Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹8.6 L+₹1.1 L (14.7%)Rejected-AOC | L2 | Rejected-AOC Other than Lowest Bidder | |
| 3 | L3₹9.1 L+₹1.6 L (21.1%)Rejected-AOC | L3 | Rejected-AOC Other than Lowest Bidder | |
| 4 | L4₹9.1 L+₹1.6 L (21.4%)Rejected-AOC | L4 | Rejected-AOC Other than Lowest Bidder | |
| 5 | L5₹9.7 L+₹2.2 L (28.8%)Rejected-AOC | L5 | Rejected-AOC Other than Lowest Bidder |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
15 Mar 2022, 6:00 pmClosed
GE (S) Jaipur
Garrison Engineer (South) Jaipur Military Engineer Services Kalyan Marg, Jaipur302006
REPAIR AND MAINT OF INTERNAL ELECTRIFICATION IN OTM ACCN OF SWC COMP SIG REGT AT BHANKROTA UNDER GE (S) JAIPUR
2022_MES_506466_1
GE (S)/J-67P of 2021-22 8712/E8
Open Tender
Civil Works
Item Rate
180 days
Jaipur
Class E category b (i)
9 documents required · 9 mandatory
₹500
GE (S) Jaipur
₹30,000
Yes
28 Mar 2022
8 Feb 2022
18 Mar 2022
8 Feb 2022
15 Mar 2022
3 Mar 2022
Amount
Taking down copper aluminium point wiring(light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc and making good disturbed surfaces of walls, floors, etc.
M&L for point wiring complete with 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor FRLS cable of 1100 V grade (ISI marked) PVC insulated and sheathed cable enclosed in and including pvc conduit with all accessories ISI marked,concealed to walls/ ceiling all as per IS including hard wood board and 3 mm thick phenolic laminated sheet top cover fixed or suitable cover for mounting fitting like switches, sockets, fan regulators of piano/ modulor type etc. including 1.5 sqmm single core PVC insulated but unsheathed copper earth continuty conductor to common earth and connected FRLS cable 1100 V grade (ISI marked) as continuous earth wire to earth dolly compiete all as sprcified and ditected for followings :-.
One light/fan/ bell point controlled by one, one way switch
One 3 pin 5 Amp socket outlet on the same board with other switches
One 3 pin 5 Amp socket outlet on independent board with other switches
All as per item No 2 above but Point wiring with 4 Sqmm copper cable for 3 pin 15 Amps socket outlet on independent board, including 4 Sqmm copper cable continuous earth wire and connecting to common earth dolly complete all as specified and directed.
M&L for point wiring complete with 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor FRLS cable of 1100 V grade (ISI marked) PVC insulated and sheathed cable enclosed in and including pvc Casing and Caping with all accessories ISI marked, all as per IS including hard wood board and 3 mm thick phenolic laminated sheet top cover fixed or suitable cover for mounting fitting like switches, sockets, fan regulators of piano/ modulor type also etc. including 1.5 sqmm single core PVC insulated but unsheathed copper earth continuty conductor to common earth and connected FRLS cable 1100 V grade (ISI marked) as continuous earth wire to earth dolly compiete all as sprcified and ditected for followings :-.
One light/fan/ bell point controlled by one, one way switch
One light point controlled by two, two way switches
One 3 pin 5 Amp socket outlet on the same board with other switches
One 3 pin 5 Amp socket outlet on independent board with other switches
All as per item No 4 above but Point wiring with 4 Sqmm copper cable pvc insulated unsheathed for 3/6 pin 15 Amps socket outlet on independent board, including 4 Sqmm copper cable pvc insulated unsheathed continuous earth wire and connecting to common earth dolly complete all as specified and directed.
S&F in repairs of switch, piano flush/ Bell push button type 230/250 volts ISI marked,complete all as speified and directed of following:-
Single pole , one way 5 Amp rating
Single pole, two way 5 Amp rating
Bell push, flush type 5 Amp rating
Single pole , one way 15/16 Amp rating
S&F switch, Modular/ Bell push type 230/250 volts ISI marked,complete all as speified and directed of following :-
One way 6 Amp rating switch
One way 16 Amp rating switch
Bell push, Modular type 6 Amp rating
Supply & fixing Socket outlet multipurpose use, flush mounting, 230/250 Volts grade (ISI marked) on top covers complete all as specified and directed by Engineer in charge of following :-
5 pin 6 Amp
6 pin 16 Amp
6 pin 5/6 Amp switch socket combination along with back mounting box complete all as specified and directed.
S & fixing Socket outlet of Modular type multipurpose use, 230/250 Volts grade (ISI marked) on top covers complete all as specified and directed by Engineer in charge of following:-
(2+3) Pin 6 Amp Socket
6/16 Amp Socket
S & F electric bell multi music type AC 230 volts single pole (ISI marked) for AC 230V, 50 Hz ding dong type complete all as specified and directed
S & F lamp holder angle type insulated body with back plate for batten/pendant fitting complete all as specified and directed
S&F Ceiling rose, 3 Phase/ PVC/ Polycarbonate isolated body (ISI marked) complete all as specified and directed by Engr-in-charge.
S&F in repairs of 3mm thick laminated sheet top cover (ISI marked) cut to suitable size and making arrangement for mounting switch, socket,regulator,etc. as all as specified and directed by Engr-in-charge.
S&F in repairs Energy efficient LED building lights of 30 Wattage with PDC Aluminium body and clear glass, LED lens for wide beam distribution with efficacy greater than 100 Lm/watt , 5700K CCT, pf more than .90 all as specified and directed by Engr-in-charge. (Note:- Bracket along with screw to fix on wall/surface duly painted by silver colour paint will be included in above quoted rate.) Make - Syska cat part No SSK-SLG-CF-30W or equivalent other make as appendix "B"
S&F in repairs Globe shaped post top lantern in frosted finish made up of Polycarbonate, long life aesthetically designed with systematic light distribution with IP 65 with 40 Watt LED Bulb and 5700 K lumen complete all as specified and directed. Make- Havells, CG, Bajaj, POLYCAB, Philips etc. (Note:- Cost of GI pipe of appropriate length and appropriate Dia. to fix post top lamp and cutting of wall/surface along with PCC 4:2:1 to fix GI pipe will be included in above quoted rate.) Make - Havells cat part No LHEVBGP7PN6L040 or equivalent other make as appendix "B"
S&F in repairs Bulk Head light environfriendly ultra modern energy saving surface mounted decorativeoval bulk head edge lit LED luminaire (10 watt) comprising of High brightness LED Lamp. Make - Havells cat part No LHEOAOP7UZ6W010 or equivalent other make as appendix "B"
S&F in repairs globe Light including LED Bulb and Base Holder made of Glass/Polycarbonate for decorative wall light fixture. Make - Havells cat part No LHDL06160099 or equivalent other make as appendix "B"
S&F in repairs LED lamp 4 Pin 18 watt suitable for 2x2 CFL light fitting.
S&F in repairs Aesthetically designed energy saving LED surface lighting fitting round in shape of 15 Wattage having white powder coated CRCA housing and PS diffuser of 6500K CCT as per old U/S existing fittings & all as specified and directed by Engr-in-charge. Make - Havells cat part No LHEAAGP7IA2W012 or equivalent other make as appendix "B"
Supply & fixing in repairs Energy saving environmental friendly, LED Batten Tube Light fittings 18/20/22 Watt ,1200mm(4 feet) TL, long life, impact proof,surface/wall mounting IP20,100 Lm per Watt, extruded Thermoplastic body with PC diffuser greater than 120 degree wide distribution available in 6500K CCT with high brightness LEDs complete with all accessories pre-wired twin core twisted flexible copper conductor cable with suitable size complete including dismantling of old existing unserviceable fluorescent/LED TL & all as specified and directed by Engr-in-charge. Make - Crompton greaves cat part No LDLSR20CDL or equivalent other make as appendix "B"
Supply & fixing in repairs Energy saving environmental friendly, LED Batten Tube Light fittings 10/12 Watt ,600mm(2 feet) TL, long life, impact proof,surface/wall mounting IP20,100 luminaire per Watt, extruded Thermoplastic body with PC diffuser greater than 120 degree wide distribution available in 6500K CCT with high brightness LEDs complete with all accessories pre-wired twin core twisted flexible copper conductor cable with suitable size complete including dismantling of old existing unserviceable fluorescent/LED TL & all as specified and directed by Engr-in-charge. Make - Crompton greaves cat part No LDLSR10CDL or equivalent other make as appendix "B"
Supply & fix in repairs False ceiling light LED slim panel of size 2ft x 2ft fitting of 40/42 Wattage having white powder coated extruded aluminium body with high quality LGP and PMMA diffuser suitable for Armstring/ Grid ceiling of 6000K CCT & all as specified and directed by Engr-in-charge.
M&L for taking down sub main wiring of copper with PVC/steel conduit complete all as specified and directed.
M & L for Sub main wiring with 02 runs of 6 Sqmm single core FRLS PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade (ISI marked) drawn through and including of 25mm dia PVC rigid conduit medium with conduit accessories and fixed to the surface of wall/ceiling as per ISI including 01 run of 6 Sqmm PVC insulated copper conductor earth continuity wire coplete all as specified and directed. Note : Two runs of copper conducter and one run of earth copper conducter and one run of PVC conduit shall be measured as one length.
M & L for Sub main wiring with 04 runs of 6 Sqmm single core FRLS PVC insulated unsheathed multi stranded copper conductor cable 1100 volts grade (ISI marked) drawn through and including of 32mm dia PVC rigid conduit medium with conduit accessories and fixed to the surface of wall/ceiling as per ISI including 02 runs of 6 Sqmm PVC insulated copper conductor earth continuity wire coplete all as specified and directed. Note :Four runs of copper conducter and Two run of earth copper conducter and one run of PVC conduit shall be measured as one length.
M&L for taking down unserviceable DBs /Sheet Metal Enclosures of any type disconnecting carefully and making good disturbed surfaces complete all as directed.
S & F sheet metal enclosure MCB DB 4 way SPN double door suitable for 240 V with degree protection IP 43- IK 09 with metal door and including 100 to 200 amps rated copper bus bar fixed/ flused on walls including cutting Knitch and making good disturbed surfaces complete all as specified and directed.Make - Legrand cat part No 507610 or equivalent other make as appendix "B"
S & F sheet metal enclosure MCB DB 8 way SPN double door suitable for 240 V with degree protection IP 43- IK 09 with metal door and including 100 to 200 amps rated copper bus bar fixed/ flused on walls including cutting Knitch and making good disturbed surfaces complete all as specified and directed. Make - Legrand cat part No 507611 or equivalent other make as appendix "B"
S & F sheet metal enclosure MCB DB 12 way SPN double door suitable for 240 V with degree protection IP 43- IK 09 with metal door and including 100 to 200 amps rated copper bus bar fixed/ flused on walls including cutting Knitch and making good disturbed surfaces complete all as specified and directed.Make - Legrand cat part No 507612 or equivalent other make as appendix "B"
S & F sheet metal enclosure MCB DB 4 way TPN double door suitable for 415 V(with out MCB) with degree protection IP 43- IK 09 with metal door and including copper bus bar fixed flused on walls including cutting Knitch and making good disturbed surfaces complete all as specified and directed. Make - Legrand cat part No 507670 or equivalent other make as appendix "B"
S & F in repair C-Curve MCB single pole (SP) 240 volt 06-32 amp,10 KA, ISI marked, for inductive load connected through cable lugs of switable size complete all as specified and directed.
S & F in repair MCB single pole neutral(SPN) 40 Amps,10 KA, ISI marked, for inductive load connected through cable lugs of suitable size complete all as specified and directed .
S & F in repair MCB Tripple pole neutral(TPN) 63 Amps,10 KA, ISI marked, for inductive load connected through cable lugs of suitable size complete all as specified and directed .
Supply and replace Unserviceable Plug and socket board with metal plug and socket (Metal clad box) (1 phase+neutral & earth) of 20 Amp rating DP of in accordance with IS 13032, IS 8623, IEC/BSEN 61439-3.
M&L for earthing complete as per electrical plate No. 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6.0 mm thick, buried directly vertically in ground in a pit depth not less than 2.5 metres below ground level with top edge of earth plate at a depth not less then 1.8 metre below normal ground level connected to and including galvanised iron or steel earth wire 4 mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing wire shall be protected by galvanised iron or steel pipe 15 mm bore medium grade and connected to continuous earth wire on pole / test point to main board. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover complete all as specified & directed as well as testing included taking down existing earthing complete. Note 1-: Following items deemed to be included in quoted rate (a) Earth Electrode (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre (c) M&L for connecting earth electrode, earthing lead and excavation earth work in any type of soil, PCC work etc as specified (d) Adequate quantity of charcol dust and common salt as directed (e) All labour involved including testing of earth net work (f) Excavation and earth work or drilling hole for electrode (g) P.C.C pit and C.I cover (h) Funnel and watering pipe, wire mesh and copper lugs etc. as specified (j) G.I protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. (k) connected lead from test point to main switch or switch board or equipment to be earthed. Note 2-: In case, after completion if the desired earth resistance is not obtained on testing then, the earthing will be redone at no extra cost.
S & F in repair modular switch board of 6 module suitable for switches and sockets with suitable base plate and cover plate complete with proper nut bolt and suitable for existing modular socket and switches complete all as specified and directed by engr- in- charge.
Ceiling Fan Taking down the defective ceiling fan of any size(600/1200/1400 mm) sweep any make after disconnecting electrically & mechanically incl transportation, dismantling, examine & carry out the repairs as required and brought back to site after Servicing/repairing the ceiling fan by thoroughly cleaning the bearing/Bush,checking serviceability of downroad, shaft, stator, rotor & applying the lubricant / grease including one coat of super enameled varnish over the winding to improve the insulation value,re-assembling, testing and refixing back to the site in all respect .Note - Note “ Spares required for Replacement shall be measured and paid separately as supply only in respective items".
Supply only Ball-bearings/bush for ceiling fan of (1200/1400 mm) sweep.
Supply only Ceiling fan downrod of size 12 inch to 24 inch or as per site requirement of material mild steel including clamp hook, rubber nut & bolt requiired for its proper mounting with ceiling.(Note- The mild steel downrod to be painted as per old U/S existing color with synthetic enamel paint)
Re-winding the burnt/short circuited winding for ceiling fan of (1200/1400 mm) sweep with same guage super enameled copper wire to maintain speed at load.
Supply only in repairs of u/s capacitor from 2.15 to 3.15 mfd capacity for (600/1200/1400) mm sweep complete all as specified and directed.
S&F in repairs stepped type electronic fan regulator 240 V 50 HZ,100 Watts flush type (ISI marked) on the existing phenolic laminated sheet etc complete all as specified and directed.
Taking down the repairable exhaust fan of any size(300 / 450 mm) any make, single phase, 230 volts, 50 hz, AC after disconnecting electrically and mechanically incl transportation, dismantling, examine & carry out the repairs as required and brought back to site after Servicing/repairing the exhaust fan by thoroughly cleaning the bearing/Bush, shaft, stator, rotor & applying the lubricant / grease including one coat of super enameled varnish over the winding to improve the insulation value,re-assembling, testing and refixing back to the site in all respect .Note - Note “ Spares required for Replacement shall be measured and paid separately as supply only in respective items"
Supply only Ball-bearings for exhaust fan of (300 / 450 mm).
Re-winding the burnt/shourt circuited winding for exhaust fan of (300 / 450 mm) with same cauge supper enameled copper wire to maintain speed at load.
Supply only exhaust fan motor for (300/450) mm sweep of desired specifications (ISI Marked) to maintain current speed,air flow at load.
Desert cooler Taking down of Desert cooler for Repairs / Servicing (3000/4000) CFM air flow capacity single phase 230 Volts of any make after disconnecting electric/water connection drain out water and carry out minor repair work such as repairing of internal worn out wires, and for replacement of unserviceable parts such as Motor, Fan blade, Lead wire including testing and painting with one coat of sythetic enamel paint complete all as specified and directed by Engr-in-charge. (Painting with one coat enamel paint will be included in unit rate quoted for above item.) Note “ Spares required for Replacement shall be measured and paid separately as supply only in respective items"
Re-winding the burnt/shourt circuited winding for Desert cooler (3000/4000) CFM air flow capacity single phase 230 Volts of any make with same gauge super enameled copper wire to maintain speed at load.
Supply only Fan motor for Desert cooler (3000/4000) CFM air flow capacity single phase 230 Volts all as per existing one & all as directed by Engr-in-charge.
Supply only Fan Blade set PVC/iron body with nut, Bolt, washer for (3000/4000) CFM Desert Cooler of any make all as per existing one complete all as specified and directed by Engr-in-charge
Supply only Flexible Core PVC insulated with stranded copper conductor 1.5 Sqmm 3 core 600/1100 V ISI Marked all as directed.
Supply only Submersible Vertical pump ISI marked with suitable head for Desert coolers (3000/4000) CFM air flow capacity single phase 230 Volts & all as specified and directed by Engr-in-charge.
Supply only Switch Piano 5 Amp single pole 230 volt 50 Hz.
S & F in reapirs Plug top for desert cooler 3 pin 5 Amps, 230 Volt AC, ISI marked complete all as specified and directed.
S&F in repair iron frame clamp as per existing one with required no. of nut & bolt to hold fan as well as motor of Desert cooler all as specified and directed by Engr-in-charge
Supply and fix in repair Side Panels(set of 3) made of MS Sheet (24 gauge) (galvanised) for (3000/4000) CFM Desert Cooler.
Supply & fix wooden shelving pad for Desert cooler each set of three for 3000/4000 CFM & all as directed by Engr-in-charge.
Supply & fix in repairs PVC flexible pipe (from vertical pump to distributer and distributer to side shutter approx 2 mtr) 15mm dia for Desert cooler including 3 way distributor junction tee set complete all as specified and directed by Engr-in-charge.
Water Coolers Dismantling/taking down of water cooler (40/80) Ltr for repair such as fan motor,compressor and other minor rep & replacement of defective parts/ spares as in item no. 51.01 to 51.06 from any place any capacity, transported to workshop & back after repair and testing complete all as specified and directed (i) Spare Parts required for replacement shall be measured separately under respective supply only items given here-in-after for item no. 51.01 to 51.06 (ii) Recharging Gas will be measured and paid separately.
Supply only Compressor ( Sealed unit ) suitable for 40/80 Ltr. Water Cooler
Supply only Fan Motor 1/10 H.P Single phase,230V for water cooler.
Supply only Thermostate for water cooler ISI marked,complete all as specified and directed.
Supply only Starting capacitor 60 to 80 MFD 230 volts, 50 Hz.
Supply only over load relay suitable for Water cooler 40/80 ltr.
Supply only Fan Motor blade as per sample all as directed.
Air Conditioner Servicing of 1.5TR/2TR capacity split type AC unit by cleaning with air pressure,tighting of bolts and nuts, arresting all leakages with necessary brazing/welding ensuring leak proof cleaning of condensor tubes ,checking of serviceability of fan motor,compressor,relay ,capacitors,PCB Coli,control circuit remote,sensor indicator electric circuits etc. ,incl labour for replacing of unserviceable parts except compressor and charging of refrigerant gas complete all as specified and as directed by Engr-in-charge. Notes : ( i) Replacement of compressor unit shall be measured and paid separately ( ii) Spare Parts required for replacement shall be measured separately under respective supply only items given here-in-after for item no. 52.01 & 55 to 59. ( iii) Recharging Gas will be measured and paid separately.
Supply only Blower Motor, single phase 230 Volts 1500 RPM, suitable for split type AC 1.5-2 ton.
M&L for disconnecting and removing U/S sealed compressor unit from 1.5 TR capacity split type AC including supply and connecting with original sealed compressor unit all as specified and as directed by Engr-in-charge.
All as per above item No. 53.00 but for AC 2 TR capacity split type
Supply only Running capacitor 45 to 50 MFD 230 volts, 50 Hz for window/split AC.
Supply only Starting capacitor 100 to 120 MFD 230 volts, 50 Hz for window/split AC.
Supply only Plastic filter as per existing makes for Window/split type AC 1.5-2 ton capacity.
Supply only Over load protector relay suitable Window/split type AC 1.5-2 ton capacity.
Supply only PCB coil suitable for Window/split type AC 1.5/2.0 ton capacity complete all as directed.
M&L for gas Freon-22(R22)/R 410a/ R32 all including filling of gas as directed by Engr-In-Charge..
M&L for gas R-134a all including filling of gas as directed and checked by Engr-In-charge.
Replacement of U/S remote control with existing make for Window/split type AC 1.5-2 ton capacity.
Refrigerator Checking of unservisable/ faulty Refrigerator (180 to 320) Ltr capacity installed in various locations for proper repair and testing of Fan motor, thermostatic switch, over load protector relay, box type relay, evaporator coil assembly etc. complete all as specified and directed by Engr-in-charge. ( i) Replacement of compressor unit shall be measured and paid separately ( ii) Spare Parts required for replacement shall be measured separately under respective items as supply only given here-in-after (63.01 & 66 to 69) ( iii) Recharging Gas will be measured and paid separately.
Supply only fan motor with existing make for refrigerator of capacity (180 to 320) Ltr all as specified and as directed by Engineer-in-Charge.
Supply/replacement of compressor (sealed unit) with relay suitable for refrigerator of capacity (180 to 320) Ltr all as specified and as directed by Engineer-in-Charge.
Supply and fix toughened glass for vegetable box/ Bottle self/ Vegetable box for 180 to 320 Ltr capacity refrigerator complete all as specified and directed.
Supply only in replacement of Thermostatic switch with knob suitable for Refrigerator.
Supply only in replacement of over load protector relay suitable for refrigerator of capacity ranging from 180 to 320 Ltr all as directed by Engr-in-charge.
Supply only in replacement of Box type relay suitable for refrigerator (180 to 320)Ltr capacity Engr-in-charge.
Supply only in replacement of Evaporator coil assembly of existing make for refrigerator (180 to 320) Ltr capacity Engr-in-charge.
Supply & fix in repairs of Magnetic door gasket for refrigerator (180 to 320) Ltr capacity Engr-in-charge.
Supply & fix in repairs of freezer door for refrigerator (180 to 320) Ltr capacity Engr-in-charge.
VOLTAGE STABILISER Re-winding the burnt/short circuited winding for Voltage stabilizer of 2/4/5KVA rating capacity single phase 230 Volts of any make with same gauge super enameled copper wire.
M/S JALANDRA CONSTRUCTIONS
M/s Prakash Enterprises
M/S TRADE LINKERS
M/S Anil Enterprises
VARDHMAN SALES CORPORATION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .