Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹3.2 L+₹75,496 (30.7%)Rejected-Finance | L2 | Rejected-Finance HIGHEST | |
| 3 | Rejected-Technical | - | Rejected-Technical REJECTED |
Tender Value
₹3.0 L
EMD Value
₹3,000
Closing Date
5 Aug 2021, 3:00 pmClosed
Amit Manuja
Executive Engineer, Provincial Division No.1, PWD B and R, Kurukshetra
Special repairwork of SDE office Pipli and Parking area at Kurukshetra under Provincial Division No.1, PWD B and R, Kurukshetra
2021_HRY_181676_1
PWD/AMB/KKR-1/110150
Open Tender
Construction Works
Works
30 days
Kurukshetra
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
₹3,000
15 Sept 2021
30 Jul 2021
5 Aug 2021
30 Jul 2021
5 Aug 2021
30 Jul 2021
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. All kinds of soil (HSR 4.12.1)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1 :4: 8 ( 1 Cement : 4 coarse sand (zone-Ill) : 8 graded cum stone aggregate 40 mm nominal size) (HSR 6.1.6)
Brick work with common burnt clay non-modular bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement: 4 coarse sand) (HSR 7.21.1)
Providing and Fixing Poly Carbonate Sheet 1.25mm thickness on Gates and grills excluding the cost of MS framework but including the cost of nut bolts, Welding rods complete in all respect as per direction of Engineer-in-Charge. (HSR 13.20)
Providing and Laying 80 mm thick ISi marked lntertocking Paver Blocks conforming to IS 15658:2006/IRC SP 63: 2004 of all shapes and colours in design mix cement M 40 over the bed of 30 mm thick fine sand complete in all respect. (HSR 17.69.2)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes (HSR 13.30.1)
D. REINFORCED CEMENT CONCRETE 6.14 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level: 1 : 1. 5: 3 ( 1 cement : 1. 5 coarse sand (zone-Ill): 3 graded stone aggregate 20 mm nominal size) (HSR 6.14.1)
VITRIFIED FLOOR TILES Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1 :4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including Size of Tile 600x600 mm (HSR 10.63.2)
Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete. (HSR 11.58)
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer. (HSR 11.67.1)
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. (HSR 30.22)
Distempering with 1st quality acrylic distemper (Ready mix) having voe content less than 50 grams/ litre of approved brand and manufacture to give an even shade: Old work (one or more coats) (HSR 30.25.1)
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One or more coats on old work (HSR 30.27.1)
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-inCharge. With cement mortar 1 :4 ( 1 cement : 4 fine sand) ( HSR 30.16.1)
WASH BASINS, KITCHEN SINKS AND HARDWARES Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White vitreous chinaware Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap (HSR 22.1.2)
Providing and fixing white vitreous chinaware pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISi marked white solid plastic seat and lid (HSR 22.23.1)
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore (HSR 22.104.1)
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore (HSR 22.106.1)
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore (HSR 22.107.1)
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. (HSR 22.109)
Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISi : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately. (HSR 22.182)
Providing and Fixing Poly Carbonate Sheet 4 mm thickness for parking shed excluding the cost of MS framework but including the cost of nut bolts, Welding rods complete in all respect as per direction of Engineer-in-Charge. (NS)
SHRI MATA MANSA DEVI L/C SOCIETY LTD
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .