Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹5.5 LAccepted-AOC SHOP NO 13 45 FEET ROAD BHARAT COLONY FARIDABAD HARYANA 121014 | FARIDABAD | HARYANA | 121014 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹6.9 L+₹1.3 L (23.4%)Rejected-AOC | L-2 | Rejected-AOC L-2 | |
| 3 | L-3₹8.2 L+₹2.7 L (47.8%)Rejected-AOC | L-3 | Rejected-AOC L-3 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
18 Aug 2022, 6:00 pmClosed
GE (AF) FARIDABAD
GE (AF) FARIDABAD
REPAIR / REPLACEMENT OF INTERNAL WIRING, REPAIR TO CEILING FAN/EXHAUST FAN, GEYSERS FITTINGS FIXTURES, MAIN DISTRIBUTION BOARDS, LIGHT FITTINGS ACCESSORIES CONVERSION WITH LED IN AF STATION FARIDABAD UNDER GE (AF) FARIDABAD
2022_MES_539812_1
GE (FBD)/AF-29/2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
FARIDABAD
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) FARIDABAD
₹20,000
Yes
3 Oct 2022
21 Jul 2022
20 Aug 2022
21 Jul 2022
18 Aug 2022
4 Aug 2022
21 Jul 2022 - 28 Jul 2022
Amount
Taking Down carefully Copper/aluminium Point Wiring (light, fan,socket or Power) complete,(fittings Such as switches, ceiling roses, pendents, regulators sockets etc, to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors et complete all as specified and directed by Engineer-in-Charge.
Taking Down carefully Copper/aluminium Point Wiring 4.0 sq mm ,removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer-in-Charge.
Taking down carefully copper / aluminum two core sub main wiring of sizes 6 Sqmm cable any type and removing old material from site and making good disurbed surface complete all as specified and directed by Engineer-in-Charge.
Taking down carefully copper / aluminum two core sub main wiring of sizes 4 Sqmm cable any type and removing old material from site and making good disurbed surface complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring in repairs complete with 1.5 sqmm single core multistranded copper conductor PVC insulated and unsheathed cable 1100 volts grade FRLS cable IS-694 marked drawn through and including rigid non metallic PVC heavy duty concealed conduit(min 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.12.5 of SSR Part I ) ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends.tees, juction boxes etc fixed concealed in wall/ceiling or surface conduit on ceiling with provision of 2 mm thick pressed steel terminal boxes covered with 3 mm thick plastic laminated white /coloured top cover for mounting switch,socket,fan regulator,industrial socket and all lamp fittings etc including 1.5 sq mm PVC insulated but unsheathed copper conductor FRLS cable,1100 volt grade IS-694 marked as earth contuinity wire for one light point/Fan point controlled by one,one way switch complete all as specified and directed by Engineer-in-Charge.
All as per Item No 5 mentioned here-in- before but one three pin 5 Amps socket out let on the same board with other switches with 1.5 sq mm PVC insulated copper conductor for continuous earthing complete all as specified and directed by Engineer-in-Charge.
All as per item No 5 mentioned here-in- before but one three pin 5 Amps socket out let on independant board with 1.5 sq mm PVC insulated copper conductor for continuous earthing complete all as specified and directed by Engineer-in-Charge.
All as per item No 5 mentioned here-in- before but 15 Amps 3 pin socket outlet on independent board with 2.5 sq mm PVC insulated and sheathed copper conductor with 2.5 sq mm PVC insulated copper conductor single core for continuous earthing complete all as specified and directed by Engineer-in-Charge.
All as per item No 5 mentioned here-in- before but for Single pole and neutral enclosure with 4.0 sq mm PVC insulated and sheathed copper conductor with 4 sq mm PVC insulated copper conductor single core for continuous earthing complete all as specified and directed by Engineer-in-Charge.
S&F Piano switch in repairs, flush button,single pole,one way 5/6 Amp complete all as specified and directed by Engineer-in-Charge.
S&F piano switch,in repairs, flush button single pole one way 15/16 Amp complete all as specified and directed by Engineer-in-Charge.
S&F bell push, in repairs, flush type 5 Amps complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet, in repairs,flush type 2 in 1, 2 pin and 3 pin 5 Amp complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet, in repairs,flush type 2 in 1, 3 pin and 6/16 Amp complete all as specified and directed by Engineer-in-Charge.
S&F stepped type electronic fan regulator, in repairs, flush type on the existing phenolic laminated sheet etc complete all as specified and directed by Engineer-in-Charge.
S&F in repairs,ceiling rose surface backlight, 65 x 50 mm two to to three terminals complete all as specified and directed by Engineer-in-Charge.
S & F in repairs Bell Multi Music type,240 V, complete all as specified and directed by Engineer-in-Charge.
Supply and fix Modular switch 1 way 6A, 1 module type, 230 volts, ISI marked complete. Make - As per sample complete all as specified and directed by Engineer-in-Charge.
Supply and fix Modular switch 2 way 6A, 1 module type, 230 volts, complete all as specified and directed by Engineer-in-Charge.
Supply and fix Modular Bell push 6A 1 module type, 230 volts,complete all as specified and directed by Engineer-in-Charge.
S & F Modular stepped type electronic fan regulator 2 Module, on the existing phenolic laminated sheet etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix Socket, 6A - 2/3 pin combined 2 module, multipurpose flush type, complete all as specified and directed by Engineer-in-Charge.
Supply and fix Socket 6A/16A - 2/3 pin combined 2 module, multipurpose flush type, complete all as specified and directed by Engineer-in-Charge.
Supply and fix Modular switch 1 way 16A, 1 module, multipurpose flush type, complete all as specified and directed by Engineer-in-Charge.
Supply and fix 8" x 6" hylem sheet 3 mm thick complete all as specified and directed by Engineer-in-Charge.
Supply and fix 7" x 4" hylem sheet 3 mm thick complete all as specified and directed by Engineer-in-Charge.
Supply and fix 4" x 4" hylem sheet 3 mm thick complete all as specified and directed by Engineer-in-Charge.
Supply and fix Switch flame proof rotary Type with termination box in LM6, 16A, single pole 250V complete all as specified and directed by Engineer-in-Charge.
Suppply and fix flame proof switch socket & plug combined in LM 6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified and directed by Engineer-in-Charge.
Supply and fix MODULAR WHITE COVER PLATE WITH FRAME 1 module complete all as specified and directed by Engineer-in-Charge.
Supply and fix MODULAR WHITE COVER PLATE WITH FRAME 2 module complete all as specified and directed by Engineer-in-Charge.
Supply and fix MODULAR WHITE COVER PLATE WITH FRAME 3 module complete all as specified and directed by Engineer-in-Charge.
Supply and fix MODULAR WHITE COVER PLATE WITH FRAME 4 module complete all as specified and directed by Engineer-in-Charge.
Supply and fix MODULAR WHITE COVER PLATE WITH FRAME 6 module complete all as specified and directed by Engineer-in-Charge.
Supply and fix MODULAR WHITE COVER PLATE WITH FRAME 8 module complete all as specified and directed by Engineer-in-Charge.
Supply and fix MODULAR METAL FLUSH BOX 3 module complete all as specified and directed by Engineer-in-Charge.
Supply and fix flushed inside the wall MS sunken box more than 1mm thicknes of size 4"x4" complete all as specified and directed by Engineer-in-Charge.
Supply and fix flushed inside the wall MS sunken box more than 1mm thicknes of size 7"x4" complete all as specified and directed by Engineer-in-Charge.
Supply and fix flushed inside the wall MS sunken box more than 1mm thicknes of size 8"x10" complete all as specified and directed by Engineer-in-Charge.
S&F in repairs,sheet metal enclosure for MCB DB's SPN 240 volts, 8 way with neutral bus bar 200 Amp rated double door type regal grey complete all as specified and directed by Engineer-in-Charge.
All as mentioned in item No 40 here in above but 12 ways DBs complete all as specified and directed by Engineer-in-Charge.
All as mentioned in item No 40 here in above but TPN DB, 4 ways DBs complete all as specified and directed by Engineer-in-Charge.
S&F in repairs,Single pole and neutral enclosure with a two pin and earth plug and socketcomplete with one single pole MCB 32 Amp complete all as specified and directed by Engineer-in-Charge.
M&L in repairs,two single core PVC insulated cable with copper conductor multi stranded 6 Sqmm duly drawn through and including concealed PVC conduit uitable size as sub main with continuous earth wire 6 Sqmm size and connecting to common earth dolly complete all as specified and directed by Engineer-in-Charge.(Flexible Copper Wire Used In FRLS)
All as per item No 44 mentioned here-in- before but 4.0 sq mm PVC insulated and sheathed copper conductor with 4 sq mm PVC insulated copper conductor single core for continuous earthing complete all as specified and directed by Engineer-in-Charge.
S&F in repairs MCB SP 6 to 32 Amps 240 Volts."B" grade complete all as specified and directed by Engineer-in-Charge.
S&F in repairs MCB,SP 40 Amps, 240 Volts."B" grade complete all as specified and directed by Engineer-in-Charge.
S&F in repairs MCB,SPN 6-32 Amps, 240Volts,"B" grade complete all as specified and directed by Engineer-in-Charge.
S&F in repairs MCB SPN, 40 Amps, 240Volts ."B" grade complete all as specified and directed by Engineer-in-Charge.
S&F in repairs MCB SPN, 63 Amps, 240Volts."B" grade complete all as specified and directed by Engineer-in-Charge.
S&F in repairs MCB TPN 40 Amps,415Volts ."B" grade complete all as specified and directed by Engineer-in-Charge.
S&F in repairs MCB TPN, 63 Amps,415Volts ."B" grade complete all as specified and directed by Engineer-in-Charge.
S&F in repairs,LED tube light batten 22W LED,6000K (4 ft.), 230 volts AC,Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver connector block,lamp etc complete with all accessories, internally pre-wired including twin core twisted flexible copper conductor of suitable size with PF -0.95,THD-10%,driver should be of same make as LED fitting,with in build over voltage ,under voltage and short circuit protection with operating range of 140 volst to 280 volts,isolation LED driver complete all as specified and directed by Engr-in-Charge
S&F in repairs,LED tube light batten,12W(+) 2% LED 6000K (2 ft.), 230 volts AC,Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver connector block,lamp etc complete with all accessories, internally pre-wired including twin core twisted flexible copper conductor of suitable size with PF -0.95,THD-10%,driver should be of same make as LED fitting,with in build over voltage ,under voltage and short circuit protection with operating range of 140 volst to 280 volts,isolation LED driver complete all as specified and directed by Engr-in-Charge
S&F in repairs,LED false ceiling panel fittings ,1x45W/1x40W LED 6000K (2ftx2ft.), 230 volts AC,suitable for false ceiling, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver connector block,lamp etc complete with all accessories, internally pre-wired including twin core twisted flexible copper conductor of suitable size with PF -0.95,THD-10%,driver should be of same make as LED fitting,with in build over voltage ,under voltage and short circuit protection with operating range of 140 volst to 280 volts,isolation LED driver complete all as specified and directed by Engr-in-charge
Supply and fixing LED Lamp 20 Watts with suitable to replace 36/40 Watts FTL,high Efficiency PMMA diffuser soft glare free light complete and including provision of three core textile braided copper conductor flexible wire from ceiling rose to light fitting complete all as specified and directed by Engineer-in-Charge.
Taking down ceiling fan complete any type size from existing location and cleaning body blades etc including greasing,oiling,replacing wornout bearing ,bush and refixing the same at site ccomplete all as specified and directed by Engineer-in-Charge.
All as mentioned in item No 57 here in above but for Exhaust fan 300 mm sweep complete all as specified and directed by Engineer-in-Charge.
All as mentioned in item No 57 here in above but for Exhaust fan 450 mm sweep complete all as specified and directed by Engineer-in-Charge.
All as mentioned in item No 57 here in above but for wall/floor mounted fan 450 mm sweep complete all as specified and directed by Engineer-in-Charge.
Rewinding unserviceable ceiling fan 1200/1400 mm Sweep from site by strip opening,cutting removing the burnt winding from starter cleaning the slots and rewind the same with original guage of super enameled copper winding wire, insulation materials and all accessories & varnishing etc replacement of service wire copper twisted size 23/0.0076 including reassembling the fan complete all as specified and as directed by Engr-in-Charge.
All as mentioned in item No 69 here in above but for Exhaust fan 300 mm sweep complete
All as mentioned in item No 69 here in above but for Exhaust fan 450 mm sweep complete
All as mentioned in item No 69 here in above but for wall/floor mounted fan 450 mm sweep complete
S&F in repairs Capacitor 2.5 mfd suitable for Ceiling Fan/Wall fan/Exhaust Fan complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Capacitor 3.15 mfd suitable for Ceiling Fan/Wall fan/Exhaust Fan complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Capacitor 4.0 mfd suitable for Ceiling Fan/Wall fan/Exhaust Fan complete all as specified and directed by Engineer-in-Charge.
Supply only ball bearing for 1200/1400mm sweep Make;- TATA / SKF/NBC complete all as specified and directed by Engineer-in-Charge.
Supply only FR PVC electrical insulation tape,1.8 cm x 25 mtr x0.125 mm thick complete all as specified and directed by Engineer-in-Charge.
S&F ceiling fan down rod 15 mm bore 45 cm long including cutting and threading suitable for hanging of ceiling fan 1200mm/1400mm sweep
S&F ceiling fan down rod 15 mm bore 2 mtr long including cutting and threading suitable for hanging of ceiling fan 1200mm/1400mm sweep complete all as specified and directed by Engineer-in-Charge.
S&F battery 12V 150 AH testing after installation complete all as specified and directed by Engineer-in-Charge.
Supply and fix Ventilation fan (300 mm Sweep) with louvers and acessories complete all as specified and directed by Engineer-in-Charge.
Taking down storage water heater 25/50 ltrs capacity from wall for repair/replacement of unserviceable parts and refixing with fasterners Nuts and washers the same after repair work complete all as specified and directed by Engineer-in-Charge.
Supply only split plate for 25 litrs capacity geyser as per site requirement and made out of 20 gauge MS sheet complete all as specified and directed by Engineer-in-Charge.
Supply only geyser bottom cover made out of 20 SWG MS sheet, duly painted with one coat of red oxide primer and two coat of first quality super enamalled white paint for 25 liters capacity geyser complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of thermostate 0-60 degree as per sample in water geyser 25/50 litre capacity complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of heating element 1.5KW,Triangular/round type complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of heating element 2 KW Triangle/Circular type complete all as specified and directed by Engineer-in-Charge.
Material and Labour for disconnecting from electric and water mains and dismantling the unserviceable gyeser base assembly and replacing the new base assembly 6/9 holes with rubber gasket for 25 Ltrs capacity of any make and refixing in original place including recoonecting of electric and water supply mains including testing complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of geyser outer body cover of 25 Ltr capacity made out of 20 SWG MS Sheet, duly painted with one coat of red oxide primer and two coat of first quality super enamalled light white paint complete with all connected accessories suitably fitted with existing wall complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of geyser tank stainless steel suitable for 25 Ltr capacity geyser complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of PVC connection with brass inserts suitable for hot/cold water, 60 cm long (for hot and cold water inlet and outlet) having nuts with washer complete all as specified and directed by Engineer-in-Charge.
Dismantling and opening storage tank of geyser 25/50 litre capacity to identify the leakage ,repair the spot by suitable welding carefully including making good insulating material, assembling and testing complete all as specified and directed by Engineer-in-Charge.
NAVYUG VYAPARI
laxmi enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .