Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.8 LAccepted-AOC | L1 | Accepted-AOC Being a lowest bidder | |
| 2 | L2₹34.7 L+₹1.2 L (3.59%)Rejected-Finance 121004 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹35.3 L+₹1.7 L (5.15%)Rejected-Finance BHANGARMATH THAKURANI CHAWK PO SAMABYPALLY BALLY HOWRAH 711 205 WEST BENGAL | HOWRAH | WEST BENGAL | 711205 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹35.5 L+₹2.0 L (5.94%)Rejected-Finance P 45 KHIRODE VIDYA BINOD AVENUE KOLKATA 700003 | KOLKATA | WEST BENGAL | 700003 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹35.6 L+₹2.0 L (6.08%)Rejected-Finance VILL PUILLYA PO UNSANI DISTT HOWRAH PIN 711302 | HOWRAH | WEST BENGAL | 711302 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹31 L
EMD Value
₹62,000
Closing Date
15 Feb 2022, 6:00 pmClosed
GE(FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
SPL REPAIR TO BLDG NO F 4 AND F 5 IN OLD BAPU LINE UNDER GE(FW) KOLKATA
2022_MES_503726_1
8821/E8
Open Tender
Civil Works
Item Rate
180 days
GE(FW) Kolkata
Ref tender documents
6 documents required · 6 mandatory
₹500
GE(FW) Kolkata
₹62,000
28 Feb 2022
25 Jan 2022
16 Feb 2022
25 Jan 2022
15 Feb 2022
8 Feb 2022
Amount
SCHEDULE 'A' PART - I (B/R WORKS) Excavation in trenches not exc 1.5 metre width and not exceeding 1.5 metre in depth in soft/loose soil and getting complete all as specified and as directed.
Dismantling of AC corrugated/semi corrugated sheets including ridge as in roof covering and removing off the site complete all as specified and as directed.
Dismantling of plain corrugated steel sheeting any gauge, thickness, including nainital or similar pattern roof covering & removing off the site.
Demolition Cement Concrete (reinforced) in any postion complete all as specified and as directed.
Demolition of Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, complete all as specified and as directed.
Taking down Cement Plaster of any description on Brick Walls, Concrete Surfaces including racking out joints, hacking for key, scrubbing down with Water, remove dust, debris/ rubbish, etc., complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling structural steel work of any description including doors, gates, railing etc but excluding framed trusses complete all as specified and directed.
M&L 15 mm thick rendering in cement mortar (1:6) to brick or concrete wall surfaces, finished even and smooth without using extra cement complete all as specified and as directed.
M&L rendering 15 mm thick cement plaster in two layers each of 10+5 mm thick on one side of lathing in cement mortar (1:4) & second layer mixed with water proofing compound @ 3% by weight of cement, finished fair and even complete all as specified and directed. (Note -W.P.C. shall be measured and paid seperately)
M&L 5 mm thick rendering in cement mortar (1:3) to ceilings, finished even and smooth without using extra cement including necessary scaffolding complete all as specified and as directed.
S&F 0.50 mm thick TCT (total coated thickness) pre-coloured galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high rib/multi rib profile galvalume sheeting having 1000-1020 mm width and 28-30 mm high crest @ maximum 250-255 mm pitch (centre) with sheets manufactured out of 0.50 mm this TCT (total coated thickness) high tensile galvalume sheets having tensile strength 550 MPA with 18-20 micron top coat over 5 micron primer and 8-10 micron alkyld backer zinc aluminium alloy AZ-150, sheets having a dip metallic zinc (43.5%0 aluminium (55%) & silicon (1.5%) with total mass coating of 150 gms/sqm on both sides, having wide pans with minimum 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support and fixed as per existing profile of roof complete all as specified and directed.
All as per Item No. 12 above but 0.50 mm thick coloured plain galvalume sheet as in ridge/valley gutter of roof.
S&F 6 mm thick asbestos cement, corrugated sheet in roof, wall fixed with L type or J type hook complete all as specified and directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) area exc 1.5 Sqm and n.exc.4.00 Sqm each wooden all as directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) area n.exc. 1.5 Sqm each all as directed.
S&F for 2nd class hardwood, plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, moulded or chamfered, put together with glue, pinned at joints complete all as directed.
S&F Factory made 35mm thick with 2nd class hard wood, rail and style factory made plain framed panelled shutter(two panel) with lock, rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail & style as per IS:1003(Part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F 35mm thick Factory made 2nd class hard wood glazed & skleton shutters, open rebated and prepared to received glass, gauge etc.(without sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc, size of members of shutters as specified in SSR Part-I section 8, clause 8.20(a) complete all as specified and directed.
Preparing new surface of wood or wood based material of any description and in any position not otherwise described n.exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of wood primer complete all as directed.
M&L for preparing surfaces of wood and wood based materials, steel and iron work, new or old, of any description and girth, treating ends of posts, back of chowkhats etc, with tar or coal tar black paint, area tarred exc 0.1 sqm but n. exc 0.5 sqm each complete all as specified and directed.
-ditto- but treating small articles such as holdfasts, ends of posts, back of chowkhats, etc, area n exc 0.1 sqm each
Preparing old treated surfaces of wood or wood based material of any description and in any position not otherwise described n.exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as directed.
M&L mild steel work in tubular trusses including special shaped washers etc complete using ERW or induction butt welded tubes conforming to IS-1161:2014 grade St-240 complete all as specified and directed. (NOTE: Quoted rates shall be deemed to include for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete)
M&L for Rolled mild steel in joist, angle, channel or tee sections, fixed independently without connecting plates etc. (cut to ordinary length i.e. within 20 mm of the length indicated) Gde Fe 410W complete all as specified and as directed.
M&L TMT Bars 10 mm dia and over, cut to length, bent to shape required including crank-ing, bending and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm, complete all as specified and as directed.
M&L for TMT bars 5 mm dia and over upto and including 10 mm dia in stirrups , spacers and binders cut to length , bent to shape required as in reinforcement and binding with MS wire (annealed) not less than 0.90 mm dia complete all as specified and directed .
M&L for RCC 1:1½:3, type A1 (nominal mix) (using 20mm graded stone aggregates) as in beams, cantilevers, bressummers, lintels over 1.5 mtr span complete all as specified and directed. (Note : Reinforcement to be measured and paid separately).
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressumers, lintels, cantilevers, shelves etc for fair finished surfaces complete all as specified and directed.
M&L Brick Work with fly-ash Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed.
M&L Brick Work with fly-ash Bricks Half-Brick thick, Old Size, built in Cement Mortar 1:4, Straight or Curved on Plan to any Radius, complete all as specified and as directed.
Supply only liquid water proofing compound all as specified and as directed.
M&L for applying two coats of synthetic enamel paint over a coat of Red oxide, zinc chrome primer to new steel surfaces of any description over 10 cm width or girth including preparation of surfaces all as specified and directed by Engineer-in-Charge.
M&L for applying one coat of synthetic enamel paint to old decorated steel surfaces of any description over 10 cm width or girth including preparation of surfaces all as specified and directed by Engineer-in-Charge.
M&L for hardcore of gauge not exc 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to true surface with broken stones complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B2 (using 40 mm graded aggregates) in foundation filling and mass concrete complete all as specified and directed.
M&L for plain cement concrete (1:3:6) type C2 (using 40 mm graded aggregates) in foundation filling and mass concrete complete all as specified and directed.
M & L for Providing precast cement concrete Type B1 1:2:4 (20mm graded aggregate) Set in cement mortar 1:4 in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including necessary forms, moulds, etc complete all as specified and as directed. (Note : Reinforcement to be measured and paid separately).
M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of old decorated surfaces of walls and applying one coat of cement base paint complete all as specified and directed.
M&L for preparation of new plastered of wall surfaces and applying two coats of acrylic distemper over a coat of alkali resistant primer complete all as specified and directed.
S&F stainless steel wire cloth, 0.65mm nominal dia of wire and average width of aparture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
. - ditto - all as per item No. 42 here-in-before, but fixed in repair.
Hacking out old broken glass (any thickness and size or quality) from wooden frames glazed with putty or fixed with beads complete all as specified and directed.
. - ditto - all asper item No. 44 here-in-before, but from metal frame.
S&F 3mm thick ordinary quality plain sheet glass glass and glazing in square n.exc. 0.5 Sqm in each pane on wooden windows complete all as specified and directed.
-ditto- but in metal frames with oil putty
S&F 150mm aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
- ditto - all asper item No. 48 here-in-before, but 200mm long all as directed complete all as specified and directed.
S&F 300mm aluminium, anodised sliding door bolt with hasp, staple(bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy all as directed complete all as specified and directed.
- ditto - all as per item No. 50 here-in-before, but fixed in repair.
S&F 100mm butt hinges stainless steel medium weight
- ditto - all as per item No. 52 here-in-before, but 75mm.
S&F aluminium handle, cast type anodised 125mm size all as directed.
- ditto - all as per item No. 54 here-in-before, but 150mm.
S&F steel window with side hung shutter including necessary hinges with steel handle and steel peg stay complete with glazing bars devotailed or welded all as directed. (NOTE: Sheet glass will be measured and paid seperately)
SCHEDULE 'A' PART-II (INTERNAL ELECTRIFICATION) Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants, regulators, sockets etc excluding light fitting for taking credit removing from site and making good disturbed surface of walls, floors etc.complete all as specified and directed.
Taking down of old Submain wiring any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed.
Taking down of Old MCB DB any type any size including MCCB/RCCB/MCBs and disconnecting the serviceable MCBs and keeping in safe custody for reuse at site.
M&L for surface type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing capping medium duty complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed.
All as per item No. 60 above but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (surface type point wiring with terminal box).
All as per item No. 60 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (surface type point wiring with terminal box).
All as per item No. 60 above but using 2.5 sqmm single core multi stranded copper conductor FRLS PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLS PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (surface type point wiring with terminal box).
S&F switch piano flush button AC 230 V Single pole 5/6 Amp one way complete all as specified and directed.
S&F socket outlet 2-in-1, 3 pin, 6 Amp AC 230 Volts flush type complete all as specified and directed.
S&F switch socket combination, 5 pin, 6 Amp AC 230 Volts flush type complete all as specified and directed.
S&F switch socket combination 2 in 1, 3 pin, 6 and 16 Amps flush type universal complete all as specified and directed.
S&F ceiling rose surface, polycarbonate/bakelite, three terminals complete all as specified and directed.
S&F electronic type stepped speed regulator, 100 watts, AC 230 Volts for ceiling fan, complete all as specified and directed.
S&F surface mounted LED luminaire, 1 X 20 Watt in aluminium housing, operating voltage 180-270 V, with acrylic/polycarbonate difuser & integrated constant current electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper wire of suitable size complete all as specified and directed. complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation
-ditto- as per Item No. 70 but of 1 X 9/10 Watt capacity in polycarbonate housing with lumen output not less than 105 lumen per watt
M&L for sub main wiring with 2 run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through and incl PVC casing-caping of suitable size, surface type complete all as specified and directed. (NOTE : Three runs of single core 4.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
All as per Srl. Item No. 72 above but with two runs of 2.5 Sqmm cable and one run of 2.5 Sqmm as earth continuity conductor in PVC casing capping (NOTE : Three runs of single core 2.5.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
S&F TPN DB, IP 43 protection, double door (premium quality), 415 volts, 4 way (8+12), with 100 Amps copper bus bar for each phase complete all as specified and directed. (MAKE : L&T, Cat No. DBTPN004DD / LEGRAND, Cat No: 507670 / SCHNEIDER, Cat No. A9HTND04 / ABB, Cat No: E-SHDB M4 / PANASONIC, Cat No: BQS 304H / HAGER, Cat No: VYT04DH)
S&F Double Door, Sheet Metal Enclosure for DBs (normal range), for mounting of MCB for 240 Volts, 8 way, with 100 Amps rated copper bus bar, Single Pole & Neutral, complete all as specified and directed. (MAKE : C&S, Cat No: CSDBSPNPDD08 / BCH, Cat No: BCHSPNDD08W / HPL, Cat No: MDBDD08 / HAVELLS, Cat No: DHDPSHODRW08 / INDO ASIAN, Cat No: 811807)
S&F SPN DB, IP 43 protection, double door (normal range), 240 volts, 4 way, with 100 Amps copper Bus Bar complete all as specified and directed. (MAKE : C&S, Cat No; CSDBSPNPDD04 / BCH, Cat No: BCHSPNDD04W / HPL, Cat No: MDBDD04 / HAVELLS, Cat No: DHDPSHODRW04 / INDO ASIAN, Cat No: 811824)
NOTE FOR ITEM NO. 74 to 76 :- (1) Incoming MCCB/RCCB/MCB and outgoing MCBs shall be measured & paid seperately as "Supply Only". (2) Quoted rate is deemed to be inclusive of blanking plate for slots remaining blank after fixing of MCBs. (3) DB, MCCB, RCCB & MCB shall be of the same manufacturer.
S&F MCB (premium quality), 'C' series, TPN, 415 volts, 63 Amps, breaking capacity 10KA complete all as specified and directed.
S&F MCB, 'C' series, SPN, 40 Amps, breaking capacity 10KA complete all as specified and directed.
S&F MCB, 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed.
Taking down ceiling fan 1200 mm to 1400 mm sweep of any make sealing cable ends, dismantling blades, applying one coat of synthetic enamel paint by spraying after cleaning thoroughly with kerosene oil including filling cavities with filler etc, hanging the ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan, complete all as specified and as directed by Engr In Charge. (Note:-Cost of repairs / rewinding of motor will be measured and paid separately)
S&F in repair Capacitor 2.5 mfd, 230 Volts, AC, 50 Hz, complete all as specified and as directed.
S&F in repair Ball Bearing of suitable size for Ceiling Fans 1200 mm to 1400 mm sweep complete all as specified and as directed.
S&F in repair MS down rod of size 15/20 mm dia and length 2' for ceiling fan including electric connection, nut, bolt and clamp as in repair complete all as specfied and directed.
S&F in repair MS down rod of size 15/20 mm dia and length 3' for ceiling fan including electric connection, nut, bolt and clamp as in repair complete all as specfied and directed.
S&F in repair D clamp of strip size 25x6 mm with suitable washer, nuts, bolts in any shape or size as indicated or directed and inclusive of one primer coat ,one under coat, one finish coat of paint complete for hanging of ceiling fan all as specified and as directed.
S&F of rubber reel 1.7/2.5 insulator for Ceiling fan suitable for 1200/1400mm sweep complete all as specified and directed.
M&L for Rewinding of ceiling fan 1200/1400mm sweep of any make with super enameled copper winding wire as per existing size and gauge including heating, varnishing and testing, complete all as specified and as directed.
S&F ventilating fan 250 mm sweep, and connecting up including provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 0.50 Sq mm, 3 core, 1100 Volts grade, from ceiling rose to fan complete all as specified and directed. (MAKE : HAVELLS, Model : Venti Air DX / CROMPTON, Model : Brisk Air / HALONIX, Model: HELION DX / USHA, Model: CRISP AIR or equivalent model in BAJAJ / ORIENT)
SCH 'A' PART-III (EXTERNAL ELECTRIFICATION) S&F in repair Bracket/Arm suitable for street light fittings, made out of 32 mm bore (light grade) GI pipe length not exceeding 1.5 metre long, fixed with 02 sets of flat iron clamp of size 32mm x 6 mm, with bolts, nuts and washers of suitable size including applying two coats of aluminium paint over a coat of red oxide zinc chrome primer incl taking down existing bracket complete all as specified and as directed by the Engr-in-Charge.
S&F in repairs PVC insulated & sheathed stranded copper cable 3 core of cross sectional area 1.5 Sqmm for providing necessary electrical connection from junction box to light fittings including with suitable size copper lugs incl taking down existing cable complete all as specified and as directed.
Supply and fix in repairs LED Street Light fitting 35W/36W, in pressure die cast aluminium housing with lens and toughened glass cover with integrated constant current electronic driver, incl taking down existing fitting complete all as specified and directed and complying with the following specifications:-. (a) minimum efficacy 110 lumen/watt (b) CRI not less than 70, (c) THD < 30% (c) having in built short circuit and surge protection upto 5 kV (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation (f) Weather protection grade: IP66 (NOTE: (1) List of approved makes has been provided in particular specifications. Contractor shall ensure that luminaire provided comply with the aforesaid specifications. No claim shall be entertained during currency of work.. (2) Wire for electric connection shall be measured and paid separately)
Supply, Laying and testing XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable of size 10 sqmm 4 core, laid in trench or fixed to wall/passing through pipe/pole complete all as specified and directed. (Note :- Necessary earth work, if required, shall be measured and paid separately.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized iron strip 25 X 4 mm (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing and dismantling of existing unsv earthing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
GHOSH ENTERPRISE
dutta and dutta
UNIVERSAL TRADING CENTRE
PRABIR TRADERS
B & R CONSTRUCTION
MS HORIZEN
JAGATMATA ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .