Loading…
Loading…
Tender Value
₹12.1 L
EMD Value
₹24,200
Closing Date
20 Mar 2026, 12:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Revenue
TL AND AC
13 conditions · 2 needing a document upload
Not Applicable
ELECTRICAL LICENSE (MANDATORY): - The contractors should have to submit valid electrical contractor license along with his offer issued by any state Govt., under compilation of clause 45 of Indian Electricity Rule 1956 or as amended from time to time. Electrical Contractors license shall be submitted along with the offer, failing which the offer will summarily be rejected.
28 conditions
Details of organization. {The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society / Registered Trust / Hindu Undivided Family (HUF) /Limited Liability Partnership (LLP) etc. The tenderer(s) shall enclose the attested copies of the constitution of their concern and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust, or society, as the case may be}.
The tenderer whether sole proprietor / a company or a partnership firm/registered society / registered trust / HUF / LLP etc if they want to actthrough agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, specifically authorizing him/them to sign the tender, submit the tender and further to deal with the Tender/ Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association/Board resolution, failing which tender shall be summarily rejected
In case of other than Company/Proprietary firm, Annexure -F (Annexure- V(A) of GCC) shall be submitted by the each member of a Partnership firm/ Joint Venture(JV)/ Hindu Undivided Family (HUF)/Limited Liability Partnership (LLP) etc. as the case may be. Non-submission of above certificate(s) by the bidder shall result in summarily rejection of his/their bid. It shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self-attested/ digitally signed by which they/he is qualifying the Qualifying Criteria mentioned in the Tender Document. (GCC- April-2022 with upto date correction slips).
ELECTRICAL LICENSE (MANDATORY) :- The contractors should have to submit valid electrical contractor license along with his offer issued by any state Govt., under compilation of clause 45 of Indian Electricity Rule 1956 or as amended from time to time. Electrical Contractors license shall be submitted along with the offer, failing which the offer will summarily be rejected.
Scanned copy of payment receipt of Bid Security (EMD) submission. Documentary proof must be submitted by tenderer in case of exemption claimed for Bid Security.
Tender Form (First sheet) duly filled in along with the bid offer.
Tenderer has to submit the documents as per Annexure attached (whichever is applicable) along with the bid offer.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Provision of wiring arrangement with panel, cable laying work, distribution boxes for 27 nos. Split AC in Administrative building & RPF barrack at CRW/HRT.
MRS-CRW-HRT-28-RT-1
MRS-CRW-HRT-28-RT-1
Open
Works - General
4 Months
Nalanda, Bihar
₹0
₹24,200
20 Mar 2026
27 Feb 2026
6 Mar 2026
37 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 12,07,876.22 | ||
| — | — | — | 3,450 | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of size above 185 sq. mm and upto 400 sq. mm in the existing masonry open duct as required | — | 30.00 | — | — | |
| — | — | — | 1,29,350 | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of size Above 35 sq. mm and upto 95 sq. mm (Clamped with 25 x 3mm MS flat clamp) on wall surface as required | — | 995.00 | — | — | |
| — | — | — | 7,910 | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of size Above 185 sq. mm and upto 400 sq. mm (Clamped with 40 x 3mm MS flat clamp)on wall surface as required | — | 35.00 | — | — | |
| — | — | — | 72,048 | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of size Above 185 sq. mm and upto 400 sq. mm direct in ground including excavation , sand cushioning ,protective covering and refilling the trench etc. as required | — | 152.00 | — | — | |
| — | — | — | 4,556 | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of size Above 185 sq. mm and upto 400 sq. mm in existing RCC/HUME/METAL pipe as required | — | 34.00 | — | — | |
| — | — | — | 9,196 | ||
| Supply and making end termination with brass compression gland and aluminium lugs for size of 4 X 50 sq.mm. (35mm.) PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1KV grade as required. Make : Raychem/3M,/Denson or similar | — | 22.00 | — | — | |
| — | — | — | 4,108 | ||
| Supply and making end termination with brass compression gland and aluminium lugs for size of 3.5 X 240 sq.mm. (45mm PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1KV grade as required. Make:: Raychem/3M,/Denson or similar | — | 4.00 | — | — | |
| — | — | — | 1,03,577.6 | ||
| Horizontal drilling bore for HT/LT cables. | — | 34.00 | — | — | |
| — | — | — | 51,658.24 | ||
| Supply and erection of GI pipe of 150mm dia of "B" class. Make : Jindal/ Tata/ Surya Prakash/ Swastik or simlilar | — | 34.00 | — | — | |
| — | — | — | 82,632 | ||
| Supply and fixing of 4ways (4+12) Double door recess mounting ,vertical type ,415V ,TPN MCB distribution board of sheet steel ,dust protected ,duly powder painted, inclusive of 200A tinned copper bus bar, common neutral link, earth bar ,din bar for mounting MCBs (but without MCBs and incomer ) as required. (Note: vertical type MCB TPDB is normally used where 3 phase outlets are required.). Make: L & T/Anchor/ABB or similar | — | 11.00 | — | — | |
| — | — | — | 2,77,888 | ||
| Wiring for circuit /sub main wiring along with earth wire with the sizes (2 x 4 sq. mm + 1 x 4 sq. mm. earth wire ) of FRLS PVC insulated copper conductor ,single core cable in surface /recessed medium class PVC conduit as required. | — | 832.00 | — | — | |
| — | — | — | 10,137 | ||
| Supply and fixing of size/module, 3 module (100mm x 75mm) GI box along with modular base & cover plate for modular switches in recess etc. as required. Make: Northwest/GM/Carbtree or similar | — | 31.00 | — | — | |
| — | — | — | 4,836 | ||
| Supply and fixing of 15/16 A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Make: Northwest/GM/Carbtree or similar | — | 31.00 | — | — | |
| — | — | — | 6,107 | ||
| Supply and fixing of 6 pin 15/16 A socket outlet modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Make: Northwest/GM/Carbtree or similar | — | 31.00 | — | — | |
| — | — | — | 23,424 | ||
| Providing and fixing 25mm x 5mm G.I. strip on surface or in recess for connections Etc as required. | — | 96.00 | — | — | |
| — | — | — | 22,537 | ||
| Supply and fixing of suitable size of GI box with modular plate and cover in front on surface or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB "C" curve including connections ,painting etc. as required. | — | 31.00 | — | — | |
| — | — | — | 1,16,000 | ||
| Providing and fixing 400 AMP,4 pole MCCB and 50 KA breaking capacity with thermo magnetic release and terminal spreaders in existing cubicle panel board, ammeter with selector switch ,CT , including drilling holes/cutting in cubicle panel, making connections with aluminium bus bar, etc. as required. | — | 2.00 | — | — | |
| — | — | — | 2,78,461.38 | ||
| Supplying ,erection (with foundation/support structure) ,testing and commissioning of weather proof feeder pillar (LT panel board outdoor type floor mounted)14 SWG CRCA sheet with powder coated painting and IP-55 class of insulation having hinged door and locking arrangement rubber gasket ,extensible from both sides, with copper bus bar, suitable for 3 phase four wire 500 volts 50HZ , in all respect and conforming to latest relevant ISI specification ,earthing making etc., complete as required with incommer MCCB-250A 4-pole -01 no. and outgoing MCCB-100A ,4- Pole- 08nos. with multifunction energy meter. | — | 2.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
FinalTenderDocument.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].