| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | First₹38.2 LAccepted-AOC | First | Accepted-AOC Responsible bidder |
Tender Value
₹38.2 L
EMD Value
₹76,500
Closing Date
26 Dec 2019, 6:00 pmClosed
Executive Engineer DWSS Moga
Room No. 313 3rd Floor Jhelum Chenab Complex DAC Moga
Prov installing 150 mm straight TW with Hand Boring 150 mtr. depth, machinery, Chlorination Plant repair of PC Prov, Laying, Cutting, Jointing and Testing of PVC pipe, Const of RCC OHSR 25 cum height 18 Mtr dev of WW etc. complete
2019_WB_41672_1
PRWSSIP/2019/Lalhaundi
Open Tender
Civil Works - Water Works
Item Rate
305 days
Village Lalhaundi
Please refer Tender documents.
8 documents required · 8 mandatory
₹1
TIA
₹76,500
7 Feb 2020
10 Dec 2019
27 Dec 2019
10 Dec 2019
26 Dec 2019
10 Dec 2019
Amount
Boring with casing pipe for tube well in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested, equipment as required such as hand boring machine and its accessory,transportation to site and vice versa etc. complete in all respect. (CSR Item No- 28.72)
(b) Boring with 200mm I/d Housing Pipe
Up to 0 to 150m BGL
Supplying, lowering of MS Pipe as per IS: 4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore. (CSR Item – 28.74A)
(b) 150mm nominal diameter (weight 21.6 kg per meter) 5.4 mm thickness
Supplying, lowering of stainless steel cage type wire wound screen as per IS 8110-2000 or latest ISI marked duly welded with suitable grade S.S. welding electrode to lower the strainer into tubewell bore . (CSR Item – 28.75A)
(i) 150 mm internal dia meter (slot size 0.15/0.20) 5.00 mm thickness
Supplying, fixing and lowering of stainless steel socket as per IS 8110-2000 or latest ISI marked duly welded with suitable grade S.S. welding electrode to lower the strainer into tubewell bore complete in all respects. (CSR Item – 28.75 AA)
a) 150 mm internal dia meter
Supplying, Lowering & fixing of M.S. special socket to connect S.S. Strainer to M.S. Pipe duly welded with suitable grade welding electrode complete in all respect. (CSR Item – 28.76)
a) 150 mm internal diameter
Supplying & fixing of M.S. Clamp of size 150mm x 12mm made out of MS Flat 1.52 m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect. (CSR Item – 28.77)
Supplying at site Wooden box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore. (CSR Item – 28.78)
Supplying & fixing of bail plug of M.S. pipe complete with inverted U-hook attached to the bottom plug complete in all respect. (CSR Item – 28.79A)
b) 150mm internal diameter (weight 21.6 kg per meter) 5.4 mm thickness
Supplying and fixing M.S well cap having thread to fix on housing pipe complete in all respect (CSR Item – 28.80)
b) 150 mm internal diameter
Development and stabilizing of the tube well with air compressor of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. (CSR Item – 28.81)
a) Capacity of Air compressor 300 cfm at 250 PSI
Development and stabilizing of the tube well with submersible pump of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. (CSR Item – 28.82)
Collection of water sample from different strata and testing of sample from approved laboratory (Physical & chemical Analysis) (CSR Item – 28.83)
Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide etc.) (CSR Item – 28.84)
Provision for Uranium in water testing
Constructing one No. of 25 KL (25000 litres) Capacity with sill level not less than 15.50m height upto FSL 18.00 mtr from formation level complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator single main hole cover lightening conductor etc. complete as described in schedule No.3. Providing and fixing DI K-9 D/F expansion joints conforming to (IS-1536-1989) or latest bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, Conforming to ISI - 13382 and DI K-9 D/F sluice Valve duly ISI marked (IS-14846-2000 or latest) one each with inlet, outlet and scour pipes, including providing and installing inlet, outlet scour pipe and overflow DI K-9 double flanged pressure pipes horizontally cast in sand moulds as per IS 7181/1986 and latest duly ISI marked from bottom dome to duck foot bend and further up to 2.75 mtr as per detail specification. TMT steel & painting of all complete shall be included in cost & P/F aluminium leader inside, steel ladder outside tank of the OHSR complete in all respect as per specifications. (The specifications & drawing are based on safe bearing capacity of soil of is not less than 8.75 tone per sqm. In case the safe bearing capacity of soil is less than 8.75 tone per Sqm. The contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS specifications. The difference in quantities from the standard drawing based on 8.75 tone per sqm safe bearing capacity will be paid as per CSR+ Prevailing Ceiling Preminum including overflow haudi including providing and fixing automatic Electronic Water Level control Device and Construction of Plinth protection around OHSR with masonry toe wall with 40 mm thick CC 1:2:4 on top over 100 mm thick CC 1:8:16 & inside earth filling within lead of 5 km, complete in all respects.
Providing, laying, fixing & jointing of PVC pipe as per ISI-4985 (ISI Marked with the prior approval of Engineer in- Charge ) along the tranches and laying the same in tranches to correct alignment and gradients , cutting, jointing & testing complete as per specifications. For more than 3 mtr. Street width Complete in all respect. (Mechanically ) (10kgf/ cm2) Pressure
110 mm i/d PVC Pipe 10kg/cm2
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge)
(CSR item No. 28.27 A(a)
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department size 0.90m x 0.90m
(CSR item No. 28.66(b))
Providing, laying, fixing & jointing of PVC Pipe as per ISI-4985 (ISI Marked) with prior approval of Engineer-in-chargealong the Trenches and laying the same in Trenches To correct alignment and gradients, cutting. Jointing and testing, including specials & excavation complete as per specifications. (With Mannual Earth work).
(CSR item 28.1, 28.13 & 28.18 )
PVC pipe 63mm o/d
PVC pipe 110mm o/d
Providing, laying, fixing & jointing of PVC Pipe as per ISI-4985 (ISI Marked) with prior approval of Engineer-in-chargealong the Trenches and laying the same in Trenches To correct alignment and gradients, cutting. Jointing and testing, including specials & excavation complete as per specifications. (With Mech. Earth work).
(CSR item 28.2, 28.13 & 28.18)
PVC pipe 63mm o/d
PVC pipe 90mm o/d
PVC pipe 110mm o/d
Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting.
Dismantling of metallic road with bituminous course 50 to 75mm thick C.C. 1:8:16 and making good the same to its original condition complete in all respects as per analysis A – 25 Note:-Contractor shall quote rates only for dismentling of matelled road and back filling with excavated earth , fully compacted. the restoration of the metalled road to its original condition will be done by the concerned department i.e. PWD (B&R)/PMB/ Panchayati Raj.
PVC pipe 63mm o/d
PVC pipe 90mm o/d
PVC pipe 110mm o/d
Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) B- Class,premium make such as (Jindal Hisar) including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete.
(CSR item No. 28.36 h)
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in - charge)
(CSR item No. 28.27 (a))
80 mm I/d sluice valve flanged
100 mm I/d sluice valve flanged
Providing, Fixing & jointing Cast Iron Surface box for Sluice Valve, Air Valve, Fire hydrant etc. including all carriages complete 12No. with Each 3kg I.e (9 x 3 = 27kg)
as per CSR item 28.32
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department 10No. With each of Size 0.6m x 0.6m
(CSR item 28.66)
Water Connection Providing proposed water connection to house hold up to wall with providing, laying jointing, testing GI pipe lines 15mm i/d=2.50 mtr B- Class as per CSR 28.36 (A),( Above GL), Prov. & fixing MDPE pipe 15mm i/d with specials 2.00 Mtr (Below GL) including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 15mm i/d GM ferrule as per IS: 2692 and 3" i/d upvc clamp with c.i bib cock 15mm i/d as per IS:210 with stainless steel spindle of approved make as per CSR 30.65(b)
Prov. & Fixing Electronically actuated, Diaphragm Operated, Metering System, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 Litres of Bleaching Powder solution/ Sodium Hypo solution per hour under maximum delivery pressure upto 7 Kg.cm2, and suction lift not less than 1.5 m, as per DWSS standard specifications.
Construction of brick masonry pump chamber of size 2.20 x 2.20 mtr. with attached W.C. under the Over Head Service Reservoir, complete in all respect but excluding gravel pit, as per W/S & Sanitation Deptt. design & drawings including cost of material such as bricks, cement, Bajri & TMT steel, internal wiring etc. complete at Water Works site.
Providing and installing 80mm dia delivery main (From Tube well to Duck Foot bend including cost of C.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as C.I Bends, Tail Piece Tees etc.. inside the pump chamber as per standard design complete in all respects as Annexure A12 – 1 & Drawings D-12 & D-17.
Providing & installing,testing & commisioning of 1 no electrically driven Submersible Pump set of 5.00 BHP KSB make capable of delivering 165 LPM against a head of 54 mtr along with electric panel board consisting of electrical appliances such as automatic Star Delta Push Button or oil imeersed starter,Main Switch,VM,AMpere Meter,ELCB,Shunt capacitor.Single phase,preventer,Indicating lamps,Kit-Kat etc. including M.s column Pipe of IS 1239-2004 medium class size 50mm and Length 60 mtr.(in 3mtr lengths each with flanges,screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable of 100 Mtr. Length and 2.50mm2 size as per IS694-1990 reaffirmed 2000 complete in all respects
Rate Analysis of WS&S Department Punjab
Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing D-6 & 8 (as per Analysis A-6)
Providing and Fixing precast pre-stressed cement concrete fencing pole M-40 by 4 Nos. parallel high tensile entwined wire (ISI marked wire 4 mm dia fencing pole size at bottom 4" x 4", size top 3" x 4",Lenght 6ft, hooks 6 No. including cost of excavation, sand filling and erection complete in all respects. (As per Analysis).
Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing D-7 & Analysis A-7
Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing D-3 & Analysis A-3.
Construction of masonry gate pillar including cost of MS Steel Gate size 1.22mtr x 1.37 mtr as per standard Drawing with including D-4 & Analysis A-4 complete in all respects
Construction of Cement Concrete, Foot Path with masonry toe wall & earth filling inside water works as per standard Drawing D-7 & Analysis A-10.
Providing & fixing MS Sign Board as per standard size of DWSS as per analysis A-24 & Drawing D-20
Providing, Fixing, Installing, Commissioning, Solar Panel Energy System (Monocrystalline) for amount of electric power required for running electric motor and other appliances such as fan, tube, Bulb etc in water works site. including Bi-directional meter and inverter of suitable capaity as per guidelines issued by PEDA complete in all respects. (system should be as per MNRE specifications 2014-15) (Bidder should quote his rates after deducting the subsidy as per Ministry of New And Renewable Energy ( Grid Connected Rooftop Solar Division) No. 03/88/2015-16/GCRT Dt. 30.03.2017- Below 80 % And Above 50%)
Operation & Maintenance of Water Supply Scheme after its completion and commissioning under the supervision of the DWSS/GPWSC during the O&M period of 3 months. , bidder shall: (i) Salary pay to staff (Pump Operator-cum-Chowkidar) for operate and maintain of WS Scheme; and (ii) Pay the power consumption charges during the O&M period (1/4th on direct electricity and 3/4th on solar system)
Making lawns including ploughing & dragging with 'Sohaga' breaking of clods, removal of earth rubbish dressing & supplying doob grass roots and planting at 15 cm, apart including supplying and spreading of farm yard manure @ 0.18cum per 100 sqm & loosening. (CSR Item-32.4)
Supplying and planting permanent trees including digging of earth pits size 75cm×75cm×75cm deep refilling the excavated earth with manure supplied @ 0.113 cum each and watering supplying through tractor tanker. (Trees like Neem, Ashoka, Dake, Arjun etc. (CSR Item-32.16)
Planting ground cover plants including digging and refilling of beds with excavated soil and FYM, Fertilizer and insecticides, planting of saplings at 30cm distance from plant to plant and row, providing and fixing brick tiles edging. (CSR Item-32.22)
Planting , flower beds including digging and refilling of beds with excavated soil and FYM, fertilizer and insecticides, planting of sapling at 30 cm distance from plant to plant and row to row. (CSR Item-32.2)
Provision for one way stand post with khura complete in all respects.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .