Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.0 LAccepted-AOC | L1 | Accepted-AOC Low | |
| 2 | L2₹26.7 L+₹1.7 L (6.86%)Rejected-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L2 | Rejected-AOC High |
Tender Value
₹29.0 L
EMD Value
₹57,920
Closing Date
5 Feb 2024, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh Sachin Jaiswal, IDSE, Cwe Chandimandir
HQ CWE Chandimandir
CA NO. CWE/CHM(U)-89/2023-24 PROVN OF RING MAIN H/T SUP CIRCUIT FOR LADAKH SCOUTS BN AREA AT CHANDIMANDIR MIL STN
2024_MES_636214_1
CWE/CHM(U)-89/2023-24
Open Tender
Miscellaneous Works
Item Rate
180 days
HQ CWE Chandimandir
Class D category b(ii)
8 documents required · 8 mandatory
₹500
Yes
GE(U) Chandimandir
₹57,920
Yes
1 Mar 2024
6 Jan 2024
9 Feb 2024
6 Jan 2024
5 Feb 2024
22 Jan 2024
8 Jan 2024 - 13 Jan 2024
Amount
Excavation in trenches in any type of soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for laying of cable, poles etc. and getting out complete all as specified and directed by Engineer-in-charge.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each complete all as specified and directed by Engineer-in-charge.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed by Engineer-in-charge.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 flat , size 300mm x 180mm x 40mm complete all as specified and directed by Engineer-in-charge.
M&L for providing dry river sand as in sand cushioning below and above cable thickness as specified in SSR to under ground cable including punning down of sand in layer all as specified and directed by Engg-in-Charge. Note: Only punned thickness of sand will be measured and paid.
Supply, Fixing and testing XLPE insulated, screened PVC bedded, galvanised steel strip armoured, heavy duty HT power cables aluminium conductor, cross sectional area 95 sqmm 3 core, 11000 volts grade, ISI marked, in trenches, ducts or fixing along the poles or passing through pipes or laid under floors etc complete all as specified and directed by Engineer-in-charge.
S & F HT heat shrinkable type indoor end termination cable jointing kit with jointing material and accessories sutable for 11000 volt (Earthed) grade XLPE cable of size 95 Sqmm, 3 core complete all as specified and directed by Engineer-in-charge.
Supply & Fixing GI tubes, 100 mm bore, light grade for cable protection on poles/ walls/ under road/ culvert etc complete all as specified and directed by Engineer-in-charge.
M & L for horizontal boring under road for passing cables manually or using mechanical devices complete all as specified and as directed.
Supply & Fixing Cast Iron Cable Route Indicator for HT cable, disc type of size 150 mm dia, 8 mm thickness embossed with " MES HT CABLE" and fixed on angle iron 35 x 35 x 5 mm, 600 mm long as directed and painted in anti corrosive brown color paint incl PCC 1:2:4 type B-1 foundation block of size 300 x300 x 300 mm, duly fixed in ground complete all as specified and as directed.
Supply, install, testing and commissioning of 11 KV 630 Amps 21 KA for 3 sec SF6 insulated, one side extensible outdoor duty 4 way Ring Main Unit (RMU), completely motorized as well as manually operated in combination of 2 No VCBs as Incomer and 2 nos VCB as outgoing alongwith bus PT metering module, consisting of copper busbar in SF6 insulated 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5 mm with manometer fixed, with series trip, self-powered microprocessor based numerical over current relay (IDMTL+Inst.) with Modbus protocol compliant RS485 port for overload/ earth fault/ Transformer protection & short circuit protection in each VCB feeder. Item No. 11.00 contdd..
The breaker shall have mechanical ON /OFF indicator with hand trip device and spring charging, spring release coil, auxiliary switch of 2 NO +2NC. The HV switchgear and control gear should be confirming to IEC-62271-100, IEC-62271-200-2003 & IEC-60694-1996. The RMU should be internal arc tested for 21 KA for 1 second with IAC-AFL classification for gas tank and gas to be released from the rear top or rear bottom from operator end. The complete RMU along with cable chamber to be put to an outdoor enclosure to have ingress protection of minimum IP54. Each feeder should have voltage presence indicator. RMU Should have 01 no manometer for each tank and the followings:
[a] For each VCB - Vacuum circuit breaker module with vaccum circuit breaker 12 KV 630 amps, three position isolator/earthing switch, bus bars, interlocking , earth bar and stored spring energy mechanism with and including the followings:- [i] 1 no. microprocessor based self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder. [ii] 3 Nos. Protection ring core CTs of Burden 2.5VA, ratio 100-50/1A, Class of Accuracy class 5P10 of IS 2705-part III 1992 for O/C and E/F protection for each VCB.
[iii] Right angle boots for all the feeder Modules [iv] Mechanism for manual and motorised operation. [v] Cable cover standard for interlocking. [vi] Cable bushing interface C (400 bolted) , 630 A, at site replaceable type [vii] Aux switch for VCB connected position 2NO + 2NC. [viii] Aux switch for disconnected position 2NO + 2NC [ix] Capacitive voltage indication fixed type VPIS 6-12 KV [x] Cable support bars, standard for one way unit. [xi] Aux switch for earth switch position 2NO + 2NC [xii] 3 Nos. metering CTs of Burden 2.5VA, ratio 100-50/1A, Class of Accuracy 0.5 for MFM in each VCB Module. (for incoming VCBs only) and 1 No digital trivector meter for each incoming VCBs only.
[b] BUS PT metering module - Air insulated metering module 12 KV 630 amps with the following :- [i] 3 Nos 12 KV single phase epoxy cast resin voltage transformer ratio - 12/rt3/110V/rt3, 50 VA burden and accuracy class 0.5. [ii] Battery and charger of 24 V DC for all module motorized operation. [iii] Indicator lamps for R Y B phase indication. Note - RMU shall be installed on a suitable PCC 1:2:4 type B-1 (20mm graded stone aggregate) foundation as per manufacturers instructions and unit rate quoted shall be deemed to include the cost of the same. 230V single phase electric supply shall be available at site within a radius of 100 Meter. Required cable/MCB etc of suitable size for connection shall be arranged by the contrator at his own cost.
Earthing complete with galvanised steel earth plate electrode 60x60cmx6 mm thick burried directly in ground ( earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised earth lead strip 32x6mm dia by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 5 of SSR Part-I 1991 connected to earthing test point panel all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil, funnel, PCC chamber (1 : 3 : 6) type C1, CI pit cover and frame , charcol, salt including earth lead protected by 40 mm dia medium grade GI pipe and 20mm dia medium grade GI Pipe for watering complete.
Note :- Earth lead strip 32 x 6 mm and GI 40 mm dia protecion pipe upto 7.5 mtr length will be deemed to include in the unit rate quoted.
R D Bansal
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .