Chief Engineer Bathinda Zone
Headquarters Chief Engineer Bathinda Zone Military Engineer Services PIN- 900484 C/o 56 APO
SPECIAL REPAIRS/ REPLACEMENT AND UPGRADATION OF EXISTING OLD TRANSFORMER AGAINST BER ALONGWITH CONNECTED ACCESSORIES AT BATHINDA MIL STN UNDER GE (UTILITY) BATHINDA
2026_MES_794482_1
84601 CA NO CE BTZ/BTD/TOKEN-27 OF 2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bathinda Mil Stn
As per Notice Inviting Tender (NIT)
7 documents required · 7 mandatory
₹1,000
GE (U) Bathinda
₹2.3 L
Yes
Headquarters Chief Engineer Bathinda Zone
16 Oct 2026
16 Oct 2026
16 Nov 2026
17 Oct 2026
14 Nov 2026
6 Nov 2026
16 Oct 2026 - 14 Nov 2026
9 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed. | 141.75 | Cum | - | - |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed. | 98.23 | Cum | - | - |
| 3 | Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point | 43.52 | Cum | - | - |
| 4 | Supplying, installing, connecting, testing & commissioning mineral oil immersed, natural air-cooled, indoor type, double wound (copper) distribution transformer, three phase, 250 kVA rating, non-sealed type, 50 Hz rated frequency, 11 kV high voltage and 415 V low voltage nominal system voltage, minimum 75 kVp basic insulation level, 11000 V/ 433-250 V no-load voltage ratio, connection (vector) symbol Dyn11, 30⁰ positive phase displacement, off circuit tap changing arrangement for voltage variations of +5% to -10% in steps of 2.5% for variation of HV, minimum energy efficiency level 2 (Star 2 as per the notification issued by the Central Government, in consultation with the Bureau of Energy Efficiency and including all the amendments issued up-to-date), 4.5% impedance, ONAN type cooling all as per IS-1180 (Part 1): 2014 including amendment upto and including amendment No. 4 dated 04 Mar 2021 complete with all fittings, accessories and item as specified and as directed. Note: - The energy efficiency level higher than the minimum energy efficiency level as specified here shall be provided without any extra cost in case the transformer of minimum energy efficiency level is not available. | 2 | Each | - | - |
| 5 | Supplying, installing, connecting, testing & commissioning mineral oil immersed, natural air-cooled, indoor type, double wound (copper) distribution transformer, three phase, 400 kVA rating, non-sealed type, 50 Hz rated frequency, 11 kV high voltage and 415 V low voltage nominal system voltage, minimum 75 kVp basic insulation level, 11000 V/ 433-250 V no-load voltage ratio, connection (vector) symbol Dyn11, 30⁰ positive phase displacement, off circuit tap changing arrangement for voltage variations of +5% to -10% in steps of 2.5% for variation of HV, minimum energy efficiency level 2 (Star 2 as per the notification issued by the Central Government, in consultation with the Bureau of Energy Efficiency and including all the amendments issued up-to-date), 4.5% impedance, ONAN type cooling all as per IS-1180 (Part 1): 2014 including amendment upto and including amendment No. 4 dated 04 Mar 2021 complete with all fittings, accessories and item as specified and as directed. Note: - The energy efficiency level higher than the minimum energy efficiency level as specified here shall be provided without any extra cost in case the transformer of minimum energy efficiency level is not available. | 1 | Each | - | - |
| 6 | S & F XLPE cable end termination, heat shrinkable, indoor type complete with jointing material and accessories suitable for voltage 6.35 kV/ 11 kV (Earthed), 3 core, 120 sqmm to 185 sqmm complete all as specified and as directed. | 5 | Each | - | - |
| 7 | S & F XLPE cable end termination, heat shrinkable, outdoor type complete with jointing material and accessories suitable for voltage 6.35 kV/ 11 kV (Earthed), 3 core, 120 sqmm to 185 sqmm complete all as specified and as directed. | 5 | Each | - | - |
| 8 | Supply, laying and testing cross linked polyethylene (XLPE) insulated, PVC sheathed cables for working voltages 6.35 kV/ 11 kV, three phase, earthed system, 3 core, screened, armoured power cable, 185 sqmm of nominal area of conductor, aluminium conductor, ISI marked as per IS 7098 (Part-II): 2011 and to be laid in trenches, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe etc. making all connections with necessary glands, lugs, bushing complete all as specified and as directed. | 375 | Running Metre | - | - |
| 9 | M & L for earthing complete with perforated galvanised steel pipe electrode 150 mm nominal bore, medium grade, 15 metre length buried directly in ground with top edge of the pipe not less than 1.25 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 2 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, black cotton soil filled upto 7 metre from bottom, magnesium sulphate (compound) in lieu of charcoal or coke and salt in alternate layers in remaining depth including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed. | 20 | Each | - | - |
| 10 | Disconnecting all existing connection including earth wire with transformer of capacity upto and including 400 kVA or 250 kVA installed on plinth or 2 poles or 4 poles structures and taking down and shifting transformer from any substation under the GE to new location with help of Hydra (Recovery)/JCB/ Crane etc. and including installation installed on plinth or 2 poles or 4 poles structures at new location including connecting all connections, earthing, conductors, cables, nuts, bolts, washers etc. and making good disturbed surfaces of plinth, floors, etc. to match the existing surfaces complete all as specified and as directed. | 1 | Each Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.22 MB
BOQ_891045.xls
BOQ • 0.24 MB
TenderDocuments84601.pdf
Tender Documents • 1.97 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .