| 1 | L1₹4.7 LAccepted-AOC 12 HAJI MD MOHASIN SQUARE KOL 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | L1 | Accepted-AOC LOWEST Bid Value | |
| 2 | L2₹5.8 L+₹1.0 L (22.3%)Rejected-Finance SRINIKETAN ROAD BOLPUR BIRBHUM 731204 | BOLPUR | BIRBHUM | WEST BENGAL | 731204 | L2 | Rejected-Finance HIGHER Bid Value | |
| 3 | L3₹5.9 L+₹1.1 L (24.2%)Rejected-Finance | L3 | Rejected-Finance HIGHER Bid Value |
Tender Value
₹5.8 L
EMD Value
₹11,634
Closing Date
3 Jul 2024, 1:05 pmClosed
Assistant Engineer, PWD, NMCH Electrical Sub-Divn.
O/O The Asst. Engr., PWD, NMCH Elect. Sub-Divn.
SITC of AC at Auditorium Hall
2024_WBPWD_689979_1
WBPWD/AE/eNIT01/2024-25
Open Tender
A/C ORG
Item Rate
20 days
CNMCH
Please refer Tender documents.
4 documents required · 4 mandatory
₹11,634
O/O The Asst. Engr., PWD, NMCH Elect. Sub-Divn.
9 Jan 2025
7 Jun 2024
5 Jul 2024
7 Jun 2024
3 Jul 2024
14 Jun 2024
14 Jun 2024
Amount
Supply & Delivery of 230V,1-Ph, 50Hz, 2Tr. capacity Concealed Split Air Conditioning Machine along with 1 no. IDU of rated Cooling Capacity:- 24000 BTU/HR, Compressor:- Rotary Type, Remote Control:- Yes, Condenser Coil:- Copper, Refrigerant Type:- R-410A/R-32, Air Flow/IDU:- 800CFM, Operating Mode:- Cool & Fan Mode, Sleep Mode:- Yes, Timer:- Yes. (Make:- Daikin/Voltas/Hitachi/O General)
Supply & Delivery of 415V,3-Ph, 50Hz, 4.6Tr. Floor Standing Air Conditioning Machine of rated Cooling Capacity:- 550000 BTU/HR, Compressor:- Rotary Type, Remote Control:- Yes, Condenser Coil:- Copper, Refrigerant Type:- R-410A/R-32, Air Flow/IDU:- High- 1170CFM, Medium- 1085CFM, Low- 985CFM, Operating Mode:- Cool & Fan Mode, Sleep Mode:- Yes, Timer:- Yes. (Make:- Daikin/Voltas/Hitachi/O General)
Lifting,Shifting,Installation,Testing & Commissioning of IDU & ODU of Floor Standing Air Conditioning Machine with a specific focus on the installation of indoor units utilizing angle iron structures where necessary.S&F of necy. fixing arrangement for indoor & Outdoor duly painted etc. as per direction of EIC if required after making hole in wall on mending good the damages to the original finish as required & necy. scaffolding arrangement incl. lifting Outdoor and Indoor unit,labour cost etc.on both side(IDU & ODU Installation), Supply of required Refrigerant R-410A/R-32,Cutting of holes in wall for laying of copper pipe lines (If required) & mending good the damages to the original finish..
Installation, Testing & Commissioning of Indoor & Outdoor unit of the following capacity concealed type Split Air Conditioners after making hole in wall & necessary scaffolding arrangement etc as per site condition & direction of EIC including Supply of required Refrigerant as per the manufacturer specifications, S&F of necessary fixing arrangement for indoor duly painted etc as per direction of the EIC.
Supplying fabrication & fixing of 2nos U-Channel (TATA Make) of size (50 mm x 50mm x 6mm thick) for making platform for instalation of outdoor unit incl. drilling 2nos holes in each channel as per site condition & as per direction of EIC. incl. cutting holes into the wall & grouting the same with cement concrete (1:1 %1/2: 3) etc incl. mending as orginal and fabricated with horizontal angle of 25 mm x 25 mm x 6mm including supporting angle 50 mm x50mm x 6mm in each platform in outer edge for transmitting the load centrally through 2Nos (50 mm x50 mm x 6 mm) Angle inserted to the exiting wall The entire structure should be baricated & safe for ODU maintenance Area of the platform is 2Mx1.2M or as per Machine configuration & load with adequate service access as per direction of EIC. (Structural design should be approved by E.I.C.)
Supply and fixing of AI powder coated continuous Grill (Make- Premier, Dynacraft/ EIC approved.)
Supply & Laying of soft drawn Copper pipe line with 0.6 mm or 0.7 mm (min) thick for Liquid Line and Suction Liine between ODU and IDU with fittings, elbows, bends, supports & brackets (Make-Ryoku/Hitachi/Nippon)
Liquid Line 3/8" (9.52mm) Dia or as per manufacturer specification)
Gas Line/Suction Line 5/8" (15.88mm) Dia or as per manufacturer specification)
Supply & Fixing Pipe Insulation of Liquid Line and Suction Liine with 9 mm thick nitrile rubber tube also wraping the insulation & copper wire with GKB Gold non adhesive raping tape (Make:- Accoflex/ Armacell/ Supreme)
Liquid Line 3/8" (9.52mm) Dia or as per manufacturer specification)
Gas Line/Suction Line 5/8" (15.88mm) Dia or as per manufacturer specification)
Supply and laying 4 core 2.5 sq mm control copper cable (PVC insulated & unshethed,un-armoured) from Condensing Unit to IDU control panel. (Make: Gloster/ Havells/ RR Kable / Finolex/ Polycab)
Supply and laying of Drain Water piping work out of UPVC hard pipes of following sizes incl. nitrile insulation with fiting accessories bends, elbows, tees flanges, tapings, wall sleeves hangers, supports, anchors etc. as required.(Make : Supreme / Astral/ EIC approved).
25 mm dia.
Supply and Charging Extra R 410A/R-32 Refrigarent due to long distance Between Indoor & Outdoor Unit.
Hiring Charge of Scafolding Arrangements for installation of all the Indoor & Outdoor Units.
Note: 1) All the above rates should be quoted inclusive of the all taxes, duties & cess with cost of maintenance, servicing, supply & replacement of spares for 1 (One) year from the date of commissioning. 2) Total is rounded off to the nearest rupee and inclusive of all taxes, duties & cess on total amount of above items (i.e. from item Sl. No. 1.00 to item Sl. No. 12.00) as applicable.
RAMKRISHNA ELECTRONICS
BURDWAN REFRIGARATION SERVICE
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .