Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹55.9 LAccepted-AOC ROOM NO 220 2ND FLOOR DEVGIRI BUILDING NO 65 B LALLU BHAI COMPOUND MANKHURD MUMBAI 400043 | MUMBAI SUBURBAN | MAHARASHTRA | 400043 | L1 | Accepted-AOC Admitted | |
| 2 | L2₹59.2 L+₹1.6 L (2.78%)Rejected-AOC 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400708 | THANE | MAHARASHTRA | 400708 | L2 | Rejected-AOC Not Admitted | |
| 3 | L3₹65.6 L+₹8.0 L (13.8%)Rejected-AOC FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L3 | Rejected-AOC Not Admitted | |
| 4 | L4₹65.7 L+₹8.0 L (14.0%)Rejected-AOC | L4 | Rejected-AOC Not Admitted | |
| 5 | L5₹68.5 L+₹10.9 L (18.8%)Rejected-AOC MHN 284 DRIVER HILL VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L5 | Rejected-AOC Not Admitted |
Tender Value
₹72 L
EMD Value
₹1.5 L
Closing Date
4 Jul 2020, 6:00 pmClosed
CWE (SUBS) MUMBAI
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
SPECIAL REPAIRS TO OFFICERS MARRIED ACCOMMODATION NS-130 (CUAVERY) AT MO(MB) GHATKOPAR UNDER GE (NW) BHANDUP
2020_MES_326667_1
8460/E8
Open Tender
Civil Works
Item Rate
365 days
MO (MB) GHATKOPAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (NW) BHANDUP
₹1.5 L
Yes
17 Jul 2020
7 Apr 2020
6 Jul 2020
7 Apr 2020
4 Jul 2020
25 Jun 2020
Amount
Demolition of concrete in ground floors (un re-inforced) and paving n.exc. 15 cm thickness (below or above ground level) as in plinth protection and removal of rubbish/ demolished materials out of MD land complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises etc out side MD land complete all as specified and directed.
Dismantling stone slabs and tiles of any description or thickness in floors, kitchen platform and similar work laid, bedded and pointed in cement mortar and removal of rubbish/ demolished materials out of MD land complete all as specified and directed
Demolition of brick work or stone boulder masonry,built in cement mortar or cement lime mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work and precast concrete articles and removal of rubbish/ demolished materials out of MD land complete all as specified and directed.
Dismantling cast iron of any description etc complete all as specified and directed
Taking down cement or cement lime plaster of any description on brick or stone wall and ceiling surface including raking out joints, hacking for key, scrubbing down with water etc and disposing off the rubbish outside MD land complete all as specified and directed.
Taking down chowkat or frame with shutter (without taking off shutter from the frames) and including grills/ guard bars not exceeding 1.5 Sqm each including cutting walls/ jambs for takingout holdfast etc and making good all disturbed surfaces with cement morter complete as directed
Taking down chowkat or frame with shutter (without taking off shutter from the frames) and including grills/ guard bars exceeding 1.5 Sqm but not exceeding 4.0 Sqm each including cutting walls/ jambs for takingout holdfast etc and making good all disturbed surfaces with cement morter complete as directed.
Taking down wooden shutters of any description, not exceeding 1.0 Sqm each complete all as specified and directed.
Taking down wooden shutters of any description, exceeding 1.0 Sqm and n exc 2.0 sqm each complete all as specified and directed.
Resecuring or easing and adjusting, without taking down shutters of any description exc 1.0 sqm each but not exceeding 2.0 Sqm each complete all as specified and directed.
M&L for PCC 1:2:4 Type B1 using 20 mm graded aggregate as in hold fast, coping ,cills ,steps, seismic and other similar bands, plinth course, string course, parapets, railing, bed plates, kerbs and the like including weathering,slightly rounded or chamfered angles and throating as directed.
M&L for brick work with sub-class 'B' bricks, straight, or curved on plan to any radius as in half brick thick wall in CM 1:4 complete all as specified and directed.
M&L for brick work with sub class B bricks straight or curved on plan exceeding 6 m mean radius built in CM 1:6 complete all as specifed and directed
S&F aluminium section in doors/windows/ventilators ,any type, powder coated in approved colour (Thickness of powder coating not less than 50 micron), aluminium section (medium weight of series 'B') or section as directed by Engineer-in-Charge, cut to size, jointed together with cadmium plated steel screws including rubber beading or gasket for aluminium sections for fixing glass/XPM jali and all necessary fittings complete, screws, plugs for fixing screws, etc all as specified and directed (Make : JINDAL/HINDALCO) Notes : (i) Weight of aluminium sections shall only be measured. (ii) The supply only rate of bakelite sheet glass pane,wire mesh and rubber beading or gasket will be measured separately.
S&F only 4mm thick figured glass/pin headed type ordinary quality fixed in aluminium ventilator n exc 0.50 Sqm each pane all as specified & as directed by EIC.
Supply only stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of aperture 1.40 mm , fixed in aluminium windows complete all as specified and directed.
Supply only for 6mm thick bakelite sheet prelaminated both side with decorative choice laminations with aluminium frame cuboard shutter work complete all as specified and directed.
S&F aluminum anodised grill DG- 202 ( 10 mm x 7.5mm ) of Deco grill or equivalent fixed with 'F' section size not less than 20.60 x 15.20 x 1.5mm thick of approved make all as specified and directed. Note : (i) Make shall be of M/s Decogrille of M/s Associated Groups or equivalent as approved by the GE. (ii) Minimum thickness of anodizing shall be 15 microns.
S&F second class Hard Wood as in plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints etc all as specified
S & F second class hardwood, glazed and skelton shutter, 35 mm thick, open rebated and prepared to receive glass, gauze etc, divided into square with plain, chamfered or rounded mitered and rebated sash bars, edges of framing plane, chamfered or rounded, fitted with cut and mitered bead for securing glass, gauze etc, size of member of shutters as specified in SSR Part -I, section 8, class 8.24(a) (Door shutter), supplied and fitted to chowkats all as specified and directed.
S& F second class HW 40mm thick,plain, framed, panelled shutters (any numbers of panels), with pannels of timber flat on both sides (feather edged) or of veneered particle board medium density, wood particle board with commercial face neneers;fixed to chowkats complete all as specified & directed.
S&F Solid PVC door frame (Chowkhat) of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube etc complete all as specified and directed.
S&F for Factory made solid PVC Moulded door shutter, 28 to 30 mm thick, with 2,4 or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing with wood free EPS complete all as specified and as directed.
S&F aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40mm and fixed tinned tacks or aluminium wire staples,and fixing of teak wooden beeding complete all as specified and as directed by the Engineer in charge.
M&L for 19mm thick block boards, grade - I quality, exterior grade, decorative type with decorative face veneer on both sides with external teak wood lipping, 6mm thick alround fixed with screws to timber frame work etc, complete all as specified and directed..
S&F for 20mm dia curtain rods mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified and directed
S&F 100 mm stainless steel butt hinges,complete all as specified and directed
S&F 150mm length aluminium anodised barrel tower bolt of extruded section complete all as specified and directed
S&F 150 mm length extruded aluminium alloy handles,fabricated type, anodised complete all as specified and directed
S&F alluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast alluminium alloy and fixed of length of bolt 250 mm complete all as specified and directed.
S&F bands, steps, supports or stays for rain water, hooks (stay) heavy for large gates, hook and pintle hinges clamps, hold fasts wall ties, hooks for hanging james and similar small articles Fe-410-0 or Fe-310-0 complete all as specifed and directed.
M&L for 75 mm thick cement concrete 1:3:6 type C-1, (20 mm graded aggregate) as in plinth protection finishes and fair without using extra cement including forming 12 mm thick construction joint filled with sealing compound Grade 'A' etc complete all as specified and directed.
M&L for Non-skid ceramic tiles (Coloured) 7 to 8 mm thick rectangular area of each tiles exc 0.06 Sqm n exc 0.11 Sqm in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:4 laying floor finished complete all as specified and directed.
S&F light coloured vitrified ceramic tiles 10 mm thick (square / rectangular) polished , area of each tile not exc 0.36 Sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 20mm thick in cement mortar 1:6 for laying floor finishes, all as specified by Engr-in-Charge
M & L for coloured vitrified tiles of size 600 x 600 mm, 10 mm thick, superior quality, fixed with required thickness as per manufacturers adhesive of Ferrouscrete (FERRO-1122) / Fevimate XL- Pidilite / Gold star of Bal Endura or equivalent, as in flooring, over backing coat, complete including levelling the wall complete all as specified and as directed for :- ( Note : Skirting shall be flush with the walls)
M&L for vertified ceramic tiles 10 mm (light shade of square/ rectangular) polished, area of each tiles not exc 0.36 Sqm in walls skirting etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including over 10mm thick rendering in CM 1:4 on fair faces of brick/concrete surfaces as in backing coat for tiles.complete all as specified and directed.
M&L for glazed ceramic coloured tiles 450 x 350 mmx7mm thick in vertical surfaces such as skirting/dado and risers to steps and including over 10mm thick rendering in CM 1:4 on fair faces of brick/concrete surfaces as in backing coat for tiles. etc, all as specified and directed.
S&F machine cut and machine polished, green marble, 18-20 mm thick on horizontal or vertical surface,as in window cills and jambs bedded, jointed and pointed with neat grey cement slurry and pointed with coloured or white cement with pigment to match over and including rendering coat of 10 mm thick in CM 1:4 all as specified and directed.
M&L for 18-20mm thick granite(of any type) work table rubbed and polished as in steps, jambs, pillars, windows-cill, cooking platform , jambs and the like in cement mortar (1:4) including pointing in white / coloured cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting , moulding etc over and including 10mm thick rendering / screed in CM 1:4 on fair faces of brick/concrete surfaces complete all as specified and directed.
M&L for 20 to 25mm thick machine cut and machine polished cudappa stone slab for kitchen plateform jointed and set in CM 1:3 and fi fixed including rounding to edge of stone slabs one side edge etc complete all as specified and as directed
M & L for rendering 10 mm thick in CM 1:6 on brick walls or concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 5 mm thick in CM 1:3 on concrete surfaces as in ceiling and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces in two coats (10 + 5 mm), both coat mixed with integral water proofing compound ISI Marked @ 2% by the weight of cement and finishing the surface even and fair complete all as specified and directed Note - WPC shall be measured and paid separately
Supply only integral water proofing compound.
M&L for Preparation of New Plastered surfaces of wall and applying two coats of Dr fixit rain coat over( of Shade/colour as directed ) one coat of Dr fixit prime seal primer all as per manufacturer instruction including necessary scaffoldings etc complete all as specified and directed by Engr- in charge
M&L for Preparation of old Plastered surfaces of wall and applying two coats of Dr fixit rain coat over( of Shade/colour as directed) one coat of Dr fixit prime seal primer all as per manufacturer instruction, including complete removal of existing surfaces including washing / rubbing down with water of wall including necessary scaffoldings etc complete all as specified and directed.
M & L for preparation of new plastered surfaces of walls and applying Two coat of oil bound distemper including application of wall care putty for smooth finish.etc with roller over one coat of alkali resistant primer including chalk whiting complete all as specified and directed.
M & L for preparation of old plastered surfaces of walls and applying Two coat of oil bound distemper including application of wall care putty for smooth finish.etc with roller over one coat of alkali resistant primer including chalk whiting complete all as specified and directed.
M&L for preparation of old decorated surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and thereafter applying with roller Two coat of oil bound distemper etc complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed
M&L for preparation of old decorated surfaces of ceiling brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and thereafter applying Two coat of white wash complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified and directed
M&L for preparation of old decorated surfaces of wall brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and there after applying Two coat of white wash complete all as specified and directed.
M&L for preparing new or previously untreated wood and wood based surface of any description, over 10cm in width or girth, not other wise described and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
M&L for for preparation of old wooden surfaces of any description or not other wise described over 10 cm width or girth and applying two coats of synthetic enamel paint all as specified and directed.
M&L for preparation of old decorated steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
Taking down eaves gutters and rain water pipes (any size or any pattern) including all fittings heads, shoes, bends swan necks etc including cleaning or refixing removal to stores.
S&F 160mm bore PVC rain water pipe single socketed (ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps 8mm dia with two nuts wall nails etc complete all as specifed and directed.
S&F Cast iron work grade FG 150, unmachined in bracket, gully traps, grating, railing,frames,manhole covers,fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles all as specified and directed.
S&F 75mm bore PVC (SWR) pipe single socketed(ISI Marked) any length with rubber ring joints, complete fittings etc fixed to wall fixed with MS clamps8mm dia with two nuts wall nails etc complete all as specifed and directed.
S&F 110mm bore PVC (SWR) pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps8mm dia with two nuts wall nails etc complete all as specifed and directed.
S&F 75mm bore PVC (SWR) bends any radius dimnishing pieces or tapers with access doors etc, complete all as specified and as directed.
S&F 110mm bore PVC (SWR) bends any radius dimnishing pieces or tapers with access doors etc, complete all as specified and as directed.
S&F 75mm bore PVC (SWR) branch piece, single (single Y ) equal or unequal with access doors etc, complete all as specified and as directed.
S&F 110mm bore PVC (SWR) branch piece, single (single Y ) equal or unequal with access doors etc, complete all as specified and as directed.
S&F 75mm bore PVC (SWR) junction single (single T ) equal or unequal with access doors etc, complete all as specified and as directed.
S&F PVC floor trap 75mm dia outlet, with CP grating including jointing to waste pipe, fixed in cement concrete type B1 (1:2:4) & including removing old trap complete all as specified and as directed.
S&F CI floor trap 100mm dia outlet, with CP grating including jointing to waste pipe, fixed in cement concrete type B1 (1:2:4) & including removing old trap complete all as specified and as directed.
S&F GI tube heavy grade of 40 mm bore with all fittings and fixed complete to walls and ceilings or laid in floors or sunken portion etc complete all as specified and directed
S&Fin repair wash down water closet (pedestal pattern) white and including plastic water closet seat cover as per reqd colour with flat bottom and cover and mild steel chromium plated or aluminium hinging device (excluding flushing cistern ) etc complete all as specified and directed..
S&F in repair Toilet paper holder of Prayag polymers pvt ltd complete all as specified and directed.
S&F in repair Health faucet with 1.5 mtr tube & hook complete all as specified and directed.
S&F in repair CP corner glass with brass bracket screws etc complete all as specified and directed.
S&F in repairs vitreous china squatting pan, white, orissa pattern pan of size 580 mm x 440 mm of standard quality with integral foot rests,and including 'P' trap or 'S' Trap complete including connection to trap and to flushing pipe, anti syphonic pipe etc., complete all as specifiedand directed.
S&F in repairs wash hand basin, vitreous china white of size 550x 400mm excluding taps, waste chain and plug and porcelain stopper but including brackets,32mm waste fitting and waste pipe of 32 mm bore, brass, chromium plated for glazed ware wash basin and 15mm dia pillar taps chromium plated fancy type etc complete all as specified and directed.
Supply and fix in repair 10 ltre, PVC, valveless, syphonic action type, flushing cistern, low level/ high level including inlet, ball valve, float and handle including brackets with and including PVC flush pipe 32 mm bore, connecting to WC etc, complete all as specified and directed.
S&F CP concealed stop cock 15mm bore fancy type chromium plated (Cat Part No OPP 15083 KPM of Jaquar or equivalent Make as approved) with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs CP angle cock 15 mm bore fancy type chromium plated (Cat Part No OPP 15053 PM of Jaquar or equivalent Make as approved) with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs CP long nose bib tap 15 mm bore fancy type (Cat Part No OPP 15037 PM of Jaquar or equivalent Make as approved) with crutch or butterfly handle, screwed for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repair 15mm size PVC connection with PTMT nuts 450mm length.complete all as specified and directed.
S/F in repairs brass Chromium plated wall mixer (Cat Part No CON - 273 KN OPR of Jaquar or equivalent Make as approved) for mixing hot and cold water screwed down for iron pipe and fixed 15mm bore fancy type.
S&F in repairs chromium plated shower roses 125mm size (Cat Part No 276016) with or without swivel joint including fixing to steel pipe or union etc. make: jaquar, marc, kohler
S&F in repair CP Tubular towel rail (Cat Part No CAN - 1111 SM of Jaquar or equivalent Make as approved) with hook 20 mm dia 600mm long between flanges of fixed with and including chromium plated brass screws and wooden/plastic screws. complete all as specified and directed.
S&F Soap dish (Cat Part No CAN - 1131 N of Jaquar or equivalent Make as approved), Stainless steel fancy type approx size 160x160x90mm complete all as specified and directed.
S&F stainless steel kitchen plate rack Cat No P-348 etc Make:Prayag polymers Pvt Ltd or equivalent make as approved complete all as specified and directed.
S&F stainles steel sink with drainage board , one mm thick for kitchen or laboratory, with plug, waste pipe, washers including CI cantilever bracket, connecting union etc., overall size 915 x 460 mm with bowl size 410 mm x 330 mm x 160 mm complete all as specified and directed.
S&F in repair PVC cabinet mirror of minimum size 450X313 mm complete all as specified and directed.
S&F in repair low density polyethelene pipes (LDPE) 32mm of pressure rating 6 Kg/cm2 fixed to walls or laid in floors etc.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 15mm complete all as specified and directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 25mm complete all as specified and directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 40mm complete all as specified and directed.
Cutting and grooving of wall for fixing of GI pipe lines and after fixing of GI pipe line and making good of all cutting surfaces
S&F 3-layer PP-R (polypropylene random copolymer) pipes 20 mm SDR 7.4 & SDR 11 UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc, complete all as specified and directed.
Ditto all as per item No 96 above but 25 mm bore etc, complete all as specified and directed.
Ditto all as per item No 96 above but 40 mm bore etc, complete all as specified and directed.
S&F in repair for gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipe & fixed of size 40 mm bore complete all as specified and directed.
S&F in repair for gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipe & fixed of size 25 mm bore complete all as specified and directed.
M&L for special treatment for sunken portion of WCs/ Bath & toilet executed in following stages:-
Stage 1 :- Demolition of WC including lime concrete and cement concrete coba etc and preparing the surfaces of existing sunken portion of WCs or bath etc with wire brush to remove all loose dirt, oil grease etc including removing debris outside MD land etc Complete.
Stage 2:- Providing 10mm thick plaster in CM 1:3 mixed with integral water proofing chemical of Dr. Fixit Pidicrete URP or plaster seal of STP Ltd in the proportion/quantity all as per Manufacture's instructions.
Stage 3:- Apply Dr Fixit Primeseal primer or Equivalent of STP Ltd (and allow to dry for 8 hours) all as per Manufacture's instructions.
Stage 4:- Apply two coats of water proofing elastomeric coating system of Dr Fixit Raincoats with DFT 100 Micron or shalicry 215 of STP (The surface after painting one coats shall be allowed to dry of 6 hours before next coats) all as per Manufacturer's instructions.
Stage 5:- Rendering 10mm thick in CM 1:3 mixed with Integral water proofing chemical Dr Fixit Pidicrete URP or plaster seal of STP Ltd all as per Manufacture's instructions.
Stage 6. All CI joints shall filled with mixture of cement fine sand and plaster seal of STP Ltd or Dr Fixit pidicrete URP all as per Manufacture's instruction.
Stage 7:- Making holes in wall and fixing 600mm long 40mm dia medium grade GI spout for draining the surplus water if any
Stage 8:- Carry out ponding test for 48 hours to ensure water tightness of repaired sunken portion.water tightness of repaired sunken portion and filling of sunken portion for cement concrete Type E2 1:5:10 using 40 mm graded aggregate as in lean concrete complete all as specified and directed. Note :- (a) Only plan area shall be measured and accorded for payment under this item. (b) Depth of sunken portion of WC's/Baths shall be upto 35cm, which is to be taken into account while quoting the rate against this item. (c) Rate quoted by Contractor shall be deemed to be included for all the horizontal and vertical treated surfaces of sunken portions of WC & Bath.
Chipping, removing carefully loose/damaged concrete including plastering (total thickness exceeding 40mm but not exceeding 60mm ) from surfaces of RCC members, in any location by low impact Hammer/Breakar without damaging the structure & cleaning the surfaces with wire brush etc and disposal of debris out side MOD land complete all as specified and directed. Note : 1) Hard concrete shall not be removed by force
M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hour between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.)
M&L for carry out application of ‘Bi-polar migratory corrosion inhibitor' [Make : M/s. Krishna Conchem (EPCO KP-100) / BASF (MasterProtect®8000Cl)] on RCC surfaces, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.)
M&L for Anticorrosive Treatment to Reinforcement using IPNET-RB of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces complete all as specified and directed . Note :- Mode of measurement: superficial area of concrete will be measured.
M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar / concrete to ensure bond between old concrete & new concrete/ new mortar by brush application, complete all as specified and directed.
M&L for providing Polymer Bonding Agent of Make M/s. Krishna Conchem (MONOBOND) OR Fosroc (NITOBOND-SBR) OR equivalent brand of Dr. Fixit,as approved by the GE followed by flexible polymer based putty ( 1cement: 1.2 finesand :20% polymer by weight of cement : water as required ) on cracks after cutting the cracks to a 'V' shaped groove upto 10 mm wide and 10 mm deep in structural RCC members , finished with spatula etc. complete all as specified and directed.
M&L for building up the profile of structural members using polymer modified mortar from M/s. Krishna Conchem (Molith PMM) OR Polymer mortar HB of Dr Fixit, while the bonding agent is still tacking upto 20mm thickness, including levelling, profiling etc, complete all as specified and directed.
M&L for building up the profile of structural members using polymer modified mortar from M/s Krishna Conchem (Molith PMM) OR Polymer mortar HB of Dr. Fixit, exceeding 20mm thick and not exceeding 40mm thick in two layers, each of equal thickness including leveling, profiling etc, complete all as specified and directed.
Taking down carefully copper/aluminum point wiring of any type such as Concealed/surface/batten/casing and capping (light fan, socket or power) complete including fitting such as switches, ceiling roses, pendants, lamp/bracket holders, sketch/bulk head fittings, regulators, sockets, board outlets etc and making good the disturbed surfaces of walls, floor, ceiling etc for rewiring and repairs etc.
M&L for point wiring for light/fan controlled by one switch with 1.5 Sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and including PVC concealed conduit having thickness not less than 2 mm with all fittings including modular steel sunk box having thickness not less than 2 mm including 1.5 Sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching with the existing colour and all as specified .Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)(Make of copper wire:Le Grand/Havells/Polycab and PVC conduit Make: Precision,Plaza)
All as per srl item No 123 above but for call bell point.
All as per srl item No 123 above but for 5 pin 5 amps socket outlet on the same board with other switch all as specified.
All as per srl item No 123 above but for 5 pin 5 amps socket outlet indenpendent board of light point all as specified.
M&L for point wiring with 2.5 Sqmm single core PVC insulated unsheathed multistranded copper conductor FRLSH with and in and including PVC concealed conduit having thickness not less than 2 mm with all fittings including modular sunk box having thickness not less than 2 mm including 2.5 Sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly.and including cutting chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching existing colour and all as specified . Note: colour coding is to be maintained .(Ph-Red, N-Black, Half-Yellow, Earth- Green)(Make of copper wire:Legrand/standard/Havells and PVC conduit Make: Precision,Plaza)
M&L for point wiring with 4 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and in and including PVC concealed conduit having thickness not less than 2 mm with all fittings including modular sunk box having thickness not less than 2 mm including 4 Sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly.and including cutting chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching existing colour and all as specified . Note: colour coding is to be maintained .(Ph-Red, N-Black, Half-Yellow, Earth- Green)(Make of copper wire:Legrand/standard/Havells and PVC conduit Make: Precision,Plaza)
M&L for submain wiring in and including PVC conduit having thickness 2 mm, 25 mm dia with two run of PVC insulated, sheathed multistranded copper conductor of 10 sqmm(FRLS) and one run of PVC insulated, sheathed multistranded copper conductor 10 sqmm (green in color) for earth continuity conductor and connected to common earth dolly with thimble etc, cutting chiseling for concealed piping and making good the disturbed surface area white wash/colour wash to matching with existing colour complete all as specified and directed.. (Note: Two run of 10 sqmm plus one run 10 sqmm of earth wire will be measured as 1RM) including dismantling of existing unserviceable submain wiring all as specified and directed.Make:Legrand/Havells/polycab Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)
M&L for ceiling rose three terminals AC 240 volts 50Hz complete all as specified of make: Havells/Legrand/Cona
Supply and fixing bell ding dong AC 240 volt Ac 50Hz complete all as specified and directed.
Supply and fixing modular ceiling fan regulator 120 watt two module AC 240 volt complete all as specified and directed.
M&L for switch modular one way 6/5 amps one module complete all as specified.of make: legrand/ Havells/Elvira(Indo Asian)
M&L for switch modular one way 15/20 amps one module complete all as specified.of make: legrand/ Havells/Elvira(Indo Asian)
M&L for socket modular 6Amp 2/3 pin combined 2 module complete all as specified and directed.
M&L for socket modular 16/20 Amp 2/3 pin combined 2 module complete all as specified and directed.
M&L modular bell push 6Amp one module complete all as specified and directed.
Supply and fix in repairs sheet metal enclosure powder painted for MCB DB SPN 8 way double door with din rail and 200 Amp bus bar complete all as specified and directed. Make: Legrand/Schneider/Siemens
Supply and fix in repairs MCB SP 240 Volts 5 to 32 Amps breaking capacity 10 KA rating complete all as specified and directed.Legrand/Schneider/Siemens
Supply and fixing modular metal flush box 1/2 module complete all as specified and directed.
Supply and fixing modular metal flush box 3 module complete all as specified and directed.
Supply and fixing modular metal flush box 4 module complete all as specified and directed.
Supply and fixing modular metal flush box 6 module complete all as specified and directed.
Supply and fixing modular metal flush box 8 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 1/2 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 3 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 4 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 6 module complete all as specified and directed.
Supply and fixing modular white cover plate with frame 8 module complete all as specified and directed.
Material and Labour for tube light fitting LED 18 watt with decorative end caps made out of CRCA sheet powder coated complete with housing t with aluminium heat sink on back of leds ,power factor >0.9,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting and shall be fitted on new plastic square/round block complete all as per specified and directed. Make: philips / Havells /CG, Techno commercially equivalent in Luccar etc . Note:1.Contractor shall produce LM79 & LM80 test reports from OEM owned NABL accredited laboratory.Contractor shall also produce certificates for power factor and surge protection from the company at no extra cost.
Material and Labour for tube light fitting LED 10 watt with decorative end caps made out of CRCA sheet powder coated complete with housing and with aluminium heat sink on back of leds, power factor >0.9,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting and shall be fitted on new plastic square/round block complete all as per specified and directed. Make: philips / Havells /CG, Techno commercially equivalent in Luccar etc Note:1.Contractor shall produce LM79 & LM 80 test reports from OEM owned NABL accredited laboratory. Contractor shall also produce certificates for power factor and surge protection from the company at no extra cost .
Supply and fix in repairs highly efficient high power 40/45 W LED street light fitting with pressure die cast aluminium housing reflector and enclosed with heat resistant toughened glass IP66 protection AC 240 Volts 50 HZ refractive lens with suitable electronic drive PF > 0.9 complete including taking exiting unserviceable street light fitting. Make: Philips/Havells/CG
Taking down existing ceiling fans and re-fixing the same ceiling fan and exhaust fan any sweep including provisioning of cable from ceiling rose to ceiling fan and spray painting of ceiling fan/Exhaust fan with two coats of synthetic enamel paint complete all as specified and directed.
Supply, install, test and commissioning of LT panel board indoor type totally enclosed with front opening made out of 2 mm thick CRCA sheet, factory made powder coated painted as approved colour, aluminum bus bar suitable for 3 phase 4 wire LT, AC, 50Hz, 433 volts, 300 Amps capacity RYBN insulated with sleeved insulation complete with multifunctional meter LED type by showing Amps, volts, frequency etc along with suitable size of CT on outgoing, indicating lamp RYB, complete internal wiring with suitable size of PVC insulated copper conductor cable, including cable glands and lugs for incoming and out going cables as per required sizes, including 75mm channels fixed on existing floor with suitable nut, bolts, washers etc all as specified and directed for suitable to in and including accomodate the following items and all as specified and directed by dismantling exisiting unserviceable LT panel complete. [a] MCCB 4 pole 200 Amps with breaking capacity 36 KA adjustable type with extended terminals - 01 Nos [Incoming] [b] MCCB 4 pole 63 Amps with breaking capacity 25 KA adjustable type with extended terminals - 01 No [c] MCCB 4 pole 32 Amps with breaking capacity 16 KA adjustable type with extended terminals - 03 Nos [d] MCB SPN 63 A - 10 Nos [e] MCB SPN 32 A - 11 Nos [f] Space for provision of 21 Nos Single phase meters including internal connections between meter and MCB SPN Note: The rate quoted deemed to include the cost of dismantling the existing serviceable energy meters and fixing in new panel board.
Supply and fixing modular motor starter 25 Amp 2 module for AC complete all as specified and directed.Make:Legrand model No: 673466/Schneider/Seimens
M & L for earthing complete with Copper earth plate electrode 60 cm x 60 cm x 6 cm thick buried directly in ground vertically at a depth not less than 2.25 m below normal ground level with top level of earth plate at depth not less than 1.5 m below normal ground level surrounded form all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using Copper strip 32 mm x 6 mm by means of bolts, nuts, check nuts and washers of Stainless Steel upto test point and protected by GI pipe light grade 40 mm bore up to 7.5 Mtr connected to a main switch board or main control board and GI pipe light grade 20 mm bore for watering and including funnel, wire mesh, 80 mm thick pre-cast RCC 1:2:4, type B-1 cover reinforced with hard drawn steel wire fabric weighing not less than 4 Kg/Sqm in lieu of CI cover, PCC 1:3:6 type C2 pit / chamber including all necessary excavation and earth work, disposal of surplus soil to a distance not exceeding 50 m all as specified and as shown in Electrical Plate No3 of MES Schedule Part – I of 2009.
Supply and fix in repairs MCB SPN 240 Volts 16 to 40 Amps breaking capacity 10 KA rating complete all as specified and directed.Legrand/Schneider/Siemens
MUKESH CONSTRUCTION CO
R J ENTERPRISES
Maaz Construction
Super Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .