| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC | ₹1.7 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹1.9 Cr+₹14.7 L (8.60%)Rejected-Finance 32 06 PEST HOUSE NARONA CHAURAHA MALL ROAD POST BOX NO 49 KANPUR 208001 UP | KANPUR | KANPUR | UP | 208001 | ₹1.9 Cr+₹14.7 L (8.60%) | L2 | Rejected-Finance Being not lowest |
| 3 | L3₹1.9 Cr+₹21.1 L (12.3%)Rejected-Finance SHIV BHAWAN MAGADH COLONY ROAD NO 03 SHERGHATI ROAD GAYA BIHAR PIN 823001 | GAYA | GAYA | BIHAR | 823001 | ₹1.9 Cr+₹21.1 L (12.3%) | L3 | Rejected-Finance Being not lowest |
Tender Value
₹2.1 Cr
EMD Value
₹2.9 L
Closing Date
10 Feb 2024, 6:00 pmClosed
CWE
CWE AF BAMRAULI
ADDITIONAL ALTERATION IMPROVEMENT TO SMQs and OMQs AT AIRFORCE STATION BIHTA
2023_MES_634037_1
87343/E8
Open Tender
Civil Works
Item Rate
273 days
BIHTA PATNA BIHAR
Class B Category a i and other criteria as per NIT and Tender Doc
8 documents required · 8 mandatory
₹2,000
GE (AF) BIHTA
₹2.9 L
Yes
20 Mar 2024
22 Dec 2023
17 Feb 2024
22 Dec 2023
10 Feb 2024
27 Jan 2024
22 Dec 2023 - 5 Jan 2024
Amount
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for including removal of unserviceable material outside of MOD land complete all as specified and as directed.
Demolition of Brickwork or stone/ boulder masonry, built in lime mortar/cement mortar including all quoins, arches, pillars, etc omplete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) including removal of unserviceable material outside of MOD land complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for including removal of unserviceable material outside of MOD land complete all as specified and as directed.
Demolition of bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc (each layer) laid, bedded and pointed in any mortar including removal of debris/muds outside of MOD land complete all as specified and as directed.
Demolition of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) and finally cleaning the surface with wire brush to remove old treatment to lay PCC padding including removal of unserviceable material outside MOD land complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Dismantling of stone slab and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and as directed.
Dismantling water tanks and removing to store (capacity exc 250 & n exc 500 ltrs) complete all as specified and as directed.
Dismantling existing cast iron soil vent pipe of 100 mm internal dia, fixed to wall or laid in trenches incl all fitting & accessories complete all as specified and as directed.
Dismantling existing cast iron soil vent pipe of 75 mm internal dia, fixed to wall or laid in trenches incl all fitting & accessories.
Taking down or up 15 mm bore galvanised iron tubing and connection including cleaning for refixing or removal complete all as specified and as directed.
Taking down or up 20 mm bore galvanised iron tubing and connection including cleaning for refixing or removal complete all as specified and as directed.
Taking down chowkats or frame with shutter (without taking out shutter from the frame) not exceeding 1.50 sqm each and removal from site all as specified and directed.
Taking down chowkats or frame with shutter (without taking out shutter from the frame) exceeding 1.50 sqm and n exc 4.00 sqm each and removal from site complete all as specified and as directed.
Taking down of shutters of any description exc 1.00 Sqm but n. exc 2 Sqm each complete all as specified and as directed.
Taking down rain water pipes (any size or pattern) ,including all fittings complete all as specified and as directed.
Taking down cement plaster on brick or stone walls & chajja including raking out joint, hacking for key,scrubbing downwith water etc complete all as specified and as directed..
M&L 100 mm thick Soling (or sub base) with broken boulders or quarried stone, inter stices filled, surface formed and rolled and consolidated to required gradient complete all as specified and as directed.
M&L Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in 1:6 cement mortar complete all as specified and as directed.
M & L for PCC 1:3:6 type C-0 using 12.5mm aggregate crushed stone aggregate as in filling back side of pressed steel door/window frames complete all as specified and as directed.
M&L for providing cement concrete type E-2, 1:5:10 (40 mm graded aggregate) as in foundations, filling and mass concrete, filling of sunken portion etc complete all as specified and as directed.
M&L for providing cement concrete type B-1, 1:2:4 (20 mm graded aggregate) as in roof padding, roof kerbs (rounded or chamfered on edge) etc complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and as directed.
M&L 75 mm thick cement concrete type D-2, 1:4:8 (using 40 mm graded aggregate) as in floor complete all as specified and as directed.
M&L for 25 mm thick cement concrete type B-0, 1:2:4 (12.5 mm graded aggregate) as on floor complete all as specified and as directed.
M&L 75mm thick cement concrete type D-2, 1:4:8 (using 40 mm graded aggregate) as in sub base of floor and hardstanding of PAVER BLOCK ccomplete all as specified and as directed.
M&L Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directed..
M & L for PCC 1:2:4 type B1 using 20mm graded stone aggregates as in benching, coping etc slightly rounded or champhered complete all as specified and as directed.
M&L RCC (Nominal mix) type B1, 1:2:4 (20mm graded aggregate) for Slabs supported on walls, beams and col-umns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for Applying treatment to sunken portion including demolition of existing concrete, WC , Por S trap and removing unserviceable material outside MoD land as described below:- (a) Preparation of RCC surface of sunken slab (Floor) by brushing and cleaning thoroughly with water. (b) Application of two coats of poly urethene based chemical treatment as per manufacturer's instruction of DR fixit/FOSROC/CICO/STP as approved. (c) 15mm thick rendering in cement mortar 1:4 over chemical coating including finishing the surface even and smooth without using extra cement Note:- Continuity with cementitious water treatment beyond sunken portion in toilet shall be maintained.
M&L for Applying treatment after taking down cement plaster including tiles etc and removing the unserviceable material out side MoD land as described below:- (a) Preperation of RCC surface of sunken slab (side) by brushing and cleaning thoroughly with water. (b) Application of two coats of poly urethene based chemical treatment as per manufacturer's instruction of DR fixit/FOSROC/CICO/STP as approved (c) 15mm thick rendering in cement mortar 1:4 over chemical coating including finishing the surface even and smooth without using extra cement Note:- Continuity with cementitious water treatment beyond sunken portion in toilet shall be maintained.
Supply only integral water proofing compound complete all as specified and as directed.
M&L for appling bitumen primer @ 0.30 Litre/Sqm acomplete all as specified and as directed.
M&L for applyng tack coat of hot blown bitumen 85/25 grade @1.2 Kg/ Sqm including preperation of surfaces complete all as specified and as directed.
M&L applying polymeric water proofing membrane consisting of 90-100mm micron thick central core of HMHDPE film and min weight 3kg/Sqm shall be laid with 100mm side/end lap over hot bitumen on prepared surfaces as per manufacturer's instruction and under supervision of technical representative of manufacturer complete all as specified and as directed.
M&L for 8 to 9 mm thick roof cool tile of size 300mm x 300mm to reduce room temperature, slip resistance, white in colour having properties like water absorption max 3..3%, breaking strength 1000N , moisture expansion max 3% scratch hardness 4 min, thermal stock resistance 10 cycles, min impact resistance 0.55, tiles laid over and including of 15 mm thick screed be or bedding layer in cement mortar 1:6 and joints grouted flush in cement mortar 1:3 complete all as specified and as directed. Make:-ISI Marked or Conforming to relevant IS as approved by GE.
M&L for 8 to 9 mm thick Vitrified tiles of approved quality (square/ rectangular) 'light shade' , area of each tile not exceeding 0.36 Sqm, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and as directed.
M&L for 7 to 8 mm thick Non-skid coloured ceramic tiles of approved quality (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and as directed.
M&L for 6 to 7 mm thick glazed ceramic coloured tiles of approved quality of size 450mm x 300 mm as in vertical surfaces such as skirting dados etc set jointed in neat cement slurry and pointed in coloured cement to match with the tiles over and including 10 mm thick rendering in cement mortar 1:4 on brick work or concrete surface complete all as specified and as directed.
M&L for 18-20 mm thick Granite (of any type) work table rubbed and polished as in steps, jambs, pillars, window-cills, cooking platforms (including making hole for gas pipe and like over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and similar situations complete all as specified and as directed.
M&L for 18-20 mm thick mirror polished machine cut kota stone slab (pre-polished) laid and jointed with grey cement slurry mixed with pigments to match the shade of stone as in treads, landings of stair case over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 complete all as specified and as directed.
M&L for 16-18 mm thick mirror polished machine cut kota stone slab (pre- polished) laid and jointed with grey cement slurry mixed with pigments to match the shade of stone as in skirting and risers of stair case over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and as directed.
M&L for 5 mm thick rendering in cement mortar 1:3 on concrete surfaces as in ceiling , surfaces finished even and fair complete all as specifed and as directed.
M&L for 10 mm thick rendering in cement mortar 1:6 on brick work or concrete surfaces on vertical surfaces , surfaces finished even and fair complete all as specified and as directed.
M&L for 10 mm thick rendering in cement mortor 1:4 on brick work or concrete surfaces mixed with water proofing compound as per manufacturer's instruction, surface finished even and smooth without using extra cement complete all as specifed and as directed. Note :- Water proofing compound shall be measured and paid seperately under respective item.
M&L for 15 mm thick rendering in cement mortar 1:4 on brick work or concrete surface as in vertical surfaces ,surface finished even and smooth without using extra cement mixed with water proofing compound as per manufacturer's instruction complete all as specified and as directed. Note:-Water proofing compound shall be measured and paid seperately under respective item.
M&L applying three coats of white wash on wall including preperation of plastered surfaces complete all as specified and as directed.
M&L for applying three coats of white wash on ceiling including preperation of plastered surfaces of wall complete all as specified and as directed.
M&L for applying two coat of white wash on wall including preparation of old decorated plastered surfaces complete all as specified and as directed.
M&L for applying two coats of white wash on ceiling including preparation of old decorated surfaces of ceiling complete all as specified and as directed.
M&L for applying two coats oil bound distemper including one coat of alkali resistant primer over and including 1 mm thck wall care putty on plastered surface of wall complete all as specified and as directed
M&L for applying two coats oil bound distemper over one coat of alkali resistant primer over and including 1 mm thick wall care putty including complete removal of existing treatment of wall complete all as specified and as directed.
M&L for applying two coat of exterior emusion weather coat paint over and including one coat of exterior primer including preparation of newly plastered surfaces of walls complete all as specified and as directed.
M&L for applying two coat of exterior emusion weather coat paint over and including one coat of exterior primer including complete removing of existing treatment of wall surfaces by scrapping with mechanical sander (having mechanical vacuum mechanism) to make surface clean, free from dust, loose paint etc complete all as specified and as directed.
S&F 15 mm bore galvanised iron tube medium grade with necessary fitting as required , fixed to walls & ceilings or laid in floors complete all as specifed and as directed.
S&F 20 mm bore galvanised iron tube medium grade with necessary fitting as required , fixed to walls & ceilings or laid in floors complete all as specifed and as directed.
S&F 20 mm bore galvanised iron tube medium grade with necessary fitting as required , laid in trenches complete all as specifed and as directed.
S&F 500 Litres capacity rotational moulded polyethylene water storage tanks with all fittings (cylindrical vertical with closed top) hoilsted and fixed in position all as specified in SSR Part-I 2009 complete all as specified and as directed..
S&F 20 mm bore brass ball valves, high pressure with polythene float and flynut screwed for iron pipe or brass ferrule and fixed. (minimum weight 210 gram) complete all as specified and as directed.
S&Fin repair 20 mm bore Gun-metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
S&F of Nipple suitable for HDPE water tank for 20 mm bore pipe (Minimum weight 45 gms) complete all as specified and as directed.
S&F in repair 15 mm bore chromium plated fency type stop cock/angular cock, cast copper allay, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipes complete all as specified and as directed.
S&F in repair 15 mm bore chromium plated concealed type stop valves cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipes complete all as specified and as directed.
S&F in repairs 125 mm long chromium plated shower rose with or without swivel joints, fixed to steel pipe or union complete all as specified and as directed.
S&F in repairs 15 mm bore chromium plated bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixedcomplete all as specified and as directed.
S&F in repairs PVC connection 15 mm size with PTMT nuts of length 450 mm of approved quality complete all as specified and as directed.
S&F Soap Dish brass chromium plated decorative type approximate size 160mmx160mmx90mm complete all as specified and as directed..
S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed.
S&F brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges fixed with wall complete all as specified and as directed.
S&F in repairs Vitreous China squatting pan of Orrissa pattern of approved make of size 580 mm X 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including trap set in and including concrete and connection to flushing pipe incl lime concrete bedding and connection to antisyphonage pipe etc including making good to floorcomplete all as specified and as directed.
S&F in repair 10 litre capacity PVC low level cistern inclusive of brackets and PVC bend long type and connection to flush pipe of any size and pattern with inlet ball valve float and handle complete all as specified and as directed.
S&F in repairs of Vitreous china wash hand basin, white, flat back of size 630mm x 450 mm including waste coupling, cast iron brackets, PVC waste pipe and connection 32 mm bore complete all as specified and as directed.
S&F in repairs of 15mm bore pillar taps, fancy type, cast copper alloy with capstan heads, Decorative type chromium plated screwed down, high pressure screwed for iron pipe complete all as specifiedand as directed.
S & F in repairs of stainless steel sink with draining board, made out of 1.00 mm thick sheet for kitchen or laboratory with plug, washers, waste pipe, cast iron cantilever brackets, connecting union of overall size 915mm x 460mm with bowl size 410mm x 330mm x 160mm.complete all as specifiedand as directed.
S&F stainless steel plate rack of approved pattern (wall mounted) as in kitchen of size 30 inch x 36 inch x 8 inch complete all as specified and as directed. Make :- A-One or equivalent as approved.
S&F 100 mm dia cast iron soil waste and vent pipes sand cast in any length with or without ears with cement joints laid in trenches or in floorcomplete all as specified and as directed.
S&F 75 mm dia cast iron soil waste and vent pipes sand cast in any length with or without ears with cement joints laid in trenches or in floor complete all as specified and as directed.
S&F 100 mm dia cast iron soil waste and vent pipes sand cast in any length with or without ears, with cement joints fixed to wall complete all as specified and as directed.
S&F 75 mm dia cast iron soil waste and vent pipes sand cast in any length with or without ears,with cement joints fixed to wall complete all as specified and as directed
S & F in repairs of 100 mm bore cast iron bends of any radius diminishing pieces or tappers (larger bore measured) complete all as specified and as directed .
S & F in repairs of 75 mm bore cast iron bends of any radius diminishing pieces or tappers (larger bore measured) complete all as specified and as directed
S&F 100 mmbore cast iron cowls complete all as specified and as directed.
S&F in repairs 75 mm diamete of outlet cast iron floor trap with chromium plated grating including jointing to waste pipe with cement joints complete all as specified and as directed.
S&F for 110 mm bore PVC (SWR) pipe single socketed in any length with adhesive joint fixed to wall with suitable clamps of adequate numbers complete all as specified and as directed.
S&F 110 mm bore PVC (SWR) bends complete all as specified and as directed.
S & F for factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet, reinforced with MS square tube fixed in opening complete as per manufacturer's specifications complete all as specified and as directed. Make:- RAJSHRI/SINTEX as approved
S & F for 30 mm thick factory made solid panel PVC door shutter conferming to criteria of testing as per IS : 4020, consisting of frame made out of MS tube of 19 guage thickness & size 19x19mm for stiles and 15x15mm for top & bottom rails MS frames shall have a coat of red oxide primer of approved make and shall be covered with 5mm thick heat moulded PVC `C' channel of size 30x50mm forming styles and 5mm thick 75mm wide PVC sheets for top rail lock rail and bottom rail on either side and 10mm (5mmx2) thick 20mm wide cross PVC sheet as gap insert for top rail and bottom rail panelling of 5 mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rail with 30 mm wide x 5 mm thick PVC sheet beading on either side and joined together with solvent cement, adhesive and an additional 5 mm thick PVC strip of 20 mm width is to be struck on the interior side of 'C' channel using PVC solvent adhesive complete as per manufacturers specifications & drawings ass as directed by Engineer-in-Charge. Make : RAJSHREE/SINTEX as approved
S&F for 100mm long mild steel butt hinges, heavy weight cold rolled mild steel and fixed complete all as specified and as directed.
S&F for 75mm long mild steel butt hinges, heavy weight cold rolled mild steel and fixed complete all as specified and as directed.
S&F 150 mm long aluminium anodised handles, cast typecomplete all as specified and as directed.
S&F for 150 mm long Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed.
S & F 300 mm long aluminium alloy, anodised, sliding dooor bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy.
S&F pressed steel frames of size 125 x 60 mm for doors with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete all as specified and as directed.
S & F pressed steel frames of size 105m x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and as directed.
S&F 35 mm thick 2nd class hard wood glazed/wire gauged/skeleton shutter (well kiln seasoned), the size of rails and style as per IS chemically pressure treated in factory gainst termite infestation prepared to receive wire gauge (without sash bars) edges of frame chamfered or rounded fitted with cut and mitered beads, complete all as specified and as directed. Note : Wire gauge/glazing to be measured and paid separately.
S&F 40 mm thick factory made flush shutter, solid core construction, with block board core and ply wood face panels, commercial type on both sides including one face is covered with decorative face veneer with leeping/ frame to match complete all as specified and as directed.
S&F 2nd class hardwood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and as directed.
S&F 25 mm thick flush shutters, solid core construction, with block board core and ply wood face panels, commercial type on both sides complete all as specified and as directed.
S&F in repairs of 19 mm thick plywood, grade BWR, type BB, fixed with screws to timber frame work etc. in built in cupboard complete all as specified and as directed.
M&L for applying two coat of synthetic enamel paint over one coat of pink primer including preparation of new wood or wood based material of any description over 10 cm in width or girth, not otherwise described complete all as specified and as directed.
M&L applying one coat of synthetic enamel paint including peparation of old painted wooden surfaes of any dscription over 10cm width or girth and complete all as specified and as directed.
M&L applying one coat of synthetic enamel paint including peparation of old painted steel surfaces of any description over 10cm width or girth and complete all as specified and as directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainess steel wire staples complete all as specified and as directed.
S & F for 200 mm long Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed.
S & F mild steel 300 mm ordinary rat tail rod pattern springs including roller & rooler plate complete all as specified and as directed.
S & F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor overall length of cover plate 140mm complete all as specified and as directed.
S & F hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws of 100 mm size complete all as specified and as directed.
S & F in repairs of harrison rail mild steel chromium plated of 19/20mm dia for curtain rod fixed with two Nos of brackets for each rail complete all as specified and as directed.
S & F anodised aluminium powder coated frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc aluminium section weighing should not be less than 1.25 kg/m. complete all as specified. (Note : Minimum thickness of powder coating 50 micron).
S & F anodised aluminium powder coated (minimum thickness of powder coating 50 micron) window and ventilator shutters, hung type without sash bar, aluminium section weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. anodised aluminium fittings such as peg stays 150 mm long (01 No), hinges B-21 100 mm long (02 No), suitable handle (01 No) complete all as specified and as directed.
M&L framed work such as MS grills, guard bars etc with ends of bars sholdered and/or riveted , or forged and similar work including neceassary fixing arrangement to aluminium windows confirming to Fe-290, Gde-E-165 complete all as specified and as directed.
S & F sheet glass 4 mm thick ordinary quality & glazing with rubber gasket in square n.exc 0.5 Sqm in each pane complete all as specified and as directed.
S & F 4 mm thick figured glass, pinhead type in squares n.exc 0.50 sqm each pane complete all as specified and as directed.
S & F 18 mm thick PVC board Rajshree Celuka ply or equivalent as approved of grade 1 quality with both side plain white or coloured fixed with stainless steel screws, solvent cement/ adhesive to fabricate kitchen cabinet sides, top and bottom, door, shelf inside the cabinet and drawer and all fittings complete all as per manufacturer’s instructions and as directed by engr-in-charge. NOTE :-(i) Each member i,e. top and bottom, door, shelf inside the cabinet and drawer etc. shall be measured. (ii) Hinges, wire gauge and handles shall be measured and paid for separately.
S&F auto closing stainless steel (Grade 304) hinges 35 mm of 0 crank (KH-001) or 8 crank (KH-002) openable at 110 degree for kitchen cabinet shutters of make as approvedcomplete all as specified and as directed.
S&F stainless steel handles of 100 mm size for kitchen cabinet shutter complete all as specified and as directed.
Taking down copper/aluminium point wiring (for light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, lamp holders, pendants, regulators, sockets, bell, bell push etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
Taking down old and u/s light fittings conventional type from wall surface / ceiling or any position and making good the disturbed surfaces all as specified and directed.
Taking down old and u/s sub main wiring of 2/3 runs of any sizes from any position including, making good disturbed surface of wall ceiling etc complete all as specified and as directed.
Taking down carefully unserviceable MCB SP/SPN/Isolator of any rating/size complete all as specified and as directed.
Taking down carefully unserviceable DB/meter box any type/size disconnecting and making good disturbed surfaces complete all as specified and as directed.
Disconnecting and taking down old serviceable Energy Meters of any type / capacity after noting down the reading from meter etc. and marking the Quarter No on each meter with permanent marker pen and depositing in MES store for safe custody and writing MES No complete and re-fixing /reconnection in new meter cabinet complete all as specified and as directed.
M&L for concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with and including PVC concealed conduit of medium grade with all fittings including Modular metal flush box minimum 1.6 mm thick, Modular white cover plate with frame, of required module at site, fixed with chromium plated screws and washers for switches and sockets, including 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dolly and including cutting chases in walls / floors for concealed conduit for One light, fan, bell point controlled by one switch and making good disturbed surfaces area by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and directed. Note: - Cutting chase to wall wherever required shall be included in the rate quoted for point wiring.
M&L for concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with and including PVC concealed conduit of medium grade with all fittings including Modular metal flush box minimum 1.6 mm thick, Modular white cover plate with frame, of required module at site, fixed with chromium plated screws and washers for switches and sockets, including 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dolly and including cutting chases in walls / floors for concealed conduit for One 3 pin switch socket outlet point 5 Amps on same board with other switch and making good disturbed surfaces area by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and directed for the following:- Note: - Cutting chase to wall wherever required shall be included in the rate quoted for point wiring.
M&L for concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with and including PVC concealed conduit of medium grade with all fittings including Modular metal flush box minimum 1.6 mm thick, Modular white cover plate with frame, of required module at site, fixed with chromium plated screws and washers for switches and sockets, including 1.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dolly and including cutting chases in walls / floors for concealed conduit for One light point controlled by two 2 way switches and making good disturbed surfaces area by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and directed for the following:- Note: - Cutting chase to wall wherever required shall be included in the rate quoted for point wiring.
M&L for concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with 2.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with and including PVC concealed conduit of medium grade with all fittings including Modular metal flush box minimum 1.6 mm thick, Modular white cover plate with frame, of required module at site, fixed with chromium plated screws and washers for switches and sockets, including 2.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dolly and including cutting chases in walls / floors for concealed conduit for 2.5 sqmm copper conductor cable for One 5 Amps socket outlet on independent board and making good disturbed surfaces area by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and directed Note: - Cutting chase to wall wherever required shall be included in the rate quoted for point wiring.
M&L for concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with 2.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with and including PVC concealed conduit of medium grade with all fittings including Modular metal flush box minimum 1.6 mm thick, Modular white cover plate with frame, of required module at site, fixed with chromium plated screws and washers for switches and sockets, including 2.5 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dolly and including cutting chases in walls / floors for concealed conduit for 2.5 sqmm copper conductor cable for one 3 pin socket outlet, 15 amp independent and making good disturbed surfaces area by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and directed . Note: - Cutting chase to wall wherever required shall be included in the rate quoted for point wiring.
M&L for concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with 4 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with and including PVC concealed conduit of medium grade with all fittings including Modular metal flush box, Modular white cover plate with frame, of required module at site, fixed with chromium plated screws and washers for switches and sockets, including 4 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dolly and including cutting chases in walls / floors for concealed conduit and making good disturbed surfaces by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and directed for Geyser socket 15 Amps on independent board.
M&L for Modular switch 1 way 6A, 1 module, flush button single pole, one way, complete all as specified and as directed.
Supply and fixing Modular socket outlet 2 in 1, 5 pin, 6 Amps flush type white finish complete all as specified and as directed.
M&L for Modular socket outlet 2 in 1, 6 pins 6A and 16A, combined 2 module complete all as specified and as directed.
M&L for Modular switch 1 way 16A, 1 module, flush button single pole, one waycomplete all as specified and as directed.
S & F ceiling rose surface backlite 65x50mm 3 terminals complete.
Supply and fixing lamp holder PVC body with back plate complete all as specified and as directed.
S & F Modular Fan step regulator, 120W - 2 module complete all as specified and as directed.
M&L for Modular bell push 5 Amps 230 V, AC circuit complete all as specified and as directed.
M&L for call bell ding dong 230 V AC circuit complete all as specified and as directed.
M&L for Modular switch 2 way 6A 1 module 230 volt AC circuit complete all as specified and as directed.
S&F 4 Module Gang box including Modular socket outlet 16 Amps for AC, 240 Volts flush type white finish including plug top 20 Amps with modular piano type switch 20 Amps and LED indicator (RED) incl concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with 4 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with and including PVC concealed conduit of medium grade with all fittings and Modular white cover plate with frame 4 module to accommodate all the accessories complete with internal connections, fixed with chromium plated screws and washers for switches and sockets, including 4 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dolly and including cutting chases in walls / floors for concealed conduit and making good disturbed surfaces by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and as directed.
S&F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F LED Light fitting 1x9/10 watt bulkhead luminaire including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
S&F in replacement street light bracket made out of GI Pipe bend to shape 1.5 mtr /40mm dia as required at site) with two Nos clamps made out of 50x6mm flat and two Nos bolts with nuts duly grouted in wall or fixing on wall complete all as specified and as directed.
Supply ,install, testing & commissioning of indoor type, wall mounted (with anchor bolts & nuts) compartmentalized type Meter Cabinet for provision and fixing arrangements of 4 nos. energy meters of overall dimension 1200mm (W) x 750mm (H) x 200mm (D) made out of 2.0 mm thick CRCA Sheet with front door having cut out duly covered with transparent polycarbonate / glass panel for viewing KWh meter / Timer and other door shall be opaque. All doors should have gasket and locking arrangement to meet ingress protection level IP-43. The cabinet shall be painted both internally and externally with powder coated paint (RAL 7032 : SIEMENS GREY) after necessary surface treatment. The cabinet shall be fabricated as per the drawing and comprising of following accessories :-
a) Four pole MCCB, 63 Amps with breaking capacity 16 KA having fixed thermal and fixed magnetic release and spreader link at both incoming and outgoing side.- 01 No. b) Copper Bus Bar of size 25mm x 3mm duly mounted on FRP insulators and necessary drilling for 1 incoming & minimum 6 outgoing connections and duly covered with heat shrinkable PVC sleeves of standard colour code - 4 Nos. c) MCB SPN 16 Amps, 10 KA - 4 Nos ( To be connected with 4 Nos Meters) d) MCB SP 06 Amps, 10 KA -2 No ( For common lighting & Bldg Security Lights) e) Analog time switch 16 Amp-01 No f) LED indicating Lamps, 22mm with 3 Amps SP MCB-03 Nos. g) 3 Way Bakelite strip type cable connector 30 Amps rating - 06 Nos h) Dial type DIN rail mounting, Analog Time Switch 16 Amps / 230 Volts AC 50Hz, with battery back up, 24 Hrs programmable type with 1 NO & 1 NC output contact.- 01 No. (for security light). j) Internal wiring with 1100V grade FRLS PVC insulated multi flexible copper wire of sizes duly crimped with copper lugs of suitable size & type all as mentioned below :- i) MCCB to Bus Bar - 10.0 Sqmm copper ii) Bus Bar to Cable Connector via KWh meter and MCB - 6.0 Sqmm iii) Bus Bar to LED Lamp via MCB - 1.5 Sqmm
S&F factory made epoxy powder coated distribution board SPN 8 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, stranded DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified and as directed..
S&F MCB single pole 240 volt 'B' curve 10 KA 5 to 16 Amps capacityincluding taking out existing MCB complete all as specified and as directed..
S&F MCB single pole & neutral 240 volt 'C' curve 10 KA 16 Amps complete all as specified and as directed.
M&L for concealed sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6.0 Sqmm of voltage rating up to and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 25mm with all fittings and accessories, along with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6.0 Sqmm (green colour) as earth continuity conductor acomplete all as specified and as directed. Note :- Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit
M&L for taking down carefully existing ceiling fan from site before B/R repair work, keeping in safe custody in store for greasing / oiling of ball bearings / bushes and making it for smooth and noise free operation and painting with Hi-Gloss synthetic enamel paint of approved shade by spray painting after filling cavities and re-fixing after providing new fan clamp, nuts/bolts, washers, down rod as required and provision of 3 core copper flexible cable of size 1.0 Sqmm from ceiling rose to fan connector complete with writing of MES No. on the fan surface complete all as specified and as directed.
S&F exhaust fan steel body, heavy duty, double ball bearing, Copper wounded complete with louvers shutter, 230 volt AC, single phase, 50 Hz, 1400 RPM, 300 mm sweep with blades, steel frame complete all as specified and as directed.
S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutters , 250 mm sweep, single phase, 230 Volts AC,1200 RPM, ISI marked fixed properly at directed location with provisioning of suitable fixing/tightening arrangements and connecting/testing and including writing MES No complete all as specified and as directed.
Cutting the existing wall/removing existing steel bar to make a hole for fixing of ventilation fan through packing of wooden ply to support the ventilating/ air circulating fan including necessary nut and bolts of suitable size incl making good of disturbed surface complete all as specified and as directed.
M&L for taking down carefully existing geyser of any type and cap from site before B/R repair work, keeping in safe custody in store for servicing and painting with Hi-Gloss synthetic enamel paint of approved shade by spray painting after filling cavities, writing of MES No. and re-fixing with new hot and cold water connection as required incl provision of 3 core copper flexible cable of size 4 Sqmm complete with 15 Amps 3-pin plug top complete all as specified and as directed.
Supply and fix in replacement cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable(heavy duty ) under ground cable with 1100 volts grade with stranded aluminium conductor of sizes 16 Sqmm 4 core ccomplete all as specified and as directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m deep and getting out in loose / soft soil for under ground cable / erection of poles, stays etc complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and as directed.
Removing of excavated material to a distance not exc 50 m and depositing where directed at a level n. exc 1.5 m above the starting point complete all as specified and as directed.
M&L for laying of bricks subclass ‘B’ old size designation 75 ,laid flat perpendicular to the direction of cable for protection of cable complete all as specified.
M&L for sand cushioning for cable with river washed sand and punning down as required complete all as specified and as directed. Note:- Punned thickness shall be measured for payment purpose.
M&L earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, buried directly in to ground ( earth pit) not less than 2.25 metres deep below GL with top edge of earth plate opt less attn. 1.50 m below ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, connected to GI lead wire of 4 mm dia.(7.50 m Long) by means of nuts, bolts and washers, check nuts of GI and protected by the GI pipe light grade 15 mm nominal bore(7.5 m long) for earth lead wire and watering pipe light grade of 20 mm nominal bore, 0.63 mm thick G I sheet funnel , wire mesh, earthing test point etc complete including necessary earth work and excavation in any type of soil , PCC 1:2:4 type B1 earth pit and Precast RCC cover 65 mm thick duly reinforced with 8 mm diaTMT bars @ 100mm C/C both ways, with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SI Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
MITHILA BUILDERS AND ENGINEERS
M/S ABHAY KUMAR AND BROTHERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .