Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.6 LAccepted-AOC MD 1 236 SECTOR D1 LDA COLONY KANPUR ROAD LUCKNOW U P PIN 226012 | LUCKNOW | UTTAR PRADESH | 226012 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹41.6 L+₹8.5 L (25.8%)Rejected-Finance 73 ASHOTOSH NAGAR NEAR KUNDAN GENERAL STORE OPP SARAD TIMBER P O MANAS NAGAR KRISHNA NAGAR LUCKNOW 226023 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226023 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹35.2 L+₹2.2 L (6.64%)Rejected-Finance | L3 | Rejected-Finance Other than lowest |
Tender Value
₹42.3 L
EMD Value
₹84,600
Closing Date
12 Jan 2021, 6:00 pmClosed
GE West Lucknow
11, Sardar Patel Marg, Lucknow Cantt
ADDN ALTN TO BLDG NO P 11 AT 8 ATAL ROAD COMMA ADDN ALTN TO EXISTING SEWAGE DISPOSAL SYSTEM OF BLOCK 9 10 AND 11 SPL REPAIR TO BDY WALL WITH FENCING AT 44 ASC PROVN OF CATTLE FENCING OF BLDG NO. 27BY1 AT RLB MARG PROVN OF HARDSTANDING AT BLDG NO 10 A
2020_MES_404061_1
GE/W/LKO/64 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
Lucknow Cantt
Class D
Cat a i
8 documents required · 8 mandatory
₹500
GE West Lucknow
₹84,600
Yes
8 Feb 2021
16 Dec 2020
14 Jan 2021
16 Dec 2020
12 Jan 2021
31 Dec 2020
16 Dec 2020 - 29 Dec 2020
Amount
Demolition of brick work or stone/ boulder masonary, built in cement mortar or cement lime mortar including all quions, arches, pillars, etc. but excluding ashlar facings, dressed stone work and precast concrete articles etc. complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc. 15 cm thickness (below or above ground level) complete all as specified and directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section embedede in concrete, brick work, masonary etc., including taking out embedded portion and making good disturbed gound complete all as specified and directed.
Excavating in post holes (or similar holes) each n.exc. 0.5 cum getting out, returning, filling in, and ramming earth or broken rubble mixed with earth around in layer n.exc. 25 cm in soft/ loose soil complete all as specified and directed.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified and directed.
Excavating in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in soft/ loose soil complete all as specified and directed.
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layers not exc. 25cm in soft/ loose soil complete all as specified and directed.
Removing surplus excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
M&L for hardcore of broken stone or boulders of gauge not exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
M&L for brick work with old size fly ash bricks of class designation 75, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4 complete all as specified and directed.
M&L Cement Concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other bands, plinth courses, string cources, lacing cources, parapets and railing upto 60cm in hight, copings, kneelers, apex stones, bed plates, water troughs, hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and directed.
M&L Mild Steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed.
S&F 5mm thick Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet incluseive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed.
M&L for broken glass coping on top of walls in cement mortar 1:3 complete all as specified and directed.
S&F false ceiling with 4mm thick 'E' Board (Make: Everest) of size 600x600mm, white, prelaminated sheet embossed reinforced designer ceiling board tiles of approved texture and powder coated, hot dipped GI imposed grid frame work complete all as specified and directed including all necessary drilling, cutting to fix electrical items as under with the following:- (a) 24x24x0.45mm thick powder coated GI angle plugged @ 600mm c/c along perimeter of wall. (b) 24x32x0.33mm thick powder coated GI tee as main and cross runners suspended with 4mm dia GI wire suspenders with adjustable clamps and dash free fastners with rawl plug and screws plugging in RCC slab etc. placed @ 600mm c/c from perimeter of wall. (c) Fixing of 4mm thick 'E' board tiles and finished complete with one coat of oil emulsion distemper on ceiling. NOTE: The complete ceiling work shall be executed as per manufacturer's instructions and as directed.
M&L in repair structural steel work with rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates etc and similar articles conforming to Fe-410W (Gde E-250) quality-A complete all as specified and directed.
M&L cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
M&L mild steel framed work such as posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting and/or welding etc. and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F in repair galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossings with and provn of galvanised mild steel wire, staples or steel pins etc. complete all as specified and directed. NOTE: Each line wire to be measured.
Fixing only chain link fencing including line wires, any mesh size and type to any type of standards rails, straining bolts, etc. including provn of galvanised mild steel binding wire of 0.9mm dia annealed complete all as specified and directed.
Supply only mild steel galvanised chain link fencing of any type or size complete all as specified and directed. NOTE: Weight constant of fencing shall be fixed by BOO.
Supply only mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, 5 to 10mm dia of neck, length of bolts exc. 5cm but not exc 10cm long complete all as specified and directed. NOTE: Weight constant shall be fixed by BOO.
Taking down cement or cement lime plaster any description from walls/ceiling etc including racking out joints, hacking for key & scrubbing down with water all as specified and directed.
M&L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces of wall and finished surface even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 with integral water proofing compound @ 3% by weight of cement on fair faces of brick work or concrete surface of wall and finished surface even and smooth without using extra cement complete all as specified and directed. NOTE: WPC shall be measured and paid seperately under respective item.
Supply only integral waterproofing compound complete all as specified and directed.
M&L for two coats of oil bound distemper over one coat of primer and 1mm thick layer of wall care putty on newly plastered surfaces of wall including preparation of surfaces complete all as specified and directed.
Complete removal of existing treatment of wall and M&L for two coats of oil bound distemper on previously treated plastered surfaces of wall over one coat of primer and 1mm thick layer of wall care putty including preparation of surfaces complete all as specified and directed.
M&L for two coats of cement base paint over one coat of primer on newly plastered surfaces of wall including preparation of surfaces complete all as specified and directed.
M&L for preparation of new or previously untreated surfaces of steel or iron of any description over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of new or previously untreated surfaces of steel or iron of any description n.exc. 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of old or previously treated surfaces of wood or wood based materials of any description over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old or previously treated surfaces of steel or iron of any description over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed.
M&L for 50mm thick cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in floor, finished surface even and smooth without using extra cement and forming 12mm wide expansion joints to the full depth, and filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade 'A' complete all as specified and directed.
M&L for 75mm thick cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate as in plinth protection, laid in panels, finished surface even and smooth without using extra cement and forming 12mm wide expansion joints to the full depth, and filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade 'A' complete all as specified and directed.
M&L for precast cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves etc and similar works set in cement mortar 1:4 complete all as specified and directed.
M&L 100mm thick cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in sub bases of floors and pavings etc. finished even and fair without using extra cement complete all as specified and directed.
M&L 75mm thick cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in sub bases of floors and pavings etc. finished even and fair without using extra cement complete all as specified and directed.
M&L for 60mm thick M-35 grade rubber moulded factory made machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 with grey cement and pigment as approved laid over and including 25mm thick sand cushion and joints filled with sand complete all as specified and directed.
S&F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls with PVC clamp complete all as specified and directed.
S&F in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls with PVC clamp complete all as specified and directed.
S&F PVC (SWR) bends of any radius, suitable for 110mm bore PVC pipes, fixed and jointed with solvent complete all as specified and directed.
S&F PVC (SWR) bends of any radius, suitable for 75mm bore PVC pipes, fixed and jointed with solvent complete all as specified and directed.
S&F PVC (SWR) branch piece, single (single Y), equal or unequal suitable for 110mm bore PVC pipes, fixed and jointed with solvent complete all as specified and directed.
S&F PVC (SWR) branch piece, single (single Y), equal or unequal suitable for 75mm bore PVC pipes, fixed and jointed with solvent complete all as specified and directed.
S&F PVC (SWR) vent cowls suitable for 110mm bore pipes complete all as specified and directed.
S&F PVC (SWR) vent cowls suitable for 75mm bore pipes complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in surface channels and drains complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed.
Add or deduct to above item for each 25mm girth or part thereof over and under 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed.
Demolition and breaking up 150mm internal dia of drain pipes (Salt glazed ware, AC or Reinforced concrete), set in cement mortar complete all as specified and directed.
Demolition and breaking up 200mm internal dia of drain pipes (Salt glazed ware, AC or Reinforced concrete), set in cement mortar complete all as specified and directed.
M&L for 150mm bore reinforced concrete drain pipes, class NP3 complete with collars, laid and jointed in cement mortar 1:1 as in drains and similar works complete all as specified and directed. NOTE: Excavation and earthwoth with cutting existing manhole and making good shall be measured and paid seperately under respective item.
M&L for 200mm bore reinforced concrete drain pipes, class NP3 complete with collars, laid and jointed in cement mortar 1:1 as in drains and similar works complete all as specified and directed. NOTE: Excavation and earthwoth with cutting existing manhole and making good shall be measured and paid seperately under respective item.
M&L for cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in concrete foundation bed to 150mm bore drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in concrete foundation bed to 200mm bore drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
M&L cutting into existing manholes for connecting new drains, making good to 150mm bore pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required complete all as specified and directed.
M&L cutting into existing manholes for connecting new drains, making good to 200mm bore pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required complete all as specified and directed.
M&L for construction of Septic Tank suitable for 150 users with RCC M-25 Design Mix (using 20 mm graded stone aggregate) as in bases, baffle walls, beams, roof slab, cover slab, covers etc., brick work with old size fly ash bricks in CM 1:4 and manhole cover made out of 6mm thick MS steel sheet and frame of angle iron 50x50x6mm including all required earthwork in soft/loose soil, cement concrete etc. complete all as shown on CELZ drawing No. TD/217 sheet 1/2 & 2/2 amended upto date complete all as specified and directed.
M&L construction of Soakage Well of size 3.60m dia, 6.00m effective depth and 7.50m overall depth with fly ash bricks and RCC M-25 Design Mix (using 20 mm graded stone aggregate) as in cover slab etc. including all required earthwork in soft/loose soil, filling of brick bats and cement concrete etc. complete all as shown on CELZ drawing No. TD/576 sheet 1/2 & 2/2 dated 16.06.1989 complete all as specified and directed.
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors etc. to match the existing complete all as specified and directed. NOTE: Credit for this items shall be made as per conditions separately.
M&L for point wiring complete for one light point or one fan point controlled by one, one way 5 Amp switch with PVC (FRLS) insulated unsheathed multistranded copper conductor of size 1.50 sqmm nominal cross sectional area single core drawn in and including 20mm dia 'medium grade' PVC concealed conduits ISI marked and fittings, including pressed steel concealed terminal switch boxes not less than 1.6mm thick of reqd size factory made duly painted inside and outside with one coat red oxide primer, 3mm thick plastic laminated bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC(FRLS) insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories complete all as specified and directed.
All as per item no 64 above but for one 5 pin 5 Amp socket outlet point on an independent board.
All as per item no 64 above but for one 5 pin 5 Amp socket outlet point on the same board with other switch.
All as per item No. 64 above but for One bell/ buzzer point on an independent board controlled by one bell push
All as per item no 64 above but for one 6 pin 15/16 amps socket outlet point on an independent board with cables of size 2.50sqmm and green colour earth cable of size 2.50sqmm.
S&F Switch piano, flush type, single pole, one way 5/6 Amp 230 Volts complete all as specified and directed.
S&F Switch piano, flush type, single pole, one way 15/16 Amp 230 Volts complete all as specified and directed.
S&F socket outlet, flush type, single pole, multipurpose 2 in 1, 5 pin 5/6 Amp, 230 volts complete all as specified and directed.
S&F socket outlet, flush type, single pole, multipurpose 2 in 1, 5 pin 15/16 Amp, 230 volts complete all as specified and directed.
S&F ceiling rose, 3 terminal, PVC/ Polycarbonate, insulated body, surface bakelite sheet 63.50mm dia complete all as specified and directed.
S&F Lamp holder PVC/ Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F bell push, flush type, single pole, one way 5/6 Amp, 230 volt flush type complete all as specified and directed.
S&F in repair call bell, ding dong type, AC single pole, 230 volt complete all as specified and directed.
S&F sheet metal enclosure for MCB DB double door type, tripple pole and neutral 4 way, 415Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed.
S&F sheet metal enclosure for MCB DB double door type, single pole and neutral 12 way, 240Volts with 100/125 Amps rated bus bar of suitable size plate and common neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way complete all as specified and directed.
S&F MCB, single pole 6 to 32 Amp, 240 volts, 10 KA breaking capacity, 'C' curve complete all as specified and directed.
S&F MCB, single pole & neutral 40 to 63 Amp, 240 volts, 10 KA breaking capacity, 'C' curve complete all as specified and directed.
S&F MCB, tripple pole & neutral 63 Amp, 415 volts, 10 KA breaking capacity, 'C' curve complete all as specified and directed.
S&F in repair sheet metal enclosures, single pole with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed.
S&F sheet metal enclosures, single pole with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed.
S&F in repair ceiling fan regulator, electronic, rotary step up socket type, 230 volts suitable for 1200/1400 mm sweep ceiling fan including necessary connection complete all as specified and directed.
S&F ceiling fan regulator, electronic, rotary step up socket type, 230 volts suitable for 1200/1400 mm sweep ceiling fan including necessary connection complete all as specified and directed.
Taking down old copper/ aluminium sub main wiring or service connection complete all as specified and directed
S&F sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 4sqmm nominal cross sectional area and one run of 4sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including 25mm dia 'medium grade' PVC concealed conduits (ISI marked) and fittings complete all as specified and directed. NOTE:- One unit length shall measured as two run of main wire and one run of conduit & earth wire.
S&F sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 2.5sqmm nominal cross sectional area and one run of 2.5sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including 25mm dia 'medium grade' PVC concealed conduits (ISI marked) and fittings complete all as specified and directed. NOTE:- One unit length shall measured as two run of main wire and one run of conduit & earth wire.
S&F wall mounted 18/20 W LED integrated tube light fitting of size 1200mm long batten with aluminium housing and decorative end cap and one no 18/20 W LED 6000 K, 230V, with integrated electronic driver complete with all required fittings and fixtures arrangement including and provn of connection from ceiling rose to luminaries with 3 core flexible copper wire complete all as specified and directed. Make: Havells cat no. LUMILINEPLUSBS20WLED865SPCSS or Surya Visco cat no. 18W LED SLEBT 20 IL or C&S cat no. LTT4F20WLED/W/ Philips Cat part No. 021LED22S6500/400 PSU GR/SI.
S&F wall/surface mounting luminaries (Mirror Light) integrated LED Batten (2 feet) 9/10/12 W, 6000 K, 230V with extruded aluminium housing & integrated electronic driver complete including necessary electrical connection with PVC three core copper flexible wire & all necessary fixing arrangements complete all as per specified and directed. Make: HAVELLS cat Part No. Lumiline plus BS 10WLED865SPCSS/ Surya Visco cat Part No. SLE BT 10/C&S cat Part No.LTTB2F10WLED/W /Philips Cat Part No. BN021 LED 12 S 6500/4000 PSU GR/SI
S&F security light fitting of 25 W LED 6000 K, with high power LED source (more than 100 lumens per watt), PDC housing, IP65 with 4KV inbuilt surge protection driver and one no. 25W LED tube, with all accessories, prewired with and fixed to bldg/pole including GI bracket 1.20m long bent to shape, made out of 40mm dia GI light grade pipe with nuts, bolts and washers and provn of connection from ceiling rose to luminaries with suitable size copper wire complete all as specified and directed. Make: Havells Endura Pearl cat no. ENDURAPEARLSL25WLED757SASYTOPCMP or Surya Lexon Cat Part No. SLE UL 25W IP 66(LXN)/ C&S (Indus E Series) with cat Part No.LTESS25WLED/LS/ Philips Cat Part No. BRP042LED25CWR1S1PSU GR
S&F in repair super bright LED (2X2) light fitting, 36 W, 6000 K recess mounting with high efficent LED source with 02 nos LED Light with all accessories, prewired and fixed in ceiling complete all as specified and directed. Make: Surya Celesta cat no. SLE DS 36 22R or C&S cat no. LTCRP36WLED2x2 of CYGNUS-C series or Philips TROFFER cat no. RC370B LED36S-6500/ 4000G5L60W60.
S&F super bright LED (2X2) light fitting, 36 W, 6000 K recess mounting with high efficent LED source with 02 nos LED Light with all accessories, prewired and fixed in ceiling complete all as specified and directed. Make: Surya Celesta cat no. SLE DS 36 22R or C&S cat no. LTCRP36WLED2x2 of CYGNUS-C series or Philips TROFFER cat no. RC370B LED36S-6500/ 4000G5L60W60.
S&F in repairs of surface type square LED 12W downlighter of size160 mm x 160 mm as required all as per specified and directed. Make: Havells cat part No. EDGEPROSQDLR12WLED840S/ Surya (Stellar) Cat part No. SLE DLS 12W XX Stellar SQ/C&S (CORONA) LTCRSUR12HPLEDSQ/W / Philips Cat part No. SM 260 & SM261
S&F surface type round LED 12W downlighter of dia 160 mm as required all as per specified and directed. Make: Havells cat part No. EDGEPRORDDLR12WLED840S/ Surya (Stellar) cat part No SLE DLS 12W XX Stellar RD/ C&S (CORONA) LTCRSUR12HPLEDRND/W / Philips Cat part No. SM 250 & SM251
S&F wall light with Decorative wall light fixture made up of Polycarbonate/aluminium/brass/steel, (Spiral B-22 base), with 01 No. 9 W LED Bulb, 230 V, 6000K, complete incl all required electrical connections arrangements complete all as specified and as directed. Make Havells code : CITY 1 LHDL02160099 or equivalent in Bajaj/Philips(Grace) Cat part No. 919215850005/ Mepro Cat Part No. AL-135 (Note: Rates incl 01X 9 W LED Bulb with each fitting)
S&F 1100V grade heavy duty XLPE armoured cable, PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection of size 10sqmm, 2 core cable complete all as specified and directed.
suniltraders
M/S Chandra Mohan and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .