each not exc 0.50 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25cm, watering and removing surplus soil to a distance not exc 50m and making good surface in soft/loose soil complete all as specified and directed by Engineer-in-charge.
M&L for providing cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundation filling and mass concreting complete all as specified and directed by Engineer-in-charge.
M&L for rendering 10mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces and finishing the surface even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement and pigment complete all as specified and directed by Engineer-in-charge.
M&L for removing excavated soils exc. 500m and and n. ecx 500 mtr depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and directed by Engineer-in-charge.
M&L for sand filling in floors or pavings, laid in layers n exc. 15 cm thick spread, levelled and rammed including watering complete all as specified and directed by Engineer-in-charge.
S&F steel work in tubular truss including special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS-1161-1979 of grade St-240 complete all as specified and directed by Engineer-in-charge.
S&F bands, straps, supports or stays for rainwater, plain angle cleat for securing purlin, knee piece inserts, two way and three way straps, plate washer and similar small articles, confirming to Fe-290 Gde E-165 complete all as specified and directed by Engineer-in-charge.
S&F plates (plain or chequered) Channels, square, cut or notched (ordinary and counter sunk) forming holes without any attachment of Fe-410-W (Grade E-250) quality B complete all as specified and directed by Engineer-in-charge.
S&F mild steel works such as wind ties for roof including securing with bolts etc and similar work using rolled section confirming to Fe-290 Gde E-165 complete all as specified and directed by Engineer-in-charge.
S&F pre-colour coated high tensile strength galvalume sheet roofing with yield strength (550 NPA) prepainted with aluminium (55%) and zinc (45%) alloy coating applied through continous hot dip process having tatal coated thickness (TCT) of 0.50mm with minimum coating mass on both sides @ 150gms/sqm in length and width as per site condition fixed with complete acessories as per manufacturer's instructions through specialist agency and as per profile and shade complete all as specified and directed by Engineer-in-charge.
All as per Sl item No 98 here-in-before but as in ridge / flashing board of width and girth not less than 610mm complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new steel surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of redoxide complete all as specified and directed by Engineer-in-charge.
M&L 75mm thick Cement concrete type C-2 , 1:3:6 (using 40mm graded aggregate) as in plinth protection finished surfaces even and fair without using extra cement complete all as specified and directed by Engineer-in-charge.
S&F Mild steel screw bolts(machine made)11 to 15mm dia of shank with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or squarae nut, exc 5cm but n.exc 10 long complete all as specified and directed by Engineer-in-charge.
M&L coloured /light shade vetrified ceramic tiles 10mm thick (square/regtangular) polished , area of each tiles not exc 0.36 sqm in floors etc and joineted neat in cement slurry and pointed in white or colour cement to match over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed by Engineer-in-charge.
All as per item No. 103 above but on vertical surfaces such as dados, skirtings and risers to steps, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 on stone masonry surfaces complete all as specified and directed by Engineer-in-charge.
Surface dressing n. exc.15 cm deep in soft/loose soil complete all as specified and directed by Engineer-in-charge.
M&L for cement concrete (1:2:4) type B1 using 20mm graded stone aggregate as in coping incl necessary form work complete all as specified and directed by Engineer-in-charge.
M&L for Machine cut Kota stone slab flooring 20-25mm thick laid over 20 mm screed bed or bedding layer 1:6 cement mortar laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and directed by Engineer-in-charge.
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar, laid over 10mm thick backing coat over fare face of brick work and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and directed by Engineer-in-charge.
E/M Works Taking down carefully the old U/S aluminum point wiring (light, fan, socket or power) complete fitting such as switches, ceiling roses, pendants, sockets, regulators, etc and making good disturbed surfaces of walls including necessary touch up with the adjoining surface of disturbed area ie with OBD/colour wash/white wash as the existing finish complete all as specified and directed by Engineer-in-charge.
M&L light/fan/bell point controlled by one modular switch with PVC insulated, sheathed, multi stranded, single core copper conductor cable 1.5 Sqmm suitable for fixing in existing concealed conduit with modular sunken pressed steel terminal boxes 2 mm thick of required size and modular white cover plate and frame in different module housing for fixing modular switches/modular socket and modular fan regulator etc. PVC insulated, unsheathed, multi stranded, single core copper conductor cable 1.5 Sqmm used as earth wire to commen earth and connected to common dolly drawn in same conduit complete all as specified and directed by Engineer-in-charge. Note : If blockage or damage of the existing conduit, new PVC conduit to be laid to passing the light/fan circuit and the rate of the same is inclusive in respected item) Make of wire : Polycab/Havells/Finolex
One light / fan point controlled by one No one way switch
One light point controlled by two 2-way switch
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board.
All as per item No 110 but point wiring with 2.5 Sqmm single core copper cable and earth continuity wire with 2.5 Sqmm single core cable for one three pin 15 socket outlet point on independent board.
S&F switch piano flush type 5/6 Amp complete one way single pole complete all as specified and directed by Engineer-in-charge.
S&F in repairs switch piano flush type 6 Amp two way ISI marked complete all as specified and directed by Engineer-in-charge.
S&F socket outlet 5 pin 5/6 Amp complete two in one complete all as specified and directed by Engineer-in-charge.
S&F switch piano flush type 15 Amp complete all as specified and directed by Engineer-in-charge.
S&F socket outlet 2 in 1, 5 pin 15/5 Amp complete all as specified and directed by Engineer-in-charge
Supply fix battan holder PVC insulated body complete all as specified and directed by Engineer-in-charge.
S&F ceiling rose surfaces bakelite minimum size 65x50mm with two/ three terminals complete all as specified and directed by Engineer-in-charge.
S&F LED Integrated Batten T5 20 Watt, 4' white, indoor decorative PVC extruded T5 LED battern -integrated type complete with including fliexble wire in replacement of old unsv existing 36 Watt tube light fitting, Cat Part No LTTB4F20LEDP/W of Make : C&S or equivlent Make in Havells/Bajaj/Philips/CG.
S&F LED RETROFIT LAMP of 12 Watt LED lamp for wall mounting fiiting\ Holder complete all as specified and directed by Engineer-in-charge.
S&F LED Integrated Aluminium Batten T5 10 watt - 2 Ft White, indoor decorative PVC extruded T-5 LED battern - integrated type complete with all accessories including flexible copper wire in replacement of old unsv existing 36 Watt tube light fitting with Cat Part No HLB-03-20-CW-AL of Make : Halonix or equivalent Make in Havells/Bajaj/Philips
Taking down of exsting tube light fitting/mirror/bldg security light fitting and bldg security light fitting any type and make complete all as specified and directed by Engineer-in-charge.
S&F LED Building security light fitting 30W on existing bracket in replacement of old unsv existing security light fitting any type Cat Part No LTESS30WLED of C&S or equivalent in Havells/Philips/Bajaj).
S&F in repairs MCB DB SPN 8 Way with metal double door, (IP-43 Protection) flush mounting epoxy powder control having 200 Amps rated bus bar complete all as specified and directed by Engineer-in-charge.
S&F in repairs MCB SPN C curve 32/40 Amps 240 Volts, 10 KA complete all as specified and directed by Engineer-in-charge.
S&F in repairs MCB SP C curve 10 to 40 Amps 240 Volts complete all as specified and directed by Engineer-in-charge.
M&L in repairs for submain wiring of two runs of 6 Sqmm size for main cable and one run of 6 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked, drawn through existing steel/PVC conceiled conduit of size 25mm dia with all fittings accessories complete all as specified and directed by Engineer-in-charge. Note:- 3 run of 6Sqmm cable shall be measured and paid as one unit.
M&L in repairs for submain wiring of two runs of 10 Sqmm size for main cable and one run of 6 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked, drawn through existing steel/PVC conceiled conduit of size 25mm dia with all fittings accessories complete all as specified and directed by Engineer-in-charge. Note:- 2 run of 10 Sqmm and 1 run of 6 Sqmm cable shall be measured and paid as one unit.
S&F in repairs of distribution board vertical triple pole and neutral (VTPN) 6 way for fixing MCCB up to 125 Amps as incomer and MCBs as out goings with metal door and IP 43 Protections and connecting complete all as specified and directed by Engineer-in-charge. with Cat Pt No : BEMD 100T8 of Benlo or equivalanet make of Legrand/ABB/Havells
S&F in replacement MCCB 125 Amp, 415 Volts, 3 Pole, fixed type with breaking capacity of 36 KA complete all as specified and directed by Engineer-in-charge.
Taking down the existing exhaust fan any type and refixing the same after completion of civil work including necessary electrical works with electric connection by suitable flexible copper wire complete all as specified and directed by Engineer-in-charge.
Supply & fixing water storage heater 25 ltr capacity, 5 Star rated , vertical type, AC, electric, 230 volt, complete with heating element, thermostat, 3 core lead, Plug top, safty valve, inluding electric and water connection using MS Iron suitable nuts, bolts and washers for fixing of geyser and making good to disturbed surfaces complete all as specified and directed by Engineer-in-charge.
S&F Modular box with MCB 20 Amp complete with metal box and 3 Pin top plug complete all as specified and directed. Note : Rates are inclusive of cutting / chases for mounting modular metal box concealed in wall and making good to disturbed surfaces with OBD / Colour wash / white wash and wall putty where ever required complete all as specified and directed by Engineer-in-charge.
S&F PVC connection with brass nipple 15 mm x 600 mm long with ISI marked suitable for hot and cold water of 25 ltrs capacity of geyser as hot and cold water connection complete all as specified and directed by Engineer-in-charge.
S&F bib tap 15mm bore of cast coper alloy CP fancy type scrwed to iron pipe and fixed complete all as specified and directed by Engineer-in-charge.
S&F stopcock concealed Angle type 15mm dia cast copper alloy CP fancy type screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-charge.
M&L for Sub main wiring with two runs of single core 4 Sqmm size and one run of single core 4 Sqmm (green colour as earth continuty conductor) PVC insulated unsheathed multi stranded copper conductor cables drawn through and including rigid PVC casing caping complete all as specified and directed by Engineer-in-charge. Note:- Two runs of 4 Sqmm single core copper conductor and one runs of 4 Sq mm copper conductor shall be measured as one unit length)
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
verma enterprises
M/S.M.S.Devi.Const.Co
P R Constructions
M/S GOPAL JEE SINGH
Chaudhary Constructions
M/S.Parmod Johar
bhumica construction co.
Ish Engineers and Contractors
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .