Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹70.0 LAccepted-AOC | L1 | Accepted-AOC Lower Rate | |
| 2 | L2₹99.0 L+₹27.2 L (37.9%)Rejected-AOC | L2 | Rejected-AOC Higher Rate | |
| 3 | L3₹87.5 L+₹15.7 L (21.9%)Rejected-AOC | L3 | Rejected-AOC Higher Rate |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
24 Dec 2021, 12:00 pmClosed
Superintending Engineer
Electricity Construction Circle.,RPH,Kesco, Kanpur
Laying 33 kVXLPECable from220/33 kV S/S Kidwai Nagarto Newproposed Railway Elect.Train.Inst.,Juhi, for releasing2200KVA Load at33kVsupply of existing 2140 KVA load diff. tariff at11kV supplyof Dy.Chief Elec.Eng./ Const.N.C.R. Kanpur EUDD-Gumti,Kesco
2021_KESCO_654926_1
34/Const./2021-22
Open Tender
Construction Works
Item Wise
180 days
EUDD-Gumti, Kesco, Kanpur
Please refer tender document
2 documents required · 2 mandatory
₹5,900
Kesco
₹1.3 L
8 Feb 2022
11 Dec 2021
24 Dec 2021
11 Dec 2021
24 Dec 2021
11 Dec 2021
Taking out of 33/11 kV XLPE 3x300 Sq.mm cable from drum/complete drum of cable at site of work or store using JCB including carriage
Digging of Trench for laying of cable/DWC Pipe in different situations in size of 30 cm. wide and 1 to 1.5 meter deep.
In Normal soil
In Kharanja Soil
In Metallic Road
Laying of 33 KV XLPE cable/DWC Pipe in above digged trench/DWC Pipe covering with bricks(in case of cables only) and back filling and proper ramming.
Laying of MS pipe in digged trench
Supply and Laying of Double Wall Corrugated Electrical Conduit Pipe of 160 mm dia, in digged trench.
Laying of Cable in MS Pipe
Laying of Cable by HDD method without HDPE pipe
Laying of Cable by HDD method with 200 mm dia HDPE pipe across railway track ( RoW issues, if any, to be settled by bidder with Railway officer)
Laying of Cable by HDD method with 160 mm dia HDPE pipe
Making 33/11 kV straight through joint including digging of pit upto 1.1 metre depth and making a proper chamber for straight through joints using bricks, cement, etc.
Making indoor/outdoor joints of 11/33 KV XLPE Cable where the cable is being laid.
Mounting of cable box on double pole/cable support structure without Pipe
Mounting of cable box on double pole/cable support structure With Pipe
Loading, Carriage and unloading of ST poles including old pole from store to work site or vice versa
Loading,Carriage and unloading of ACSR Dog Conductor from Store to Work Site or Vice-Versa.
Laying of ACSR Dog Conductor
Laying of G.I. Wire including lacing
Fabrication/modification of MS Item as per requirement of site
Erection of Single S.T. Pole as per standard specification
Erection of double pole structure including excavation of pit as per standard specification
Grouting of pole with cement brick ballast and coarse sand as per standard specification.
Making plinth of single pole of 400 mm dia, 600 mm height (200mm underground) with C.C. in ratio 1:4:8 of cements, stone ballast and coarse sand including cost of materials.
Painting of S.T. pole with one coat of red oxide and two coats of Alm. Paint including cost of Ist Class enamel paint.
Earthing of supports as per standard specifications.
Chopping of tree branches lying in the route of existing line touching the tree branches to the phase line conductor making fault to the feeder, for 3” to 18” dia or as per requirement of site.
Opening of H.T. Jumpers from the existing 3 Phase 3 Wire H.T. O.H. line for erection work.
Making of H.T. Jumpers from the existing 3 Phase 3 Wire H.T. O.H. line for erection work.
L/C for mounting of Pin/Disc Insulator
Fixing of stay rod and its erection and grouting by fitting of stay clamp. Stay wire and its proper binding and tightening etc.
Fixing of danger board on erected poles
Making of H.T. Section Point
40 feet deep pipe Earthing along with supply of material
Plinth for H.T. metering cubicle
Erection of H.T. metering cubicle along with earthing at two points
Supply and Fixing concrete Stone Route marker of 300 mm width x 150 mm thick x 650 mm height embedded in earth at least 300 mm below and 350 mm above ground level at every 100 m along the length of the cable with RCC concreting as per standard specification.
Making riser from existing earth mate of control room for making earthing support to newly erected 33 kV VCB/CRP in control room/switchyard
Carriage of all concerning stock material except mentioned above from Kesco. Store to site or vice-versa.
Connecting of newly erected network with Kesco mains including testing, commissioning and energization of the same completely.
M/S AARADHYA AND ADHYATM ASSOCIATES
Khan Traders and Electrical Works
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .