Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹17.1 LAccepted-AOC 2ND FLOOR SHOP NO 303 MARUTI PLAZA RONCHI BANGAR TOWNSHIP MATHURA | MATHURA | UTTAR PRADESH | 281001 | 1 | Accepted-AOC L1 | |
| 2 | 2₹18.9 L+₹30,138 (1.62%)Rejected-AOC GMD ROAD MORADABAD MORADABAD UTTAR PRADESH 244001 | MORADABAD | UTTAR PRADESH | 244001 | 2 | Rejected-AOC L2 | |
| 3 | 3₹20.2 L+₹1.6 L (8.51%)Rejected-AOC | 3 | Rejected-AOC L3 |
Tender Value
₹18.7 L
EMD Value
₹19,000
Closing Date
2 Sept 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Electricity Transmission Circle-II, U.P. Power Transmission Corporation Ltd. 57- George Town, Prayagraj
38/ETC-II(P)/ 2021-2022
2021_UPTCL_614348_1
38/ETC-II(P)/ 2021-2022
Open Tender
Electrical Works
Item Rate
90 days
Jari
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,360
EE,ETD-NAINI,ALLAHABAD
₹19,000
3 Dec 2021
27 Aug 2021
3 Sept 2021
27 Aug 2021
2 Sept 2021
27 Aug 2021
120 days
Amount
Part "A" Supply of Hardware & fittings
Supply of bolted type tension fitting with all accessories for single Moose conductor for Solar Bay as per sample.
Supply of bolted type tension fitting with all accessories for single Panther conductor for Solar Bay as per sample.
Supply of post insulator clamp duly made of LM-6 Alluminium Alloy suitable for single panther conductor complete with GI nuts, bolts, spring & washer as per sample.
Supply of PG clamp duly made of LM-6 Allu. Alloy suitable for ACSR Moose to Panther conductor complete with 04 no. 16x75 mm size GI bolts, nuts, spring & plane washer as per sample.
Supply of PG clamp duly made of LM-6 Allu. Alloy suitable for ACSR Moose to Moose conductor complete with 04 no. 16x75 mm size GI bolts, nuts, spring & plane washer as per sample.
Supply of PG clamp duly made of LM-6 Allu. Alloy suitable for ACSR Panther to Panther conductor complete with 04 no. 16x75 mm size GI bolts, nuts, spring & plane washer as per sample.
Supply of 132 KV Isolator terminal clamp made of LM-6 Alluminum Alloy suitable for single panther conductor complete with GI nut & bolts and washers.
Supply of 132 KV Isolator terminal clamp made of LM-6 Alluminum Alloy suitable for ACSR Moose conductor complete with GI nut & bolts and washers.
Supply of 132 KV Tendam Isolator bimetalic terminal clamp made of LM-6 Alluminum Alloy suitable for single ACSR Panther conductor complete with GI nut&bolts and washers.
Supply of 02 no. U Bolted Type Single suspenstion fitting assembly suitable for single ACSR Moose conductors complete with hardware fitting, socket eye, Ball Hook, Yoke Plate, J-Hook etc. as per technical specification as per sample.
Supply of 02 no. U Bolted Type Single suspenstion fitting assembly suitable for single ACSR Panther conductors complete with hardware fitting, socket eye, Ball Hook, Yoke Plate, J-Hook etc. as per technical specification as per sample.
Supply of U Bolt 20 mm dia with double nuts, bolts and washer.
Part "B" Work
Construction of 01 no. 132 KV Tata Solar Bay after re-location of 132 KV Bus coupler bay at 132 KV S/S Jari, Prayagraj. The supply/work includes the following:-
Shorting, shifting & loading of galvanized material on private vehicle at Electy. Fabrication Unit Naini, Prayagraj.
Safely carriage of substation structure from Electy. Fabrication Unit Naini to 132 KV S/S Jari on private vehicle (per truck basis).
Unloading, shorting, shifting & stacking in proper order as per member wise of above material at 132 KV S/S Jari, Prayagraj.
Opening of existing jumper of 132 KV Bus coupler bay including shifting of jumper from work site to store.
Opening and re-connection of control cable termination of 132 KV Shankargarh-Masauli-I & II feeder bays from switchyard to control/ relay panel and energy meter.
Dismantling of existing equipments/structures of 132 KV Bus coupler bay including shifting of material from work place to store place.
BCT Structure
132 KV Isolator
Erection of following structure & equipments including their shifting from storage place at the sub-station to erection site :-
Lattice type auxilliary structure
145 KV CT/PT
145 KV CT/PT Junction box
145 KV SF-6 Circuit Breaker
145 KV Tandem Isolator with Post Insulator
145 KV Line/Bus Isolator with Post Insulator
145 Control & Relay Panel (scada base)
Stringing of 3-phase Jack bus bar of with ACSR Moose conductor between 132 KV main bus-I to main bus-II (01 job per phase).
Jumpering of equipments of various 132 KV equipments with main bus-I & main bus-II, Jack bus, transfer bus of ACSR Moose/Panther conductor the work includes measuring, cutting and bending of conductor in proper shape & size, clamping with the help of suitable clamp and all associated work to complete the work satisfactorily.
Earthing by Cutting, Straightening & Laying 500 mm below Inside Ground & above Ground of Following sizes M.S. Flat to Provided by the Department for Diagonal/Double Earthing of the Main & Aux. Structures, Equipments and Cable Trenches including Welding with Main Earth Mat and with the Object to be Earthed including Excavation of Trenches & its Back Filling etc. as per Details below :-
Earthing of LA with 75x10 mm of size MS Flat.
Earthing of Main & auxiliary structure and equipments (CBs, Isolators, CTs, PTs, C&R Panel, DPP, Junction Boxes etc. with 50x6 mm size M.S. Flat of (Solar bay and bus coupler).
Earthing of cable trench with 25mm x 6mm/ 25x5mm size M.S. Flat.
Making of Shielding Mesh earthing for 132 KV LAs of solar bay by Fabrication of 06 No. 3 Meter Long Electrodes with 36 mm dia. M.S. Round Bar having 150 mm long Conical Shape and then its Piercing Vertically in the Ground with Top 500 mm below Ground Level, Jointing the Electrodes with 75 × 10 mm size M.S. Flat by Welding for making of Mesh, Connecting the Shielding Mesh with Main Earth Mat at 2 Places and finally, Painting of the Shielding Mesh / Earthing Strips with Anti-Corrosive Paint, with due Digging of Earth / Trench & its Back Filling. (1 Job per Bay)
Laying of Following sizes Control Cables in Cable Trenches from Control & Relay Panels in Control Room to various Equipments, Junctions Boxes etc. in Switchyard as per Cable Schedule including Shifting of Cables in Drums from Storage Place at the Sub Station to Erection Site and Shifting Back the Balance Cables to Stores at the Sub Station :-
Interconnection & termination of various sizes above laid control cables with new 132 KV solar bay, Masauli Ckt.-I bay and bus coupler bay from C&R Panel to various equipments etc. and other associated work to complete the job.
Providing & fixing of name plate made of 02 mm thick aluminium Sheets with covering of 3HP retro reflective sheeting of size 300mmX150mm plate to be fixed with the help of nuts & bolts of already installed equipment's structure as per sample.
Providing & fixing of phase plate equipment (R,Y,B phase of 02 mm thick aluminium sheets of size 5" dia covering of 3M HIP/MDG retro reflected sheet in single piece with all mounting with GI nut and bolts after opening of old rusted and damaged phase plate (01 set = R,Y,B Phase).
Providing & Fixing of 150 Watt L.E.D. Switchyard Light Luminaries Fittings of Philips / Compton Greaves / Havells make in Single Piece Die Cast Aluminium Alloy Housing with Pot Optics Reflector & Toughened Clear Glass Cover with Frame for Lamp Compartment inlcuding Cable Terminations. The work includes the cost of men, material & T&P required.
Scada related work detail given below:-
Configuration/Programming in IEC61850 based protocols, creating of data base and data set points from respective bay control Units (BCUs) AND Relays for changing name of existing 132 KV Masauli-I & II Bay .
Network topology configuration for checking the healthness of BCUs & Relays.
Event/alarm & reports creation in the SCADA HMI_I & II. System configuration as per the client and server topology in Main MHI-I and Reduandt HMI-II.
Configuration of soft logies & Goose messaging in the SCADA HMI.
Checking Device status in server cum gateway and updating firmware.
Updating firmware for all SCADA system for smooth communication.
SCADA Local operation testing with respective to feeders from Main HMI-I and Reduntant SCADA HMI-II.
SCADA integration of existing 132 KV Shankargarh Bay & 132 KV Solar Bay in the existing Siemens make SAS.
Configuration of one no. of port in SAS panel (Siemens make) for data transmitting to SLDC Lucknow.
Carriage of dismantled/balance material from site to store and fresh consumable material from store to work site.
M/S SATKAR TRADERS
A.RAMAN POWER ENGINEERS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .