| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 CrAccepted-AOC | ₹7.5 Cr | L1 | Accepted-AOC Amount after deduction of Schedule of Credit for Rupees 4,08,800.25 |
| 2 | L2₹7.8 Cr+₹29.2 L (3.88%)Rejected-Finance D 3 7TH BLOCK JAIN GREEN ACRES DHARGA ROAD ZAMIN PALLAVARAM CHENNAI 600043 | CHENNAI | CHENNAI | TAMIL NADU | 600043 | ₹7.8 Cr+₹29.2 L (3.88%) | L2 | Rejected-Finance Other Than Lowest quoted Bidder |
| 3 | L3₹9.1 Cr+₹1.5 Cr (20.2%)Rejected-Finance | ₹9.1 Cr+₹1.5 Cr (20.2%) | L3 | Rejected-Finance Other Than Lowest quoted Bidder |
| 4 | L4₹9.2 Cr+₹1.6 Cr (21.8%)Rejected-Finance | ₹9.2 Cr+₹1.6 Cr (21.8%) | L4 | Rejected-Finance Other Than Lowest quoted Bidder |
| 5 | Rejected-Technical | - | - | Rejected-Technical Firm is Two Class Below |
Tender Value
₹5.9 Cr
EMD Value
₹6.2 L
Closing Date
14 Sept 2020, 6:00 pmClosed
CE Navy Visakhapatnam
Chief Engineer Navy Military Engineer Services Station Road Visakhapatnam-530 004
DEMOLITION OF CERTAIN TEMPORARY MD ACCN AND RECONSTRUCTION OF PERMANENT ACCOMMODATION FOR OFFICERS AND SAILORS AT TS AVADI CHENNAI
2019_MES_308286_2
CE(NAVY)/VIZ/TOKEN NO 31 OF 2018-19
Open Tender
Civil Works
Lump-sum
365 days
Avadi Chennai
Please refer Tender documents.
6 documents required · 6 mandatory
₹3,000
Yes
AGE I Navy Chennai
₹6.2 L
Yes
13 Jan 2021
28 Jul 2020
15 Sept 2020
28 Jul 2020
14 Sept 2020
31 Aug 2020
Amount
Schedule 'A' Part-I to Schedule 'A' Part-XV: Note: Schedule "A" Part-I to Part-XV are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field
Total amount of Schedule 'A' Part-I (BUILDING AND STRUCTURES)
Total amount of Schedule 'A' Part-II (SITE CLEARANCE/AREA DEVELOPMENT /EARTHWORK)
Total amount of Schedule 'A' Part-III (ROAD /PATH/ CULVERT)
Total amount of Schedule 'A' Part-IV (AREA DRAINAGE)
Total amount of Schedule 'A' Part-V (SEWAGE DISPOSAL)
Total amount of Schedule 'A' Part-VI (RAIN WATER HARVESTING)
Total amount of Schedule 'A' Part-VII (COMPOUND WALL/GATE/FENCING)
Total amount of Schedule 'A' Part-VIII (INTERNAL WATER SUPPLY)
Total amount of Schedule 'A' Part-IX (INTERNAL ELECTRIFICATION )
Total amount of Schedule 'A' Part-X (EXTERNAL WATER SUPPLY)
Total amount of Schedule 'A' Part-XI (EXTERNAL ELECTRIFICATION)
Total amount of Schedule 'A' Part-XII (HOT WATER SUPPLY)
Total amount of Schedule 'A' Part-XIII (LIGHTENING PROTECTION/AVIATION LIGHT)
Total amount of Schedule 'A' Part-XIV (FIRE FIGHTING SYSTEM)
Total amount of Schedule 'A' Part-XV (DEMOLITION & DISMANTLING)
Schedule 'A' Part-XVI (Miscellaneous Items) (Internal Water Supply, External Water Supply, Internal Electrification, External Electrification, Fire Fighting System, Fire Alarm and fire detection System, Rain water harvesting, DG Set, Arboriculture and Lifts):
INTERNAL WATER SUPPLY
S&F Stop valves concealed chromium plated fancy type serewed down high presure with crutch or butterfly handle screwed both ends for iron pipes of size 20 mm dia Make jaquar cat part No ALD 3057 or Equilent Kohler,Hind Ware
Supply and fixing pillar taps fancy type cast copper alloy, with capstan heads, chromimum plated, screwed down high pressure with long screwed shanks and fly nuts screwed for pipes of size 20 mm dia Make jaquar cat part No CON 021KN or Equilent Kohler,Hind Ware
S&F Bib taps long body cast copper alloy chromium plated fancy type with butter fly handle screwed down for size of 20 mm dia Make jaquar cat part No MQT 512KN or Equilent Kohler,Hind Ware
S&Fixing wall mixer brass chromium plated fancy type with provision of over head shower with 115mm long bend pipe on upper side ,connecting legs & wall flange for kitchen room cold and hot water in officer qtrs .Make jaquar cat part No FLR 5273UPR or Equilent Kohler,Hind Ware( for officer bath room)
INTERNAL ELECTRIFICATION
Ponit wiring with 1.5 sqmm FRLS PVC insulated and unsheathed copper conductor multistranded 1100 volts grade, ISI marking drawn thorugh and inculding non metallic PVC rigid concealed conduit and conduit accessories, medium grade, ISI marking, concaled including provn of pre fabricated galvanised module box of 2 mm thick of suitable size as required at site for fixing switches, sockets, inculding one run of 1.5 sqmm PVC insulated unsheathed copper cable for earth continuity, connected to earth duly complete all as specified and directed for one light point controlled by one switch
All as per Item no 20 avove but for one bell point controlled by one switch
All as per Item no 20 above but for one fan (Ceiling/Wall/Exhaust fan) point controlled by one switch
All as per Item no 20 above but for one 3 Pin socket outlet 5 amps socket on independent board
All as per Item no 20 above but for one 3 pin socket outlet 15 amps socket on independent board with 2.5 sqmm FRLS PVC wire and one run of 2.5 sqmm copper cable for earth continuty.
All as per item No 20 here-in-before but controlled by two Nos of two way switches complete all as specified and directed.
S&F Energy efficient 4 ft LED light fitting with tube 20 watt or nearest size, 230V surface mounted LED batten type with extruded aluminium housing and robust constrution with necessary acrylic cover as diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with suitable size.MAKE :-Philips Cat No.BN150WLED20S-6500PSEODGR equalent HAVELLS / Bajaj / CG
S & F 2 ft Energy efficient LED light fitting with tube 10 watt or nearest size ,230V surface mounted LED batten type with extruded aluminium housing and robust constrution with necessary acrylic cover as diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with suitable size.MAKE :-Philips Cat No : BN 021LED10S-6500PSUGRS1 equalent HAVELLS / Bajaj / CG
S & F Energy efficient LED ceiling light fitting 10 watt , integral square shape , 230V surface mounted with necessary diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with suitable size. Make : Philips Cat No : DNO97BLED10S-6500PSUWH equalent HAVELLS / Bajaj / CG
S & F Energy efficient LED mirror light fitting chrome colour ,metal & synthetic led 10 w 3000k 500 with luminare10 watt , 230V surface mounted with necessary diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with suitable size. Make : Philips MODEL No : 48043/30/86 equalent HAVELLS / Bajaj / CG
S & F Energy efficient LED mirror light fitting gray colour ,metal & synthetic led 14 w T-5 , 230V surface mounted with necessary diffuser complete with mounting bracket etc including connecting up with twin core twisted flexible copper conductor cable with suitable size. Make : Philips MODEL No : 38103/11 equalent HAVELLS / Bajaj / CG
S/F LED Security light fitting with tube 20W New generation Energy saving &environmental frindly long life versatile pressure die cast aluminium luminiare with mid power LEDs as source and HF electronic driver pre wired with 1.5 Sq mm copper conductor cable upto connector including 2 Mtr long GI Tubing Med grade 32 mm dia bend to shape fixing on wall with suitable MS brackets compelte all as specified and as directred.Make :Philips Cat No : BRP042LED19CWMRS1PSUGR equalent HAVELLS / Bajaj / CG
Supply and fixing ceiling fans AC single phase 230 V of size 1200 mm sweep with complete set with fixtures, 5 Star rating, metallic body complete all as specefied and directed. Make : Havells/Bajaj/CG/Usha
S&F Exhaust fan 200 mm sweep or nearest size, plastic body(Heavy duty), complete with louvers suitable for operation on 230 V AC, 50 Hz AC supply fixed on wall making opening,fixing and making good the distrubered surfaces etc complete all as specified and as directed.
S&F for tamper proof single phase energy meter (KWH) 20 to 40 Amp, 230 volts , digital display complete all as specefied and directed complete all as specefied and directed.
S&F concealed in wall Vertical DB double door TPN 4 way 415V, 50Hz double door, IP 43 protection with 200A rated bus bar , including provision of as incommer MCCB FP 40 Amp 10 ka and outgoing circuits complete, fill empty space with blank plates, making good the disturbed area as per existing surface complete all as specified and directed.
S&F Earth metal plug socket with MCB SP 25 Amp, 230 V AC, 50 Hz AC supply and making good the distrubered surfaces etc complete all as specIfied and directed.
Sub main wiring with 2 runs of single core 06 Sq.mm Single Core, FRLS, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including One run of 06 Sq.mm, Single Core, FRLS PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified. Note: 2 runs of 06 Sq.mm, 1 runs of 06 Sq.mm & one run of 20mm dia PVC Conduit will be measured as one unit
Sub main wiring with 2 runs of single core 04 Sq.mm Single Core, FRLS, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including One run of 04 Sq.mm, Single Core, FRLS PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified. Note: 2 runs of 04 Sq.mm, 1 runs of 04 Sq.mm & one run of 20mm dia PVC Conduit will be measured as one unit
Supply and fix TV sockets modular type with and inclusive of prefabricated modular box 2 mm thick of suitable size complete all as specIfied and directed.
Supply and fix Tele sockets modular type with and inclusive of prefabricated modular box 2 mm thick of suitable size complete all as specIfied and directed.
Earthing complete in positions with GI earth plate electrode of size 600x600x6mm thick buried directly in ground vertically to a depth of not less than 2.25m below ground level, with top edge of the earth plate at a depth of not less than 1.5m below ground connected to GI earth wire 4mm dia by means of GI bolts and nuts, check nuts, washers and GI earth wire protected by GI pipe light grade 15mm bore upto 7.5m and connecting to VCB's / transformer's etc., as per site requirement including necessary excavation, earth work in any type of soil, PCC M-10 type C-1, earth chamber, 50mm thick RCC M-20 cover with 6mm dia MS bars 10 cm C/C on both ways as reinforcement complete all as shown in electrical plate No.3 of MES SSR part-I complete all as specified and as directed including testing on completion and earth resistance shall not be more than 2 Ohm. Note: Quoted rate deemed to include necessary earth work, PCC chamber, RCC cover, reinforcement, removal of surplus soil, site clearance, etc., If desired earth resistance is not obtained, the contractor shall re-execute the earthing without any additional cost.
EXTERNAL WATER SUPPLY
Supply and lay ductile Iron pipe ,socket and spigot including specials, Class K7 100 mm (4”) dia. complete all as specefied and directed.
M & L Sluice valve, 100 mm bore , class PN-1.6, both side flanged,steel spindle complete all as specefied and directed.
M & L Sluice valve, 80 mm bore , class PN-1.6, both side flanged,steel spindle complete all as specefied and directed.
M & L Non return valve, 80 mm bore , class PN-1.5, both side flanged,steel spindle complete all as specefied and directed.
Construction of brick masonry valve chamber 90cm x 90cm x 120 cm inner dimension brick masonry in CM 1 :4 PCC base in 1:3:6 of 7.5 cm thick and plastering 15 cm thick in CM 1 : 4 in inner side/coping of all chamber fabrication of iron frame 40 x 40 x 6 mm size angle iron MS cover3 mm thick with hinges and locking arrangement duly painted including excavation earth work all complete all as specefied and directed.
Centrifugal pumps for 440 V, 3 Phase, 50 Hz Confirming to IS- 12469 :1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 volts, 3 phase, 50 Hz 36m head, 218 LPM discharge inclusive of PCC foundation complete all as specefied and directed.
Cutting the existing road for passing pipe and making good the disturbed surfaces by using 150mm thick 1:4:8 in foundation type D-2 ( using 40mm graded crushed stone aggregate) as in mass concrete complete all as specified and as directed.
Supply, install, test and commissioning of factory made LT Panel board (Distribution Panel) made out of CRCA sheet 2.0 mm thick indoor Pedestal type totally enclosed with front opening, hinged doors with projected and raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc used are to be made of rust proof material incl Aluminium bus bar with insulators suitable for three phase and neutral of capacity 100Amp, 50 Hz 415 V complete with powder coating, necessary internal electric connection as required and provision of the following: (for pump sets)
Incoming: MCCB AC 3 Phase 415 V, 50Hz 4 pole 100 A capactiy 25kA - 01 Nos Outgoing: a) MCCB AC 3 Phase 415 V, 50Hz 4 pole 40 A capactiy 16 kA - 03 Nos b) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs - 01 set c) MCB TPN 40 Amps 415 volts-02 Nos d) MCB SPN 20 Amps,240 volts- 02 Nos e) DOL starter for centrifugal pump set up to 5 HP capacity - 02 Nos f) LED indicating lamps with colour Red, Yellow, Blue - 03 Set
EXTERNAL ELECTRIFICATION
Supply, installation, commissioning and testing of LT panel board 440 volts, 3 phase, 4 wire, 50 cycle per second, AC supply comprising of 400 Amps capacity copper bus bar for the 3 phase and neutral, out door type of suitable size both side opening along with locking arrangement,rainguard canopy system, with ventilations fabricated out of steel sections i.e 3.00 mm thick CRCA sheet with angle iron of size 50x50x5mm thick . The construction of panel shall be dust and vermin proof with phosphatised powder coated painting externally and internally to protect against corrosion. The panel shall be mounted on 4 nos supporting Legs of size 60x60 cm and 6 mm thick 60 cm long fixing with 1:2:4 pcc,Digital multi function meters with necessary CTs complete with cable duct ground clearance 45 cm from grouting bolts with following accessories :-
(i) MCCB, 4 Pole,320 Amps,with microprocessor, 50 KA-01 No. (for Incoming) (ii) MCCB 4 Pole, 200 Amp,with microprocessor, 36 KA-01 Nos. (for outgoing) Spare. (iii) MCCB 4 Pole, 160 Amp,with microprocessor,35 KA-02 Nos. (for outgoing), for DG set supply pannel (iv) Indicator Lamp Set of 03 - 01 No
Supply, installation, commissioning and testing of LT panel board 440 volts, 3 phase, 4 wire, 50 cycle per second, AC supply comprising of 300 Amps capacity copper bus bar for the 3 phase and neutral, out door type of suitable size both side opening along with locking arrangement,rainguard canopy system, with ventilations fabricated out of steel sections i.e 3.00 mm thick CRCA sheet with angle iron of size 50x50x5mm thick . The construction of panel shall be dust and vermin proof with phosphatised powder coated painting externally and internally to protect against corrosion. The panel shall be mounted on 4 nos supporting Legs of size 60x60 cm and 6 mm thick 60 cm long fixing with 1:2:4 pcc,Digital multi function meters with necessary CTs complete with cable duct ground clearance 45 cm from grouting bolts with following accessories :-
(i) MCCB, 4 Pole,160 Amps,with microprocessor, 35 KA -01 No. (for Incoming) (ii) MCCB 4 Pole,125 Amp,with microprocessor, 35 KA -01 Nos. (for outgoing) Spare. (iii) MCCB 4 Pole,100 Amp,with microprocessor, 35 KA -02 Nos. (for outgoing), for DG set & Type-II Qtrs. 7 Fire fighting (iv) MCCB 4 Pole,63 Amp,with microprocessor, 25 KA -02 Nos. (for outgoing), for DG set & Type-II Qtrs.& Lift (v) Indicator Lamp Set of 03 - 01 No
Supply only chain link MS galvanisd fencing, any size or type complete all as specified and as directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and as directed.
Supply and fix 80 mm dia GI pipe for standards of height 2.6m chain link fencing including painting with 2 coats of synthetic enamel paint over a coat of red oxide including cost of excavation & earthwork refilling &PCC 1:2:4 type B1 as in foundation complete all as specified and as directed.
Supply, installing and testing of RMU 11KV 630A 21 KA 3 sec outdoor SF6 insulated VCB panel 02 Nos LBS as incoming ,02 Nos VCB as outgoing with metering equipments all as per IS/IEC-6227/200, chamber as per Internal Arc IAC-AFLR consisting of Plinth protection upto 1mt from grnd level as per OEM standards incl provision of steps, testing and commisioning should be carried out by OEM service Engineer all as per Engineer-in-Charge.Makes:ABB/Schneider/Seimens.
(b) Current Transformer 11 KV indoor resin cast CT: 300-150/1A, CI-5P10,2.5VA-9Nos, metering CTs:30-150/1A,CI-0.5,2.5VA-9 nos
(c) Bus Voltage transformer 11KV indoor resine cast fixed PT (11KV/rt3/110V/rt3) CI:0.5 burden:100VA
(d) Protection Devices: self powered O/C+E/F relay with instantaneous and IDMT characterstics Numerical type, High speed tripping relay(PQ8) for 86
(e) Metering and Indicating devices:- Multi function meter, ON/OFF/Trip/Trip ckt Healthy/ spring charged indiction lamps, VPIS for phase indication
(f) Panel Accessories: local/remoteswitch, Battery(2x12v,24ah) & Charger, control wiring as per norms/ colour code, control fuses, control MCBs, space heater/thermostat, disconnecting terminal blocks-Ct ckt, Terminal blocks- control ckt, Illumination lamp, toggle switch for heaterON/OFF
(g) Busbar Connectionswith 630 a copper bus bar, Earth connections- type tested for 21 KA STC
(h)Enclosure CRCAsuitable for outdoor(IP54) installation with the provision for receiving I/C, O/G cables through front and bottom entry, excluding termination kits and glands. 2mm CRCA sheet for inside sheets and covers, 3mm thick CRCA sheet for outer load encl.
(j) Load break switch : 11 KV, 630A, 21 KA/ 3 SEC ,Horizontal type draw-out with measuring CT and HT protetion fuse including indication lamps R,Y,B,Ammeter,voltmeter with Mechanical interlock all as specified and directed,
Shifting of existing 100KVA Transformer to New Location all as specified and as directed by Engineer-in-Charge.
Shifting of existing HT And LT Panel to location and connecting up all as specified and as directed by Engineer-in-Charge.
Supply, fixing new 48W LED street light fitting New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source and electronic driver with Gi pipe bracket all as specified and as directed
Supply & fixing pole mounting junction box for street light for 3 phase 4 core PVC of make sintex with internal size 230 x 170 x 105 mm comprising of PVC connector and MCB SP 6 Amp including mounting arrangement complete all as specified and as directed.
M&L for 1.5Sqmm 3 core PVC insulated unsheathed 1100 volts grade single core cable with copper conductor multi stranded from fitting to lpole box /OH comductor through the GI tubing bracket complete all as specified and directed.
Supply, install, test and commissioning of factory made, free standing floor mounted, dust and vermin proof Automatic Power Factor Correction panel,w out door type fabricated with 3.15 mm thik CRCA sheet with auto/manual option, compressing of suitable rated low loss MD-XL heavy duty hermetically sealed capacitor bank of 60 KVAR, connected in steps with capacitor rating (10 x 4Nos), (5 x 4Nos), KVAR complete with step contactor suitable for capacitor switchin with HRC fuses, backup protection, APFC relay 3 stage microprocessor based combinational switching type digital display of power factor, display of number of bank switches etc complete with all components and compressing the following items Make: Legrand/ L & T/ Siemens/ Neptune/ Schieneider and approved by CPRI. a) MCCB, 100 Amps 4 pole,415 volt, 25 KA qty -01 No b) Over voltage and under voltage relay- 01 N0 c) Phase indicating LED lamps. (RYB) for each capacitor d) Digital display unit showing power factor, voltage, current, frequency etc qty - 01 No e) On/Off push button for each capactor
Supply and fix LT/HT cable route indicator made out of 6 mm thick cast iron with angle section 25mmx25mmx3mm thick vertical support of 75 cm height.The indicator shall be embedded in PCC 1:2:4 type B1 (using 20 mm stone aggregate) complete all as specified and directed.
LIGHTENING PROTECTION/AVIATION LIGHT
M/L for providing earthing complete with GI earth plate electrode 600 mm x 600 mm x6.3mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level ,Alternate layers of charcoal) & common salt Crystal and connected to G I earth strip 32x6mm by means of bolts, nuts, check nuts & washers of copper and connecting to earth dolly all as shown in electrical plate No. 3of SSR Part I of 2009 & testing complete including 40mm dia light grade GI pipe upto 7.5mtr long, excavation in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm with frame, test box , including 20 mm bore water pipe medium grade GI Tubing including GI Funnel , wire mesh etc. ( NOTE :- Earth continuity conductor and GI protection pipe beyond 7.5m shall be measured and paid under the respective items ).all as directed by Engineer- in charge.
Supply and fix solid state electronic type aviation obstruction light fitting 10 watt LED with cast aluminium poly carbonate red colour, with connecting & testing complete on top of Buildings all as directed.
Supply and fix timer Switch Electronic Type including Necessary fitting connection all as as specified as directed.
FIRE FIGHTING SYSTEM
Supply and lay in trenches burnt clay fly ash Bricks sub class 'B' standard size for cable protection keeping width of the brick parallel to the length of the cable all as specified and directed.
Supply and spread clean dry river sand in trenches including leveling, punning for cushioning of cables complete all as specified and as directed. Note : Punned thickness of sand cushioning shall be measured.
Supply and fix hose reel of 20 mm dia with drum and 30 meter length conforming to IS 5132 complete all as specified and as directed.
Air release valve 25 mm dia male inlet made from gun metal and fixing on the top of MS wet riser of 100 mm dia. complete all as specified and as directed.
CI Flanged 'Y' type strainer including matching flanges , gaskets, nuts and bolts etc. For 100 mm dia wet riser pipe. complete all as specified and as directed.
Supply and fixing fire extinguisher Dry Powder(ABC) type of capacity 6kg complete all as specified and as directed.
Supply and fixing light weight squeeze grip type CO2 Extinguisher 4.5 Kg complete all as specified and as directed.
Material and labour for 2 run x 1.5 sqmm unarmoured FRLS cable through PVC conduit heavy duty including mounting complete all as specified and as directed.
Supply and fix dry powder based modular automatic fire suppression sytem of capacity 5 Kg complete all as specified and as directed.
DEMOLITION & DISMANTLING
Taking down old sub main wiring any type/ size including making good disturbed surface complete all as specified and as directed.
Taking down fan depositing to MES Store Yard any Size complete all as specified and as directed.
Taking down old Light Fitting any type/ size including making good disturbed surface complete all as specified and as directed.
Taking down GI pipe line not exceeding 40 mm dia in walls/trenches/ducts complete all as specified and as directed.
Design, supply, install, testing & commissioning passaenger lift , capacity of 13 passenger(884 Kg), speed 1.5 metre/sec with single speed motor, 415 volts, 3 phase AC 50 Hz supply, conforming to IS-14665 and as amended, suitable to serve G+04 upper floors with AC Variable Voltage & Variable Frequency Drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (03 Nos, one each in car, Machine room & near Ground floor landing door) complete, incl all civil works required with erectiion of lift incl auto fan ,LED Light emergency light all as specified incl the following: Note:(a)lAlarm speaker for alarm system to be fixed) ,stop button in car with rechargable arrangement for battery (b) four sleek circular LED light fitting in false ceiling (c) over Load working indicator both audio and visual type with tripping system having realy etc .(d)display indicating panel power controlcables (f) testing of govt approved lift insector (g)power factor control meter and capacitor banks to maintain PF above 0.95 (h) Marking on Lift,s pit and lift room (i) Mirror of 6mmthicness of suitable size on one wall inside the car complete all as specified and as directed.
Design, supply, install, testing & commissioning passaenger lift , capacity of 08 passenger(544 Kg), speed 1.5 metre/sec with single speed motor, 415 volts, 3 phase AC 50 Hz supply, conforming to IS-14665 and as amended, suitable to serve G+04 upper floors with AC Variable Voltage & Variable Frequency Drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (03 Nos, one each in car, Machine room & near Ground floor landing door) complete, incl all civil works required with erectiion of lift incl auto fan ,LED Light emergency light all as specified incl the following: Note:(a)lAlarm speaker for alarm system to be fixed) ,stop button in car with rechargable arrangement for battery (b) four sleek circular LED light fitting in false ceiling (c) over Load working indicator both audio and visual type with tripping system having realy etc .(d)display indicating panel power controlcables (f) testing of govt approved lift insector (g)power factor control meter and capacitor banks to maintain PF above 0.95 (h) Marking on Lift,s pit and lift room (i) Mirror of 6mm thickness of suitable size on one wall inside the car complete all as specified and as directed.
Supply & fix GI strip 32mm x 6 mm buried in ground complete all as specified and as directed.
Supply and lay cable XLPE insulated screened bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and as directed.
Supply & fix MCB DB TPN 4 Way double door with MCCB of cap 63/100A as incommer including necessary connecting up complete all as specified and as directed.
Supply & fix MCB TPN 40 Amp capacity 415 volt 16KA complete all as specified and as directed.
ARBORICULTURE
M&L for Poeta soil (garden soil) mixed with requisite quantity of pesticides and fertilizers while filling (stack measurements shall be considered for payment) complete all as specified and as directed.
M&L for dry gober manure mixed with requisite quantity of pesticides and filled along with the garden soil in alternate layers (stack measurements shall be considered for payment) complete all as specified and as directed.
Supply and Planting of hedges like Aakalita Aspar/Duranta varigated by digging in trenches of size 300mm wide and 300mm deep and filling soil obtained from same location upto 200mm height and balance 100mm depth filled with garden soil and manure mixed in the required proportion and planting hedges of height 300mm above GL and removal of soil, debris, weeds to a distance exc 250m and n.exc 500m and watering etc complete incl 3 months maintenance complete all as specified and as directed
Supply and Planting Semi studded plants like Golden Tum/Mananta varieties as per argus/mery aglonima draft varieties by digging in trenches of size 300mm wide and 300mm deep and filling garden soil and manure mixed in the required proportion and watering etc incl 3 month maintenance complete all as specified and as directed
S&F 20mm bore steel tubes, ‘medium grade’, galvanished with all fitting; laid in trenches complete all as specified and as directed
S& F 20mm dia. Gun-metal, glabe or gate valves, with iron wheel head, screwed both ends for iron pipe & fixed complete all as specified and as directed
DG SET
Supply and installation of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire,with AMF panel, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms and foundation etc. of capacity 50 KVA complete all as specified and as directed .
Supply, installation, commissioning and testing of LT panel board 440 volts, 3 phase, 4 wire, 50 cycle per second, AC supply comprising of 300 Amps capacity copper bus bar for the 3 phase and neutral, out door type of suitable size both side opening along with locking arrangement,rainguard canopy system, with ventillations fabricated out of steel sections i.e 3.0 mm thick CRCA sheet with angle iron of size 40x40x6mm thick . The construction of panel shall be dust and vermin proof with phosphatised powder coated painting externally and internally to protect against corrosion. with 1:2:4 pcc,Digital muli function meters with necessaty CTs complete with cable duct ground clearance 45 cm from grouting bolts with following accessories complete all as specified and as directed .
(i) MCCB 4 Pole, 100 Amp,with microprocessor,415 volt 35 KA -01 Nos ( for Incoming)
(ii) Chang Over switch,on load type, 4 Pole with advance neutral ,100 Amp,with microprocessor,415 volt .
(iii) MCCB 4 Pole, 63 Amp,with microprocessor,415 volt, 25 KA -02 Nos ( for outgoing) for type - II & type III Qtrs and one spare.
(iv) MCCB 4 Pole, 40 Amp,with microprocessor, 16 KA -01Nos ( for outgoing)
(v) Indicator Lamp Set of 03 - 01 No
Phase-II : Schedule 'A' Part -XVII COMPREHENSIVE MAINTENANCE:
Comprehensive maintenance of electrically operated passengers lift of capacity 13 passengers lift of capacity 884 Kgs all as mentioned vide Serial Item No. 83 of BOQ complete all specified in PS and as directed for First Year after expiry of Defects Liability Period of Two years.
Comprehensive maintenance of electrically operated passengers lift of capacity 08 passengers lift of capacity 544 Kgs all as mentioned vide Serial Item No. 84 of BOQ complete all specified in PS and as directed for First Year after expiry of Defects Liability Period of Two years. .
Phase-III : Schedule 'A' Part -XVIII COMPREHENSIVE MAINTENANCE:
Phase-III : Schedule 'A' Part -XVIII Comprehensive maintenance of electrically operated passengers lift of capacity 13 passengers lift of capacity 884 Kgs all as mentioned vide Serial Item No. 83 of BOQ complete all specified in PS and as directed for Second Year after expiry of Defects Liability Period of Two years.
Comprehensive maintenance of electrically operated passengers lift of capacity 08 passengers lift of capacity 544 Kgs all as mentioned vide Serial Item No. 84 of BOQ complete all specified in PS and as directed for Second Year after expiry of Defects Liability Period of Two years.
Phase-IV : Schedule 'A' Part -XIX COMPREHENSIVE MAINTENANCE:
Phase-IV : Schedule 'A' Part -XIX Comprehensive maintenance of electrically operated passengers lift of capacity 13 passengers lift of capacity 884 Kgs all as mentioned vide Serial Item No. 83 of BOQ complete all specified in PS and as directed for Third Year after expiry of Defects Liability Period of Two years.
Comprehensive maintenance of electrically operated passengers lift of capacity 08 passengers lift of capacity 544 Kgs all as mentioned vide Serial Item No. 84 of BOQ complete all specified in PS and as directed for Third Year after expiry of Defects Liability Period of Two years.
Notes for item No 93 to 98: (i) Comprehensive maintenance consists of preventive and breakdown services including replacement of material and labour for major/minor spare parts and consumables like topping of Oils/grease/door rollers/relays/door belts/gate lock contacts and hardware like bolts and nuts including load testing of lift for satisfactory performance once in a year complete and rate quoted by the tenderer includes for the above Lifts. (ii) Preventive maintenance consists of carrying out routine check by skilled personnel as specified in Particular specifications and as directed by Engineer-in-Charge and lubricating to all moving parts, topping parts, topping up of oils as per Lubrication Chart including Material and labour for all consumable and major/minor spare parts. (iii) Breakdown maintenance consists of attending to the faults that may occur and carrying out necessary repairs to electrical, control circuits and mechanical components including materials & labour for all minor & major spare parts and consumables of the lift that may occur during the operation.
(iv) Fortnightly, quarterly maintenance registers shall be maintained and signed by the site engineer and contractor. (v) Load testing shall be arranged by the contractor to the Lift for which repairs were carried out as and when directed by Engr -in-Charge. (vi) All maintenance works shall be carried out by well qualified tradesmen and supervisor of OEM. (vii) The quoted rate shall be deemed to be included the above aspect and for consumables such as timely toping up oils,acrylic covers, fuses, grease,waste cotton, stationery and other miscellaneous items and all minor & major spare parts. (viii) The tenderer shall submit MoU from the original manufacturer of the lift for comprehensive maintenance to undertake comprehensive maintenance during and after Defects Liability Period directly or through their nearest authorized/accredited agencies service personel. The MoU shall be submitted at least 06 months prior to issue of completion certificate of main contract as per Work Order No I.
lakshmibuilders
P S G CONSTRUCTIONS
HARI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .