Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | Qualified Make: CyberPower
Model: CyberPower UT2200E-IN 3A GANDHI NAGAR 3A IST FLOOR OPPOSITE CHURCH GANDHI NAGAR JAMMU JAMMU JAMMU KASHMIR 180004 | JAMMU | JAMMU AND KASHMIR | 180004 | Make: CyberPower
Model: CyberPower UT2200E-IN | - | Qualified | |
| 2 | L1₹8,142Disqualified Make: Uniline
Model: UNILINE SMARTLINE-1K-168 5 A A GANDHI NAGAR 5 A A NEAR POLICE STATION ON NATIONAL HIGHWAY GANDHI NAGAR JAMMU JAMMU JAMMU AND KASHMIR 180004 | JAMMU | JAMMU AND KASHMIR | 180004 | Make: Uniline
Model: UNILINE SMARTLINE-1K-168 | L1 | Disqualified | |
| 3 | Disqualified Make: zebronic
Model: ZEBRONICS U1200 2 RANA SAMAY SINGH DURG MAHARANA PRATAPGARH KAKROLA VILLAGE SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | Make: zebronic
Model: ZEBRONICS U1200 | - | Disqualified | |
| 4 | Disqualified Make: APC
Model: APC BACK FRTE UPS 1.1KVA BX-1100C-IN B 163 SUPER BAZAR NAVDEEP HOUSE NEAR INCOME TAX CROSS ROAD ASHRAM ROAD AHMEDABAD AHMEDABAD CITY GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | Make: APC
Model: APC BACK FRTE UPS 1.1KVA BX-1100C-IN | - | Disqualified | |
| 5 | Disqualified Make: Zebronices
Model: ZEBRRONICS 1KVA 15 DONGRO DODA MOHELEA DODA JAMMU KASHMIR 182201 | DODA | JAMMU AND KASHMIR | 182201 | Make: Zebronices
Model: ZEBRRONICS 1KVA | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
20 Aug 2018, 12:00 pmClosed
Line Intractive UPS with AVR Line Intractive UPS With AVR ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 2.0/1600 As per GeM Catalogue. Technology MOSFET-PWM MOSFET-PWM
IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 Rated Output (Volt) Single phase sinewave 230v AC
50Hz Single phase sinewave 230v AC
50Hz
Single Phase Quasi-Sin-wave 230 V AC
50 Hz Degree of protection IP-21 IP-21
IP 20 Inverter Efficiency (%) >/= 60% >/= 60%
>/= 70% Warranty for the battery from the date of delivery 1 year 1 year
3 Years Warranty for Line Interactive UPS 1 Year 1 Year
2 Years
5 Years
3 Years Installation and commissioning instructions Yes - CONSTRUCTIONAL Type of enclosure ABS - AC out put for Yes Yes
No 1/3 printer (not through inverter) Inverter out put socket AC out put for printer (not through inverter) 3 Three pin 2 Three pin
3 Three pin
Hard wiring
Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9%
50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts
the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree
RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes - Dry heat Test at 45 Yes - 2/3 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date - - Name Of Lab - - Address of Lab - - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Meyiwabang Longkumer 193224
160 Inf Bn TA (H &H) JAKRIF C/O 56 APO 1 60
399130
GEM/2018/B/56492
Line Intractive UPS with AVR
60 days
Jammu And Kashmir; Kupwara
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Line Intractive UPS with AVR Line Intractive UPS With AVR ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 2.0/1600 As per GeM Catalogue. Technology MOSFET-PWM MOSFET-PWM | - | - | - |
| IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 Rated Output (Volt) Single phase sinewave 230v AC | - | - | - |
| 50Hz Single phase sinewave 230v AC | - | - | - |
| 50Hz | - | - | - |
| Single Phase Quasi-Sin-wave 230 V AC | - | - | - |
| 50 Hz Degree of protection IP-21 IP-21 | - | - | - |
| IP 20 Inverter Efficiency (%) >/= 60% >/= 60% | - | - | - |
| >/= 70% Warranty for the battery from the date of delivery 1 year 1 year | - | - | - |
| 3 Years Warranty for Line Interactive UPS 1 Year 1 Year | - | - | - |
| 2 Years | - | - | - |
| 5 Years | - | - | - |
| 3 Years Installation and commissioning instructions Yes - CONSTRUCTIONAL Type of enclosure ABS - AC out put for Yes Yes | - | - | - |
| No 1/3 printer (not through inverter) Inverter out put socket AC out put for printer (not through inverter) 3 Three pin 2 Three pin | - | - | - |
| 3 Three pin | - | - | - |
| Hard wiring | - | - | - |
| Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9% | - | - | - |
| 50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts | - | - | - |
| the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree | - | - | - |
| RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes - Dry heat Test at 45 Yes - 2/3 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date - - Name Of Lab - - Address of Lab - - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Meyiwabang Longkumer 193224 | - | - | - |
| 160 Inf Bn TA (H &H) JAKRIF C/O 56 APO 1 60 | - | - | - |
Exempted
20 Aug 2018
30 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_399130.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .