Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 LAccepted-AOC 256 MUNDHELA KHURD NEW DELHI 73 | WEST | DELHI | 110008 | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.8 L+₹11,655 (2.05%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹5.9 L+₹18,294 (3.22%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹6.7 L+₹1.0 L (17.9%)Rejected-Finance | L4 | Rejected-Finance Rejected |
Tender Value
₹6.8 L
EMD Value
₹11,350
Closing Date
22 Feb 2024, 10:00 amClosed
Atul Bhardwaj
Hauz Khas
Installation of Semi High Mast Llight Poles with LED flood light and Street Lights and at various locations in ward no. 151 of Munirka under south zone
2024_MCD_186289_1
MCD/TR/10449/2023_6_1_1/1
Open Tender
Electrical Works
Item Rate
45 days
South Zone
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹11,350
5 Apr 2024
15 Feb 2024
22 Feb 2024
15 Feb 2024
22 Feb 2024
15 Feb 2024
Amount
Part A Approved WITH DSR 2022
122.2.19:Fabrication,Supplying,Installation,testing,Commissioning of 12 mtr high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized 4mm thick(Single dip ) inside & out sides &suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circumferential weld. It should also included accessories For High Mast head frame ,2 point suspension system, 5*2.5 sqmm Cu conductor with steel wire rope 5mm dia. (7/19construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. Flood Light luminaries symmetrically And its control gears boxes and lighting finial ,the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC (1:2:4) shallow foundation of size 1m(L) x 1m wide and 2m deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -2100mm long (approx.) - 16 nos.and reinforcement of cold twisted bar of 8 mm dia - 3700 mm (approx.) - 13 nos. (with 150 mm spacing) as required with positioning of foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for the high mast considering The safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c 4Nos S.P MCB,63Amp.DPIsolator etc as reqd. Logo/Name of manufacturer shall be embossed on the pole. Galvanization as per relevant IS.
122.2.25:Providing and fixing of Stainless steel name plate of size 6×8 sq inch made of 20 gauge sheet including engraved name of area representative duly painted along with SS clamp nut bolt etc as required
122.2.26:Providing and fixing FRP Fencing at Electrical Installations with necessary concreting for grounding vertical post, hardware. Accessories, fitting, etc of 2000 mm height above the ground and 300 mm grounding in ground minimum along with fencing 1 number of FRP gate with necessary hardware, accessories, brass/stainless steel metal lock fittings etc of suitable length, width & height, width & height i.e. 1 number gate as per site requirement.
OD22475/2023-2024:14.16.1 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal)
OD22476/2023-2024:5.18 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
OD22477/2023-2024:5.1 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
OD22478/2023-2024:7.6.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm
OD22479/2023-2024:7.5.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
122.1.2:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm
Part B CIVIL DSR
110.10:Providing and fiving name board made of MS Sheet 90x60cm, 1mm thick with frame of MS angle 50x50x6mm, two diagonal braces at the back of the sheet of MS flat 40x6mm, total height of the board above ground level 2.40m, length of legs below ground 0.30m embedded in CC block 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) 30x30x45cm including excavation and removal of surplus earth with in 50m lead, applying priming coat of approved steel primer, painting with synthetic enamel paint of approved quality and lettering with enamel paint of approved colour (one side) as per drawing/direction of Engineer-in-Charge
Vivek Electricals
Pee Kay Electric Works
SHARMA ELECTRICALS
Bidder Name
Pee Kay Electric Works
M/s New Gupta Electric Works
Vivek Electricals
SHARMA ELECTRICALS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .